Documentation record
Registered dimensions (L × B × D)42.7 ft × 13.0 ft × 5.6 ft
Registered tonnagegross 21 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHULLS UNLIMITED EAST INC · DELTAVILLE, VA, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNORFOLK, VA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 4 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
7 April 2026
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8344143
13 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8079648
14 March 2024
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7878493
9 January 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7844272
16 March 2023
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7646406
24 February 2022
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7401547
19 January 2022
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7382598
14 June 2021
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7295538
17 May 2021
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7193470
16 December 2019
Drydock Exam · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6870889
20 May 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6685915
5 March 2018
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6363145
8 February 2018
Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6348661
14 March 2017
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6104653
6 March 2017
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6098525
11 March 2016
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5825610
6 January 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5786367
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 April 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI observed 31 adult life jackets on board, COI requires 32, passenger count reduce to 29 adults.
46 CFR 180.71
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: received photo of new life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 8 April 2026
Resolved
Each paddle must be of at least 1,220 millimeters (4 feet) in length, lashed to the life float to which it belongs and buoyant. MI observed paddle not lashed to life float
46 CFR 180.175(f)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: received photo of paddles being lashed to life raft.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 April 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible; MI Observed charts not up to date, charts were produced in 2022.
46 CFR 184.420(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 29 April 2026
Resolution: received photo of new charts.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 April 2026
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication; MI Observed U.S. Coast Pilot not up to date, Coast Pilot was produced in 2025.
46 CFR 184.420(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 4 May 2026
Resolution: received photo of new coat pilot.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 March 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Packing around exhaust & wires through aft machinery compartment bulkhead is partially missing that would lower the agent concentrate if deployed. 46 CFR 181.420(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2025
Resolved 3 April 2025
Resolution: Objective evidence provided and uploaded to activity; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 March 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (2) U.S. Coast Pilot or similar publication. Coast Pilot was the 2022 edition and not current. 46 CFR 184.420(a)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 April 2025
Resolved 3 April 2025
Resolution: Objective evidence provided and uploaded to activity; all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 March 2025
Resolved
A power-driven vessel underway shall exhibit: (iii) sidelights; and (iv) a stern light. Port light and stern light were inoperable. Corrected during inspection. 33 CFR 83.23(a)(iii)-(iv)
Action required: 10 - Deficiency Rectified
Due 13 March 2025
Resolved 13 March 2025
Resolution: Vessel crew member replaced bulbs in each and tested satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 March 2023
Resolved
A vessel not required to have a power driven fire pump must have at least 3 2.5gal buckets with an attached lanyard. One fire bucket was missing but was replaced in the presence of the CG.
46 CFR 181.610
Action required: 10 - Deficiency Rectified
Resolved 16 March 2023
Resolution: Missing fire bucket was replaced and labeled in the presence of the CG. Ensured bucket had lanyard long enough to retrieve water and the bucket could withstand the weight of the water collected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2022
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. Floating light battery top defective. Vessel restricted to daytime operations only.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: Vessel installed a new battery in the presence of the CGMI and demonstrated functionality of the unit.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2022
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Waterlight line was measured at approximately 12 feet.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: CGMI verified instillation of new lanyard that meets the regulation.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2022
Resolved
Life float must be approved in accordance with 46 CFR 160.027. Life float was painted by vessel operator. Provide documentation that paint used meets original manufacture specification.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: CGMI verified that the life float was re-painted with manufacture recommended paint and color.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 2 March 2022
Resolved
Life float must be approved in accordance with 46 CFR 160.027. Vessel operator replaced life lines and pendants. Provide documentation that all lines replaced meet and are installed as per manufacture specification.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: Vessel crew moved pendants to beckets as per manufacture reccomendations.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 March 2022
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. FWD cabin weathertight overhead ventilation hatch leaked during test. Repair gasket where missing section was found in accordance with manufacture specifications and complete a weathertight leak test in the presence of a Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 April 2022
Resolution: Vessel crew re-installed gasket and tested in the presence of a [name withheld] sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 May 2021
Resolved
Found vessel's life-float weathered and with several cuts. Each item of survival craft equipment must be of good quality and efficient for the purpose it is intended to serve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 July 2021
Resolution: Vessel operator repaired life-float in accordance with manufactures specifications.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2020
Resolved
Piping including valves, pipe fittings and flange conveying vapor, gas, or liquid, the temperature of which exceeds 65.5°C (150°F), must be suitably insulated where necessary to prevent injuries. Found area between the engine turbo and the raw water exhaust cooling injector needed lagging due to indicators it is a hot surface.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 30 June 2020
Resolution: Vessel representative provided photograph of sufficient lagging placed on the engine turbo and the water cooling injector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 June 2020
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the OCMI. Found two fire extinguishers at the operating station secured in their bracket by a bungy cord.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2020
Resolved 30 June 2020
Resolution: Vessel representative provided photographs for the two fire extinguisher brackets mounted at the operating station.
Engineering › Steering Gear System › Bracket/Clamp
Issued 6 March 2017
Resolved
Steering gear apparatus found not suitable due to being mounted on cracked block of wood. Steering gear must be suitable for intended use. Repair to the satisfaction of the attending CGMI. (Old T 46 CFR 182.30-1)
Action required: 705 - Other - as specified
Due 13 March 2017
Resolved 10 March 2017
Resolution: Cracked block of wood that the steering gear was mounting on was replaced with Starboard Marine Board.