MAURY USCG vessel records Sign in
← All vessels

DITTE THERESA

DITTE THERESA is a 1977 tank ship. The Coast Guard has recorded 43 inspections since 1984, most recently in August 2015, along with 108 deficiencies.

Records from 1984 to 2015. Most recent: inspection, 10 August 2015.

Built
1977
Last inspected
10 August 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7423732 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
244451
Flag
NETHERLANDS
367181000 (licence lapsed)
Maury page id
psix-244451

Inspections, by type

…with no type recorded18
Years with a record 15 calendar years (1984–2015)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2110 - Regulatory (Subpart C or D), Gross Ton
1592 - Regulatory (Subpart C or D), Net Ton
4501 - Dead Weight, Ton
1631 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KNFHMMSI 367181000 · expired · compulsorily equipped · granted 17 May 1996, cancelled 22 July 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JANG WON NO. 2 Towing Vessel · MISLE 386959 · 2 March 1993 · activity 97830

Inspection history · 43

10 August 2015 Deficiency Check
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5211964
5 August 2003 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1867146
23 October 1996 Administrative
Administrative · Activities Europe · Activity 1159871
4 March 1996 COI Inspection
Physical examination · Activities Europe · Activity 1189453
1 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373888
15 December 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 838677
5 September 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846734
20 April 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 44401
13 April 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856781
8 December 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1159631
24 November 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 118560
30 October 1993 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1152692
17 March 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 840075
4 March 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 647176
2 March 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 97830
8 February 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 826500
4 February 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1133477
1 February 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1141180
7 December 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 825780
21 October 1991 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1257396
18 October 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 962036
4 February 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1300045
29 December 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229819
20 December 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910614
10 September 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 915425
21 August 1990 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 925287
16 April 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 899577
29 March 1990 Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 914477
17 January 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1232103
13 October 1989 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1239593
17 November 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1342188
12 April 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1345350
14 February 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1030155
13 February 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 503693
16 July 1987 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1333438
16 July 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1333440
3 March 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1319289
4 December 1986 Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1332426
26 September 1986 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1312406
20 January 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 997842
21 February 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978523
3 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 520906
13 December 1984 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 979045

Deficiency record · 108

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (100 ppm)
Issued 11 August 2003 Resolved
Oily water separator alarm is not working.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 11 September 2003
Resolved 10 August 2015
Resolution: Administratively cleared deficiency prior to MISLE 5.0 migration. Vessel no longer calls on the US.
Documentation › Safety/Response Plans/Programs › General Arrangement Plans
Issued 5 August 2003 Resolved
No Vessel Response Plan onboard. LEGACY COMPONENT DESC: Vessel Response Plan
Action required: 15 - Rectify deficiencies by next port
Due 11 September 2003
Resolved 10 August 2015
Resolution: Administratively cleared deficiency prior to MISLE 5.0 migration. Vessel no longer calls on the US.
Construction/Loadline
Issued 4 March 1996 Resolved
At the vessel's next DDX repair damage to three frames in #2 starboard double bottom.
Condition: Unknown
Due 31 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 4 March 1996 Resolved
The following certificates must be obtained from the ABS before departing Pireaus, Greece: Safety Construction Certificate; Load Line; Safety Radiotelegraphy Certificate; and Safety Radiotelephone Certificate.
Condition: Unknown
Due 11 March 1996
Resolved 17 June 1996
Lifesaving
Issued 4 March 1996 Resolved
Install vessel's EPIRB after its return from service facility. Vessel is not to sail from Pireaus, Greece, until confirmation has been faxed to MIO Europe.
Condition: Unknown
Due 11 March 1996
Resolved 17 June 1996
Fire Fighting
Issued 4 March 1996 Resolved
Clearly label all ventilation closures for the engineroom and the pump roomthat are to be closed when the fixed CO2 system is discharged. Instructions shall be posted at the remote station and CO2 room detailing the location of these vent closures.
