MAURY USCG vessel records Sign in
← All vessels

KINUGAWA

KINUGAWA is a 1984 tank ship. The Coast Guard has recorded 75 inspections since 1985, most recently in November 2008, along with 76 deficiencies and 3 operational controls.

Records from 1985 to 2008. Most recent: inspection, 4 November 2008.

Built
1984
Last inspected
4 November 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8307997 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
244325
Flag
PANAMA
—
Maury page id
psix-244325

Inspections, by type

…with no type recorded41
Years with a record 20 calendar years (1985–2008)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14273 - Convention (Subpart B), Gross Ton
8454 - Convention (Subpart B), Net Ton
24734 - Dead Weight, Ton
31775 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KRNW-1 Freight Barge · MISLE 49812 · 24 September 1997 · activity 532090

Inspection history · 75

4 November 2008 MARPOL Annex V Examination · MARPOL Annex I Examination · MARPOL Annex II Examination · ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3354221
26 June 2008 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3248967
18 April 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3187010
16 April 2008 Ballast Water Examination · ISPS II Exam · COC-CHEM Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3176403
14 November 2007 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3098383
11 September 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3055298
10 June 2007 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2956720
18 May 2007 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2933785
27 March 2007 COC-CHEM Renew · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2895863
4 January 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2850189
8 June 2006 Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2674180
22 March 2006 COC-CHEM Annual · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2604839
18 January 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2569027
17 January 2006 Type not recorded
No type recorded · Maritime Safety & Security Team LA/LB (91103) · Activity 2568464
16 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2567518
12 July 2005 Ballast Water Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2427664
22 February 2005 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · COC-CHEM Annual
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2295213
14 June 2004 Administrative Inspection
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2097906
5 June 2004 Type not recorded
No type recorded · GROUP SEATTLE · USCG Northwest District (CGD-NW) · Activity 2089386
3 June 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2086670
21 March 2004 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2027503
21 August 2003 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2034992
14 June 2003 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1817338
9 April 2003 Type not recorded
No type recorded · GROUP LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1770726
4 April 2003 Ballast Water Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1768400
2 December 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1714011
25 September 2002 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1680304
17 July 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 280062
17 July 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1429384
30 November 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274389
30 November 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 435321
2 August 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 431320
1 August 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274487
1 August 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 812663
14 March 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 426242
26 October 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 421941
18 June 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 416977
24 September 1997 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 532090
23 September 1997 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 408274
23 September 1997 Administrative
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1115030
12 June 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 404760
12 June 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 781495
15 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 397232
15 November 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1097160
15 November 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1175932
5 June 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1220073
1 May 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 378086
18 October 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 646827
15 September 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 834667
13 September 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360867
13 September 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 646824
8 September 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 360758
28 October 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246673
18 November 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 333683
18 November 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1222056
16 June 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 489260
16 June 1989 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 897036
14 February 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 436749
27 January 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328264
27 January 1989 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341343
2 July 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896360
30 March 1988 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 993222
2 December 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 496893
30 September 1987 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1009761
27 May 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001165
20 May 1987 MARPOL Annex II Examination · Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1332587
5 February 1987 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1010321
13 November 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 312646
13 November 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1006433
26 August 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1299064
24 February 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 451387
6 June 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 504746
4 June 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 302466
28 May 1985 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 978332
5 January 1985 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 508411

Deficiency record · 76

Communications › Alarms/Indicators › Steering Failure Alarm System
Issued 4 November 2008 Resolved
Steering gear No.1 was not operating as designed. During the steering gear test, the no voltage visual alarm did not work.
Action required: 705 - Other - as specified
Due 4 November 2008
Resolved 4 November 2008
Resolution: Vessel repaired deficiency while PSCO was on board.
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 10 June 2007 Resolved
The ground to a washing machine located in the upper deck laundry room sawed off. Washing machine has now been removed from service. SOLAS 2004 CH II - 1 Reg 45
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 11 June 2007
Resolved 11 June 2007
Resolution: The machine has been remover from service and placed in Ship''s store room.
