MAURY USCG vessel records Sign in
← All vessels

BINGO

BINGO is a 1983 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in May 2012, along with 145 deficiencies and 1 casualty investigation in 2006.

Records from 1985 to 2012. Most recent: inspection, 30 May 2012.

Built
1983
Last inspected
30 May 2012
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD5254
242611
Flag
UNITED STATES
367114850, 367155720 (licence lapsed)
Maury page id
psix-242611

Inspections, by type

…with no type recorded6
Years with a record 25 calendar years (1985–2012)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.3 ft × 14.8 ft × 7.8 ft
Registered tonnagegross 32 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderVESSELS MARINE MANAGEMENT CORP · MEDLEY, FL, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portATLANTIC HIGHLANDS, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 11 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it32 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDD5254MMSI 367155720 · expired · compulsorily equipped · granted 16 December 2006, cancelled 18 February 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDD2402MMSI 367114850 · expired · compulsorily equipped · granted 16 May 2006, cancelled 16 July 2016
WUT7198MMSI not assigned · expired · compulsorily equipped · granted 14 February 1994, cancelled 25 April 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

30 May 2012 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4328286
26 October 2010 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3877370
5 November 2008 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3357149
5 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3228241
21 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3188640
14 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2937988
9 January 2007 In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2852238
26 September 2006 Hull Examination · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2786951
1 July 2006 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2701745
21 April 2006 COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2630094
30 August 2005 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2480975
7 June 2005 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2361070
4 October 2004 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2212624
18 May 2004 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2070985
27 June 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1828315
3 June 2003 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1809633
24 April 2003 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1779564
5 November 2002 Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1701626
4 October 2002 Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1683423
21 May 2002 Re-Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1618801
1 May 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1395729
2 October 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1458803
29 August 2000 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1054055
12 June 2000 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1437752
10 March 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 885
27 April 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438850
1 October 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1393025
5 May 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1471523
5 May 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1431870
3 October 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1453291
20 August 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1388107
3 May 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1459997
11 August 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 879512
19 May 1995 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 872421
5 May 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1183869
28 October 1994 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175444
5 August 1994 Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172273
5 May 1994 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 860235
19 March 1993 Hull Examination · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1148461
5 May 1992 Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 948012
29 December 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 16878
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940255
8 August 1991 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 665252
2 May 1991 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1223249
19 March 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1237136
16 January 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1215722
19 September 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 901039
25 July 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906016
23 May 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1226775
2 May 1990 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 911254
12 October 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341685
28 September 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1002083
19 September 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 893820
30 August 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203933
7 June 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1205309
3 May 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1351329
15 February 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347720
19 December 1988 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1036824
1 November 1988 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1203176
4 October 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193782
13 April 1988 Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347747
29 October 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1327319
30 September 1985 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 991812
9 September 1985 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 989578

Deficiency record · 145

Construction/Loadline › Hull › Bottom Plating
Issued 5 November 2008 Resolved
Grind to good material all areas on the hull that show signs of blistering or delamination. Once areas are prepared and exposed, call for follow up inspection. If vessel has hole layers removed, vessel shall be layed up as original.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 November 2008
Resolved 16 November 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 April 2008 Resolved
Renew lifeline with approved line.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 5 June 2008
Communications › Radio Communications › EPIRB
Issued 21 April 2008 Resolved
Renew 406 EPIRB battery and hydrostatic release.
