MAURY USCG vessel records Sign in
← All vessels

ZAPATA ARCTIC

ZAPATA ARCTIC is a 1984 mobile offshore drilling unit. The Coast Guard has recorded 23 inspections since 1985, most recently in November 1990, along with 79 deficiencies.

Records from 1985 to 1990. Most recent: inspection, 19 November 1990.

Built
1984
Last inspected
19 November 1990
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

242782
Flag
UNITED STATES
—
Maury page id
psix-242782

Inspections, by type

…with no type recorded5
Years with a record 6 calendar years (1985–1990)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 36 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it10731 - Regulatory (Subpart C or D), Gross Ton
9812 - Regulatory (Subpart C or D), Net Ton
16201 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WFPZMMSI not assigned · expired · compulsorily equipped · granted 24 November 1988, cancelled 24 November 1993
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

19 November 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990548
29 May 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 917201
6 April 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 908143
26 March 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910514
20 March 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 931489
19 January 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 924411
27 December 1989 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 915180
28 June 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 894781
28 June 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 894943
15 January 1989 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 897207
31 May 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197705
19 May 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1350872
6 May 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1344662
27 February 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 992214
25 January 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1331938
12 November 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1022268
19 August 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1029951
24 January 1987 Deficiency Check · Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1009194
20 December 1986 Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1003652
31 January 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1296489
11 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983690
7 July 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983965
23 January 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 979224