Condition: Unknown
Due 18 July 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 4 March 1996 Resolved
At vessel's next drydocking (DDX) all CO2 bottles and the flexible loops shall be tested hydrostatically at a U.S. DOT approved facility. These CO2bottles/hoses are in the fixed system for the engine room, pump room and paint locker.
Condition: Unknown
Due 31 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 4 March 1996 Resolved
At the vessel's next DDX hydrostatically test all cargo piping on the main deck and shelter deck.
Condition: Unknown
Due 31 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 4 March 1996 Resolved
Replace all Pains-Wessex SOLAS hand flares, parachute flares and smokes which do not show USCG approval. Alternatively, provide documentation frommanufacturer that pyrotechnics presently on board meet USCG requirements.
Condition: Unknown
Due 7 March 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 4 March 1996 Resolved
Replace Unitor non-USCG portable fire extinguishers (7 total) that were purchased to replace condemned extinguishers. Replace non-USCG life boat fire extinguishers (4 total). Replacement extinguishers shall be USCG approved. This shall be done by vessel's DDX.
Condition: Unknown
Due 31 October 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 5 September 1994 Resolved
SUBMIT ABS REPORTS TO [name withheld] OF SATISFACTORY TESTING DURING SEPTEMBER 1994 DRYDOCKING OF RENEWAL OF BOTTOM PLATING BETWEEN FRAMES 28 TO32.
Condition: Unknown
Due 5 September 1994
Resolved 5 September 1994
Engineering
Issued 8 December 1993 Resolved
EFFECT REPAIRS TO REDUCTION GEAR AND ASSOCIATED PROPULSION SYSTEM. UPON COMPLETION OF REPAIRS, DEMONSTRATE MAIN ENGINE AND PROPULSION PORTIONS OF AUTOMATION PROCEDURES.
Condition: Unknown
Due 25 December 1993
Resolved 28 December 1993
Construction/Loadline
Issued 30 October 1993 Resolved
REPAIR OR REPLACE OILY WATER SEPERATOR MONITOR. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZENT [name withheld] SHALL BE RETAINED ON BOARD AND DISCHARGED TO A SHORESIDE RECEPTION FACILITY UNTIL REPAIRS COMPLETED.
Condition: Unknown
Due 30 October 1993
Resolved 30 October 1993
Construction/Loadline
Issued 30 October 1993 Resolved
CROP AND RENEW STANCHION AND DEEP STRINGERS (3) IN WAY OF INSET DAMAGE, FORECASTLE, PORT SIDE.
Condition: Unknown
Due 30 October 1993
Resolved 30 October 1993
Engineering
Issued 7 December 1992 Resolved
DEMONSTRATE THE PROPER OPERATION OF THE MAIN ENGINE OVERSPEED ALARM ON THE MAIN ALARM BOARD.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Electrical
Issued 7 December 1992 Resolved
PROPERLY DEADEND WIRING IN DECK GEAR LOCKER.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Electrical
Issued 7 December 1992 Resolved
PROVIDE PROPER STORAGE BOXES FOR BATTERIES FOR THE AUXILIARY GENERATORS ANDALARM PANEL LOCATED IN THE ENGINEROOM.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Engineering
Issued 7 December 1992 Resolved
PROVE THE PROPER OPERATION OF THE OILY WATER SEPARATOR MONITORING SYSTEM.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Electrical
Issued 7 December 1992 Resolved
REMOVE OR MAKE OPERATIONAL THE ELECTRIC MOTORS LOCATED FORWARD OF THE ENGINEROOM ON THE 2ND PLATFORM.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Lifesaving
Issued 7 December 1992 Resolved
RENEW TILLER ARM TO PORT LIFEBOAT.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Engineering
Issued 7 December 1992 Resolved
RENEW OR CLEAN AS NECESSARY, ALL FLAME SCREENS TO INCLUDE P/V VALVES AND ULLAGE OPENINGS.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Lifesaving
Issued 7 December 1992 Resolved
PROVIDE MUFFLERS FOR PNEUMATIC LIFE BOAT WINCHES.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Deck/Cargo
