COUNTRY CLUB

COUNTRY CLUB is a 1984 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1985, most recently in December 2025, along with 90 deficiencies and 1 operational control.

Records from 1985 to 2025. Most recent: inspection, 24 December 2025.

Built
1984
Last inspected
24 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL3951
242502
Flag
UNITED STATES
367429220
Maury page id
psix-242502

Inspections, by type

…with no type recorded11
Years with a record 32 calendar years (1985–2025)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.0 ft × 14.5 ft × 7.0 ft
Registered tonnagegross 29 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVANSANT BOAT CO INC · ROCK HALL MD, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portJUPITER, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 2 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Simplified, Gross Ton
23 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL3951MMSI 367429220 · active · compulsorily equipped · granted 7 January 2020, expires 7 January 2030
WDF2553MMSI 367429220 · terminated · compulsorily equipped · granted 24 October 2009, cancelled 17 December 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

24 December 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8287132
22 October 2025 Examination of Repairs · Internal Structural Exam · Administrative Inspection · Hull Examination · Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8257219
11 March 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8092100
8 March 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7876009
31 October 2023 Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7818017
6 March 2023 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7646121
15 March 2022 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7411980
20 September 2021 Administrative Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7316469
10 December 2020 COI Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7109433
3 March 2020 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6919615
24 October 2019 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6840869
22 February 2019 Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 6630794
6 November 2018 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6575712
5 December 2017 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6318510
26 October 2017 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6295966
6 December 2016 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6053241
18 December 2015 Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5784237
27 October 2015 Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5751609
30 November 2010 Initial Certification
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3897212
26 February 2008 Simplified Stability Test
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3158228
25 October 2007 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3086916
13 July 2007 Plan Review "T" Boat
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3011827
2 August 2006 Type not recorded
No type recorded · USCGC BLUEFIN (WPB 87318) · USCG East District (CGD-E) · Activity 2750720
7 November 2005 Plan Review "T" Boat
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2530195
15 April 2005 Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2334415
10 June 2003 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 1813986
28 April 2002 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1610386
29 March 2000 Type not recorded
No type recorded · District 7 (B) · USCG Southeast District (CGD-SE) · Activity 708448
22 October 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 227866
1 July 1997 Type not recorded
No type recorded · District 7 (B) · USCG Southeast District (CGD-SE) · Activity 708447
5 February 1996 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1081209
23 January 1995 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142126
21 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 864693
3 January 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1160608
29 November 1993 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158748
27 March 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 832634
26 March 1993 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1148048
3 March 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 840500
1 February 1993 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831665
20 January 1993 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1140821
11 September 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 945390
3 June 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1258350
4 May 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952442
16 April 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943651
4 June 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 943806
12 December 1990 COI Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268403
6 December 1989 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 941646
26 April 1989 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1350762
28 April 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1340325
2 March 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1024769
23 July 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1009142
24 July 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 989642
10 April 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1307597
20 February 1986 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1306073
26 April 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1292234

