Records from 1985 to 2020. Most recent: inspection, 12 September 2020.
Inspection history · 71
12 September 2020
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7105592
18 December 2018
Damage Survey · Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection · Construction Oversight · Plan Review (Other than "T") · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6600066
15 December 2018
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6603049
26 November 2018
Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6586650
18 October 2018
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6563932
10 October 2018
Special · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6561568
10 October 2018
Type not recorded
No type recorded · Station Tybee · USCG Southeast District (CGD-SE) · Activity 6593512
5 September 2018
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6532555
9 August 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6521367
7 December 2017
Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6338941
17 August 2017
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6242164
19 April 2017
Administrative Inspection · Deficiency Check · Drydock Exam · Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6128439
19 August 2016
Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5976258
9 June 2014
Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4883788
21 May 2012
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4317340
1 August 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4096920
13 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3540823
22 January 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3398195
19 June 2008
Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3238918
11 September 2007
Examination of Repairs · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 3051865
4 April 2007
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2900500
19 February 2007
Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2873861
17 February 2007
Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2873841
18 April 2006
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2633642
6 December 2005
In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 2548935
6 October 2005
Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2509253
11 April 2005
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2331445
9 November 2004
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2237979
15 April 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2065012
7 April 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1769509
8 November 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1707650
8 April 2002
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1602086
13 April 2001
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1062641
31 October 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1055483
6 April 2000
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817592
8 April 1999
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 788742
6 November 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1436140
13 April 1998
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123225
10 April 1997
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1093824
17 December 1996
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1097083
11 April 1996
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1078578
5 September 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 877254
3 April 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1146664
31 March 1995
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1178474
2 November 1994
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1174141
1 September 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 862147
11 April 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1170412
4 April 1994
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1166457
2 April 1993
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1148077
15 December 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 963067
10 April 1992
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 956261
12 December 1991
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1263086
19 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 919574
10 April 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 997399
5 April 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 925097
25 October 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 928456
2 April 1990
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1218586
18 December 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 903944
29 March 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1200199
3 March 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1198291
6 April 1988
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338682
21 March 1988
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1338681
10 November 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1022072
29 September 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1318044
13 April 1987
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1015144
17 March 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324857
10 April 1986
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998550
3 April 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306305
5 November 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1302713
16 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982005
29 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982207
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 December 2018
Resolved
Provide plan for permanent repairs to damaged area located on the starboard side, aft steering compt, measuring 8 feet in length at the water line.
Action required: 30 - Ship detained
Due 4 January 2019
Resolved 1 October 2019
Resolution: Vessel's COI has been deactivated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 November 2018
Resolved
Engine exhaust (Wet) piping is leaking on port and starboard. Make permanent repairs within two weeks. 46CFR182.425
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2018
Resolved 6 December 2018
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 November 2018
Resolved
Vessel made temporary repairs to Port Side stanchion that is bolted to a transverse beam under the main deck due to the beam being split. Temporary repairs approved on 2NOV18 and the Vessel must submit a repair proposal for approval per 46CFR176.600(a) prior next Dry Dock Exam before 30APR2019. CG must approve the proposal prior to work being completed.
Action required: 705 - Other - as specified
Due 30 April 2019
Resolved 6 December 2018
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 October 2018
Resolved
During Vessels haul out to work on Def's 1 and 2 identified the following areas in Blue Chalk:
-Port Side(4 total)
2 Areas= Crop and Renew,
2 Areas= Clean and Sand back for further assessment.
- Stern (1 Total)
1 Area= Clean and Sand back for further assessment.
-Starboard Side(7 total)