Issued 7 December 1992 Resolved
REMOVE OR MAKE OPERATIONAL HEAVY OIL SYSTEM AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Accommodation/Occupational Safety
Issued 7 December 1992 Resolved
DEMONSTRATE THE PROPER OPERATION OF ONBOARD EVAPORATOR AND ASSOCIATED EQUIPMENT.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Lifesaving
Issued 7 December 1992 Resolved
PROVE PROPER OPERATION OF THE ENGINEER NEED ASSISTANCE ALARM ON THE BRIGDE.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Electrical
Issued 7 December 1992 Resolved
PROVE THE PROPER OPERATION OF THE NO.1 AUXILIARY GENERATOR SPEED SENSOR.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Fire Fighting
Issued 7 December 1992 Resolved
PROVIDE HAMMERS FOR CO2 BREAK BOXES AFT OF C02 ROOM.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Engineering
Issued 4 February 1991 Resolved
PROVIDE EXPLANATION OF WORK REQUIRED WHICH IS NOT REIMBURSED FOR (ie: DOCKING/ UNDOCKING, ETC)
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991 Resolved
MAKE LOW OIL LEVEL, DECK HYDRAULIC RESERVIOR TANK ALARM/SYSTEM OPERATE AS PER C.G. APPROVED PROCEDURE.
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991 Resolved
MASTER OF VESSEL WILL PROVIDE PHOTOCOPIES OF ALL OVERTIME VOUCHERS/FORMS UTILIZED TO PAY ALL CREW MEMBERS FROM NOVEMBER 1, 1989 TO PRESENT.
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991 Resolved
PROVIDE EXPLANATION OF CREW CONTRACTS IF OVERTIME IS NOT PAID, FOR MORE THAN 8 HOURS WORK OR TIME OVER 8 HOURS IS NOT CONSIDERED OVERTIME.
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Engineering
Issued 4 February 1991 Resolved
MAKE STANDBY JACKET WATER PUMP START AUTOMATICALLY AS PER C.G. APPROVED AUTOMATION PROCEDURE-CHAPTER 2 (B).
Condition: Unknown
Due 4 February 1991
Resolved 4 February 1991
Fire Fighting
Issued 29 December 1990 Resolved
CLARIFY OPERATING INSTRUCTIONS FOR EMERGENCY DIESEL FIRE PUMP (IE: VALVE- IDENTITY AND LOCATION ).
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Electrical
Issued 29 December 1990 Resolved
PROVIDE COVERS FOR EMERGENCY LIGHTING UNITS (DEFUSERS/LENSES) OR RENEW WITHC.G. ACCEPTABLE UNITS.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Lifesaving
Issued 29 December 1990 Resolved
PROVIDE C.G. ACCEPTABLE WATER FOR THOSE CANS FOUND UNSATISFACTORY.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Documentation
Issued 29 December 1990 Resolved
PROVIDE PHOTOCOPIES OF ABS ANNUAL ENDORSEMENTS FOR LOADLINE CERTIFICATE, SAFETY CONSTRUCTION CERTIFICATE AND SUPPLEMENT.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Deck/Cargo
Issued 29 December 1990 Resolved
ALL CARGO PIPING TO BE HYDROSTATICALLY TESTED PRIOR TO DEPARTURE NEXT SHIPYARD AVAILABILITY OR COI.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Navigation
Issued 29 December 1990 Resolved
PROVIDE REPLACEMENT AND SPARE BULBS FOR STEERING GEAR ALARM PANEL IN ENGINEROOM.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Navigation
Issued 29 December 1990 Resolved
PROVIDE COPY OF CURRENT COMPASS DEVIATION TABLE.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Engineering
Issued 29 December 1990 Resolved
ENSURE CLOSURE OF ALL FUEL OIL / PETROLEUM PRODUCT VENT SCREENS.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Lifesaving
Issued 29 December 1990 Resolved
RENEW PORT MOTOR LIFEBOAT PROPELLOR.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Lifesaving
Issued 29 December 1990 Resolved
VESSEL WILL HAVE SERVICED BY AN APPROVED (C.G.) FACILITY BOTH HYDROSTATIC LIFE RAFT RELEASES OR REPLACE WITH SAME HAVING CURRENT INSPECTION PRIOR TO DEPARTURE HACHINOHE, JAPAN ON OR ABOUT 6 DEC 90.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Lifesaving
