LADY DOLPHIN OF DAYTONA
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named LADY DOLPHIN OF DAYTONA
LADY DOLPHIN OF DAYTONA is a 1984 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in March 2026, along with 164 deficiencies, 2 operational controls and 1 casualty investigation in 2009.
Records from 1985 to 2026. Most recent: inspection, 16 March 2026.
- Built
- 1984
- Last inspected
- 16 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 164 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2009
Identity
665501
WDB8775
243933
Flag
UNITED STATES
368093660
Maury page id
psix-243933
Inspections, by type
…with no type recorded8
Years with a record
40 calendar years (1985–2026)
The 79 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)59.5 ft × 20.5 ft × 4.7 ft
Registered tonnagegross 50 / net 25
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHANS HANSEN CO · TOLEDO, OH, UNITED STATES · built 1984
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portDAYTONA BEACH, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 June 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
25 - Regulatory (Subpart C or D), Net Ton
25 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK8389MMSI 368093660 · active · compulsorily equipped · granted 17 May 2019, expires 17 May 2029
WDB8775MMSI 366963950 · expired · compulsorily equipped · granted 21 June 2014, cancelled 14 September 2024
WCI2517MMSI not assigned · expired · compulsorily equipped · granted 3 June 1994, cancelled 8 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 79
16 March 2026
COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8326749
3 December 2025
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8273125
2 July 2025
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8179167
24 June 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8162090
8 August 2024
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7977859
12 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7933451
4 December 2023
Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7833546
16 November 2023
Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7826056
14 June 2023
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7715731
8 June 2022
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7464432
3 December 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7359285
12 April 2021
Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7152165
1 July 2020
Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6966030
20 November 2019
Internal Structural Exam · Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6865856
15 May 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6677704
17 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6416364
22 November 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam · Plan Review "T" Boat
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6311357
21 June 2017
Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6181596
19 December 2016
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6058247
19 October 2016
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6025807
14 April 2016
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5852539
30 November 2015
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5770337
12 August 2015
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5214088
16 July 2015
Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5183299
6 August 2014
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4947280
30 July 2012
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4395961
11 July 2012
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4340630
29 January 2010
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3662619
16 December 2009
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3651251
11 July 2009
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3533647
15 August 2008
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3299093
17 July 2008
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3269624
5 December 2007
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3093309
18 July 2007
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2999626
25 June 2007
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2960362
13 April 2006
COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2623682
4 November 2005
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2523841
11 July 2005
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2418362
21 September 2004
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2200823
12 July 2004
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2125712
29 January 2004
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1996780
6 November 2003
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1943609
22 October 2003
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1933522
21 May 2003
Annual Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1798487
8 January 2003
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1727490
4 December 2002
COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1713891
5 June 2002
Re-Inspection · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1626325
9 April 2002
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1602741
15 June 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1065817
16 April 2001
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1373432
13 April 2000
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1049233
20 May 1999
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 797429
19 April 1999
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1466038
17 April 1998
COI Inspection · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1381202
1 May 1997
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1106512
3 April 1997
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1439860
22 March 1996
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1360441
13 April 1995
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1358704
15 April 1994
Hull Examination · COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1166964
15 April 1994
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1328075
10 May 1993
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1356288
7 May 1992
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1265118
1 August 1991
Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 935825
14 May 1991
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 902438
26 April 1990
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 916626
6 June 1989
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1352014
22 May 1989
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1033422
4 April 1989
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1036024
28 December 1988
Hull Examination
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1346350
21 June 1988
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1202554
16 June 1988
Plan Review "T" Boat
Administrative · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1205326
8 June 1988
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1200646
2 June 1988
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 887356
17 May 1988
COI Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1043835
4 May 1987
COI Inspection
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1017628
23 October 1986
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1017174
16 April 1986
Deficiency Check
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1003128
4 April 1986
Re-Inspection
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1305133
5 April 1985
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1287745
Deficiency record · 164
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 March 2026
Resolved
59 adult life jackets had deteriorated retro. Vsl is limited to 78 adults.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 March 2026
Resolved
Gen prime mover cooling water piping had salt build up/ corrosion. Vsl is required to fix leak, clean the surface/pipe for inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 March 2026
Resolved
life ring had deteriorated retro and a corroded/seized clip for the water light.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2026
Resolved
Vsl had dead-end wire in the bridge console, wire nuts in the bridge console, overhead on the second deck and on the gen battery. Vsl is required to make proper installation and make all wiring safe.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2026
Resolved
Main deck distribution panel had an opening blocked by duct tape. Vsl is required to fill the opening with a breaker or a proper blank.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2026
Resolved
Battery charger in the bridge console did not have an amp meter (only a visual indicator light bar was observed).
