MAURY USCG vessel records Sign in
← All vessels

RBF 254

RBF 254 is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 31 inspections since 1984, most recently in August 2001, along with 110 deficiencies.

Records from 1984 to 2001. Most recent: inspection, 8 August 2001.

Built
1976
Last inspected
8 August 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

HP-8129
244586
Flag
LIBERIA
—
Maury page id
psix-244586

Inspections, by type

…with no type recorded13
Years with a record 12 calendar years (1984–2001)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2705 - Regulatory (Subpart C or D), Gross Ton
1893 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

8 August 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069405
6 July 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067595
25 May 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1373525
25 May 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819234
10 December 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395284
15 October 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434794
7 August 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130946
3 August 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1130909
8 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1125650
28 January 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 781996
2 October 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396806
4 October 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1374776
30 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 87877
9 April 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1079732
1 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764725
7 February 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 202104
2 November 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1443632
10 October 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1371193
27 January 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 115540
3 October 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1447389
18 May 1994 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1169487
8 April 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 693360
14 March 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 140172
3 March 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 30942
9 December 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 23293
22 September 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1409017
23 June 1987 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1006354
15 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290479
20 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 983814
19 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1293746
4 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977141

Deficiency record · 110

Engineering
Issued 25 May 2001 Resolved
Prove proper operation of all safety devices on all generators. (1-4).
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 25 May 2001 Resolved
Remount light on helo deck.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 25 May 2001 Resolved
Prove proper operation of safety devices on number one and number two main generators.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 25 May 2001 Resolved
Prove proper operation of emergency generator and associated safety devices.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 25 May 2001 Resolved
Repair self closing doors to mud pits.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Accommodation/Occupational Safety
Issued 25 May 2001 Resolved
Make readable relief valve tags on cement tanks.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 25 May 2001 Resolved
Prove operation of number two bilge pump.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Fire Fighting
Issued 25 May 2001 Resolved
Prove proper operation of fire pump relief valve.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 25 May 2001 Resolved
Install emergency lighting fixture in way of workshop.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 25 May 2001 Resolved
Provide drip pan for filter assembly on emergency generator.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 25 May 2001 Resolved
Demonstrate proper seal on main deck hatches and repair coaming as needed.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 25 May 2001 Resolved
Install wire supports for pumproom cable.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 25 May 2001 Resolved
Install wire supports for helo deck perimeter lighting.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Fire Fighting
Issued 25 May 2001 Resolved
Renew deepwell six inch suction line valve on next rig move.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 25 May 2001 Resolved
Repair fuel oil leaks on diesel tank piping by emergency generator house.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Unknown
Issued 25 May 2001 Resolved
Remove holdback device for fuel nozzle by emergency generator house.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 25 May 2001 Resolved
Repair all fuel oil leaks on purifier piping. (centrifuge).
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 25 May 2001 Resolved
Replace gaskets for engineroom exhaust and pit room exhaust.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Fire Fighting
Issued 25 May 2001 Resolved
Provide servicing report for Fire Station Six extinguisher and BV extinguisher on helo deck.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Electrical
Issued 25 May 2001 Resolved
Perform load test on emergency batteries per 46CFR109.211
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 25 May 2001 Resolved