Action required: 705 - Other - as specified
Due 21 May 2008
Resolved 5 June 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 9 January 2007 Resolved
Make operable and demonstrate proper operation of all bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 9 January 2007 Resolved
Demonstarte MF radio properly operates.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Lifesaving › Lifefloat › Painter
Issued 9 January 2007 Resolved
Properly configure for float free arrangement and install all life float 60 foot painters to weak link.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 9 January 2007 Resolved
Install a AII fire extinguisher in the pilot house and install a BII fire extinguisher in the accommadation space near the entrance to the generator compartment.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Stability › Watertight Integrity › General
Issued 9 January 2007 Resolved
Make engine room hatch watertight.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Construction/Loadline › Structures › Superstructure
Issued 9 January 2007 Resolved
Properly repair handrails on the port and starboard corners of the transom
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 January 2007 Resolved
Install covers over batteries located in generator compartment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 January 2007 Resolved
Repair all leaks on port and starboard engine exhaust cooling r/w supply lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 January 2007 Resolved
Repair all exhaust pipe leaks on port and starboard engines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Engineering › Bilge Water Management System › Piping
Issued 9 January 2007 Resolved
Renew bilge piping and valves located in the fuel compartment space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 9 January 2007 Resolved
Properly mount light in the engine room and install a protective cover.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 January 2007 Resolved
Provide proof of EAP training for supervisors and crew.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2007
Resolved 26 March 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 26 September 2006 Resolved
Replace cracked port side pilot house window as original.
Action required: 705 - Other - as specified
Resolved 29 September 2006
Resolution: Cleared
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 September 2006 Resolved
Provide servicing report for all portable fire extinguishers as well as the fixed fire fighting system in the engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 September 2006
Resolution: Cleared
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 26 September 2006 Resolved
Provide cover for electrical box located on top of the generator.
Action required: 705 - Other - as specified
Due 4 October 2006
Resolved 11 October 2006
Electrical › Electric Generation Source (emergency) › Conductor
Issued 26 September 2006 Resolved
Remove corrosion from the battery terminals.
Action required: 705 - Other - as specified
Resolved 29 September 2006
Resolution: Cleared
Stability › Watertight Integrity › General
Issued 26 September 2006 Resolved
Make permanent repairs to the screw holes located in the collision bulkhead.
Action required: 705 - Other - as specified
Resolved 29 September 2006
Resolution: Cleared
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 September 2006 Resolved
Provide machinery guards for all unprotected machinery in the engine space.
Action required: 705 - Other - as specified
Due 4 October 2006
Resolved 11 October 2006
Documentation › Markings/Placards › Warning Signs
Issued 26 September 2006 Resolved
Properly label or remove and blank from the vessel switch located on the operators console.
Action required: 705 - Other - as specified
Resolved 29 September 2006
Resolution: Cleared
Engineering › Bilge Water Management System › Not Operational
Issued 21 April 2006 Resolved
Ensure that high level bilge alarm is operation both visually and audibly at the pilothouse.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 21 April 2006
Documentation › Certificates/Documents › FCC SSL
Issued 21 April 2006 Resolved
Renew expired FCC license.
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 12 May 2006
Resolution: Cleared
Documentation › Markings/Placards › Warning Signs
Issued 21 April 2006 Resolved
Renew emergency broadcast placard.
Action required: 705 - Other - as specified
Due 28 April 2006
Resolved 21 April 2006
Lifesaving › Lifefloat › Markings
Issued 21 April 2006 Resolved
Refresh faded markings on all lifefloats
Action required: 705 - Other - as specified
Due 5 May 2006
Resolved 5 May 2006
Resolution: Rvcd documentary proof
Electrical › Lighting (service) › Lighting Fixture
Issued 21 April 2006 Resolved
Remove dead end wiring from unused light fixture in pilot house.
Action required: 705 - Other - as specified
Due 21 April 2006
Resolved 21 April 2006
Electrical › Electric Generation Source (emergency) › Generator Cable
Issued 21 April 2006 Resolved
Clean generator battery terminal.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 April 2006
Resolved 21 April 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 June 2005 Resolved
RAISE FORWARD MASTHEAD NAV LIGHT SO IT IS UNOBSTRUCTED BY THE RADAR. CLEAN ALL LENSES.
Due 7 July 2005
Resolved 30 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Silencer (exhaust)
Issued 7 June 2005 Resolved
DOUBLE CLAMP ALL EXHAUST HOSE CONNECTIONS.
Due 7 July 2005
Resolved 30 August 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 7 June 2005 Resolved
DE-RUST OR RENEW BOTH B-II DRY CHEM FIRE EXTINGUISHERS.