Issued 29 December 1990 Resolved
VESSEL WILL HAVE SERVICED BY AN APPROVED (C.G.) FACILITY BOTH OUT OF DATE LIFE RAFTS OR REPLACE WITH SAME HAVING CURRENT INSPECTION PRIOR TO VESSEL DEPARTURE HACHINOHE, JAPAN ON OR ABOUT 6 DEC 90.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Navigation
Issued 29 December 1990 Resolved
VESSEL WILL RENEW EPIRB BATTERY WITH ONE NOT HAVING EXPIRED PRIOR TO DEPARTURE HACHINOHE, JAPAN ON OR ABOUT 6 DEC 90.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Engineering
Issued 29 December 1990 Resolved
VESSEL WILL SHOW AS MANUFACTURED AND C.G. APPROVED OPERATION OF VESSELS OILY WATER SEPERATOR. UNTIL REPAIRED ALL BILGE SLOPS TO BE STORED IN SLOP TANK AND DISCHARGE TO ACCEPTABLE SHORE FACILITY.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Fire Fighting
Issued 29 December 1990 Resolved
HYDRO OR RENEW COMPRESSED OXYGEN BOTTLES (4 EA) AND RECHARGE.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Fire Fighting
Issued 29 December 1990 Resolved
PROVIDE SPAN GAS AND SAMPLING HOSE AND VERIFY PROPER OPERATION OF OXYGEN METER.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Fire Fighting
Issued 29 December 1990 Resolved
PROVIDE AND MOUNT FAN BELT GUARD ON FRONT OF EMERGENCY FIRE PUMP DIESEL DRIVE.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Accommodation/Occupational Safety
Issued 29 December 1990 Resolved
REMOVE SOFT PATCH AND REPAIR DRAIN LINE LOCATED BEHIND ENGINE ROOM ALARM PANEL.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Deck/Cargo
Issued 29 December 1990 Resolved
PROVIDE AND MOUNT GUARD ON FRONT OF CATIPILLAR HYDRUALIC DRIVE DIESEL.
Condition: Unknown
Due 29 December 1990
Resolved 29 December 1990
Navigation
Issued 16 April 1990 Resolved
PRIOR TO CARRIAGE OF CARGO, CONDUCT SEA TRIALS FOR THE PURPOSE OF TESTING STEERING GEAR AND CONTROLABLE PITCH PROPELLER. TESTS ARE TO WITNESSED BY CG MARINE INSPECTOR.
Condition: Unknown
Due 16 April 1990
Resolved 16 April 1990
Construction/Loadline
Issued 13 October 1989 Resolved
REMOVE OXYGEN ACETYLENE PIPING SYSTEM. STOW BOTTLES NOT IN ACTUAL USE IN SEPARATE AREAS. THIS SYSTEM SHALL NOT BE USED FROM THIS DAY FORTH UNLESS SAME IS APPROVED BY THE MARINE SAFETY CENTER, COAST GUARD HEADQUARTERS, WASHINGTON, D.C.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 13 October 1989 Resolved
SUBMIT FOR APPROVAL TO THE [name withheld], VESSEL'S GENERAL (EMERGENCY CON- TROL) ARRANGEMENT PLANS. DETAILS OF SAME SHALL BE IN ACCORDANCE WITH 46 CFR 35.10-3 AND AS IS ARRANGEMENT OF VESSEL REFLECTING ALL PAST AND PRESENT MODIFICATIONS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 13 October 1989 Resolved
PROVIDE A COPY TO THE [name withheld], RESULTS OF FOAM SAMPLE TAKEN OCT 89. SHOULD REPORT SHOW THAT SAME IS NOT ACCEPTABLE VESSEL'S FOAM TANK SHALL BE DRAINED AND SAME FILLED WITH FRESH FOAM OF THE PROPER TYPE AND TO TANK'S CAPACITY.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 13 October 1989 Resolved
PROVIDE TWO ADDITIONAL FIREMAN'S OUTFITS INCLUDING THEIR REQUIRED EQUIPMENT AS PER SOLAS CHAPTER II-2 REGULATIONS 17.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Documentation
Issued 13 October 1989 Resolved
PROVIDE ON BOARD A COMPLETE SET OF THE MOST CURRENT PUBLICATION OF BOTH 46 CFR'S AND SOLAS REGULATIONS.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Fire Fighting
Issued 13 October 1989 Resolved
REPAIR THE FOLLOWING REMOTE OPERABLE VALVES: (A) OPEN AND CLOSE VALVES FOR BOTH GENERAL SERVICE PUMPS LOCATED IN THE ENGINE ROOM. (B) CROSS OVER VALVE IN THE ENGINE ROOM. (C) FIRE PUMP SUCTION VALVE.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Construction/Loadline
Issued 13 October 1989 Resolved
REPAIR MACHINERY SPACE'S VERTICAL BILGE PUMP.
