Records from 1984 to 1993. Most recent: inspection, 30 June 1993.
Inspection history · 48
30 June 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846650
14 April 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146025
7 December 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140396
10 November 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 828287
17 June 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261420
1 June 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261354
20 May 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256970
20 May 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1258088
7 May 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 10983
26 March 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263828
25 March 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953514
5 February 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 947644
3 July 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249613
24 May 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942254
24 May 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246393
24 May 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253927
25 November 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1223724
28 September 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923683
16 August 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230206
16 July 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1225784
26 May 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931193
29 March 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 899508
2 February 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902285
26 January 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 978187
27 December 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923499
10 October 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340121
24 July 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204234
30 June 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331438
26 May 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201946
4 January 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1348864
19 December 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1032988
22 September 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195248
24 August 1988
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1346770
11 August 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1344763
5 July 1988
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342601
20 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016099
31 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309606
24 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031797
25 June 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008809
9 June 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340730
30 May 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000345
22 May 1987
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030201
3 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020510
16 June 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995219
18 December 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1293904
7 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977882
31 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 976200
15 November 1984
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 977523
Documentation
Issued 10 November 1992
Resolved
SUBMIT FOR REVIEW AND APPROVAL TO USCG MARINE SAFETY CENTER UPDATED VERSIONOF VESSEL'S OPERATING MANUAL. UPDATED MANUAL SHOULD INCLUDE REVISIONS NECESSARY AS RESULT OF INCLINING TEST CONDUCTED 6-10 NOV 92.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Construction/Loadline
Issued 10 November 1992
Resolved
SUBMIT PLANS AND WEIGHT DIFFERENCES FOR THE TOP DRIVE SYSTEM INSTALLATION, TO U.S. COAST GUARD (G-MSC) FOR APPROVAL AND CHANGES IN STABILITY INFORMATION. (31OCT92 PROMISED IN GMDC LTR, G.S. VIRK, OF 11JUN92.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Documentation
Issued 10 November 1992
Resolved
PROVIDE COPY OF FINAL REPORT OF INCLINING EXPERIMENT TO OFFICER IN CHARGE, MARINE INSPECTION NEW YORK, NY FOR INCLUSION INTO VESSEL'S PERMANENT FILES.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Documentation
Issued 10 November 1992
Resolved
POST COPY OF NEW VESSEL STABILITY LETTER AS REQUIRED BY 46 CFR 109.563(6). NEW STABILITY LETTER SHOULD BE BASED ON RESULTS/DATA OBTAINED AT INCLINING TEST CONDUCTED 6-10NOV92.
Condition: Unknown
Due 10 November 1992
Resolved 10 November 1992
Fire Fighting
Issued 20 May 1992
Resolved
REPLACE, HYDRO OR REPAIR PORTABLE FIRE EXTINGUISHERS AS PER SERVICE REPORT FROM THORN SECURITY DATED 13-16 MAY 92.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Construction/Loadline
Issued 20 May 1992
Resolved
REPAIR AS ORIGINAL THE DAMAGE IN PORT FORWARD COLUMN AT APPROX THE 75 FOOT LEVEL. REPAIR TO BE COMPLETED AT FIRST AVAILABLE TIME BUT NO LATER THAN NEXT DRY DOCK INSPECTION.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Fire Fighting
Issued 20 May 1992
Resolved
PROVIDE SIX (6) PORTABLE FOAM FIRE EXTINGUISHERS FOR THE ENGINE ROOM I.A.W.IMO 9.5.2.2.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Electrical
Issued 20 May 1992
Resolved
PERFORM TEST OF EMERGENCY BATTERIES AS REQUIRED BY 46 CFR 109.211
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Engineering
Issued 20 May 1992
Resolved
REPLACE OR HYDRO TEST BOTH OIL TRANSFER HOSES AS PER 33 CFR 155.800.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Fire Fighting
Issued 20 May 1992
Resolved
UPDATE FIRE CONTROL PLAN TO SHOW EXISTING CONDITION AND OBTAIN APROVAL FOR PLAN FROM [name withheld].