Deficiency record · 79

Electrical
Issued 19 January 1990 Resolved
PROVE SATISFACTORY OPERATION OF ESS-1 EMERGENCY SHUT DOWN CIRCUIT TRIP.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Electrical
Issued 19 January 1990 Resolved
PROVE #3 GENERATOR PRIME MOVER SHUTS DOWN COMPLETELY ON ESS-2 EMERGENCY SHUT DOWN CIRCUIT TRIP.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Electrical
Issued 19 January 1990 Resolved
PROVE OPERATION OF EMERGENCY GENERATOR OVERSPEED TRIP, LOW LUBE OIL PRESS ALARM, AND HIGH JACKET WATER TEMP ALARM.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Electrical
Issued 19 January 1990 Resolved
PROVE OPERATION OF EMERGENCY GENERATOR ROOM SUPPLY FAN TRIP.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Electrical
Issued 19 January 1990 Resolved
REMOVE ALL NON HAZARDOUS LOCATION APPROVED LIGHTING FIXTURES FROM ENCLOSED REGION OF DRILL FLOOR AFT OF DRAW WORKS, OR EVIDENCE PREVIOUS ACCEPTANCE OFSAME BY COAST GUARD APPROVING AUTHORITY.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Accommodation/Occupational Safety
Issued 19 January 1990 Resolved
PROVE OPERATION OF MARINE SANITATION DEVICE PRIOR TO VESSEL'S ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Documentation
Issued 19 January 1990 Resolved
PROVIDE RIG OPERATING MANUAL WHICH MEETS REQUIREMENTS OF 46 CFR 109.121.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
RENEW 99 EXPIRED PFD LIGHTS.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
RENEW EXPIRED ORANGE SMOKE DISTRESS SIGNALS IN LIFEBOATS # 1,2,& 4.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
PROVIDE ASTM F1014-1986 TYPE I OR TYPE III FLASHLIGHTS FOR LIFEBOATS #3&4.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Fire Fighting
Issued 19 January 1990 Resolved
DEMONSTRATE OPERATION OF FIRE DETECTION SYSTEM ZONES #1,#2 AND #9.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Fire Fighting
Issued 19 January 1990 Resolved
REMOVE UNAUTHORIZED SWITCH AND WIRING INSIDE FIRE DETECTION SYSTEM CABINET,AND RETURN CABINET COMPONENTS TO ORIGINALLY APPROVED DESIGN SPECS.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
CONDUCT LIFEBOAT FALLS END FOR END FOR LIFEBOATS #1,2,3,&4 NOT LATER THAN 31AUG90.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
WEIGHT TEST LIFEBOATS #1,2,3,& 4 AS DESCRIBED IN 46 CFR 107.239.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
RENEW FOUR EXPIRED LINE THROWING APPARATUS ROCKETS.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Accommodation/Occupational Safety
Issued 19 January 1990 Resolved
REPAIR INOPERATIVE LAUNDRY ROOM FRESH AIR INTAKE FIRE DAMPER.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
REPAIR CRACKED CYLINDER HEAD ON #4 LIFEBOAT MOTOR AND CONDUCT OPERATIONAL TEST TO VERIFY SATISFACTORY OPERATION.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
PROVIDE ONE ADDITIONAL 25 PERSON FLOAT FREE INFLATABLE LIFERAFT WITHIN VALID SERVICE DATE. IMO MODU CODE CERTIFICATE VALID ONLY IF TOTAL PERSONS ABOARD VESSEL RESTRICTED TO MAXIMUM 75 PENDING INSTALLATION OF ADDITIONAL INFLATABLE LIFERAFT.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
CONDUCT ANNUAL SERVICING ON INFLATABLE LIFERAFT #4.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
PROVIDE ONE ADDITIONAL ADULT TYPE I PFD.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Electrical
Issued 19 January 1990 Resolved
REPAIR INOPERATIVE BUS TIE CIRCUIT BREAKER IN EMERGENCY SWITCHBOARD.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Fire Fighting
Issued 19 January 1990 Resolved
REPAIR INOPERATIVE SPRINKLER SYSTEM PRESSURE TANK LOW WATER LEVEL ALARM.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Accommodation/Occupational Safety
Issued 19 January 1990 Resolved
PROVIDE INTERIOR METAL COVERS FOR ACCOMMODATION SPACE WINDOWS FACING DRILL FLOOR.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Lifesaving
Issued 19 January 1990 Resolved
PROVIDE HYDROSTATIC RELEASE UNIT WITHIN VALID SERVICE DATE FOR LIFERAFT #1.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Fire Fighting
Issued 15 January 1989 Resolved
PROVIDE ONE EACH ADDITIONAL OXYGEN METER AND EXPLOSIVE METER.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Documentation
Issued 15 January 1989 Resolved
PROVIDE COPY OF THE STERN TUBE OIL ANALYSIS FOR EACH SHAFT.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Lifesaving
Issued 15 January 1989 Resolved
HAVE LIFERAFT #2 SERVICED AND RETURN TO RIG. UPON ITS RETURN HAVE LIFERAFT#3 REMOVED FOR SERVICING.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Lifesaving
Issued 15 January 1989 Resolved
REPAIR AND PROVE OPERATION OF THE GENERAL ALARM BELLS AND OR LIGHTS LOCATEDPORT FWD SIDE OF WELD SHOP, STBD FWD MOON POOL, AND SACK STORAGE AREA. READJUST BELLS LOCATED ON THE PORT PONTOON OUTSIDE MOTOR ROOM, EXTERIOR ACCOMMODATIONS PORT AND STBD SIDE.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Lifesaving
