Inspection history · 16
24 December 2025
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8287132
22 October 2025
Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination · Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8257219
11 March 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8092100
8 March 2024
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7876009
31 October 2023
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7818017
6 March 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7646121
15 March 2022
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7411980
20 September 2021
Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7316469
10 December 2020
COI Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7109433
3 March 2020
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6919615
24 October 2019
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6840869
22 February 2019
Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 6630794
6 November 2018
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6575712
5 December 2017
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6318510
26 October 2017
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6295966
6 December 2016
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6053241
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 December 2025
Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition. Vessel COI is expired as of 22DEC2025.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2025
Resolution: Inspection completed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 March 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: 1) charts, 2) U.S. Coast Pilot. Vessel charts not up-to-date and missing U.S. Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2024
Resolved 18 March 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 March 2024
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. First-aid kit missing content.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2024
Resolved 1 May 2024
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 March 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, and man overboard conditions. Instructions not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2024
Resolved 22 March 2024
Resolution: Posted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2024
Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly. The EPIRB test shall be logged or otherwise documented. Not being logged. completed on this date. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2024
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties. Abandon ship and man overboard drills and training shall be logged or otherwise documented. Not being logged. conducted on this date. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022
Resolved
2 required portable fire extinguishers are in non-serviceable condition. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2022
Resolution: Extinguishers replaced.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 16 March 2022
Resolved
FCC safety certificate is expired. Passenger operations restricted to no more than 1000 feet from shore. 47 CFR 80.401
Action required: 705 - Other - as specified
Resolved 18 March 2022
Resolution: Current safety certificate provided.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 16 March 2022
Resolved
Current employee list not provided. 46 CFR 16.201
Action required: 705 - Other - as specified
Resolved 18 March 2022
Resolution: Current employee list provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 October 2021
Resolved
Machinery space electric submersible pump discharge valve at hull is wasted and requires replacement prior to credit dry-dock. 46 CFR 182.510(e)(7)
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Valve replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2021
Resolved
Life ring in a non-serviceable condition. Replace life ring with approved type prior to credit dry-dock. 46 CFR 180.70
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Life ring replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 October 2021
Resolved
Numerous areas on the hull found to either be blistered or have some type of corrosion. Marked areas to be ground back and repaired prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Marked areas repaired SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
Twist on wire nuts found in wiring throughout the vesse. Wire nuts are to be placed inside an enclosure or replaced by using butt type connectors prior to credit dry-dock. 46 CFR 183.340(h)
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Wire nuts replaced with butt connectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021
Resolved
Dead end wires found througout the vessel. Remove or cap off all dead end wires prior to credit dry-dock. 46 CFR 183.340
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Dead end wiring removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2020
Resolved
Fire buckets not 2.5 gallons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2020
Resolution: Holes drilled to allow only 2.5 gallons in buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2020
Resolved
Lable life ring with vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2020
Resolution: Life ring labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 March 2020
Resolved
Label life float oars.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2020
Resolution: Oars labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 November 2019
Resolved
Port side, inboard sea valve near keel cooler does not close. Repair/replace valve prior to credit dry-dock.
46 CFR 179.350
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Valve replaced; operation SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 November 2019
Resolved
Stbd side through hull connection at side shell, second through hull from the stern is loose. Repair through hull to ensure watertight integrity prior to credit dry-dock. 46 CFR 179.350
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Connection repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 November 2019
Resolved
Numerous soft areas found on the hull. Grind marked spots to find extent of water intrusion and make repairs to the satisfaction of marine inspector prior to credit dry-dock.
46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: All questionable areas repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 November 2019
Resolved
Found loose and decayed wood deck beams around forward lazerette hatch. Make repairs to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Deck beams replaced and deck section around hatch replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 December 2018
Resolved
Vessel's COD expired January 2018. No-Sail issued.
46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2018
Resolution: COD issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2018
Resolved
Engine room bilge high level audible and visual alarms inoperative. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2018
Resolution: Alarms operate SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2018
Resolved
Properly label bilge high level alarms. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Alarms labeled SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 December 2018
Resolved
Repair cracks in life-float. 46 CFR 180.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Cracks sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 13 December 2018
Resolved
Provide proof of submission of MIS report. 46 CFR 16.201
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: MIS report submitted.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 13 December 2018
Resolved
Enter MMSI number into radio(s). 47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: MMSI number installed in radios.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 December 2018
Resolved
Connect radio(s) to GPS or install GPS integrated radio.
47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Radios connected to GPS.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 December 2018
Resolved
Provide EPIRB maintenance log. 46 CFR 185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Log started for EPIRB.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2018
Resolved
Install permanent type connectors on battery cables at terminals. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Lock nuts installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 December 2018
Resolved
Post emergency instructions. 46 CFR 185.512
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Instructions posted.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 December 2018
Resolved
Provide drill log or proof that drill are conducted quarterly. 46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Drill log started.
Communications › Radio Communications › EPIRB
Issued 5 December 2017
Resolved
Provide epirb with current battery prior to going 3 miles from shore.
Condition: Improper/Lack of Maintenance
Due 15 December 2017
Resolved 12 December 2017
Resolution: Provovided new epirb
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 5 December 2017
Resolved
Provide crew list
Action required: 705 - Other - as specified
Resolved 12 December 2017
Resolution: Provide current crew list.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 December 2017
Resolved
Provide waterlight for lifefloat.
Due 15 December 2017
Resolved 12 December 2017
Resolution: Provided new waterlight.
Construction/Loadline › Hull › Bottom Plating
Issued 26 October 2017
Resolved
Repair blisters on hull as discussed by the CGMI.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Repaired all blisters.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 October 2017
Resolved
Re-attach cable from emergency fuel shutoff.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Re-attached cable to valve handle.
Stability › Watertight Integrity › General
Issued 26 October 2017
Resolved
Prove proper operation of rudder room hatch.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Proved proper operation of hatch.