1 Area= identified in def 2,
3 Areas= Crop and Renew,
2 Areas= Clean and Sand back for further assessment,
1 Area= Reattach and repair railing system forward.
Vessel must submit a repair proposal for approval per 46CFR176.600(a) prior to carrying passengers. CG must approve the proposal prior to work being completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2018
Resolution: Onsite verification
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 October 2018
Resolved
Vessels compartment forward of the engine room on the starboard side is leaking water due to rotten planks. Vessel must submit a repair proposal for approval per 46CFR176.600(a) prior to carrying passengers. CG must approve the proposal prior to work being completed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2018
Resolution: Onsite verification
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 October 2018
Resolved
Vessel suffered a ingress of water while underway and may not not meet the structural design requirements as described in 46CFR177.300 or material inspection requirements as described in 46CFR176 Subpart H. Prior to the carriage of passengers, US Coast Guard must attend the vessel at dry dock to examine the ships bottom to prove seaworthiness. Additionally, conduct a underway test of the functional systems to the satisfaction of the attending US Coast Guard Marine inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 November 2018
Resolution: Onsite verification
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 9 August 2018
Resolved
Provide third party maintenance to fixed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 24 August 2018
Resolved 21 August 2018
Resolution: A third party report was provided showing repairs.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 August 2018
Resolved
Show proper operation of the fire detection system.
Action required: 10 - Deficiency Rectified
Due 9 August 2018
Resolved 9 August 2018
Resolution: Vessel showed proper operation of fire detection system.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 August 2018
Resolved
Permanently mount H/W alarm in tank room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 23 August 2018
Resolution: H/W alarm was permanently mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2018
Resolved
Rule bilge pump has minor leak in hose going overboard in tank room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 23 August 2018
Resolution: Leak was repaired for Rule Pump in tank room.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2018
Resolved
Two soft patches were found in E/R manifold and store room pick-up.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 September 2018
Resolved 23 August 2018
Resolution: Soft patches will be permantely repaird in 2019 DDX.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 9 August 2018
Resolved
Replace light bulb for compass light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 23 August 2018
Resolution: A new light bulb was placed in service.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 August 2018
Resolved
Show proof of current navigation publications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 23 August 2018
Resolution: New pubs were placed on the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 August 2018
Resolved
Show proper operation of DSC for VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 7 September 2018
Resolution: DSC was installed by a qualified third party.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 August 2018
Resolved
Provide portable lights for the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2018
Resolved 23 August 2018
Resolution: Four additional lights were placed on the vessel.
Communications › Alarms/Indicators › High Water Alarm
Issued 17 August 2017
Resolved
Show proper operation of the steering compartment high water alarm light.
Action required: 705 - Other - as specified
Due 24 August 2017
Resolved 27 September 2017
Resolution: Light bulb was replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 17 August 2017
Resolved
Place in service light cover for engine room light over port engine.
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 27 September 2017
Resolution: Two new lights were placed in service.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 17 August 2017
Resolved
Provide repairs to port engine exhaust pipe.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2017
Resolved 23 August 2017
Resolution: Repairs were made to the port engine exhaust pipe.
Engineering › Bilge Water Management System › Pump
Issued 17 August 2017
Resolved
Show proper operation of port engine bilge pump.
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 23 August 2017
Resolution: Vessel owner showed proper operation of the port engine bilge pump.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 17 August 2017
Resolved
Show proof of annual inspection of fire detection system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2017
Resolved 17 August 2017
Resolution: Vessel owner provided current servicing certificate for fire detection system.
Engineering › Bilge Water Management System › Pump
Issued 19 August 2016
Resolved
Replace impeller & demonstrate bilge pump is in proper working order
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 August 2016
Resolved
Replace expired alcohol swabs
Due 19 September 2016
Resolved 30 August 2016
Electrical › Electric Generation Source (service) › Panelboard
Issued 11 June 2014
Resolved
Repair or replace Hertz Meter.
Due 25 June 2014
Resolved 9 July 2014
Resolution: Meter on hand.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 June 2014
Resolved
Provide Radio Operator Permit.
Due 25 June 2014
Resolved 9 July 2014
Resolution: Master provided permit.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 June 2014
Resolved
Replace all lines on life ring.
Due 13 June 2014
Resolved 9 July 2014
Resolution: Life ring replaced.
Documentation › Markings/Placards › Capacity Marking
Issued 9 June 2014
Resolved
Label Upper deck capacity (62).