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 March 2026
Resolved
Vsl had 4 large lead acid batteries in the seating compartments on the main deck. Vsl is required to remove the batteries.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 March 2026
Resolved
Vsl had a hole that was leaking rain water from the second deck overhead ceiling. Vsl is required to repair/replace the overhead ceiling in that location to prevent water intrusion.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2025
Resolved
A vessel must be provided with bilge pumps. Bilge lines to shaft alley and laz space were not re-installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 3 December 2025
Resolved
Inspection of the condition of the superstructure. Remove doubler on lower port and stbd aft corners. Submit repair proposal and complete repairs prior to annual exam.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 June 2025
Resolved
The general construction of the vessel must minimize fire hazards. Structural fire protection missing in ladder well to engine room.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 June 2025
Resolved
The general construction of the vessel must minimize fire hazards. The fire-damper in the engine room ladder well has light shining through.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2025
Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Remove/replace zip ties in overhead.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2025
Resolved
Twist-on type connectors may not be used for making joints in cables. Remove/replace twist-on wire nuts on 2nd deck speakers, and outboard of galley fridge, base of stairs stbd outboard
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2025
Resolved
Openings through which conductors enter shall be adequately closed. Properly close up junction boxes.
46 CFR 183.10-20(f)(1)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2025
Resolved
Adequate emergency lighting automatically actuated upon failure of main lighting system. Extinguished emergency lighting stbd side cabin.
46 CFR 184.30-5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 June 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew and the vessel from electrical hazards. Remove/replace dead end wires in galley, broken antenna on wheel house, phone cable stbd side wheel house, cables to Garmin in wheel house, and light fixtures. Hard wire portable A/C unit in wheel house.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 June 2024
Resolved
At each initial inspection and subsequent inspection for certification and reinspection the marine inspection shall examine and the test the main and auxiliary steering apparatus to the extent necessary to determine that its condition is satisfactory and is fit for the service intended. The main and auxiliary steering apparatus shall be tested by operation and the inspector shall examine the mechanism thereof throughout its length.
Vessel steering control at the operating station was being centered to amidships by bungie cords.
46 CFR 176.25-35 (Old T)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 June 2024
Resolved
Provision shall be made by means of plugs, covers, etc, to prevent the admission of air into the space protected.
The class 1 watertight door gasket leading into the engine room is deteriorated.
46 CFR 181.20-35 (Old T)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2024
Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test all boilers and unfired pressure vessels to the extent necessary to determine the condition is satisfactory and that they are fit for the service for which intended.
The plug on the receiver was damaged.
46 CFR 176.25-30
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2024
Resolved
At each inspection for certification the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
The AC raw water pump and piping arrangement was not permanently secured.
46 CFR 176.25-50
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 June 2024
Resolved
Exhaust piping shall be led to the point of escape with a minimum number of bends or elbows. It shall be gas tight throughout its length and shall be properly supported by noncombustible hangers or blocks.
The Port Main Engine has an exhaust leak.
46 CFR 182.15-20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 June 2024
Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its design limitations.
The Port Main Engine was found to have an excessive leak on the accessory drive distibuting oil onto the overhead.
46 CFR 182.05-1 OLD T
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 June 2024
Resolved
Life preservers for children when provided, shall be stowed separately.