Condition: Unknown
Due 13 October 1989
Resolved 13 October 1989
Deck/Cargo
Issued 17 November 1988 Resolved
MAKE OPERABLE CARGO PUMP DIESEL ENGINE EMERGENCY SHUT-DOWN SWITCHES AT HOUSE FRONT AND ENGINE ROOM LOCATIONS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Construction/Loadline
Issued 17 November 1988 Resolved
MAKE PERMANENT REPAIR TO PATCHED NUMBER 3 DOUBLE BOTTOM PORT SIDE TANK VENTDECK PENETRATION.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988 Resolved
MAKE PERMANENT REPAIR TO PATCHED PIPE JOINTS AT MAIN DIESEL ENGINE FRESH WATER HEAT EXCHANGER.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY OPERATION OF THROTTLE WRONG DIRECTIONALARM FUNCTION.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY OPERATION OF CARGO PUMP DIESEL ENGINEOVERSPEED TRIP AND HIGH COOLANT TEMP ALARM.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988 Resolved
PROVIDE EMERGENCY LIGHT FOR STAIRWAY CONNECTING OFFICER DECK TO CREW DECK.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988 Resolved
LABEL SHELTER DECK EMERGENCY LIGHTING WITH "E" SYMBOL.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
PROVIDE "GO TO YOUR STATION" STENCIL/PLACARD IN VICINITY OF FWD HOUSE GENERAL ALARM BELL.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Electrical
Issued 17 November 1988 Resolved
REPLACE BURNED OUT EMERGENCY LIGHT IN AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 17 November 1988 Resolved
SECURE LOOSE THERMAL FIRE SENSOR LOCATED ABOVE HEAVY OIL SEPARATOR.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
PROVE SATISFACTORY OPERATION OF MACHINERY SPACE BILGE OIL/WATER SEPARATOR UNIT AND ASSOCIATED 15 PPM ALARM. PENDING CONFIRMATION OF OPERATION, BILGEOVERBOARD DISCHARGE VALVE SHALL BE POSITIVELY RESTRAINED IN CLOSED POSITIONAND ALL WASTES STORES IN SLOP TANK FOR DELIVERY TO SHORESIDE FACILITY.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Engineering
Issued 17 November 1988 Resolved
REVISE WRITTEN MACHINERY AUTOMATION TEST PROCEDURES FOR MAIN DIESEL ENGINE,SHIP SERVICE GENERATORS, AUXILIARY EQUIPMENT, AND THROTTLE CONTROL SYSTEM, AND SUBMIT SAME TO [name withheld].