Documentation › Logs/Records › Cargo Record Book (NLS)
Issued 10 June 2007 Resolved
Cargo Record Book missing name of cargo under the A2 code on MARPOL Annex I 20 May, 22May, 25 May 07
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 June 2007
Resolved 11 June 2007
Resolution: The corrections were made and signed of by the Captain
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 10 June 2007 Resolved
No heat protection on exhaust pipe to emergency fire pump located in stearing gear room SOLAS 2004 Ch II-1 Reg 26 Rectify deficiencies prior to next US Port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 20 November 2007
Resolution: Heat protection was fitted upon the emergency fire pump exhaust pipe and approved by class.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 10 June 2007 Resolved
No machine guard on Emergency Fire Pump. Belt completely exposed SOLAS 2004 Ch II-1 Reg 26 Rectify deficiencies prior to next US Port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 July 2007
Resolved 21 November 2007
Resolution: A machinery guard was fitted on the emergency fire pump and approved by class.
Lifesaving › Launching Appliances › Davit
Issued 27 March 2007 Resolved
Port lifeboat davit was out of alignment, causing the falls to chafe against the davit arm as it is resting in cradled position & when lifeboat is lowered. When lifeboat was lowered ,aft skate of lifeboat struck the deck edge & broke skate from boat b/c boat was at angle to deck. Alignment of davit & proper operation must be addressed to satisfaction of class/flag representative prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Resolution: According to the instruction from Flag State Ref. No. MDG07/02/44 dated 29 March 2007, an additional 2 certified life rafts 1 X 16 and 1 X 20 were provided on board. The repairs to the davits will be made by 28JUN07 to satisfaction of Class.
Fire Fighting › Fire Pumps › Pressure
Issued 27 March 2007 Resolved
During the first test of the emergency fire pump, discharge pressure was 2 bars and was insufficient to provide firefighting water to 2 hoses. The crew was unsure how to increase pressure. The pump subsequently failed and is inoperable with no spare parts onboard. Address repairs to the satisfaction of class/flag rep prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Resolution: Class verified the repair of the fire pump. The reason for the failure was a clog of the exhaust pipe, and a broken ratchet wheel and misadjusted governor.
Electrical › Electric Supply System (service) › Cable
Issued 27 March 2007 Resolved
Numerous problems with electrical wiring and fixtures were found throughout the vessel including broken/missing covers, loose fixtures with lights hanging, electrical boxes P/S in disrepair, and pumps with loose wires in the engine room. Wire must be repaired and covers replaces to satisfaction of class/flag rep.
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 5 April 2007
Resolution: Received faxed class report indicating light covers were replaced, electrical plug boxes were repaired, and electrical wiring on pump motor of boiler and solenoid valve for boiler burner was repaired.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 March 2007 Resolved
Patches were found on the following main deck pipes with no reports to company or repair plans: #3 fuel oil tank pipe on port side, #2 port CP pipe vent. ISM Code Part A 10; SOLAS 74 (81am) II-1/40
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 5 April 2007
Resolution: Received faxed class report detailing that #3 port fuel tank was renewed and #2 port fuel tank found to be normal after anti-rust tape was removed.
Lifesaving › Lifebuoys › Serviceable
Issued 27 March 2007 Resolved
Port lifebuoy on bridge wing needs a 3 meter line added between the smoke/light combination and the buoy in order to properly operate the quick releasing device. One lifebuoy on the starboard side aft needs retro reflective tape (LSA Code I/1.2.2.7)
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Items inspected and approved by Class.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 27 March 2007 Resolved
BWM Handling log in use is not the same form as the handling log required in the BWM Plan. C/O is giving training to crew and signing verification against company policy that requires master/witness to verify training, ISM Code Part A 11.3
Action required: 705 - Other - as specified
Resolved 30 March 2007
Resolution: Item was corrected on the spot to the satisfaction of the USCG Marine Inspector.