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
REPLACE THE FOLLOWING LIFE RINGS WITH APPROVED TYPE: STARBOARD SIDE - FORWARD, MIDSHIP, AND AFT, MOON POOL AREA - BOTH.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
REPLACE OR HYDRO TEST THE FOLLOWING AIR BOTTLES 54050N, 39276X, 97221Y, 30402X, 55995W, 33717.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Lifesaving
Issued 20 May 1992
Resolved
PROVIDE TEN (10) APPROVED PFD'S TO BRING TOTAL TO 125.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Fire Fighting
Issued 20 May 1992
Resolved
REPLACE FIRE EXTINGUISHER ON FORK LIFT WITH AN APPROVED TYPE.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Fire Fighting
Issued 20 May 1992
Resolved
REPLACE OR HYDRO THE FOLLOWING CO2 PORTABLE FIRE EXTINGUISHERS AT STATION_x001C_ NUMBER 26, 33, 35, 46, 47, 52, 61, 81, 83, 84, 85, 86, 88, 89, AND 91.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Accommodation/Occupational Safety
Issued 25 March 1992
Resolved
PROVIDE [name withheld] OF USCG APPROVAL OF DECK COVERING FOR ACCOMODATION SPACES OR REPLACE EXISTING MATERIAL WITH USCG APPROVED_x001C_ MATERIAL AND SUBMIT PROOF OF COMPLIANCE AND INSTALLATION.
Condition: Unknown
Due 25 March 1992
Resolved 25 March 1992
Accommodation/Occupational Safety
Issued 5 February 1992
Resolved
PROVIDE [name withheld], COPIES OF SPECIFICATIONS FOR ACCOMODATION DECK COVERING AND CREWS QUARTERS PANELING.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Unknown
Issued 5 February 1992
Resolved
SUBMIT PLANS AND WEIGHT DIFFERENCES FOR THE TOP DRIVE SYSTEM INSTALLATION, TO U.S. COAST GUARD (G-MSC) FOR APPROVAL AND CHANGES IN STABILITY INFORMATION.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Construction/Loadline
Issued 5 February 1992
Resolved
PROVIDE [name withheld], COPIES OF USCG APPROVED PLANS FOR THE CONVERSION OF #15P BALLAST TANK INTO EMERGENCY MUD DUMP TANK.
Condition: Unknown
Due 5 February 1992
Resolved 5 February 1992
Accommodation/Occupational Safety
Issued 24 May 1991
Resolved
MAKE ALL DRY BULK TANKS AVAILABLE FOR INTERNAL EXAMINATION BY A USCG MARINEINSPECTOR WITH EXCEPTION OF #17069 (FWD, STBD COLUMN) AND AB426 (CEMENT ROOM).
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Lifesaving
Issued 24 May 1991
Resolved
REPLACE THE TWO, NON-USCG APPROVED DAVIT-LAUNCHED INFLATABLE LIFERAFTS AT STATION #1 WITH TWO USCG APPROVED DAVIT-LAUNCHED RAFTS WHICH HAVE BEEN PROPERLY SERVICED WITHIN THE PAST 12 MONTHS. PROVIDE COPY OF SERVICING CERTIFICATE UPON INSTALLATION ON VESSEL TO [name withheld]._x001C_
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Accommodation/Occupational Safety
Issued 24 May 1991
Resolved
PROVE PROPER OPERATION OF RELIEF VALVES INSTALLED ON ALL (27) AIR RECEIVERSFOR VESSEL'S TENSIONING SYSTEM (#S 82-1101, 8211002, 821104, 821105, NY820621 THRU NY820633, NY820641 THRU NY820650). PROVIDE [name withheld] W/SAT TEST RESULTS FOR EACH VALVE, IN WRITING, BY A REPUTABLE SERVICE CO.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Fire Fighting
Issued 24 May 1991
Resolved
REPLACE DETERIORATING AFFF IN HELICOPTER DECK FIREFIGHTING FOAM SYSTEM. PROVIDE NEW FOAM SPECIFICATIONS AND CERTIFICATION BY OIM OF INSTALLATION INWRITING TO [name withheld]._x001C_ _x001C_
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Accommodation/Occupational Safety
Issued 24 May 1991
Resolved
REPAIR OR REPLACE THE PRESSURE RELIEF VALVES ON AIR RECEIVERS HOU 82705, HOU 82706, (LOCATED MAIN ENGINE ROOM) AND HOU 8270 (LOCATION PORT PONTOON),AND ENSURE PROPER OPERATION UPON INSTALLATION._x001C_ _x001C_
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Fire Fighting
Issued 24 May 1991
Resolved
REPAIR AND PROVE PROPER OPERATION OF ACCOMMODATION HOUSE FIRE DETECTION ANDALARM SYSTEM (PYROTRONICS SYSTEM 3)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Fire Fighting
Issued 26 May 1990
Resolved
HAVE ROAM ANALYSIS PERFOMED AND FORWARD COPY OF SATISFACTORY TEST REPORT TO [name withheld].