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
REPAIR OR REPLACE DETERIORATED SECTIONS OF PORT AND STARBOARD DRIP PANS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 17 November 1988 Resolved
PROVIDE SATISFACTORY FOAM ANALYSIS REPORT FOR FIXED FOAM SYSTEM.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Lifesaving
Issued 17 November 1988 Resolved
PROVIDE FRAME FOR BOAT COVER, AS REQUIRED BY SOLAS CONVENTION, FOR THE NUMBER 2 LIFEBOAT.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Lifesaving
Issued 17 November 1988 Resolved
REPAIR DAMAGED TILLER FOR THE NUMBER 2 LIFEBOAT.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY ANNUAL HYDROSTATIC TEST OF DECK CARGO PIPING.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 17 November 1988 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY HYDROSTATIC TESTING OF ALL PORTABLE CO2 CYLINDERS WITH LAST HYDRO DATE OF NOV 1983 OR BEFORE (TOTAL 7 UNITS).
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
MAKE PERMANENT REPAIR TO LEAKY SECTIONS OF PORT AND STBD CARGO BOOM WINCH METAL AND FLEXIBLE HYDRAULIC LINES.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
MAKE NUMBER 2C CARGO TANK AVAILABLE FOR USCG INTERNAL EXAMINATION.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
MAKE PERMANENT REPAIR TO DETERIORATED SECTIONS OF PORT AND STBD CARGO MANIFOLD DRIP PANS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Deck/Cargo
Issued 17 November 1988 Resolved
REPAIR HOLED SECTION OF NUMBER 2P CARGO TANK VENT LINE PRIOR TO NEXT CARGO LOADING.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Unknown
Issued 17 November 1988 Resolved
POSITIVELY RESTRAIN IN CLOSED POSITION THE MSD TANK OVERBOARD DISCHARGE VALVE WHEN OPERATING IN U.S. NAVIGABLE/TERRITORIAL WATERS.
Condition: Unknown
Due 17 November 1988
Resolved 17 November 1988
Fire Fighting
Issued 14 February 1988 Resolved
DRAIN AND CLEAN SHIP'S FIXED FOAM TANK.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Navigation
Issued 14 February 1988 Resolved
DEMONSTRATE PROPER OPERATION OF STEERING PUMP INDICATOR LIGHTS IN THE AFTERSTEERING STATION.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Engineering
Issued 14 February 1988 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH AIR RECEIVER RELIEF VALVES IN THE MACHINERY SPACES.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Engineering
Issued 14 February 1988 Resolved
DEMONSTRATE PROPER OPERATION OF OIL AND WATER SEPARATOR.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Electrical
Issued 14 February 1988 Resolved
DEMONSTRATE PROPER OPERATION OF NO. 2 SHIP SERVICE GENERATOR'S OVERSPEED TRIP.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Electrical
Issued 14 February 1988 Resolved
DEMONSTRATE PROPER OPERATION OF NO. 1 AND NO. 2 SHIPS SERVICE GENERATOR HIGH TEMPERATURE SHUTDOWN.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Fire Fighting
Issued 14 February 1988 Resolved
PROVE PROPER OPERATION OF FIRE PUMP AND VALVES FROM BRIDGE REMOTE STATION. ENGINE ROOM SHALL BE MANNED UNTIL FIRE PUMP IS FULLY OPERATIONAL FROM BRIDGE.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Electrical
Issued 14 February 1988 Resolved
INCREASE WATTAGE TO THE EMERGENCY LIGHTING IN THE AFTER STEERING STATION.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Lifesaving
Issued 14 February 1988 Resolved
BOTH LIFERAFTS ONBOARD MUST BE SERVICED BY A U.S.C.G. APPROVED LIFERAFT SERVICING FACILITY.
Condition: Unknown
Due 14 February 1988
Resolved 14 February 1988
Construction/Loadline
Issued 4 December 1986 Resolved
DEMONSTRATE OPERATION OF THE MARPOL REQUIRED OIL CONTENT DISCHARGE MONITOR.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Lifesaving
Issued 4 December 1986 Resolved
CONDUCT LIFEBOAT DRILL - MAN, LOWER, RELEASE, AND OPERATE LIFEBOATS IN THE WATER IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Lifesaving
Issued 20 January 1986 Resolved
STENCIL VESSEL'S NAME ON ALL SURVIVAL SUITS AND PROVIDE SAME WITH LIGHTS.