Documentation › Logs/Records › Oil Record Book
Issued 27 March 2007 Resolved
ORB date are missing from some operations that were signed by the C/E. Cargo record book dates and C/O signatures were missing for several operations. MARPOL I/17; MARPOL II/15
Action required: 705 - Other - as specified
Resolved 27 March 2007
Resolution: Corrected on the spot to the satisfaction of the USCG Marine Inspector.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 27 March 2007 Resolved
High level alarm on flying bridge is not labeled; must be labeled with 2" black letters on white background. 46CFR39.20-7(c)(2)
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: High Level Alarm has been marked and inspected by the Class Representative.
Deck/Cargo › Holds/Tanks › Tank Level Monitoring Device
Issued 27 March 2007 Resolved
Tank overfill alarm is not marked on the flying bridge and must be marked by a sign with 2" black letters on a white background. 46CFR39.20-7(d)(3)
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Overfill Alarm has been marked and inspected by Class.
Fire Fighting › Ventilation Systems › Ducts
Issued 27 March 2007 Resolved
Air conditioning ducting is wasted in air conditioning room. Door to air conditioning room space is not weathertight & needs a new gasket. SOLAS 74 (81am) II-2/48
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 5 April 2007
Resolution: Received faxed class report detailing that gasket packing for the door was renewed. The air conditioner ducting was temporarily repaired to the satisfaction of class, with permanent repair plans due by the next Docking Survey on 18 August 2007.
Operations/Management › Cargo Transfer/Lightering › Pre-transfer Inspection
Issued 27 March 2007 Resolved
Eye wash stations on main deck are not being maintained. No continuous stream of water is produced when turned on. Emergency shower amidships main deck is not operable. 46CFR153.216; BCH V/3.16.12
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Eye wash stations have been inspected and tested to the satisfaction of Class.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 27 March 2007 Resolved
Scupper plugs throughout the deck area do not fit properly. A mechanical means of closure must be used that is capable of preventing spillage from the deck. 33CFR155.310(b)(3)
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Items have been inspected and tested to the satisfaction of Class.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 27 March 2007 Resolved
Several doors throughout the vessel do not close properly and compromise A boundaries. Doors leading from galley to stairwell down to provision stores does not close properly; door frame is bent. Upper deck door "up" stairwell does not close properly, despite having self closing devices. SOLAS 74(81am) II-2/47.1
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Doors have been inspected by Class and found in satisfactory condition.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 27 March 2007 Resolved
Fuel tank for emergency fire pump is patched and leaking. The tank was found below half full and connection to fuel oil pump was leaking. Permanent repairs must be addressed to the satisfaction of class society/flag representative. SOLAS 74(81am) II-2/4.3.3.2.4
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 5 April 2007
Resolution: Received faxed class report indicating that connecting pipe and tank were re-welded properly and found in good order.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 March 2007 Resolved
Sewage treatment plant maintenance/test procedures are not being conducted by the crew in accordance with the manufacturer's daily/weekly/monthly/semi-annual/annual inspections/tests that are required for proper operation of the system. 33CFR159.121(b). Address to the satisfaction of class/flag rep.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2007
Resolution: A ship specific PMS system has been implemented by the management company.
Construction/Loadline › Structures › Machinery Space Opening
Issued 27 March 2007 Resolved
Funnel doors need adjusting - one door cannot be closed without difficulty & use of dogging wrench; gasket is worn & dogs need to be adjusted to ensure integrity of fire boundary. Top of funnel, aft, stbd side, is wasted/holed, allowing air/water to enter the space freely, breaking watertight/fire boundary. Address to satisfaction of class/flag rep. ICLL 66 17 SOLAS 74(81am) II-2/47
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 5 April 2007
Resolution: Received faxed class report confirming that the funnel door gasket packing and hinge pins were renewed. Hole in funnel was repaired by a welded double plate.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 27 March 2007 Resolved
2 Fireman's outfits have parts that are in disrepair and cause an excessive personnel hazard; Neck cover attached to helmet is wasted & torn on suit stowed on stbd bridgewing; jacket is ripped through for 5" on left side. No spares are available onboard. Damaged pieces shall be replaced to the satisfaction of class/flag rep prior to departure. SOLAS 74 (81am) II-2/17
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Resolution: Three new sets were purchased and inspected by Class.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 27 March 2007 Resolved
Garbage management plan is not be adhered to: cans are not designated w/ proper labels/color coding & mixed garbage was found throughout the vessel. Segregation must be followed in accordance with plan. Address to the satisfaction of class/flag rep. MARPOL V/9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 May 2007
Resolution: Ship Management Company has reviewed the requirements and have required in-depth garbage training for all crewmembers. The ship''s collection cans have all been remarked and placed throughout the vessel according to the garbage plan.