Deficiency record · 90

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 24 December 2025 Resolved
An inspection for renewal of a COI is conducted to determine if the vessel is in satisfactory condition. Vessel COI is expired as of 22DEC2025.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 December 2025
Resolution: Inspection completed.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 March 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: 1) charts, 2) U.S. Coast Pilot. Vessel charts not up-to-date and missing U.S. Coast Pilot.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2024
Resolved 18 March 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 March 2024 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents. First-aid kit missing content.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2024
Resolved 1 May 2024
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 8 March 2024 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, and man overboard conditions. Instructions not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2024
Resolved 22 March 2024
Resolution: Posted.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 March 2024 Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly. The EPIRB test shall be logged or otherwise documented. Not being logged. completed on this date. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties. Abandon ship and man overboard drills and training shall be logged or otherwise documented. Not being logged. conducted on this date. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 8 March 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2022 Resolved
2 required portable fire extinguishers are in non-serviceable condition. 46 CFR 181.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 March 2022
Resolution: Extinguishers replaced.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 16 March 2022 Resolved
FCC safety certificate is expired. Passenger operations restricted to no more than 1000 feet from shore. 47 CFR 80.401
Action required: 705 - Other - as specified
Resolved 18 March 2022
Resolution: Current safety certificate provided.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 16 March 2022 Resolved
Current employee list not provided. 46 CFR 16.201
Action required: 705 - Other - as specified
Resolved 18 March 2022
Resolution: Current employee list provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 October 2021 Resolved
Machinery space electric submersible pump discharge valve at hull is wasted and requires replacement prior to credit dry-dock. 46 CFR 182.510(e)(7)
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Valve replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 October 2021 Resolved
Life ring in a non-serviceable condition. Replace life ring with approved type prior to credit dry-dock. 46 CFR 180.70
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Life ring replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 October 2021 Resolved
Numerous areas on the hull found to either be blistered or have some type of corrosion. Marked areas to be ground back and repaired prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Marked areas repaired SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021 Resolved
Twist on wire nuts found in wiring throughout the vesse. Wire nuts are to be placed inside an enclosure or replaced by using butt type connectors prior to credit dry-dock. 46 CFR 183.340(h)
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Wire nuts replaced with butt connectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2021 Resolved
Dead end wires found througout the vessel. Remove or cap off all dead end wires prior to credit dry-dock. 46 CFR 183.340
Action required: 705 - Other - as specified
Resolved 14 October 2021
Resolution: Dead end wiring removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 March 2020 Resolved
Fire buckets not 2.5 gallons.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2020
Resolution: Holes drilled to allow only 2.5 gallons in buckets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2020 Resolved
Lable life ring with vessel's name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2020
Resolution: Life ring labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 March 2020 Resolved
Label life float oars.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 March 2020
Resolution: Oars labeled.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 November 2019 Resolved
Port side, inboard sea valve near keel cooler does not close. Repair/replace valve prior to credit dry-dock. 46 CFR 179.350
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Valve replaced; operation SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 November 2019 Resolved
Stbd side through hull connection at side shell, second through hull from the stern is loose. Repair through hull to ensure watertight integrity prior to credit dry-dock. 46 CFR 179.350
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Connection repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 November 2019 Resolved
Numerous soft areas found on the hull. Grind marked spots to find extent of water intrusion and make repairs to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: All questionable areas repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 November 2019 Resolved
Found loose and decayed wood deck beams around forward lazerette hatch. Make repairs to the satisfaction of marine inspector prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 6 December 2019
Resolution: Deck beams replaced and deck section around hatch replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 December 2018 Resolved
Vessel's COD expired January 2018. No-Sail issued. 46 CFR 67.7
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2018
Resolution: COD issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2018 Resolved
Engine room bilge high level audible and visual alarms inoperative. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2018
Resolution: Alarms operate SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 December 2018 Resolved
Properly label bilge high level alarms. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Alarms labeled SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 13 December 2018 Resolved