Issued 15 January 1989 Resolved
INSTALL A RELEASE MECHANISM FOR THE 2 LIFE RINGS WITH LIGHT AND SMOKE TO COMPLY WITH 46 CFR 108.515(D)(2)&(3).
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Documentation
Issued 15 January 1989 Resolved
PROVIDE COPY OF THE UNDERWATER HULL SURVEY REPORT AND VIDEO TO [name withheld], HI.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Fire Fighting
Issued 15 January 1989 Resolved
PROVIDE COPY OF THE FOAM ANALYSIS REPORT.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Unknown
Issued 27 February 1988 Resolved
HYDROSTATICALLY TEST DISCHARGED HALON CYLINDERS AND FLEXIBLE CONNECTIONS. PROVIDE COPY OF SERVICING REPORT. BOILERS SHALL NOT BE PLACED IN OPERATIONUNTIL HALON SYSTEM IS FULLY OPERATIONAL.
Condition: Unknown
Due 27 February 1988
Resolved 27 February 1988
Lifesaving
Issued 25 January 1988 Resolved
PROVIDE 9 ADDITIONAL PFDS. VESSEL LIMITED TO 91 TOTAL PERSONS UNTIL ITEMS ONBOARD.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Lifesaving
Issued 25 January 1988 Resolved
END-FOR-END OR RENEW ALL SURVIVAL CAPSULE FALLS TO COMPLY WITH THE 1983 SOLAS AMENDMENTS. UPON COMPLETION OF WORK A WEIGHT TEST SHALL BE CONDUCTED IN THE PRESENCE OF A USCG INSPECTOR.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Fire Fighting
Issued 25 January 1988 Resolved
PROVIDE A NEW RATE-OF-RISE DETECTOR FOR THE PAINT LOCKER FIXED CO2 SYSTEM.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Fire Fighting
Issued 25 January 1988 Resolved
PROVIDE NEW ACTUATOR VALVE FOR THE BOILER ROOM FIXED HALON SYSTEM. UNTIL REPAIRS COMPLETED POST SIGNS AT ALL REMOTE PULL STATIONS WHICH STATES "SYSTEM CAN ONLY BE DISCHARGED FROM MAIN STATION, EQUIPMENT SHUTDOWNS CAN ONLY BE ACTIVATED FROM MAIN STATION, NO TIME DELAY OR ALARM."
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Lifesaving
Issued 25 January 1988 Resolved
PROVIDE 90 METER PAINTER FOR THE STBD VIKING LIFERAFT LOCATED ABOVE THE ACCOMODATIONS.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Engineering
Issued 25 January 1988 Resolved
MAKE PERMANENT REPAIRS, MODIFICATIONS OR REPLACE PRIMING PUMPS FOR ALL BILGE PUMPS TO PROVIDE A POSITIVE MEANS TO START PUMPS AND OBTAIN SUCTION FROM THE BALLAST CONTROL ROOM AT ALL TIMES.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Deck/Cargo
Issued 25 January 1988 Resolved
PROVIDE COPY OF THE REPORT OF THE RECENT ABS CRANE INSPECTION/TEST.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Engineering
Issued 25 January 1988 Resolved
PROVIDE A HIGH TEMPERATURE STACK ALARM FOR ALL 3 STEAM GENERATORS/HEATING BOILERS TO COMPLY WITH THE COAST GUARD TEST PROCEDURES.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Lifesaving
Issued 25 January 1988 Resolved
REPLACE ALL LIGHTS ON THE EXPOSURE SUITS.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Engineering
Issued 25 January 1988 Resolved
MAKE PERMANENT REPAIRS TO THE NO. 1 HEATING BOILER CONTROL PANEL TO ALLOW NORMAL OPERATION. PRIOR TO PLACING UNIT INTO SERVICE PERFORM AUTOMATION TEST PROCEDURES IN PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Engineering
Issued 25 January 1988 Resolved
MAKE PERMANENT REPAIRS TO THE MODULATOR VALVE ON NO. 2 HEATING BOILER TO ALLOW NORMAL OPERATION. PRIOR TO PLACING UNIT IN SERVICE PERFORM AUTOMATIONTEST PROCEDURES IN PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Lifesaving
Issued 25 January 1988 Resolved
PROVIDE NEW LIGHT STICKS FOR EACH COMPASS ON ALL 4 SURVIVAL CAPSULES.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Lifesaving
Issued 25 January 1988 Resolved
MAKE COAST GUARD APPROVED REPAIRS TO THE DAMAGED AREAS OF THE FRP COVERS ON ALL 4 SURVIVAL CAPSULES WHICH COMPLY WITH THE MANUFACTURERS REPAIR PROCEDURES AND 46 CFR 160.035-8.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Fire Fighting
Issued 25 January 1988 Resolved
MAKE PERMANENT REPAIRS TO THE HELO DECK DRY CHEMICAL SYSTEM; RECHARGE N2 BOTTLES, PROVIDE 3 NEW PRESSURE REGULATOR VALVES & HOSE NOZZLES.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Fire Fighting
Issued 25 January 1988 Resolved
PROVIDE COPY OF THE FOAM ANALYSIS ENSURING COMPLIANCE WITH 46 CFR 107.235 (B)(2)(III).
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Unknown
Issued 20 December 1986 Resolved
CONDUCT ANNUAL SERVICING OF BOTH LIFERAFT HYDROSTATIC RELEASES.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
PROVIDE A RECHARGED CO2 CYLINDER FOR THE PAINT LOCKER.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
PROVIDE TEST RESULTS OF FOAM SAMPLE ANALYSIS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
RECHARGE ALL THE NITROGEN CYLINDERS FOR THE HELO DECK DRY CHEMICAL SYSTEM -EXCEPT FOR THE BOTTOM LEFT HAND CYLINDERS ON THE SKID UNIT.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