Due 7 July 2005
Resolved 30 August 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 June 2005 Resolved
UPDATE EXPIRED ITEMS IN THE FIRST AID KIT.
Due 7 July 2005
Resolved 7 June 2005
Engineering › Bilge Water Management System › Valve
Issued 4 October 2004 Resolved
PROVIDE POSITIVE CLOSURE VALVES FOR ALL BILGE OVERBOARD PENETRATIONS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 October 2004
Resolved 5 October 2004
Construction/Loadline › Structures › Transverse Bulkhead
Issued 4 October 2004 Resolved
SEAL ALL ELECTRICAL PENETRATIONS IN ALL WATERTIGHT BULKHEADS.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2004
Resolved 5 October 2004
Engineering › Bilge Water Management System › Valve
Issued 4 October 2004 Resolved
PROVIDE HANDLES FOR BILGE VALVES IN WAY OF FUEL TANK SPACE.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2004
Resolved 5 October 2004
Stability › Watertight Integrity
Issued 18 May 2004 Resolved
Prior to sailing repair all hatches to achive designed watertight intergrity. LEGACY COMPONENT DESC: hatches
Action required: 705 - Other - as specified
Due 19 May 2004
Resolved 19 May 2004
Navigation › Piloting/Steering › Marine Charts
Issued 18 May 2004 Resolved
Provide chart for area of operation.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 7 June 2004
Lifesaving › Buoyant Apparatus
Issued 18 May 2004 Resolved
Provide weak link for life floats and two additional paddles. LEGACY COMPONENT DESC: Weak link
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2004
Resolved 19 May 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2004 Resolved
Re-new wasted bonding throughout vsl. LEGACY COMPONENT DESC: Bonding
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 7 June 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2004 Resolved
Provide proper connection (butt connectors) for navigation light wires which run under pilothouse.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 7 June 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 18 May 2004 Resolved
Replace glass globe lights with plastic or provide metal guard.
Action required: 705 - Other - as specified
Due 1 June 2004
Resolved 7 June 2004
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 18 May 2004 Resolved
Provide first aid/ CPR cards for at least 50% of crew.
Action required: 705 - Other - as specified
Due 1 July 2004
Resolved 24 June 2004
Operations/Management › Drug and Alcohol Testing
Issued 24 April 2003 Resolved
FAX CURRENT YEAR MIS REPORT TO MSD FT MYERS. FAX: [phone withheld] LEGACY COMPONENT DESC: MIS Submission
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 18 June 2003
Resolution: Received MIS report from The Maritime Consortium.
Communications › Alarms/Indicators
Issued 24 April 2003 Resolved
CORRECT HIGH WATER BILGE ALARM IN ENGINE ROOM TO PROVIDE AUDIBLE ALARM. LEGACY COMPONENT DESC: High Water Alarm
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 3 June 2003
Navigation › Collision/Grounding Avoidance
Issued 24 April 2003 Resolved
PROPERLY INSTALL NAVIGATION LIGHT WIRE UNDER WHEELHOUSE AND SECURE WIRES TO MASTHEAD LIGHT. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 3 June 2003
Construction/Loadline › Penetrations
Issued 24 April 2003 Resolved
REPLACE GASKETS ON ALL WATER TIGHT HATCHES. LEGACY COMPONENT DESC: Gasket
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 3 June 2003
Construction/Loadline › Penetrations
Issued 24 April 2003 Resolved
CAP OFF THROUGH-HULL PENETRATION ON STARBOARD SIDE ENGINE ROOM. LEGACY COMPONENT DESC: Pipe Flange
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 3 June 2003
Communications › Alarms/Indicators › Propeller Speed Indicator
Issued 24 April 2003 Resolved
REPAIR TACHOMETER FOR PORT ENGINE. LEGACY COMPONENT DESC: Tachometer
Action required: 705 - Other - as specified
Due 14 May 2003
Resolved 1 July 2004
Construction/Loadline › Hull
Issued 4 October 2002 Resolved
RE-LAMINATE PORT STRINGER IN GEN SPACE WHERE BROKEN LOOSE FROM HULL. LEGACY COMPONENT DESC: Stringer
Due 4 November 2002
Resolved 5 November 2002
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 21 May 2002 Resolved
REPLACE TWO PERSONAL MARKER LIGHTS ON ADULT TYPE I PFD'S.