Condition: Unknown
Due 20 January 1986
Resolved 20 January 1986
Lifesaving
Issued 20 January 1986 Resolved
PROVIDE PROOF THAT THE LIFERAFT SERVICING FACILITY IS COAST GUARD APPROVECD OR RESERVICE BOTH LIFERAFTS AT AN APPROVED FACILITY.
Condition: Unknown
Due 20 January 1986
Resolved 20 January 1986
Unknown
Issued 20 January 1986 Resolved
PROVIDE PROOF OF COAST GUARD ACCEPTABILITY OF THE TYPE III MSD.
Condition: Unknown
Due 20 January 1986
Resolved 20 January 1986
Navigation
Issued 13 December 1984 Resolved
PROVIDE AUDIBLE ALARM FOR NAVIGATION LIGHT PANEL.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Unknown
Issued 13 December 1984 Resolved
THE TWO AIR RECEIVER RELIEF VALVES ARE TO BE REPLACED WITH RELIEF VALVES ASREQUIRED BY 46 CFR 54.15-10.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Engineering
Issued 13 December 1984 Resolved
PROVIDE EMERGENCY STOP FOR MAIN ENGINE AT ENGINE ROOM CONSOLE.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Electrical
Issued 13 December 1984 Resolved
FUSE HOLDERS IN ELECTRICAL SUB-DISTRIBUTION PANELS. T-1,T-2,T-4,T-5,L-1, N-1,N-2 AND ALL MOTOR CONTROLLERS ARE REQUIRED TO BE RESILENTLY MOUNTED.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Lifesaving
Issued 13 December 1984 Resolved
INSTALL AIR MOTORS ON LIFEBOAT DAVIT WINCHES. MOTORS WERE NOT AVAILABLE MANUFACTURER. DAVIT WINCHES OPERABLE BY HAND CRANK.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Engineering
Issued 13 December 1984 Resolved
PROVIDE EOT AT LOCAL ENGINE STATION. UPON COMPLETION, REMOVE THE EXISTING FOREIGN EOT SYSTEM.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Fire Fighting
Issued 13 December 1984 Resolved
FORWARD FIRE PUMP REPLACEMENT: FWD FIRE PUMP DOES NOT PRODUCE THE REQUIREDPRESSURE. VESSEL HAS TWO FIRE PUMPS IN ENGINE ROOM. THIS ITEM IS UNDER APPEAL, BUT MUST BE COMPLETED WITHIN THIRTY DAYS AFTER THE FINAL DECISION ON APPEAL UNLESS APPEAL IS UPHELD.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Engineering
Issued 13 December 1984 Resolved
THE PROPELLER PITCH INDICATOR AT ENGINE ROOM CONSOLE DOES NOT INDICATE PROPERLY. UNTIL REPAIRS ARE MADE, PROVIDE REFERENCE MARKS FOR PITCH ON INPUT GAUGE.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Engineering
Issued 13 December 1984 Resolved
CALIBRATE OR REPAIR MAIN ENGINE RPM GAUGE AT ENGINE ROOM CONSOLE.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Unknown
Issued 13 December 1984 Resolved
QUICK CLOSING VALVES REQUIRED ON DOUBLE BOTTOM TANK SOUNDING TUBES IN WAY OF PORT GENERATOR AND STBD BILGE MANIFOLD.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Deck/Cargo
Issued 13 December 1984 Resolved
NO. 2 AND 4 CENTER CARGO TANK CLOSED GAUGING SYSTEM NOT WORKING PROPERLY. REPAIR PRIOR TO CARGO OPERATION IN TANKS 2 AND 4 CENTER.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Unknown
Issued 13 December 1984 Resolved
RELOCATE LADDERS FROM POOP DECK TO SHELTER DECK. PRESENT LADDERS ARE TO CLOSE TO STANCHIONS.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984
Electrical
Issued 13 December 1984 Resolved
PROVIDE ADDITIONAL LIGHTING FOR CARGO DECK AREA.
Condition: Unknown
Due 13 December 1984
Resolved 13 December 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.