The adult lifejackets and child sized lifejackets are stowed in the same locker without separation.
46 CFR 180.25-10 OLD T
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 12 June 2024
Resolved
A vessel on a Rivers route must carry three red flares and three orange smoke distress signals. The orange smoke may be substituted for three red flares.
The distress signals were expired.
46 CFR 180.70(b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2024
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems... to determine they are in suitable condition and fit for the service intended"
An unidentified hydraulic leak in steering system. There is a five-gallon bucket installed on the bridge w/ hand pump to refill the steering gear hydraulic system.
46 CFR 176.25-35
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2024
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock.
AC Condenser condensation being collected in galley serving tray, and buckets hanging over passenger accommodation spaces and dripping onto electrical equipment.
46 CFR 183.01-05
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 June 2024
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock.
Unsafe electrical maintenance practices were observed throughout vessel.
Numerous power strips and extension cords were found being used as jumpers in the main galley, service room and bridge, dead end wires were found throughout the vessel, several splices were observed and not in an enclosed electrical box. Terminal strips under the bridge console are not secured and are hanging by wires.
46 CFR 183.01-5(a)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 June 2024
Resolved
At each initial and subsequent inspection for certification the firefighting equipment of all vessels shall be inspected and all deficiencies shall be corrected.
The flexible connection on the co2 fixed fire suppression system is kinked and restricted.
46 CFR 176.25-25
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 June 2024
Resolved
All vessels except non-self propelled vessels shall be provided with suitable steering arrangements.
The Jockey bar between both rudders has a deflection of 6”-12” when hard over due to misalignment of rudder arms.
46 CFR 182.30-1
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2024
Resolved
The vessel is a SPV-T (Old) and therefore is not required to have a safety management system per regulation. Requirement 1 through 5 are objective evidence that a serious substandard condition has been proactively managed by the vessel's owner/operator leading to a lack of safety culture onboard the vessel.
46 CFR 176.830
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 June 2024
Resolved
Examine watertight closures in bulkheads.
WTD between steering compartment and aft auxiliary space could not be secured. WTD between aft auxiliary space and engine room could not be secured. 46CFR 176.25-5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2024
Resolved
Comply with stability letter.
Two unapproved poly tanks were discovered in a void fwd of the engine room. 46CFR 170.120
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 12 June 2024
Resolved
Fire main and hydrants shall comply with 181.15-5.
Single fire hydrant as provided cannot reach all parts of vessel with single length of hose. 46 CFR 181.15-5
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2024
Resolved
Inspect vessel for unsafe practices. 46 CFR 176.25-50
Wood blocks, screws and hose clamps are used to secure the galley steam kettles, sewage pump and a/c r/w pumps.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 June 2024
Resolved
Inspect vessel for unsafe electrical installations. 46 CFR 183.01-5
Permanently repair a/c condensate drain pan by 01Jan2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 June 2022
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens. The flames screens must consist of a single screen of corrosion resistant wire of at least 30X30 mesh. Wasted flame screen on fuel tank vent.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2021
Resolved
A drydock examination conducted in compliance with 176.600. The following must be completed for credit drydock:
a. Washed out welds on port and starboard stern tubes.
b. Aft paddle wheel deck transverse frames found wasted, 4 on starboard side and 3 on port side.
c. UT shots needed in the following locations: starboard side shell amidships, starboard bow, port bow, and paddle wheel decking.
d. Side shell inset port side of stem.
e. Clean through hull fittings of marine growth.
f. Wastage on starboard side paddle wheel bearing housing.
g. Port and starboard rub rail renewal including bow.
h. Transverse frames in lazarette and sewage tank room.
i. Longitudinal and vertical stiffeners on port side of sewage tank room
j. Cap off old through bulkhead penetration between sewage tank room and engine room.
