Records from 1994 to 2001. Most recent: inspection, 22 May 2001.
Documentation record
Registered dimensions (L × B × D)81.4 ft × 17.7 ft × 10.3 ft
Registered tonnagegross 99 / net 29
ITC dimensions (L × B × D)81.4 ft × 17.7 ft × 10.3 ft
ITC tonnagegross 99 / net 29
Builderbuilder not recorded · AMSTERDAM, NETHERLANDS ANTILLES · built 1966
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTAMPA, FL
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Uninspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Convention (Subpart B), Gross Ton
29 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
22 May 2001
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1063834
18 January 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451654
1 June 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 819118
18 April 2000
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456817
4 March 1999
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472929
17 February 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1364739
22 December 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 783076
9 October 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424478
26 December 1996
Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1392714
8 November 1996
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172390
18 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1086082
9 June 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1185857
3 November 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 863897
29 August 1994
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1179402
25 July 1994
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1176916
20 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1177235
11 May 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1171279
Construction/Loadline
Issued 18 January 2001
No resolution recorded
ENSURE DOUBLE HOSE CLAMPS ARE INSTALLED TO ALL HOSES SERVICING PIPING SEAWATER CONNECTIONS TERMINATING BELOW THE WATERLINE.
Condition: Unknown
Due 18 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 18 January 2001
No resolution recorded
SHOW THAT EACH AIRPORT HAS A DEAD COVER. ENSURE ALL SECURING DEVICES FOR DEAD COVERS ARE FREE AND IN WORKING CONDITION.
Condition: Unknown
Due 18 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 18 January 2001
No resolution recorded
EITHER PROVIDE HULL MARKINGS IN ACCORDANCE WITH 46CFR185.602 OR EXPLAIN WHYTHE VESSEL DOES NOT REQUIRE THEM.
Condition: Unknown
Due 18 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 18 January 2001
No resolution recorded
ENSURE WIRING PENETRATIONS IN WATERTIGHT BULKHEAD FORWARD OF AFT LAZARETTE/STEERING ROOM IS WATERTIGHT PER DRAWING.
Condition: Unknown
Due 18 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 18 January 2001
No resolution recorded
MAKE WATERTIGHT HOLE IN BULKHEAD BETWEEN ENGINE ROOM AND SADDLE TANK SPACE.
Condition: Unknown
Due 18 April 2001 — due date passed with no resolution recorded
Construction/Loadline
Issued 18 January 2001
No resolution recorded
REPLACE BROKEN SEA VALVE PORT SIDE SERVICING FIRE PUMP.
Condition: Unknown
Due 18 April 2001 — due date passed with no resolution recorded
Electrical
Issued 1 June 2000
No resolution recorded
EITHER REPAIR OR REPLACE THE STARBOARD SHIP SERVICE GENERATOR OR REMOVE IT FROM THE VESSEL AND PROVIDE THIS OFFICE WITH A LIST OF WEIGHT CHANGES. IF IT IS REPAIRED OR REPLACED, PROVE PROPER OPERATION OF GENERATOR PRESENT.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Electrical
Issued 18 April 2000
Resolved
PROVE PROPER OPERATION OF STARBOARD SHIPS SERVICE DIESEL GENERATOR UPON REINSTALLATION.
Condition: Unknown
Due 18 April 2000
Resolved 18 April 2000
Engineering
Issued 18 April 2000
No resolution recorded
PROVE PROPER OPERATION OF MAIN PROPULSION PRIOR TO OPERATING WITH PASSENGERS ON BOARD.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Electrical
Issued 18 April 2000
No resolution recorded
REMOVE AND PROPERLY INSTALL ELECTRIC WIRING TO AFT DECK DECORATIVE LIGHTING
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Lifesaving
Issued 18 April 2000
No resolution recorded
CONDUCT ABANDONSHIP DRILL PRIOR OPERATING WITH PASSENGERS ON BOARD.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Lifesaving
Issued 18 April 2000
No resolution recorded
CONDUCT FIRE DRILL PRIOR TO OPERATING WITH PASSENGERS ON BOARD.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Engineering
Issued 18 April 2000
No resolution recorded
PROVER PROPER OPERATION OF REMOTE MAIN DIESEL ENGINE SHUTDOWNS.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Lifesaving
Issued 18 April 2000
No resolution recorded
RENEW GAUGES ON PORT MAIN DIESEL ENGINE REDUCTION GEAR.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Navigation
Issued 18 April 2000
No resolution recorded
PROVE PROPER OPERATION OF MAIN STEERING SYSTEM PRIOR TO OPERATING WITH PASSENGERS ON BOARD.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Lifesaving
Issued 18 April 2000
No resolution recorded
CONDUCT MAN OVERBOARD DRILL PRIOR TO OPERATING WITH PASSENGERS ON BOARD.
Condition: Unknown
Due 18 July 2000 — due date passed with no resolution recorded
Fire Fighting
Issued 4 March 1999
Resolved
REPLACE LEAKING FIREHOSE ON THE STBD SIDE FIRE STATION.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Engineering
Issued 4 March 1999
Resolved
REPAIR FUEL LEAK ON S/S GENERATOR FUEL RETURN LINE. (ONAN GENERATOR)
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Documentation
Issued 4 March 1999
Resolved
PROVIDE PUBLIC ANNOUNCEMENT CARD.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Construction/Loadline
Issued 4 March 1999
Resolved
CROP AND RENEW HULL PLATING 18" FROM MAIN DECK AND 12" PORT SIDE OF MAIN STEM WHERE HOLED. SUBMIT REPAIR PLAN FOR APPROVAL PRIOR TO COMPLETING REPAIRS.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Engineering
Issued 4 March 1999
Resolved
PROVIDE PROOF OF PROPER OPERATION OF PORT MDE SHUT DOWN FROM OPERATING STATION.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Fire Fighting
Issued 4 March 1999
Resolved
REPLACE FIRE STRAIGHT STREAM FIRE NOZZLE LOCATED ON THE STBD. FIRE STATION WITH A VARI-NOZZLE. REPLACE HOSE AND NOZZLE GASKETS ON PORT SIDE FIRE STATION.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Electrical
Issued 9 October 1997
Resolved
INSTALL EMERGENCY LIGHTING IN OVERNIGHT ACCOMMODATIONS AND ACCESS CORRIDOR.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Electrical
Issued 26 December 1996
Resolved
REPLACE COLLAPSED DUCTING FOR BATTERY ROOM VENT SYSTEM WITH ADEQUATE EXHAUST FAN.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 26 December 1996
Resolved
PROVIDE ACID PROOF BATTERY BOXES FOR GENERATOR START BATTERIES.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Lifesaving
Issued 26 December 1996
Resolved
PERMANENTLY MOUNT AIR COMPRESSOR.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 26 December 1996
Resolved
INSTALL ACID PROOF LINING IN BATTERY ROOM.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 26 December 1996
Resolved
INSTALL METALLIC HOLD DOWN STRAPS FOR ELECTRICAL WIRING RUNS.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 26 December 1996
Resolved
COMPLETE 110VOLT WIRING DIAGRAM.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 26 December 1996
Resolved
INSTALL COVER FOR MDE BREAKER BOX.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Accommodation/Occupational Safety
Issued 26 December 1996
Resolved
INSTALL 39.5" RAILS.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 26 December 1996
Resolved
PROVIDE NAME PLATES WITH REQUIRED INFORMATION FOR ALL GENERATORS.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997