Action required: 705 - Other - as specified
Due 21 June 2002
Resolved 29 May 2002
Communications › Radio Communications
Issued 21 May 2002 Resolved
REPLACE EPIRB BATTERY, EXPIRATION IN MAY 2002. ALSO REPLACE HYDROSTATIC RELEASE FOR EPIRB. ITEM MUST BE CORRECTED PRIOR TO CARRYING PASSENGERS FOR HIRE UNLESS VESSEL IS TO BE OPERATED LESS THAN 3NM FROM SHORE. LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2002
Resolution: PURCHASED NEW EPIRB BATTERY AND HYDROSTATIC RELEASE.
Engineering › Bilge Water Management System › Hose
Issued 21 May 2002 Resolved
REPLACE RAW WATER INTAKE HOSE FOR FIRE/BILGE FIXED SYSTEM.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 May 2002 Resolved
PROPERLY SUPPORT VERTICAL WET EXHAUST PIPES ON BOTH PORT AND STBD MDE'S. LEGACY COMPONENT DESC: Piping (exhaust)
Action required: 705 - Other - as specified
Due 21 June 2002
Resolved 21 May 2002
Construction/Loadline
Issued 12 June 2000 Resolved
INSTALL CLAMP ON R/W SUCTION LINE FOR THE BILGE PUMP.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Construction/Loadline
Issued 12 June 2000 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT INWAY OF HYDRAULIC PIPE RUN.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Deck/Cargo
Issued 12 June 2000 Resolved
INSTALL VALVE ON HYDRAULIC PIPE RUN TO FORWARD WINCH ON METALIC SIDE OF RUNJUST FORWARD OF COLLISION BULKHEAD.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Lifesaving
Issued 12 June 2000 Resolved
PROVIDE AND POST PFD DONNING PLACARD FOR HORSE COLLAR STYLE LIFEJACKET.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Construction/Loadline
Issued 12 June 2000 Resolved
MAKE TRANSVERSE BULKHEAD BETWEEN MACHINERY SPACE AND LAZARETTE VAPOR TIGHT DUE TO FIXED FIRE FIGHTING SYSTEM. INWAY OF WIRE RUN ON STARBOARD SIDE.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Construction/Loadline
Issued 12 June 2000 Resolved
MAKE REPAIRS TO BILGE SUCTION PIPE FOR LAZARET.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Lifesaving
Issued 12 June 2000 Resolved
INSTALL WOOD BATTENS IN BETWEEN EACH LIFE FLOAT TO ALLOW PROPER DRYING.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Lifesaving
Issued 12 June 2000 Resolved
PROVIDE RESCUE LADDER WITH PLATFORM.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Lifesaving
Issued 12 June 2000 Resolved
CONDUCT UNDERWAY DRILLS UPON COMPLETION OF RESCUE LADDER AND PLATFORM.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Construction/Loadline
Issued 3 May 1996 Resolved
CLOSE HOLES AND SEAL OTHER PENETRATIONS IN AFT ENGINEROOM BULKHEAD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Lifesaving
Issued 3 May 1996 Resolved
PROVIDE BRIGHT COLORED CONTAINER FOR FLARES, LABEL WITH "DISTRESS SIGNALS"._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 May 1996
Resolved 3 May 1996
Accommodation/Occupational Safety
Issued 5 May 1995 Resolved
Renew cracked window glass port and starboard passenger space.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Lifesaving
Issued 5 May 1995 Resolved
Repaint 4 lifefloats Interantional orange, re-label with passenger capacityand vessels name.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Construction/Loadline
Issued 5 May 1995 Resolved
Close all openings in bulkhead between engineroom and steering gear room.