k. Properly seal the penetrations on the port side of the collision bulkhead
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021
Resolved
The power fire pump shall be self priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Hose stream is ineffective to serve as a fire fighting means.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2021
Resolved
A length of fire hose shall be attached to each fire hydrant at all times. Fire hose is currently kept disconnected and stowed in a closet nearby. 181.15-10(g)
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 12 April 2021
Resolved
Unless otherwise authorized by the Coast Guard each device for which certification under this part is requested must meet the requirements of this subpart. The MSD pump is consistently leaking.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 April 2021
Resolved
EAP trianing program: Supervisory personnel must receive at least 60 minutes of training. DAPI audit revealed supervisor has not received supervisory training.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 July 2020
Resolved
Connections and terminations to all conductors must retain the original electrical, mechanical, flame-retarding, and fire-resisting properties of the cable. All connecting devices must be suitable for copper stranded conductors. There were melted wires around the exhaust of the A/C unit. There were dead end wires found in the forepeak, operating station, and store room. Repair, replace or remove melted wiring above exhaust. Properly insulate dead end wiring.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 1 July 2020
Resolved
Each entrance to a space storing carbon dioxide cylinders or a space protected by carbon dioxide systems must be conspicuously marked as indicated in 46 CFR 185.612(g)(1) and (2). A/C room and engine room has no markings. Mark A/C room and both engine room doors as indicated above.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2020
Resolved
A life jacket must be provided for each person carried on board a vessel. Only 108 life jackets are on board vessel. Outfit vessel with the proper amount of life jackets.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 July 2020
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Pump in A/C room missing guard, which exposes rotating machinery. Replace guard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 July 2020
Resolved
Al wires and cables shall be suitable for marine service and for the particular installation used, hot water heater pump switch is hung on the bulkhead with zip ties. Permanently mount electrical switch to the bulkhead.
Old T cited not listed in MISLE; 46 CFR 183.10-20
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2020
Resolved
Drip pans fitted with flame screens may be required under fuel strainers other than those mounted on the engines. Installed drip pans on the generator and port engine have holes. Repair replaced damaged drip pans.
Old T cited not listed in MISLE; 46 CFR 182.20.40(b)(5)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 July 2020
Resolved
The general construction of the vessel must be such as to minimize fire hazards in so far as reasonable and practicable. Engine room overhead has several sections of insulation missing. Install missing portions of insulation in overhead.
Old T cited not listed in MISLE; 46 CFR 177.10-5
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2019
Resolved
Each life jacket must be approved in accordance with subchapter Q specifications, or other standard specified by the Commandant. 99 life jackets had worn or missing retro reflective tape. Replace with the approved retro reflective tape.
01 - Certificates & Documentation › 011 - Ships Certificates › Passenger Ship Safety (including exemption)
Issued 15 May 2019
Resolved
When necessary for safe operation, the cognizant OCMI may place specific stability restrictions in a stability letter or on the Certificate of Inspection of a vessel not more than 65 feet in length. There was an excess of 13 chairs on the upper passenger deck than were allowed on the stability letter. Remove excess chairs.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 May 2019
Resolved
The maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. The sign for the maximum passengers allowed on upper deck was painted over. Mark each entryway with the proper information.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 15 May 2019
Resolved
Each stowage container for life jackets must not be capable of being locked. Container was capable of being locked. Remove the latch on the container.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 15 May 2019
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Post instructions on the outside of the life jacket container.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 May 2019
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Captain and two crewmembers were not on enrollment letter. Ensure all crewmembers are tested and on the consortium.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2019
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Mark the life jacket container on the upper deck with the proper information.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 May 2019
Resolved
A hatch exposed to the weather must be watertight. Gasket on hatch to lazarette was missing. Ensure all gaskets on the hatches are in good working order.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 15 May 2019
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Bulkhead in aft pump room had a gap in the wall IVO electrical cord. Ensure bulkhead in aft pump room is made watertight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2019
Resolved
Minimize accidental personnel contact with energized parts. There were several dead end wires in the sewage pump room. Remove all dead wires.