Condition: Unknown
Due 26 May 1990
Resolved 26 May 1990
Navigation
Issued 26 May 1990
Resolved
REPAIR OR REPLACE USCG APPROVED EPIRB ON FLYING BRIDGE.
Condition: Unknown
Due 26 May 1990
Resolved 26 May 1990
Fire Fighting
Issued 26 May 1990
Resolved
PROVIDE FIRE FIGHTING SERVICING REPORT TO [name withheld] WITH STATEMENT FROM OIM ATTESTING TO COMPLETION OF ALL PYRENE CO. SERVICEING DEFICIENCIES.
Condition: Unknown
Due 26 May 1990
Resolved 26 May 1990
Lifesaving
Issued 26 May 1990
Resolved
HAVE ANNUAL SERVICE IN A PERFORMED ON L/R'S #1 & 2 AT A USCG APPROVED FACILITY.
Condition: Unknown
Due 26 May 1990
Resolved 26 May 1990
Engineering
Issued 30 June 1989
Resolved
PROVIDE A REPORT OF TAILSHAFT WEAR DOWN READINGS AND A REPORT OF THE MOST RECENT STERN TUBE OIL ANALYSIS. THIS IS REQUIRED IN ORDER TO EVALUATE TAIL-SHAFT SURVEY CREDIT.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Construction/Loadline
Issued 30 June 1989
Resolved
PROVIDE COPY OF VIDEOTAPE (NORTH AMERICAN FORMAT) DEPICTING WELDMENTS ON PONTOONS AND OF SEACHESTS NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Unknown
Issued 30 June 1989
Resolved
CONDUCT HYDROSTATIC TEST OF CEMENT SURGE TANK TO 1 1/2 MAWP.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Construction/Loadline
Issued 30 June 1989
Resolved
CONDUCT EXTERNAL MPI TESTING OF CRITICAL JOINTS ON COLUMNS AND BRACING MEMBERS; OR OBTAIN APPROVAL FROM [name withheld] FOR THE NON-COAST GUARD WITNESSED MPI EXTERNAL TESTING CONDUCTED IN JAN/FEB 89
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Construction/Loadline
Issued 30 June 1989
Resolved
MAKE PERMANENT REPAIRS TO FRACTURES IN SIDE PLATING OF AFT PORT HORIZONTAL DIAGONAL BRACE IN WAY OF PORT COLUMN 2.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Electrical
Issued 26 May 1989
Resolved
REPAIR PURGE AIR ALARM IN DRILLER'S CONSOLE ON DRILL FLOOR IN ACCORDANCE WITH 46 CFR 111.105
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Deck/Cargo
Issued 26 May 1989
Resolved
HYDROSTATICALLY TEST OR INTERNALLY EXAMINE AIR RECEIVER, SERIAL #HOU82709 LOCATED BELOW DRILL FLOOR.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Engineering
Issued 26 May 1989
Resolved
HYDROSTATICALLY TEST OR INTERNALLY EXAMINE ALL MOTION COMPENSATION AIR RECEIVERS SERIAL #'S NY820623, NY820632, NY820624, NY820628, NY820643, NY820649, NY820642, NY820647, NY820650, NY820622, NY820629, NY820644, NY820648, NY820646, NY820631, NY820630, NY820626, NY820633, NY820621,
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Construction/Loadline
Issued 26 May 1989
Resolved
REPAIR OR REPLACE WEATHER TIGHT DOOR AT LOCATION 1.37 AND 1.74 DOOR WILL NOT CLOSE PROPERLY.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Fire Fighting
Issued 26 May 1989
Resolved
REMOVE ALL HIGH PRESSURE CYLINDERS, FIREFIGHTING AND SHIPS STORES THAT REQUIRE HYDROSTATIC TESTING.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Electrical
Issued 26 May 1989
Resolved
PROVIDE MECHANICAL GUARD FOR LIGHT, STB BULKHEAD IN SHALE SHAKER ROOM.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Electrical
Issued 26 May 1989
Resolved
PERMANENTLY AFFIX SENSOR JUNCTION BOX ON MEZZANINE DECK IN ACCORDANCE WITH 46 CFR 111.105
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Fire Fighting
Issued 5 July 1988
Resolved
REPLACE THE 2 DOORS, 1 PORT SIDE, 1 ON STBD SIDE, UPPER LEVEL, ACCOMODATIONS. BOTH DOORS OPEN TO WEATHER AND LOCATED AT ENDS OF MAIN PASSAGEWAY, BOTH DOORS BADLY DETERIOATED AND DO NOT OPERATE PROPERLY.