Due 13 June 2014
Resolved 9 July 2014
Resolution: Upper deck labled.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 9 June 2014
Resolved
Provide pre-employment testing results for 2 new hires prior to them working in a safety sensitive position.
Action required: 705 - Other - as specified
Resolved 9 July 2014
Resolution: Pre employment test completed and results on hand.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 June 2014
Resolved
Display EAP hotline number and info on drug use/abuse.
Action required: 705 - Other - as specified
Resolved 9 July 2014
Resolution: EAP info properly displayed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 June 2014
Resolved
Supervisor to received 1 hour EAP training.
Due 11 July 2014
Resolved 9 July 2014
Resolution: Traing performed.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 June 2014
Resolved
Crew to receive EAP training.
Due 4 July 2014
Resolved 9 July 2014
Resolution: Training performed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 June 2014
Resolved
Vessel overdue for COI. Vessel to complete a COI inspection prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 June 2014
Resolution: COI exam performed.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 21 May 2012
Resolved
New owner not listed as a member on company roster.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Resolution: Received fax proof of enrollment.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 May 2012
Resolved
Provide proof of Fixed Firefighting system service.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Resolution: Received a faxed invoice of service performed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 May 2012
Resolved
Provide current COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2012
Resolution: Received faxed copy of COD.
Electrical › Electric Supply System (service) › Cable
Issued 21 May 2012
Resolved
Remove dead end wires and twist caps from bridge.
Due 21 June 2012
Resolved 21 June 2012
Resolution: All wires identified have been removed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2012
Resolved
Aspirin and Eye wash are both expired. Replace both items.
Due 21 June 2012
Resolved 7 June 2012
Resolution: Received faxed receipt for new items.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 May 2012
Resolved
Stern light inop. Repair light prior to night operations.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Stern light repaired
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 May 2012
Resolved
Repair anchor light prior to night time operation.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Anchor light has been repaired.
Accommodation/Occupational Safety › Potable Water System › General
Issued 21 May 2012
Resolved
Install cover on water circulator.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Cover has been installed.
Documentation › Markings/Placards › Capacity Marking
Issued 21 May 2012
Resolved
Relabel upper deck to 63 passengers do to new stability requirements.
Due 21 June 2012
Resolved 21 June 2012
Resolution: Upper deck has been properly labeled.
Lifesaving › Hand Flares › Expired
Issued 1 August 2011
Resolved
Found all flares to be expired. Vessel to replace expired flares
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2011
Resolved 4 August 2011
Resolution: Replaced expired flares with new.
Fire Fighting › Fire Pumps › Power Source
Issued 1 August 2011
Resolved
Found electrical wire for fire pump to be corroded. Unit would pulley for fire pump. Vessel to make effect repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 August 2011
Resolved 4 August 2011
Resolution: O/O repaired faulty power supply for Fire pump clutch.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 August 2011
Resolved
Found light not flashing properly. Light wasn't properly packed and missing items in light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 4 August 2011
Resolution: Replaced Liffebuoy light with new,
Lifesaving › Lifefloat › Retroreflective Material
Issued 1 August 2011
Resolved
Found all 3 Life floats onboard to have no retro reflective material.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 August 2011
Resolved 4 August 2011
Resolution: Installed proper Retro.
Documentation › Markings/Placards › Lifejacket Placard
Issued 1 August 2011
Resolved
Lifejacket donning placard missing.
Condition: Improper/Lack of Maintenance
Due 15 August 2011
Resolved 4 August 2011
Resolution: Placards have been installed.
Engineering › Generator (propulsion-electric) › Outlet Box
Issued 19 June 2008
Resolved
Re install generator overboard hose clamp
Due 27 June 2008
Resolved 24 June 2008
Resolution: Overboard clamp was re-installed. Installation was sat.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 June 2008
Resolved
Replace reflector tape on ring buoy IAW 46 CFR 185.604.
Due 27 June 2008
Resolved 24 June 2008
Resolution: Retro reflective tape was replaced to sat of marine inspector.