Condition: Unknown
Due 5 May 1995
Resolved 5 May 1995
Construction/Loadline
Issued 28 October 1994 Resolved
Double clamp hose from bilge manifold to pump and then the hose from the pump to the fire main.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 28 October 1994 Resolved
Relabel bilge manifold.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 28 October 1994 Resolved
Close holes in collision bulkhead.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Construction/Loadline
Issued 28 October 1994 Resolved
Rerun bilge line to second compartment.
Condition: Unknown
Due 28 October 1994
Resolved 28 October 1994
Navigation
Issued 5 August 1994 Resolved
Prove operation of VHF radio vessel is restricted to not more than 1000' from shore until complete.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Construction/Loadline
Issued 5 August 1994 Resolved
Install valve handle on port engine sea suction.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Construction/Loadline
Issued 5 August 1994 Resolved
Label all bilge suction valves.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Engineering
Issued 5 August 1994 Resolved
Double clamp all raw water hoses in engine room.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Accommodation/Occupational Safety
Issued 5 August 1994 Resolved
Repair hole in deck over passenger cabin starboard side.
Condition: Unknown
Due 10 August 1994
Resolved 10 August 1994
Accommodation/Occupational Safety
Issued 5 May 1992 Resolved
Post sign at sewage overboard valve stating valve to remain closed within territorial seas.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Construction/Loadline
Issued 5 May 1992 Resolved
Install valve at shell connection for generator overboard.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Engineering
Issued 5 May 1992 Resolved
Stencil emergency fuel shutoffs.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 5 May 1992 Resolved
Provide amp meter for generator.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Accommodation/Occupational Safety
Issued 5 May 1992 Resolved
provide means to lock sewage overboard valve system.
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Accommodation/Occupational Safety
Issued 2 May 1991 Resolved
REINFORCE RAILING SUPPORTS PORT & STBD AFT QUARTERS PRIOR TO CARRYING PASSENGER.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 2 May 1991 Resolved
RENEW DECK HATCH GASKET TO COMPARTMENT FWD OF E.R. NO LATER THAN 16MAY91.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Lifesaving
Issued 2 May 1991 Resolved
PROVIDE ONE ADDITIONAL ADULT PFD. LIMITED TO 43 PASSENGERS UNTIL COMPLETED.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Navigation
Issued 2 May 1991 Resolved
REPAIR STERN LIGHT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Documentation
Issued 19 September 1990 Resolved
POST CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Documentation
Issued 19 September 1990 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Documentation
Issued 19 September 1990 Resolved
PROVIDE GARBAGE MAINTENANCE PLAN.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Accommodation/Occupational Safety
Issued 19 September 1990 Resolved
PROVIDE 2 MATTRESSES WITH FIRE RESISTANT COVERS FOR THE 2 LOWER BUNKS.
Condition: Unknown
Due 19 September 1990
Resolved 19 September 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE 3 RED AND 6 ORANGE FLARES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 2 May 1990 Resolved
PROVIDE AN 8" BELL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE 7 LTS. FOR ADULTS LIFEJACKETS. VESSEL IS LIMITED TO 41 TOTAL PERSONS (39 PASSENGERS UNTIL COMPLETE.)
