MAURY USCG vessel records Sign in
← All vessels

IL SIN HO

IL SIN HO is a 1989 commercial fishing vessel. The Coast Guard has recorded 13 inspections since 2001, most recently in November 2005, along with 3 deficiencies.

Records from 2001 to 2005. Most recent: inspection, 3 November 2005.

Built
1989
Last inspected
3 November 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA7120
Flag
UNITED STATES
—
Maury page id
psix-24379

Inspections, by type

…with no type recorded8
Years with a record 4 calendar years (2001–2005)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Fishing Vessel class in Maury's sources begin in 1972.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

3 November 2005 Type not recorded
No type recorded · District 14 (OAX) · USCG Oceania District (CGD-O) · Activity 2528092
6 December 2004 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2259422
30 November 2004 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2255401
30 November 2004 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2258702
26 August 2004 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2095063
3 October 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1921754
18 September 2003 Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1909905
29 August 2003 Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1890400
26 August 2003 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 1921709
16 May 2003 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 1800139
26 March 2003 Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1763065
20 June 2001 Type not recorded
No type recorded · USCG Oceania District (dpi) · USCG Oceania District (CGD-O) · Activity 640236
26 February 2001 Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 1499532

Deficiency record · 3

Engineering › Freshwater System (jacketwater cooling)
Issued 29 August 2003 Resolved
Make permanent repairs to jacket water valve to main diesel engine and jacket water valve to ship's service generator prior to departing Saipan. Captain stated Saipan was next U.S. Port. LEGACY COMPONENT DESC: Valve
Action required: 15 - Rectify deficiencies by next port
Resolved 9 September 2003
Resolution: Crew replaced packing on valves. Valves are repaired
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 26 August 2003 Resolved
Make temporary repairs to leaking jacket water valves to main diesel engine to satisfaction of U.S. Coast Guard inspector prior to departing port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Silicone used to stop leak, reissed another deficiency regarding permanent repairs at next US port.
Engineering › Freshwater System (jacketwater cooling) › Valve
Issued 26 August 2003 Resolved
Make temporary repairs to leaking jacket water valves to ships service generator to satisfaction of US Coast Guard inspector prior to departing port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Silicone used for temp. repair, rewrote to make permanent repairs at at next US port.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.