Fire Fighting › Combustible Materials › Insulation
Issued 17 May 2018
Resolved
The general construction of the vessel shall be such as to minimize fire hazards. Vessel need to replace SFP over Starboard main engine and reattach SFP in port side of engine room. 46 CFR 177.10-5(A)
Electrical › Electrical Distribution System (service) › Cable
Issued 17 May 2018
Resolved
Wiring joints and splices shall be mechanically secure and made in junction boxes. Dead end wires in engine room in way of entrance need to be removed. 46CFR183.05-50(B)
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 May 2018
Resolved
Provide a minimum standard for electrical installations that will result in a vessel reasonably safe from electrical shock od personnel. Replace face plates on 02 electrical plugs in galley. 46 CFR 183.01-5
Lifesaving › Hand Flares › Expired
Issued 17 May 2018
Resolved
All vessels shall carry pyrotechnic distress signals as follows: three re hand flares are expired. 46CFR 180.68 (B)(1).
Communications › Visual Communication › Red Warning Signal
Issued 21 June 2017
Resolved
The WTDs below deck did not have indicators, on the bridge, to alert the master that the doors were open. The vessel has been this way since operating.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 June 2017
Resolved
Vessel had a first aid kit but the contents did not have required equipment.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 21 June 2017
Resolved
Label/seperate upper deck child PFD storage.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2017
Resolved
The upper deck had heaters mounted in the overhead that were plugged in vs wired into distribution panel.
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 21 June 2017
Resolved
Replace or repair frayed rope light at the gangway.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 21 June 2017
Resolved
The watertight bulkhead between the fuel tank space and the storage void has a wire run penetrating that is not watertight.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 June 2017
Resolved
Install inner cover on the main distribution panel on the port side of the A/C chiller room.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 June 2017
Resolved
Repalce (03) outlet face plates in the galley.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 June 2017
Resolved
Install cover for the blower fan controller in the engine room.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 19 December 2016
Resolved
Fixed CO2 Fire Extigushing System was out of service date isuued No Sail 835
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 14 April 2016
Resolved
Provide a means to close ventilation to engine room.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 14 April 2016
Resolved
Remove all flammable liquids from vessel that are not for daily use or stowed in an approved manner.
Navigation › Piloting/Steering › Magnetic Compass
Issued 14 April 2016
Resolved
Provide a means to illuminate the magnetic compass.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 14 April 2016
Resolved
Install marking for each emergency escape indicating "emergency exit, keep clear".
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 April 2016
Resolved
Ensure vessel is equipped with a first aid kit equipped with all contents required by 46CFR160.041
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 April 2016
Resolved
Ensure each flexible hose installed in a vital system is provided two hose clamps for each end.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 16 July 2015
Resolved
Vessel does not have current charts, light list, or coast pilot for operating areas. Provide proof of charts and publications. 46CFR184.420
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 July 2015
Resolved
Vessel does not currently have valid COD onboard. Provide proof of current COD. 46CFR67.7
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 July 2015
Resolved
Vessel does not have emergency instruction posted at operating station. Instructions are not tailored to the vessel. Post vessel specific instructions at operating station. 46CFR185.510
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 16 July 2015
Resolved
Ring life buoy requires to be marked clearly with vessels name and retro to be marked properly. 46CFR180.70/185.604
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 16 July 2015
Resolved
Found aft steering compartment visual indicator not operational at operating station. Install visual indicator for pump activation. 46CFR182.530(3)(c)
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2015
Resolved
Remove of permanently mount DJ lighting. 46CFR176.830
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 16 July 2015
Resolved
Found damaged/loose insulation in machinery space boundaries. Repair or renew insulation. (46CFR177.410(c)(4).