Construction/Loadline › Structures › Scuttle
Issued 27 March 2007 Resolved
Deadlight covers on sidescuttles in the lower deck crew toilet & shower rooms are frozen open in place and are not operable. Address to the satisfaction of class/flag rep. ICLL 66 Reg. 23
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Deadlight covers have been inspected and tested to the satisfaction of Class.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 27 March 2007 Resolved
Several A and B class boundaries are compromised: 6" crack in A-60 boundary btwn wxdeck & #2storeroom fwd, as well as a crack in reinforcement plate around the fire main leading into the same space; B class bulkhead btwn galley & ladder well to provision stores has 1' hole; B class bulkhead from port crew washroom holed; A class cover btwn E/R & provision stores is missing. SOLAS 74(am) II-2/44;
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 5 April 2007
Resolution: Received faxed class report indicating that cracks and holes were repaired by qualified shore side welders. A class cover between engineroom and provision store was fitted with bolts.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 27 March 2007 Resolved
Hospital space sink does not drain properly, though hot water faucet remained turned on for ~5 minutes it remained cold & brown/black in color. Drain began to back up from sink through deck drain in same space. ILO164 Art. 11
Action required: 705 - Other - as specified
Due 4 April 2007
Resolved 30 March 2007
Resolution: Item has been cleaned, inspected and tested to the satisfaction of Class.
Lifesaving › Launching Appliances › Davit
Issued 27 March 2007 Resolved
27Mar: Stbd lifeboat (rescue boat) could not be fully recovered after drill. Winch failed to recover boat. Crew then removed the winch motor from the port boat & install it on the stbd winch to recover the boat. 28Mar: Tested stbd winch, recovery was successful but extremely slow. Winch capability/arrangement must be inspected/tested to satisfaction of class/flag rep. SOLAS 74 III/36
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2007
Resolution: Confirmed the winch is working normally. The time of recovery is 2min 45sec.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 27 March 2007 Resolved
Based on observed reqmts for SMS, BWM plan & Garbage plan were not being followed IAW company procedures; defs 3, 6, 16, 20 did not have any reports to company or any planned repairs IAW the SMS. The COTP recommends an audit of the vessel's SMS by flag state or RO w/in 30 days. Should that audit be conducted, fax report to Sector SF at [phone withheld].
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 18 May 2007
Resolution: A SMS audit was carried out by [name withheld], Marine Safety Section, Ship Management Department, Unix Line Pte, Ltd.
Fire Fighting › Fire Main › Condition
Issued 22 March 2006 Resolved
Repair to the satisfaction of class the deck fire main where there are two leaks beneath two of the fire monitors.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2006
Resolved 23 March 2006
Fire Fighting › Fire Pumps › Suction Valve
Issued 22 March 2006 Resolved
Repair to the satisfaction of class the emergency fire pump suction valve remote valve where it was disabled by the crew.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2006
Resolved 23 March 2006
Engineering › Bilge Water Management System › Piping
Issued 22 March 2006 Resolved
Update the bilge piping diagram to depict the manual three way valve adjacent to the automatic three-way valve.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 June 2006
Resolution: Resolved via fax from class.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 22 March 2006 Resolved
Prove to the satisfaction of class the emergency generator, 70 litre fuel tank will provide adequate power for six hours for all required services.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 June 2006
Resolution: Resolved via fax from class
Electrical › Electric Generation Source (emergency) › Generator
Issued 22 March 2006 Resolved
Provide class approval for the location of the emergency generator where it is located below the upper most continuous deck.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 June 2006
Resolution: Resolved via fax from Class
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 22 February 2005 Resolved
#2 waste oil tank glass bullseye broken. Replace broken glass to the satisfaction of class. SOLAS I/II.