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE 6 - 4' PADDLES FOR THE LIFEFLOATS WITH VESSEL'S NAME STENCILED ON THEM.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Fire Fighting
Issued 2 May 1990 Resolved
PROVIDE 2 B-II FIRE EXTINGUISHERS TO REPLACE THE 2 B-II'S PRESENTLY ONBOARD(FOR ENGINES) PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Documentation
Issued 2 May 1990 Resolved
PROVIDE AND POST EMERGENCY CHECK OFF LIST PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 2 May 1990 Resolved
PROVIDE MEANS TO ISOLATE FUEL OIL TANK REMOTE VALVE HAVDLES FROM THE FUEL TANK SPACE.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 28 September 1989 Resolved
GRIND OUT AND RE-GLASS LEAKING HOLE STBD RUDDER HULL PAD. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Deck/Cargo
Issued 28 September 1989 Resolved
REMOVE OIL IN STERN COMPARTMENT. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Engineering
Issued 28 September 1989 Resolved
RENEW PORT O/B MAIN ENGINE OVERBOARD. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Documentation
Issued 28 September 1989 Resolved
CREDIT DRYDOCK DUE 28MAR91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Deck/Cargo
Issued 28 September 1989 Resolved
RENEW BAITWELL SEAVALVE. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Engineering
Issued 28 September 1989 Resolved
RENEW ALL LAZARETTE MUFFLER HANGARS. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Construction/Loadline
Issued 28 September 1989 Resolved
FILL AND SEAL 2 ROUND HOLES MAIN DECK UNDER STBD SEAT. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Construction/Loadline
Issued 28 September 1989 Resolved
SEAL MAIN DECK OPENINGS OVER TRANSMISSIONS. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Documentation
Issued 7 June 1989 Resolved
COMPLETE ITEMS 6,7 AND 12 ISSUED 03MAY89.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989 Resolved
REPLACE BROKEN LIFEFLOAT WATERLIGHT BRACKET.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Lifesaving
Issued 7 June 1989 Resolved
PROVIDE 1 ADDITIONAL LIFEFLOAT PADDLE.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Accommodation/Occupational Safety
Issued 3 May 1989 Resolved
PROVIDE VENT CLOSURES ALL SPACES EXCEPT E/R.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Lifesaving
Issued 3 May 1989 Resolved
PROVIDE LIFE FLOAT WATERLIGHT (ONE). MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Lifesaving
Issued 3 May 1989 Resolved
PROVIDE ACCESS FOR LIFE FLOATS AND GENERATOR.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 3 May 1989 Resolved
REPAIR WORN LINKAGE - PORT RUDDER JOCKEY BAR.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Engineering
Issued 3 May 1989 Resolved
INSTALL HEAT SHIELDS ON 4 RACOR FUEL FILTERS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 3 May 1989 Resolved
MOVE EPIRB TO OUTSIDE, IN A FLOAT FREE LOCATION. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Deck/Cargo
Issued 3 May 1989 Resolved
BRACKET BILGE LINE IN E/R LEADING AFT.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Construction/Loadline
Issued 3 May 1989 Resolved
BRACKET STBD ENG DRIVEN PUMP DISCHARGE PIPING.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Construction/Loadline
Issued 3 May 1989 Resolved
INSTALL GASKET, CABIN FWD VOID DECK HATCH.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Navigation
Issued 3 May 1989 Resolved
REPLACE SIDE, STERN, AND MASTHEAD LIGHTS. TO BE COMPLETED PRIOR TO CARRY- ING PASSENGERS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Deck/Cargo
Issued 3 May 1989 Resolved
REPAIR OR REPLACE PORTABLE BILGE PUMP. MUST BE COMPLETED PRIOR TO CARRY- ING PASSENGERS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Fire Fighting
Issued 3 May 1989 Resolved
SERVICE B-II CO2 EXTINGUISHER. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 3 May 1989
Resolved 3 May 1989
Documentation
Issued 1 November 1988 Resolved
RENEW FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Electrical
Issued 1 November 1988 Resolved
REPLACE ALL WIRE NUT AND/OR TWIST TAPE SPLICES WITH CRIMPED SPLICE CONNECTORS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Engineering
Issued 1 November 1988 Resolved