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 16 July 2015
Resolved
Found generator exhaust leak. Repair and install heat shielding. 46CFR182.15-20 OLD T
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 July 2015
Resolved
Found numerous tripping hazards in machinery space bilges; obstructing access to high level bilge alarms and miscellaneous equipment. Properly stow and secure gear for sea service. 46CFR176.830
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 16 July 2015
Resolved
Found loose electrical receptacles on the aft upper passenger deck. Secure receptacles. 46CFR183.01 OLD T
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 July 2015
Resolved
Found life-preserver storage containers mislabeled on the upper passenger deck. Containers are also capable of being locked. Properly label containers and remove locking capability. 46CFR180.78
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 July 2015
Resolved
Numerous "[name withheld]" life-preservers found in need of repair and labeling. Multiple life-preservers were also in need of retro-reflective (Type I) tape. Repair, re-label, and affix retro-reflective tape. 46CFR180.71/185.604
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 July 2015
Resolved
Permanently installed extension cords found throughout vessel in engine spaces, galley, and main/upper passenger decks. Remove permanently installed extension cords. 46CFR183.01-15 OLD T
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2015
Resolved
Overhead light fixture on the upper passenger deck missing protective casing. Install protective casing around light fixture. 46CFR111.75-20
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 16 July 2015
Resolved
Found speaker in engine room ladderwell unsecured in overhead. Secure or remove speaker. 46CFR176.830
Engineering › Reduction Gearing/Clutches › Gear
Issued 16 July 2015
Resolved
Reduction gear oil coolers for both MDE's were found to be supported by wire ties. Install permanent support system. 46CFR176.830
Electrical › Lighting (service) › Lighting Fixture
Issued 16 July 2015
Resolved
Found numerous light fixtures missing bulbs exposing sockets outside pilot house. Install bulbs or plugs to mitigate electrical hazards. 46CFR111.75-20
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 16 July 2015
Resolved
Unable to conduct satisfactory man overboard and firefighting drills. Conduct satisfactory drills in the presence of a U.S.C.G. MI. 46CFR176.808
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 11 July 2012
Resolved
Emergency Broadcast Placard and Emergency Instructions missing. Post Emergency Broadcast Placard and Emergency Instructions IAW 46 CFR 184.506 and 46 CFR 185.510.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 11 July 2012
Resolved
Sheet metal obstructing generator vents. Remove sheet metal from generator vents.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 11 July 2012
Resolved
Excess oil on generator windings and housing. Clean windings and housing to satisfaction of Coast Guard inspector.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 December 2009
Resolved
Vessel was due for drydock completion 31 DEC 2009. Drydock extension is approved until 07 JAN 2009. Vessel may not carry passengers until satisfactory credit drydock.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 July 2008
Resolved
Replace retroreflective tape on life preservers as needed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 17 July 2008
Resolved
Stencil lifering buoy near pilothouse and provide retroreflective tape on main deck lifering.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 July 2008
Resolved
Place covers on outlet receptacles on 0-1 deck as needed.
Documentation › Certificates/Documents › FCC SSL
Issued 17 July 2008
Resolved
Provide FCC Safety Certificate.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 17 July 2008
Resolved
Provide proof of deckhand in drug consortium.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 17 July 2008
Resolved
Provide up to date publications for navigation.
Engineering › Fuel Oil Service System › Ventilation
Issued 17 July 2008
Resolved
Provide screens for vents as needed.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 17 July 2008
Resolved
Provide cover for electrical boxes in engine room as needed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 July 2008
Resolved
Provide battery covers for batteries in engine room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 July 2008
Resolved
Provide guard for belt on generator.
Engineering › Steering Gear System › Rudder
Issued 17 July 2008
Resolved
Tighten, repair, or replace packing as needed on port side rudder post.
Engineering › Fuel Oil Service System › Filter
Issued 17 July 2008
Resolved
Provide shields for fuel filters.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 July 2008
Resolved
Provide visual indicator for automatic bilge pump in lazarett.
Documentation › Logs/Records › Drug Test Records
Issued 25 June 2007
Resolved
Provide proof of drug consortium for all members of crew and proof of drug testing.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 25 June 2007
Resolved
Place name on lifebuoy of vessel as required.
Engineering › Diesel Engine (propulsion-electric) › Crosshead Assembly
Issued 25 June 2007
Resolved
Show proof of proper installation of new heat exchanger on generator.