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 March 2005
Resolved 12 July 2005
Resolution: Sector LA/LB cleared by class report.
Stability › Watertight Integrity › General
Issued 22 February 2005 Resolved
Weathertight door leading aft on [name withheld] will not fully close, rendering the locking mechanism inoperable. Found door tied with rope in a locked position. SOLAS I/II.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 22 March 2005
Resolved 12 July 2005
Resolution: Sector LA/LB cleared by class report.
Fire Fighting › Structural - A Class Divisions
Issued 21 March 2004 Resolved
Ensure stairway door on Captain deck leading below to the Bridge deck can close and latch shut prior to next US port after sailing foreign. SOLAS 74 II-2/57.b.vii Note: Door will close but will not latch shut. LEGACY COMPONENT DESC: Openings - Fire Doors
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 June 2004
Resolution: Vessel has purchased new firefighting outfits to correct the deficiency.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 April 2003 Resolved
Broken railing on starboard bow and broken rail and support frame starboard amidships. ILLC 66 Annex 1/15 LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 June 2003
Resolution: Replaced broken rail with new railing
Deck/Cargo › Inert Gas System
Issued 25 September 2002 Resolved
IGS is inoperable. Vessel is above 20,000 deadweight tons and must have an Inert Gas System onboard if carrying oil products with a flashpoint over 60 degrees C. Class has addressed issue and vessel has outstanding requirement to have IGS tested prior to carrying oils with a flashpoint over 60C.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2002
Resolution: Vessel reclassed to carry cargoes with flashpoint over 60C until Jan 29, 2003.
Accommodation/Occupational Safety
Issued 17 July 2000 Resolved
ILO 147, DEFICIENCY DESCRIPTION, CREW TOILET ON MAIN DECK, PORT SIDE DOES NOT MEET PROPER SANITATION REQUIREMENTS.
Condition: Unknown
Due 17 December 2001
Resolved 17 July 2000
Navigation
Issued 2 August 1999 Resolved
Ensure all charts for the San Francisco Bay are corrected prior to return to US from overseas. 33 CFR 164.33(a)(ii)
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Documentation
Issued 2 August 1999 Resolved
Ensure the Safety Equipment supplement, form E, for the liferafts reflect what is aboard the vessel prior to next US port from ovreseas. SOLAS 74 ammended ch I Reg 12.