Condition: Unknown
Due 5 July 1988
Resolved 5 July 1988
Deck/Cargo
Issued 5 July 1988
Resolved
PROVIDE DOCUMENTATION FROM DNV OF ANNUAL CRANE TEST.
Condition: Unknown
Due 5 July 1988
Resolved 5 July 1988
Lifesaving
Issued 5 July 1988
Resolved
NOTIFY [name withheld] DAVIT LAUNCH LIFERAFT NO.2 HAS BEEN REPLACED OR SERVICED AT AN APPROVED SERVICING FACILITY.
Condition: Unknown
Due 5 July 1988
Resolved 5 July 1988
Construction/Loadline
Issued 5 July 1988
Resolved
REPLACE A-60 FIRE DOOR ON THE BRIDGE, PORT SIDE. PRESENT DOOR BADLY DETERIORATED AND LATCHING MECHANISM NOT WORKING PROPERLY.
Condition: Unknown
Due 5 July 1988
Resolved 5 July 1988
Engineering
Issued 9 June 1987
Resolved
PROVE BULK TANK, LLOYD'S #4007131 IN THE CEMENT ROOM IS BUILT TO ASME OR EQUIVALENT STANDARDS AS SET FORTH IN 46 CFR 54.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Fire Fighting
Issued 22 May 1987
Resolved
PROVIDE TO THE U.S. COAST GUARD A COPY OF THE ANNUAL FOAM ANALYSIS.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Fire Fighting
Issued 22 May 1987
Resolved
PROVE PROPER OPERATION OF ALL H2S SENSORS.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Documentation
Issued 22 May 1987
Resolved
OBTAIN A VALID FCC EXEMPTION CERTIFICATE.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Electrical
Issued 22 May 1987
Resolved
REMOVE ALL TEMP WIRING FROM ALL HAZARDOUS AREAS (CLASS I DIVISION 1 AND 2) PRIOR TO COMMENCING DRILLING OPERATIONS AND REMOVE ALL ADDITIONAL TEMP WIRING THROUGHOUT THE VESSEL BY 1 DECEMBER 1987.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Electrical
Issued 22 May 1987
Resolved
PROVIDE TO THE U.S. COAST GUARD FOR PLAN APPROVED DRAWINGS OF THE PURGE AIRSYSTEM FOR THE MUD PUMP ALARM PANEL LOCATED IN THE DRILLERS CONTROL ROOM.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Documentation
Issued 22 May 1987
Resolved
ACQUIRE AND MAINTAIN AN UP TO DATE CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Lifesaving
Issued 22 May 1987
Resolved
PROVIDE 12 U.S. COAST GUARD APPROVED HAND RED DISTRESS SIGNAL FOR EACH LIFEBOAT AND SMOKE SIGNED FOR EACH BOAT.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Electrical
Issued 22 May 1987
Resolved
PROVE THE CONTROL BOX PROVIDED BY BAUTEIL OFFSHORE LETTER IS SUITABLE FOR CLASS 1 DIVISION 11 LOCATIONS. THE CONTROL BOX IS MOUNTED NEXT TO THE DRILLERS CONSOLE.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Electrical
Issued 22 May 1987
Resolved
PROVE PROPER OPERATION OF THE AUDIBLE ALARM FOR THE LOSS OF PURGE AIR FOR THE SUB-SEA BOP CONTROL CONSOLE.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Fire Fighting
Issued 22 May 1987
Resolved
PROVE PROPER OPERATION OF MAIN DECK SPRINKLER ALARM FOR THE ACCOMMODATION SPACES.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Lifesaving
Issued 15 November 1984
Resolved
REPLACE WITH COAST GUARD APPROVED UNITS, OBTAIN COAST GUARD APPROVAL FOR THE EXPOSURE SUITS BY SEE OTTER THERMAL WEAR MFG. (MOD. NO. 41419 MK-II).
Condition: Unknown
Due 15 November 1984
Resolved 15 November 1984