REPLACE 2 (EACH) HIGH PRESSURE GAUGES ON THE HELO DECK DRY CHEMICAL SYSTEM,REMOTE NITROGEN CYLINDERS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
REPAIR THE INOPERATIVE 15 PPM ALARM UNIT FOR THE OILY WATER SEPARATOR.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
MODIFY THE OILY WATER SEPARATOR OVERBOARD VALVE SO THAT IT CLOSES AUTOMATICALLY UPON SECURING POWER TO THE 15 PPM ALARM SENSOR UNIT.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
PROVIDE FLOAT FREE SURVIVAL CRAFT OF SUCH CAPACITY AS WILL ACCOMMODATE ALL PERSONS ON BOARD. REF. IMO 10.1.1.2.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
CROP AND RENEW SIDE SHELL PLATE IN THE #10 PORT BALLAST TANK AT 2 LOCATIONS, BETWEEN FRAMES 21 AND 22 WHERE DAMAGED.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
REPAINT THE DRAFT MARKS WHERE ILLEGIBLE.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
REPAIR THE PORT, HIGH SEA CHEST, SUCTION VALVE ACTIVATOR.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
PROVIDE STRAINERS IN ACCORDANCE WITH 46 CFR 56.50-50(G) FOR THE PORT AND STBD PUMP ROOM EMERGENCY BILGE SUCTIONS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
RENEW ALL POTABLE WATER FOR LIFEBOAT #1.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
REPLACE ALL LOW-VELOCITY WATER SPRAY TIPS ON THE FOG APPLICATORS WITH AN APPROVED TYPE. REF 46 CFR 162.027-2(C).
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
PROVIDE CORRECT TYPE OF ORANGE SMOKE DISTRESS SIGNALS FOR ALL LIFEBOATS. ATOTAL OF 8 ARE REQUIRED; 2 FOR EACH.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
RENEW 12 OUT OF DATE DISTRESS SIGNALS FOR THE BRIDGE.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
PROVIDE 3 ROCKETS AND 2 SERVICE LINES FOR THE LINE THROWING APPLIANCE.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Unknown
Issued 20 December 1986 Resolved
CONDUCT ANNUAL SERVICING OF BOTH OF THE INSTALLED LIFERAFTS.
Condition: Unknown
Due 20 December 1986
Resolved 20 December 1986
Lifesaving
Issued 31 January 1986 Resolved
REPLACE SHOULDER TYPE LINE THROWING APPLIANCE WITH IMPULSE PROJECTED ROCKET TYPE.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Lifesaving
Issued 31 January 1986 Resolved
PROVIDE SERVICING FOR NO. 2 INFLATABLE LIFERAFT.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Engineering
Issued 31 January 1986 Resolved
MAKE THE FOLLOWING PRESSURE VESSELS AVAILABLE FOR INTERNAL EXAM AND HYDROSTATIC TEST: BULK A/C, FOAM TANK, DRY CHEMICAL TANK, ALL STANDBY AIR,ALL RISER TENSIONERS, ALL GUIDELINE TENSIONERS, ALL BOP CONTROL, ALL AIR DRIER BULK ACR, AND ALL HELICOPTER FUELING TANKS.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Engineering
Issued 31 January 1986 Resolved
REMOVE THREE HEATING BOILERS FROM SERVICE PENDING APPROVED MODIFICATION TO REMEDY HEAT EXCHANGE PROBLEMS.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Lifesaving
Issued 31 January 1986 Resolved
PROVIDE EVIDENCE OF SUITABILITY OF INFLATABLE LIFERAFT INSTALLATIONS.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Electrical
Issued 31 January 1986 Resolved
REPAIR OR REPLACE SIX GENERAL ALARM SIGNALS.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Unknown
Issued 31 January 1986 Resolved
PROVIDE APPROVED REPAIRS TO HULL DAMAGE ON STARBOARD AFT DIAGONAL AT 77-FOOT MARK.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Unknown
Issued 23 January 1985 Resolved
ITEM 3 ISSUED 8 FEB 84 REMAINS OUTSTANDING. PLEASE ADVISE IF ALL REMAININGPLAN APPROVALS HAVE BEEN COMPLETED.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
EFFECT PERMANENT REPAIRS TO THE NO. 1 WATER BALLAST TANK. AREA COVERED ON THE NUMBER ONE SIDE LONG. AT THE FORWARD OUTBOARD CORNER OF THE PORT PONTOON. AREA APPROX. 3FT X 4FT.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
SUBMIT PLANS FOR THE INSTALLATION OF THE DAVIT AS PART OF THE SUBSEA DIVINGUNIT INSTALLED ONBOARD.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
EFFECT PERMANENT REPAIRS TO THE NO. 1 WATER BALLAST TANK, CREASE APPROX. 8FT X 3FT CENTERED ON THE NO. ONE LONG. BETWEEN FRAMES 68-70.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
EFFECT PERMANENT REPAIRS TO TWO DENTS ON THE STARBOARD MID COLUMN. DENTS ARE APPROX. 3 INCHES DEEP LOCATED BETWEEN "F" AND "G" PARTIAL FLATS ON THE OUTBOARD CYLINDERICAL SHELL PLATING.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
EFFECT PERMANENT REPAIRS TO FOUR APPROX 2 INCH DEEP DENTS IN WAY OF THE STARBOARD FORWARD DIAGONAL BRACE.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985
Unknown
Issued 23 January 1985 Resolved
AS ALL PERMANENT REPAIRS ARE DUE AT THE NEXT REQUIRED VESSEL DRYDOCKING. NODRYDOCK EXTENSIONS WILL BE GRANTED FOR THIS VESSEL. ALL REPAIRS TO BE COMPLETED NO LATER THAN 08FEB86.
Condition: Unknown
Due 23 January 1985
Resolved 23 January 1985

Ownership record