Condition: Unknown
Due 1 December 1999
Resolved 1 December 1999
Deck/Cargo
Issued 12 June 1997 Resolved
Secure the hydraulic oil leaks on the cargo deck booster pump prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 151.10.b
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Fire Fighting
Issued 12 June 1997 Resolved
Replace the missing closure device on the fire door to the steering gear / emergency fire pump space and assure door remains closed prior to return toa U. S. port._x001C_ SOLAS 74 II-2/20
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Electrical
Issued 12 June 1997 Resolved
Replace the missing cover over the explosion proof light in the emergency battery space prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Engineering
Issued 12 June 1997 Resolved
Repair the broken & hanging oil stop solenoid valves on the auxiliary boiler burners and assure the wiring is properly secured prior to return toa U. S. port._x001C_ SOLAS 74 II-1/27
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Lifesaving
Issued 12 June 1997 Resolved
Replace the missing belt drive cover over the air bottle compressor prior to return to a U. S. port. _x001C_ _x001C_ BCH 3.16
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Lifesaving
Issued 12 June 1997 Resolved
Completely overhaul or replace the starboard lifeboat prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 III/35
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Lifesaving
Issued 12 June 1997 Resolved
Provide a fire / WX resistant cover for the port lifeboat engine prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 III/9.a
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Construction/Loadline
Issued 12 June 1997 Resolved
Remove the cement box in the stbd, fwd bilge of the pump room and effect proper repairs to the pipe tunnel air vent line prior to return to a U. S. port. _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Engineering
Issued 12 June 1997 Resolved
Make permanent repairs to the wasted OWS tanks prior to return to a U. S. port. _x001C_ _x001C_ MARPOL 73/78 I/16
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Deck/Cargo
Issued 12 June 1997 Resolved
Disassemble and overhaul all cargo tank pressure vacuum valves prior to anyfuture cargo operations in U. S. waters. _x001C_ _x001C_ BCH 2.13
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Deck/Cargo
Issued 12 June 1997 Resolved
Prove proper operation of all cargo tank high level and overflow indicatorsprior to return to a U. S. port. _x001C_ _x001C_ BCH 3.9
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Accommodation/Occupational Safety
Issued 12 June 1997 Resolved
Remove the wooden decking about the upper WX deck walkways and foam monitors and replace with a fire resistant material prior to return to a U.S. port. _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Fire Fighting
Issued 12 June 1997 Resolved
Free up the operation of all foam monitor stop valves, to allow them to completely close, prior to departure._x001C_ _x001C_ SOLAS 74 II-2/61
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Engineering
Issued 12 June 1997 Resolved
Make permanent repairs to the wasted cooling piping about the port & centergenerator engines prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 24 September 1997
Resolved 24 September 1997
Electrical
Issued 12 June 1997 Resolved
Repair the oil leak on the filter of the steering gear emergency generator and the D/O leak about the sight glass to the fuel tank prior to departure._x001C_ SOLAS 74 I/11
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Deck/Cargo
Issued 15 November 1996 Resolved
PROVIDE CARGO PUMP ROOM READY FOR INSPECTION WITH THE TOLULENE LEVEL AT OR BELOW 10PPM, BY NEXT U.S. PORT CALL.
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Lifesaving
Issued 15 November 1996 Resolved
FREE UP 3 SIEZED SHEAVES ON THE STBD LIFEBOAT DAVIT, PRIOR TO NEXT U.S. PORT CALL. SOLAS CHAP III REG 48(1).
Condition: Unknown
Due 27 July 1997
Resolved 27 July 1997
Engineering
Issued 5 June 1995 Resolved
REPAIR AND PROVE PROPER OPERATION OF ENGINE ROOM OILY WATER SEPARATOR.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Documentation
Issued 15 September 1993 Resolved
PRIOR TO NEXT U. S. PORT, PROVIDE CORRECT OWNER AND OPERATOR DOCUMENTATION.
Condition: Unknown
Due 15 September 1993
Resolved 23 September 1993
Documentation
Issued 15 September 1993 Resolved
PROVIDE ONBOARD VALID SUBCHAPTER 'O' ENDORSEMENT.
Condition: Unknown
Due 15 September 1993
Resolved 23 September 1993
Lifesaving
Issued 15 September 1993 Resolved
PRIOR TO NEXT U. S. PORT PROVIDE DOCUMENTATION THAT SCBAS HAVE BEEN PROFESSIONALLY SERVICED YEARLY.
Condition: Unknown
Due 15 September 1993
Resolved 23 September 1993
Deck/Cargo
Issued 15 September 1993 Resolved
PRIOR TO NEXT U. S. PORT, DEMONSTRATE PROPER OPERATION OF CARGO HIGH LEVEL ALARM.
Condition: Unknown
Due 15 September 1993
Resolved 23 September 1993
Fire Fighting
Issued 15 September 1993 Resolved
PRIOR TO NEXT U.S. PORT PROVIDE DOCUMENTATION THAT FIRE FIGHTING FOAM IS PROPER TYPE FOR CARGO ONBOARD.