Repair cracks in life-float. 46 CFR 180.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Cracks sealed.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 13 December 2018 Resolved
Provide proof of submission of MIS report. 46 CFR 16.201
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: MIS report submitted.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 13 December 2018 Resolved
Enter MMSI number into radio(s). 47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: MMSI number installed in radios.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 December 2018 Resolved
Connect radio(s) to GPS or install GPS integrated radio. 47 CFR 80
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Radios connected to GPS.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 13 December 2018 Resolved
Provide EPIRB maintenance log. 46 CFR 185.728
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Log started for EPIRB.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2018 Resolved
Install permanent type connectors on battery cables at terminals. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Lock nuts installed.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 13 December 2018 Resolved
Post emergency instructions. 46 CFR 185.512
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Instructions posted.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 December 2018 Resolved
Provide drill log or proof that drill are conducted quarterly. 46 CFR 185.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 22 December 2018
Resolution: Drill log started.
Communications › Radio Communications › EPIRB
Issued 5 December 2017 Resolved
Provide epirb with current battery prior to going 3 miles from shore.
Condition: Improper/Lack of Maintenance
Due 15 December 2017
Resolved 12 December 2017
Resolution: Provovided new epirb
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 5 December 2017 Resolved
Provide crew list
Action required: 705 - Other - as specified
Resolved 12 December 2017
Resolution: Provide current crew list.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 December 2017 Resolved
Provide waterlight for lifefloat.
Due 15 December 2017
Resolved 12 December 2017
Resolution: Provided new waterlight.
Construction/Loadline › Hull › Bottom Plating
Issued 26 October 2017 Resolved
Repair blisters on hull as discussed by the CGMI.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Repaired all blisters.
Fire Fighting › Remote Fuel Shutoff › General
Issued 26 October 2017 Resolved
Re-attach cable from emergency fuel shutoff.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Re-attached cable to valve handle.
Stability › Watertight Integrity › General
Issued 26 October 2017 Resolved
Prove proper operation of rudder room hatch.
Action required: 705 - Other - as specified
Resolved 3 November 2017
Resolution: Proved proper operation of hatch.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 December 2015 Resolved
Provide current FCC radio safety certificate.
Due 18 January 2016
Resolved 22 January 2016
Resolution: Provided current FCC radio safety cert.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 December 2015 Resolved
Replace expired aspiren and eye wash in first aid kit.
Due 18 January 2016
Resolved 22 January 2016
Resolution: Replaced expired aspiren and eye wash.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 18 December 2015 Resolved
Provide current alcohol swabs.
Due 18 January 2016
Resolved 22 January 2016
Resolution: Owner provided new alcohol swabs.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 18 December 2015 Resolved
Provide log book or equivelant for documenting emergency drills.
Due 18 January 2016
Resolved 22 January 2016
Resolution: Owner provided new logbook for documenting drills and epirb checks.
Lifesaving › Lifefloat › Serviceable
Issued 18 December 2015 Resolved
Repair cracks in life float with an approved repair kit.
Due 18 January 2016
Resolved 22 January 2016
Resolution: Owner has repaired his life float using the [name withheld] repair kit.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 December 2015 Resolved
Provide pre- employment test results for [name withheld] prior to placing in safety sensitive position.
Due 18 January 2016
Resolved 22 January 2016
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 December 2015 Resolved
Add Shawn Miller to crew list.
Due 18 January 2016
Resolved 28 January 2016
Resolution: Owner has added [name withheld] to crew list.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 18 December 2015 Resolved
Provide updated crew list
Due 18 January 2016
Resolved 28 January 2016
Resolution: Owner has provided updated crew list.
Construction/Loadline › Hull › Bottom Plating
Issued 27 October 2015 Resolved
Submit repair plan for various hull blisters.
Due 10 November 2015
Resolved 10 November 2015
Resolution: Rcvd repair plan.
Electrical › Electric Supply System (service) › Cable
Issued 27 October 2015 Resolved
Remove deadend wiring in the engine room as dicussed with CGMI.
Due 10 November 2015
Resolved 10 November 2015
Resolution: The dead end wiring in the engine room has been removed.
Electrical › Electric Supply System (service) › Cable
Issued 27 October 2015 Resolved
Secure loose wiring in the engine room every 24" using metal clips.
Due 10 November 2015
Resolved 10 November 2015
Resolution: Wiring has been properly secured.
Electrical › Electric Supply System (service) › Cable
Issued 27 October 2015 Resolved
Remove deadend wiring under console.
Due 10 November 2015
Resolved 10 November 2015
Resolution: Deadend wiring has been removed or properly secured.
Stability › Unintentional Flooding › General
Issued 27 October 2015 Resolved
Install shutoff valve closest to the hull as possible for fish box drain. Drain was within 6" of the waterline.
Due 10 November 2015
Resolved 10 November 2015
Resolution: Owner has installed a ball valve for the drain.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 October 2007 Resolved
Renew water tight hatch located forward of the steering compartment.
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 8 November 2007
Resolution: Renewed water tight hatch located forward of the steering compartment.
Stability › Unintentional Flooding › General