Documentation › Markings/Placards › Lifejacket Placard
Issued 13 April 2006
Resolved
Provide and post life jacket donning placards in a conspicuous location near life jacket stowage locations.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 13 April 2006
Resolved
Provide proof of EAP training for masters and crew.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 2 November 2005
Resolved
Repair the crack in the hub of the stbd side propeller.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 November 2005
Resolved
Replace the aft cutlass bearing on the portside shaft.
Engineering › Steering Gear System › Rudder Stock
Issued 2 November 2005
Resolved
Replace port and stbd side seals/packing on upper rudder posts.
Engineering › Sea-water System (primary cooling) › Valve
Issued 2 November 2005
Resolved
Remove scale build up from both sea valves coming from the port and stbd sea chest.
Documentation › Certificates/Documents › FCC SSL
Issued 12 July 2004
Resolved
Provide valid FCC Safety Radio Telephony Certificate, vessel limited to no more than 1000 feet from shore.
Documentation › Logs/Records
Issued 22 May 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Manuals/Policy Documentation
Issued 4 December 2002
Resolved
PROVIDE PROOF OF A DAPI PROGRAM. LEGACY COMPONENT DESC: DAPI
Documentation › Manuals/Policy Documentation
Issued 4 December 2002
Resolved
PROVIDE PROOF OF CPR TRAINING. LEGACY COMPONENT DESC: CPR DOCUMENTATION.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 4 December 2002
Resolved
CO2 PULL BOX FOR FIXED FIRE FIGHTING SYSTEM NOT STENCILED. LEGACY COMPONENT DESC: Operating Controls
Accommodation/Occupational Safety › Occupational Safety
Issued 4 December 2002
Resolved
INSTALL AT RAIL AREA 02 DECK PORT SIDE. LEGACY COMPONENT DESC: Deck Rail
Engineering › Bilge Water Management System
Issued 4 December 2002
Resolved
INSTALL A HIGH BILGE ALARM SENSOR IN TRANSDUCER COMPARTMENT. LEGACY COMPONENT DESC: HIGH BILGE ALARM
Navigation › Piloting/Steering
Issued 4 December 2002
Resolved
REPAIR COMPASS LIGHT. LEGACY COMPONENT DESC: Magnetic Compass
Lifesaving › Lifebuoys
Issued 4 December 2002
Resolved
ARANGE RING BOUY FOR QUICK RELEASE. LEGACY COMPONENT DESC: Stowage
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 December 2002
Resolved
STENCIL ALL LIFEJACKETS WITH VESSSEL NAME. LEGACY COMPONENT DESC: Marking
Electrical › Electrical Distribution System (service)
Issued 4 December 2002
Resolved
WIRING PIERCING ENGINEROOM BULKHEAD NOT MADE WATERTIGHT. LEGACY COMPONENT DESC: Wiring
Pollution Prevention/Response › Prevention Equipment
Issued 22 April 2002
Resolved
Make ID placards on MSD tanks legible. MSD system shall not be used until inspection completed by CG marine inspector. LEGACY COMPONENT DESC: Sewage System Tank
Pollution Prevention/Response › Prevention Equipment
Issued 22 April 2002
Resolved
Provide instruction manual for MSD. MSD shall not be used until inspection is completed by CG marine inspector. LEGACY COMPONENT DESC: Sewage System Tank
Lifesaving
Issued 16 April 2001
Resolved
MARK LIFE JACKET STOWAGE AREAS ON UPPER DECK AND MAIN DECK WITH SIZE AND NUMBER.
Engineering
Issued 16 April 2001
Resolved
MARK REMOTE FUEL SHUTOFF VALVE STATION INDICATING PURPOSE AND DIRECTION OF OPERATION.
Documentation
Issued 19 April 1999
Resolved
PROVIDE CURRENT AND ACCURATE CALL SIGN FOR VESSEL AND CORRECT FCC STATION LICENSE AND/OR RADIOTELPHONE SAFETY CERTIFICATE REFLECT CURRENT CALL SIGN.