Condition: Unknown
Due 15 September 1993
Resolved 23 September 1993
Unknown
Issued 8 September 1993 Resolved
VESSEL DISCHARGED GARBAGE & PLASTICS WITHIN THE EEZ OF THE US. THIS BASED UPON STATEMENT OF MASTER M/V RICH WORLD, REVIEW OF GARBAGE DISPOSAL LOG, & EVALUATION OF SHIP'S POSITION AT THE TIME AND OBSERVATION OF VOLUME OF PLASTICS AND GARBAGE ABOARD VESSEL.
Condition: Unknown
Due 8 September 1993
Resolved 24 September 1993
Navigation
Issued 8 September 1993 Resolved
Vessel did not have proper chart for safe navigation into the Port of Jacksonville.
Condition: Unknown
Due 5 November 1993
Resolved 5 November 1993
Navigation
Issued 8 September 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 September 1993
Resolved 13 September 1993
Deck/Cargo
Issued 27 January 1989 Resolved
REPAIR AND TEST HIGH LEVEL ALARMS TO STARBOARD CARGO TANKS #3 AND #5, STARBOARD SLOP TANK AND #2 CENTER CARGO TANK IN ACCORDANCE WITH 46 CFR 153.409.
Condition: Unknown
Due 27 January 1989
Resolved 27 January 1989
Deck/Cargo
Issued 27 January 1989 Resolved
CALIBRATE AND TEST INERT GAS SYSTEM IN ACCORDANCE WITH 46 CFR 32.53.
Condition: Unknown
Due 27 January 1989
Resolved 27 January 1989
Deck/Cargo
Issued 20 May 1987 Resolved
U.S. PORT OF CALL AFTER THE COMPLIANCE DATE UNLESS SPECIFICALLY WAIVED BY THE COGNIZANT COTP/OCMI.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Deck/Cargo
Issued 20 May 1987 Resolved
DEMONSTRATE TO A USCG MARINE INSPECTOR SATISFACTORY OPERATION OF THE IGS INCLUDING PROPER CALIBRATION OF O2 ANALYZER, AND SYSTEM OUTPUT OF < 5% O2. THIS TO BE DEMONSTRATED PRIOR TO CARRYING ANY CARGO REQUIRING INERTING, BUT, REGARDLESS OF CARGO, SHALL BE DEMONSTRATED AT FIRST (CONT. IDENT 2A)
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Documentation
Issued 20 May 1987 Resolved
SUBMIT COPY OF NEW IMO COF TO COMDT (G-MTH) AND OBTAIN & PLACE ON BOARD NEW SOE.
Condition: Unknown
Due 20 May 1987
Resolved 20 May 1987
Deck/Cargo
Issued 5 February 1987 Resolved
DEMONSTRATE PROPER OPERATION OF THE INERT GAS SYSTEM PRIOR TO CARRYING GRADE"D" CARGOES IN U. S. WATERS.
Condition: Unknown
Due 5 February 1987
Resolved 5 February 1987
Documentation
Issued 26 August 1986 Resolved
PRIOR TO ENTERING US WATERS AFTER 05SEP86 PROVIDE ON BOARD CURRENT COPIES OF THE COAST PILOT, CG LIGHT LIST, 33CFR1-199, 46CFR30-40 AND 46CFR140-155.
Condition: Unknown
Due 26 August 1986
Resolved 26 August 1986
Navigation
Issued 26 August 1986 Resolved
PRIOR TO ENTERING US WATERS AFTER 05SEP86, AFFIX THE STATEMENT REQUIRED BY 33CFR164.38(D)(1)(II) ON THE ARPA UNIT.
Condition: Unknown
Due 26 August 1986
Resolved 26 August 1986
Deck/Cargo
Issued 26 August 1986 Resolved
PRIOR TO CARRYING PRODUCTS AS DEFINED BY MARPOL 73/78, DEMONSTRATE THE PROPER OPERATION OF THE INERT GAS GENERATOR.
Condition: Unknown
Due 26 August 1986
Resolved 26 August 1986

Ownership record