Records from 1985 to 2003. Most recent: inspection, 7 May 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 28
7 May 2003
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1788279
16 April 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1604814
7 March 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1490822
24 April 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1466777
4 May 2000
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1051044
7 April 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1408492
6 March 2000
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1471220
15 April 1999
COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1126333
15 April 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1124068
11 April 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1400543
25 March 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1454428
18 April 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1387995
18 April 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416120
9 January 1995
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 856944
26 April 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1332538
2 November 1993
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 851737
25 March 1993
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1149753
29 April 1992
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1266742
29 April 1992
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1471281
6 June 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 890377
6 June 1991
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1200975
15 October 1990
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 915489
1 May 1990
COI Inspection · Drydock Extension
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 910852
24 May 1989
Drydock Extension · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1033515
21 May 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1032845
4 May 1987
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1029695
21 April 1986
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1306494
14 May 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1291436
Lifesaving › Buoyant Apparatus
Issued 16 April 2002
Resolved
RENEW BUOYANT APPARATUS GRABLINES AND SEA PAINTER.
Due 16 May 2002
Resolved 17 April 2002
Navigation › Piloting/Steering › Marine Charts
Issued 16 April 2002
Resolved
RENEW CHARTS.
Due 16 May 2002
Resolved 17 April 2002
Communications › Alarms/Indicators › High Water Alarm
Issued 16 April 2002
Resolved
LABEL HIGH WATER ALARMS.
Due 16 May 2002
Resolved 17 April 2002
Navigation
Issued 7 April 2000
Resolved
UPDATE CHARTS AND TIDE TABLES
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Lifesaving
Issued 7 April 2000
Resolved
REPLACE GRABLINE ON RING BUOY.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Lifesaving
Issued 7 April 2000
Resolved
REPLACE FADED REFLECTIVE TAPE.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Lifesaving
Issued 7 April 2000
Resolved
UPDATE EXPIRED MEDICATIONS IN 1ST AID KIT.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Deck/Cargo
Issued 6 March 2000
Resolved
REPLACE MISSING BOLTS FROM THE PULLEY FOR THE ANCHOR ON THE BOWSPRIT.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 6 March 2000
Resolved
PROVIDE CAPTIVE CHAINS FOR ALL HATCH COVERS.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 6 March 2000
Resolved
DOUBLE CLAMP THE SEA-SUCTION WASH DOWN HOSE.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Electrical
Issued 6 March 2000
Resolved
ENSURE ALL WIRING CONNECTIONS ARE MADE IN AN ENCLOSURE. 46 CFR 183.05-50 OLD T.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Construction/Loadline
Issued 6 March 2000
Resolved
PROVIDE A RUBBER GASKET ON BOTTOM OF ENGINE BOX, AND A SECURING DEVICE ON SIDE OPPOSITE OF THE HINGES ON THE BOX. 46 CFR 171.124(A)(1) - OLD T.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Accommodation/Occupational Safety
Issued 6 March 2000
Resolved
TIGHTEN ALL RAIL STANCHIONS THROUGH THE WASHBOARDS.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Documentation
Issued 6 March 2000
Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Electrical
Issued 6 March 2000
Resolved
PROVIDE GLOBE FOR OVERHEAD LIGHT IN HEAD. 46 CFR 183.410 (A).
Condition: Unknown
Due 6 March 2000
Resolved 6 March 2000
Lifesaving
Issued 11 April 1997
Resolved
Buoyant apparatus needs to have number of persons stencialed on side.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Navigation
Issued 11 April 1997
Resolved
Needs updated Coast Pilot.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Documentation
Issued 25 March 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 June 1993
Resolved 11 June 1993
Documentation
Issued 25 March 1993
Resolved
DRUG PLAN INITIATED. 835 ISSUED TO COMPLETE FINAL REQUIREMENTS, (TRAINING, POSTING POLICY, HOTLINE, HANDOUTS, ETC).
Condition: Unknown
Due 1 June 1993
Resolved 11 June 1993
Documentation
Issued 25 March 1993
Resolved
NO FCC SAFETY CERTIFICATE ON BOARD. 835 ISSUED TO OBTAIN BY 01JUN93.
Condition: Unknown
Due 1 June 1993
Resolved 11 June 1993
Navigation
Issued 29 April 1992
Resolved
OBTAIN TIDE TABLES FOR 1992
Condition: Unknown
Due 7 May 1992
Resolved 12 May 1992
Documentation
Issued 29 April 1992
Resolved
OBTAIN AND DISPLAY FCC OPERATORS LICENSE
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 29 April 1992
Resolved
REPAIR/REPLACE WATERLIGHT FOR B/A
Condition: Unknown
Due 30 May 1992
Resolved 12 May 1992
Fire Fighting
Issued 29 April 1992
Resolved
SERVICE PORTABLE FIRE EXTINGUISHING EQUIP.