Issued 25 October 2007 Resolved
Properly cap unused through-bulkhead penetration between E/R and steering compartment.
Action required: 705 - Other - as specified
Due 25 November 2007
Resolved 8 November 2007
Resolution: Properly capped unused through-bulkhead penetration between E/R and steering compartment.
Lifesaving
Issued 29 November 1993 Resolved
Replace 100 foot seapainter on lifefloat.
Condition: Unknown
Due 29 December 1993
Resolved 3 January 1994
Lifesaving
Issued 29 November 1993 Resolved
Replace missing four foot paddles on lifefloat.
Condition: Unknown
Due 29 December 1993
Resolved 3 January 1994
Documentation
Issued 29 November 1993 Resolved
Provide evidence of drug testing meeting the requirements of 46 CFR part 16specifically a: evidence of pre-employment test for crewman._x001C_ b: results of random testing over the past 12 months at the rate of 50%
Condition: Unknown
Due 29 December 1993
Resolved 3 January 1994
Engineering
Issued 26 March 1993 Resolved
Tighten loose shaft packing.
Condition: Unknown
Due 15 May 1993
Resolved 15 May 1993
Engineering
Issued 1 February 1993 Resolved
REPAIR EXHAUST COOLING WATER ALARM.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Lifesaving
Issued 1 February 1993 Resolved
REPAIR STRAPS ON LIFEFLOAT AND REPLACE RETROREFLECTIVE TAPE ON SAME.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 1 February 1993 Resolved
REPLACE LEAKING FUEL LINE ON GENERATOR AND PROVE OPERATION OF SAME.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Documentation
Issued 1 February 1993 Resolved
PROVIDE CURRENT EXPIRATION DATE STICKER FOR DOCUMENT.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Lifesaving
Issued 1 February 1993 Resolved
REPLACE WEAK LINK ON LIFEFLOAT.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Fire Fighting
Issued 1 February 1993 Resolved
PROVIDE BRACKET FOR AFT FIRE EXTINGUISHER.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 1 February 1993 Resolved
TIGHTEN SHAFT PACKING.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Engineering
Issued 1 February 1993 Resolved
REMOVE CARPET IN WAY OF AND LABEL FUEL SHUTOFF VALVES.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Documentation
Issued 1 February 1993 Resolved
PROVIDE OIL POLLUTION PLACARD.
Condition: Unknown
Due 1 February 1993
Resolved 1 February 1993
Construction/Loadline
Issued 20 January 1993 Resolved
MAKE PERMANENT REPAIRS TO THE BILGE PIPING IN WAY OF COMPARTMENTS TWO AND FOUR.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Fire Fighting
Issued 20 January 1993 Resolved
RECHARGE THE B-I FIRE EXTINGUISHER LOCATED IN THE BRIDGE.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Construction/Loadline
Issued 20 January 1993 Resolved
PROPERLY LABEL THE BILGE MANIFOLD.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Lifesaving
Issued 4 May 1992 Resolved
STENCIL RING BOUY WITH VESSELS NAME.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Construction/Loadline
Issued 4 May 1992 Resolved
REPLACE POOL HOSE WITH SUITABLE MARINE TYPE HOSE FOR USE AS OVERBOARD BILGEDISCHARGE LINE.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Engineering
Issued 4 May 1992 Resolved
INSTALL MACHINERY GUARD ON MAIN ENGINE ALTERNATOR.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Lifesaving
Issued 16 April 1992 Resolved
RENEW REFLECTIVE TAPE ON BOTH SIDES OF LIFE PRESERVERS AS NECESSARY.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Construction/Loadline
Issued 16 April 1992 Resolved
EFFECT PERMANENT REPAIRS TO MAIN DECK AFT, PORT AND STBD. SIDES.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992 Resolved
DOUBLE CLAMP RAW H2O HOSE TO GENERATOR.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992 Resolved
REPAIR AND PROVE OPERATION OF GENERATOR.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Construction/Loadline
Issued 16 April 1992 Resolved
REMOVE OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Engineering
Issued 16 April 1992 Resolved
TIGHTEN SHAFT PACKING.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Electrical
Issued 16 April 1992 Resolved
PROPERLY INSTALL AND WIRE ELECTRIC BILGE PUMP FORWARD.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Lifesaving
Issued 16 April 1992 Resolved
PROVIDE 2 ADDITIONAL ADULT AND 2 ADDITIONAL CHILD SIZE LIFE PRESERVERS.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Lifesaving
Issued 26 April 1989 Resolved
RENEW LINE AROUND OUTSIDE OF RING BUOY IN ACCORDANCE WITH 46 CFR SUBCHAPTER Q.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989 Resolved
RE-NEW RETRO-REFLECTIVE TAPE ON BUOYANT APPARATUS, LABEL WITH VESSEL NAME IN 1-1/2-INCH LETTERS, REPAIR OR RENEW LOOPS SECURING LIFELINE TO BODY. ALLTO BE COMPLETED PRIOR TO CARRYING PASSENGERS ON A COASTWISE ROUTE.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Electrical
Issued 26 April 1989 Resolved
REPLACE ALL UNAPPROVED ELECTRICAL CONNECTORS WITH SOLDERED OR CRIMPED, PERMANENT CONNECTORS. PROPERLY SUPPORT HANGING ELECTRICAL CABLES AGAINST MECHANICAL DAMAGE.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Engineering
Issued 26 April 1989 Resolved
REPLACE FLEXIBLE HOSE FUEL SYSTEM WITH METALLIC FUEL LINE AND THREADED OR FLARED FITTINGS, IN ACCORDANCE WITH 46 CFR 182.20.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Engineering
Issued 26 April 1989 Resolved
SUPPORT HANGING FUEL LINES TO PROTECT AGAINST MECHANICAL DAMAGE.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Lifesaving
Issued 26 April 1989 Resolved
RE-NEW RETRO-REFLECTIVE TAPE ON LIFE JACKETS WHERE NECESSARY, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 26 April 1989
Resolved 26 April 1989
Electrical
Issued 28 April 1988 Resolved
PROVIDE NON-METALLIC, NON-CORROSIVE COVERS FOR BATTERIES.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Lifesaving
Issued 28 April 1988 Resolved
INSTALL WATER LIGHT FOR BUOYANT APPARATUS IN FLOAT-FREE BRACKET ON OPEN DECK.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Engineering
Issued 28 April 1988 Resolved
ELIMINATE LEAK IN EXHAUST COOLING WATER SYSTEM.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988
Engineering
Issued 2 March 1988 Resolved
PROVIDE WATER FLOW WARNING DEVICE FOR ENGINE EXHAUST AS REQUIRED BY 46 CFR 182.15-20.
Condition: Unknown
Due 2 March 1988
Resolved 2 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.