Documentation › Logs/Records › Drug Test Records
Issued 19 June 2008
Resolved
Provide current contract for chemical testing program (MIS report)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Resolution: MIS/drug contract report was provided-SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 June 2008
Resolved
Replace expired items first aid kit
Due 27 June 2008
Resolved 24 June 2008
Resolution: All expired items were renewed.
Engineering › Bilge Water Management System › Pump
Issued 19 June 2008
Resolved
Demonstrate proper operation of bilge system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Resolution: CG inspector witnessed proper operation of bilge pump.
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 19 June 2008
Resolved
Install (2) smoke detector on vessel
Due 27 June 2008
Resolved 24 June 2008
Resolution: A smoke detector was installed on vessel.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 April 2007
Resolved
INSTALL LIGHT GUARD ENGINE ROOM.
Due 11 April 2007
Resolved 5 April 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 4 April 2007
Resolved
INSTALL COVER OVER SPARE BREAKER BY BAR.
Due 11 April 2007
Resolved 5 April 2007
Construction/Loadline › Hull › Side Shell
Issued 18 February 2007
Resolved
Make permanent repairs to hull damage.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 23 February 2007
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 18 February 2007
Resolved
Ptovide a written repair proposal for approval prior to shifting vsl to home dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 19 February 2007
Communications › Radio Communications › EPIRB
Issued 18 April 2006
Resolved
RENEW EPIRB BATTERY.
Due 1 May 2006
Resolved 1 May 2006
Resolution: Rcvd documentary proof.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2006
Resolved
UPDATE FIRST AID KIT MEDICATIONS.
Due 1 May 2006
Resolved 18 April 2006
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 18 April 2006
Resolved
TIGHTEN SHAFT LOG PACKING ON PORT AND STARBOARD SIDES TO SLOW LEAKAGE.
Due 1 May 2006
Resolved 18 April 2006
Engineering › Bilge Water Management System › Pump
Issued 18 April 2006
Resolved
PROVE PROPER OPERATION OF THE BILGE PUMP.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2006
Resolved 18 April 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 6 December 2005
Resolved
Provide a means of closure for all exhaust vents for spaces protected by a fixed gas extinguishing system.
Action required: 705 - Other - as specified
Due 13 December 2005
Resolved 9 December 2005
Documentation › Markings/Placards › Warning Signs
Issued 6 December 2005
Resolved
Update CO2 instructions to include the closing of exhaust ventsprior to discharging CO2.
Action required: 705 - Other - as specified
Due 13 December 2005
Resolved 9 December 2005
Construction/Loadline › Hull › Hull Plating
Issued 6 October 2005
Resolved
VESSEL TO NOT CARRY PASSENGERS UNTIL A SAT U/W CHECK RIDE CAN BE PERFORMED
Action required: 705 - Other - as specified
Resolved 18 October 2005
Resolution: CONDUCTED SAT U/W CHECK RIDE. VESSEL DRY AND IN SOUND CONDITION.
Lifesaving
Issued 4 April 1994
Resolved
RENEW THE LIFE-LINES ON BOTH STARBOARD BUOYANT APPARATUS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Documentation
Issued 4 April 1994
Resolved
PROVIDE A WASTE MANAGEMENT PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Lifesaving
Issued 5 April 1991
Resolved
MAKE MINOR REPAIRS TO, AND PROPERLY MARK, THE BUOYANT APPARATUS.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Navigation
Issued 5 April 1991
Resolved
MAKE PERMANENT REPAIRS TO THE STERN LIGHT. VESSEL OPERATIONS SHALL BE RESTRICTED TO DAYLIGHT OPERATIONS WITH CLEAR VISIBILITY ONLY UNTIL PERMANENT REPAIRS ARE MADE.
Condition: Unknown
Due 5 April 1991
Resolved 5 April 1991
Lifesaving
Issued 13 April 1987
Resolved
PROVIDE ONE ADDITIONAL RING BUOY AS A SUBSTITUTE FOR REQUIRED PRIMARY LIFESAVING APPLIANCE. VESSEL RESTRICTED TO 144 PASSENGERS (152 PERSONS TOTAL) UNTIL PROVIDED.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987