Navigation
Issued 3 April 1997
Resolved
PROVIDE CURRENT NAVIGATION PUBLICATIONS. _x001C_ 46CFR184.420
Navigation
Issued 3 April 1997
Resolved
REPAIR OR REMOVE DEFECTIVE RUDDER ANGLE INDICATOR.
Navigation
Issued 3 April 1997
Resolved
DEMONSTRATE PROPER OPERATION OF VHF RADIOS.
Lifesaving
Issued 3 April 1997
Resolved
LABEL CHILD LIFEJACKET STOWAGE. _x001C_ 46CFR180.78(a)(5)
Lifesaving
Issued 3 April 1997
Resolved
UPDATE FIRST AID KIT PER 46 CFR 184.710.
Engineering
Issued 3 April 1997
Resolved
INSTALL HEAT IMPINGEMENT SHIELD ON STARBOARD MAIN DIESEL ENGINE FUEL OIL FILTER.
Lifesaving
Issued 3 April 1997
Resolved
PROPERLY ATTACH FLOAT LIGHT TO RING BUOY; PROPERLY MARK RING BUOY STOWED BEHIND BRIDGE. 46CFR185.604(b); 46CFR180.70(d)(2)
Documentation
Issued 3 April 1997
Resolved
PROVIDE AND POST VESSEL'S STABILITY LETTER PER 46CFR176.306 PRIOR TO CARRIAGE OF PASSENGERS.
Documentation
Issued 15 April 1994
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION WITH NEW OWNER INFORMATION._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 15 April 1994
Resolved
DEMONSTRATE CREW COMPETANCY DRILLS._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 15 April 1994
Resolved
APPLY FOR NEW ROUTE AND OPERATING CONDITIONS IN ACCORDANCE WITH LOCAL [name withheld].
Lifesaving
Issued 15 April 1994
Resolved
REMARK ALL LIFESAVING GEAR WITH VESSEL'S NEW NAME.
Unknown
Issued 15 April 1994
Resolved
RE-ATTACH PILOT HOUSE TOP AND STACKS.
Engineering
Issued 14 May 1991
Resolved
DEMONSTRATE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE.
Lifesaving
Issued 22 May 1989
Resolved
PROVIDE SIX (6) ORANGE FLARES PRIOR TO CARRYING PASSENGERS.
Navigation
Issued 22 May 1989
Resolved
PROVIDE BELL
Unknown
Issued 22 May 1989
Resolved
POST EMERGENCY CHECK-OFF LIST FOR PASSENGERS.
Lifesaving
Issued 22 May 1989
Resolved
PROVIDE BATTERY FOR RINGBUOY FLOAT LIGHT.
Lifesaving
Issued 22 May 1989
Resolved
PROVIDE EMERGENCY LIGHT FOR ENGINE ROOM.
Engineering
Issued 22 May 1989
Resolved
REMOVE PETCOCKS FROM RAYCOR FUEL FILTERS AND INSTALL PLUGS.
Fire Fighting
Issued 17 May 1988
Resolved
RENEW THE 25 SECOND TIME DELAY ON THE FIXED EXTINGUISHING SYSTEM.
Electrical
Issued 17 May 1988
Resolved
INSTALL A LOCK ON THE MAIN ELECTRICAL PANEL IN THE MENS RESTROOM.
Navigation
Issued 17 May 1988
Resolved
INSTALL RUDDER STOPS TO PREVENT TUBELOCKING OF THE STEERING SYSTEM.
Electrical
Issued 4 April 1986
Resolved
INSTALL SOLDER TYPE CONNECTIONS FOR THE FOLLOWING: GENERATOR AND MAIN ENGINE BATTERY CONNECTIONS, STARTER CONNECTION, AND BATTERY GROUND TO ENGINE BLOCK CONNECTION.
Lifesaving
Issued 5 April 1985
Resolved
PROVIDE 11 C.G.APPROVED ADULT PFD'S.
Casualty record · 1
11 July 2009Routine · role: Involved in a Marine Casualty · activity 3533647
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
CITY OF FREDERICKSBURG (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.