Condition: Unknown
Due 30 May 1992
Resolved 12 May 1992
Accommodation/Occupational Safety
Issued 29 April 1992
Resolved
PROVIDE INSTRUCTIONS FOR DAWNING PFDS AND MOUNT IN AN AREA PASSENGERS CAN VIEW
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Electrical
Issued 29 April 1992
Resolved
PROVIDE ONE FLASHLIGHT FOR EMERGENCY LIGHTING
Condition: Unknown
Due 7 May 1992
Resolved 12 May 1992
Engineering
Issued 29 April 1992
Resolved
INSTALL 30 X 30 WIRE MESH IN FUEL VENTS
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Unknown
Issued 29 April 1992
Resolved
IMPLEMENT A DRUG TESTING POLICY
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Navigation
Issued 29 April 1992
Resolved
INCREASE HEIGHT OF ANCHOR LIGHT
Condition: Unknown
Due 30 May 1992
Resolved 12 May 1992
Lifesaving
Issued 29 April 1992
Resolved
PROVIDE VENTILATION FOR PFD STOWAGE AREA
Condition: Unknown
Due 7 May 1992
Resolved 12 May 1992
Lifesaving
Issued 29 April 1992
Resolved
INSTALL RETRO REFLECTIVE TAPE ON BUOYANT APPARATUS
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Electrical
Issued 29 April 1992
Resolved
REDO ELECTRICAL CONNECTION AS NOTED BY INSPECTOR AND ANY OTHERS NOT CORRECT
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Navigation
Issued 6 June 1991
Resolved
PROVIDE 1991 TIDE TABLES
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Lifesaving
Issued 6 June 1991
Resolved
PROVIDE ONE ADULT LIFE PRESERVER. UNTIL REQUIREMENT IS MET, TOTAL PERSONS ALLOWED IS LIMITED TO 19
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Navigation
Issued 6 June 1991
Resolved
REPAIR MASTHEAD RUNNING LIGHT
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Documentation
Issued 1 May 1990
Resolved
SUBMIT A LTR TO THE COAST GUARD STATING THAT YOUR DRUG TESTING PROGRAM HAS BEEN STARTED BY 21DEC90
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
INSTALL HEAT SHIELD ON RACOR FUEL FILTER
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Lifesaving
Issued 1 May 1990
Resolved
PROVIDE SIX EACH, CURRENT RED AND ORANGE FLARES
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Documentation
Issued 1 May 1990
Resolved
PROVIDE CURRENT FCC OP LIC
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Documentation
Issued 1 May 1990
Resolved
POST EMER CHECK LIST
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 24 May 1989
Resolved
COMPLETE ENGINEROOM VENTILATION INSTALLATION
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Fire Fighting
Issued 24 May 1989
Resolved
PROVIDE TWO SERVICED HYDROED B-II PORTABLE FIRE EXTINGUISHERS
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Navigation
Issued 24 May 1989
Resolved
REPLACE FADED LENSES IN BOTH SIDELIGHTS
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Lifesaving
Issued 24 May 1989
Resolved
PROVIDE CORRECT SIZE WEAKLINK FOR BUOY APPARATUS
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Navigation
Issued 24 May 1989
Resolved
REPAIR/REPLACE STERN LIGHT
Condition: Unknown
Due 24 May 1989
Resolved 24 May 1989
Lifesaving
Issued 4 May 1987
Resolved
PROVIDE PENANTS EVERY 18" AROUND BUOYANT APPARATUS. PENDANT SHALL BE 1/4" DIAMETER AND 12' LONG.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987
Resolved
RENEW LIFELINE AROUND BUOYANT APPARATUS. LINE SHALL BE 3/8" DIAMETER, DARKIN COLOR OR RESISTENT TO SUNLIGHT.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987
Resolved
PROVIDE OPERATING WATER LIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Construction/Loadline
Issued 4 May 1987
Resolved
PROVIDE CAPTIVE CHAIN FOR TWO DECK HATCHES AND MEANS OF SECURING ENGINE BOX
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Electrical
Issued 4 May 1987
Resolved
PROPERLY BLOCK TWO BATTERIES.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Engineering
Issued 4 May 1987
Resolved
DEMONSTRATE PROPER OPERATION OF PROPULSION MACHINERY.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Construction/Loadline
Issued 4 May 1987
Resolved
RENEW BILGE LINE TO TWO ELECTRIC BILGE PUMPS. REPLACEMENT MAY BE METALLIC,RIGID NON-METALLIC OR NON-RIGID, NON-METALLIC. THE LATTER SHALL BE RTEINFORCED AND RESISTENT TO PETROLEUM PRODUCTS. MANU-FACTURERS SPECIFICATION SHALL BE PROVIDED TO DEMONSTRATE RESISTENCE TO
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Engineering
Issued 4 May 1987
Resolved
RENEW FLEXIBLE FUE HOSE.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987
Resolved
PROPERLY MARK N'S OF D LOCKERS.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Engineering
Issued 4 May 1987
Resolved
PROPERLY MARK EMERGENCY SHUT-OFF VALVES.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Electrical
Issued 4 May 1987
Resolved
PERMANENTLY WIRE REFRIGERATOR.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987
Resolved
PROVIDE 2-2X4" STRIPS OF RETRO-REFLECTIVE MATERIAL ON EACH SIDE OF ALL PFD'S.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Engineering
Issued 4 May 1987
Resolved
RENEW FUEL TANK VENT SCREENS.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987
Resolved
RENEW LIFELINE AROUND RING BUOY. LINE SHOULD BE 3/8" DIAMETER, POLYETHLENEPROPYLINE OR BUOYANT SYNTHETIC MATERIAL.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987