REPLACE ENGINE EXHAUSTS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Navigation
Issued 1 November 1988 Resolved
PROVIDE HAND-HELD LIGHT PRIOR TO OPERATING AT NIGHT.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Deck/Cargo
Issued 1 November 1988 Resolved
PROVIDE HAND FIRE/BILGE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Engineering
Issued 1 November 1988 Resolved
TIGHTEN SHAFT PACKING GLANDS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Construction/Loadline
Issued 1 November 1988 Resolved
CAP CRIMPED HOSE AT SKIN IN HOLDING TANK SPACE PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Fire Fighting
Issued 1 November 1988 Resolved
PROVIDE A CHARGED B-II FIRE EXTINGUISHER FOR ONE THAT HAS DISCHARGED BEFORECARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Deck/Cargo
Issued 1 November 1988 Resolved
REMOVE OIL FROM E-ROOM BILGES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Lifesaving
Issued 1 November 1988 Resolved
REPLACE BATTERY AND STENCIL EPIRB.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Electrical
Issued 13 April 1988 Resolved
INSTALL AC GENERATOR IN A WEATHERPROOF COVER AND INSTALL ANMETER, VOLTMETERAND FREQUENCY METER TO THE SATISFACTION OF A CG MARINE INSPECTOR PRIOR TO 05MAY88.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Electrical
Issued 13 April 1988 Resolved
PROVIDE ELECTRICAL OUTLINE ON MODIFICATIONS TO SANITARY SYSTM TO INCLUDE CABLE SIZE AND TYPE.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Deck/Cargo
Issued 13 April 1988 Resolved
PROVE OPERATION OF DECK WINCH.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Navigation
Issued 13 April 1988 Resolved
PROVIDE A 300 MM (8") SHIPS BELL.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Construction/Loadline
Issued 13 April 1988 Resolved
REMOVE ALL HULL BLISTERS ABOVE THE WATERLINE PRIOR TO 05OCT88 IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Construction/Loadline
Issued 13 April 1988 Resolved
GRIND OUT ALL BLISTERS FOR HULL AND BEGIN TO EFFECT REPAIRS PRIOR TO 13APR88. IN THE INTERIM THE VESSEL MAY NOT OPERATE MORE THAN 20 MILES FROMA HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Engineering
Issued 13 April 1988 Resolved
PROVE OPERATION OF FIRE PUMP, STEERING PILOT, HOUSE CONTROL AND MAIN ENGINE
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Electrical
Issued 13 April 1988 Resolved
PROVIDE ONE LINE DIAGRAM TO INCLUDE TYPE AND SIZE OF CABLE, BREAKER RATING FOR INSTALLED A.C. CIRCUIT ALONG WITH DETAILS ON GENERATOR PRIOR TO USING THE SAME.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Construction/Loadline
Issued 13 April 1988 Resolved
MAKE PERMANENT REPAIRS TO THE DELAMINATIONS IN THE TRANSVERSE BHD AN PORT STANCHION BELOW WHEEL HOUSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Construction/Loadline
Issued 13 April 1988 Resolved
REPLACE MSD TANK OVBD, PORT ENGINE RAW WATER SUCTION AND BAIT BOX SUCTION SEA VALVES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988 Resolved
PROVIDE 5 ORANGE SMOKE SIGNALS AND REMOVE ALL OUTDATED SIGNALS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988 Resolved
PORVIDE 4 OPERATIONAL WATERLIGHTS AND 8 OARS FOR LIFE FLOATS PRIOR TO OPERATING MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE. IN THE INTERIM UNTIL ALL EQUIPMENT IS IN PLACE 1 FLOAT MUST BE REMOVED.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988 Resolved
PROVIDE FLOAT FREE LINKS OF THE PROPER SIZE FOR THE LIFEFLOATS PRIOR TO OPERATING IN MORE THAN 100' FEET OF WATER.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Construction/Loadline
Issued 13 April 1988 Resolved
INSTALL CAPTURE CHAINS ON ALL NON-HINGED WEATHER DECK HATCHES.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Documentation
Issued 13 April 1988 Resolved
PROVIDE A VALID FCC RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988 Resolved
STENCIL THE NUMBER OF PFD'S STORED IN STORAGE BOXES AND THE CAPACITY ON THELIFE FLOATS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988

Casualty record · 1

1 July 2006Routine · role: Involved in a Marine Casualty · activity 2701745
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ISLAND LADY (2006). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record