Rplace emergency shutdown pneumatic hose for emergency generator.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 25 May 2001 Resolved
Demonstrate proper seal on pumproom doors and all watertight doors on main deck.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Lifesaving
Issued 25 May 2000 Resolved
FINISH THE CROPPING AND RENEWING OF ALL WASTED/DAMAGED HANDRAILS, WALKWAYS,AND DECK GRATING AS NOTED DURING INSPECTION.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Construction/Loadline
Issued 25 May 2000 Resolved
COMPLETE REPAIRS/REPLACEMENT OF ALL WASTED, WORN, AND INOPERATIVE WATERTIGHT/WEATHERTIGHT DOORS THROUGHOUT RIG AS NOTED DURNING INSPECTION.
Condition: Unknown
Due 25 May 2000
Resolved 25 May 2000
Unknown
Issued 10 December 1999 Resolved
REPAIR OBSTRUCTION LIGHT ON THE AFT PORT CORNER OF THE RIG.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Lifesaving
Issued 10 December 1999 Resolved
CONDUCT AND PROPERLY LOG ALL REQUIRED TRAINING, INSPECTIONS AND TESTS OF LIFEBOATS AS PER 46 CFR 109.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Fire Fighting
Issued 10 December 1999 Resolved
ADD DIRECTIONS TO PAINT LOCKER FOR SECURING ELECTRICAL POWER.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Lifesaving
Issued 10 December 1999 Resolved
REPLACE AND/OR SERVICE ALL RING BUOYS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
CONDUCT AND PROPERLY LOG EMERGENCY GENERATOR AND EMERGENCY BATTERY TESTS ASPER 46 CFR 109.211.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
CONDUCT AND PROPERLY LOG LINE THROWING GUN TRAINING AND INSPECTION.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Fire Fighting
Issued 10 December 1999 Resolved
COMPLETE ALL DEFICIENCIES NOTED ON TOTAL SAFETY'S FIREFIGHING INSPECTION REPORT COMPLETED ON 13 OCT 99. CONDUCT MINIMUM 100 PSI PRESSURE TEST OF ALLFIRE HOSES.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
CROP AND RENEW DAMAGED SECTIONS OF HELO DECK SAFETY FENCE AND DECK.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Engineering
Issued 10 December 1999 Resolved
CONDUCT AND PROPERLY LOG ANNUAL FUEL HOSE INSPECTION AS PER 33 CFR 155.800.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
REPAIR/REPLACE ALL WASTED/WORN/INOPERATIVE WATERTIGHT/WEATHERTIGHT DOORS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Fire Fighting
Issued 10 December 1999 Resolved
CROP AND RENEW ALL WASTED FIRE HOSE RACKS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Unknown
Issued 10 December 1999 Resolved
CORRECT ALL DEFICIENCES NOTED TO THE SATISFACTION OF CLASS SOCIETY AND THE LOCAL [name withheld] BY MARINE INSPECTORS.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Lifesaving
Issued 10 December 1999 Resolved
PROVIDE DOCUMENTATION TO [name withheld] LAST WIRE FALL REPLACEMENT OF LIFEBOAT AND LIFERAFTS. IN ADDITION, LOAD TEST OF LIFEBOAT AND LIFERAFT DAVITS CONDUCTED AFTER FALL REPLACEMENT.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Lifesaving
Issued 10 December 1999 Resolved
CORRECT THE FOLLOWING DEFICIENCIES FOR LIFEBOAT #1: 1. REPLACE ALL BATTERIES. 2. REPLACE STORM OIL CAN. 3. PROVIDE STORM OIL. 4. CREATE EQUIPMENT LIST. 5. PROPERLY INSTALL RETRO TAPE. 6. REPLACE ENGINE THROTTLE CONTROL. 7. REPLACE BAD DAVIT BUMPER. 8. REPAIR/LABEL ALL "E" LIGHTS.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Electrical
Issued 10 December 1999 Resolved
REWORK AND PROPERLY SECURE EXCESSIVE WIRING ON THE DRILL FLOOR, SHAKER AREAAND MUD PITS.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Lifesaving
Issued 10 December 1999 Resolved
PRIOR TO COMMENCING DRILLING OPERATIONS, AND IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR, CONDUCT SATISFACTORY FIRE AND BOAT DRILL.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Electrical
Issued 10 December 1999 Resolved
PROPERLY INDEX DISTRIBUTION PANELS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
CROP AND RENEW ALL WASTED/DAMAGED HANDRAILS, WALKWAYS, AND DECK GRATING THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Lifesaving
Issued 10 December 1999 Resolved
MAKE REPAIRS TO AND CONDUCT 1.1 WEIGHT TEST TO LIFEBOAT DAVIT ASSEMBLY PRIOR TO MANNING RIG. PROVIDE COPY OF WEIGHT TEST CERTIFICATE TO THE [name withheld].
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Unknown
Issued 10 December 1999 Resolved
MAKE REPAIRS TO STARBOARD CRANE. CONDUCT ABS ANNUAL CRANE INSPECTION TO BOTH CRANES. SUBMIT COPY OF ABS CRANE INSPECTION REPORTS TO THE [name withheld].
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Fire Fighting
Issued 10 December 1999 Resolved
MAKE ALL DOORS IN "A" CLASS BULKHEADS SELF CLOSING AND LATCHING "A" CLASS DOORS.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Engineering
Issued 10 December 1999 Resolved
REPLACE FUEL LINE ON #2 MAIN GENERATOR.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Fire Fighting
Issued 10 December 1999 Resolved
MAKE ALL DOORS TO / FROM SCR ROOM "A" CLASS, SELF-CLOSING.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Electrical
Issued 10 December 1999 Resolved
TEST PURGE AIR ALARMS AT DRILLERS CONSOLE PRIOR TO RIG DRILLING OPERATIONS.
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Engineering
Issued 10 December 1999 Resolved
RE-CONFIGURE FUEL OIL SUPPLY AND RETURN LINES BETWEEN DAY TANK AND CEMENT SKID UNIT. NO SINGLE SECTION OF FLEXIBLE FUEL OIL PIPING TO EXCEED 30".
Condition: Unknown
Due 10 December 1999
Resolved 10 December 1999
Unknown
Issued 10 December 1999 Resolved
PROPERLY LABEL MOTOR CONTROLLERS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
INSTALL SAFETY RELIEF VALVE ON COLD START AIR COMPRESSOR BETWEEN COMPRESSORDISCHARGE AND ISOLATION VALVES.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Unknown
Issued 10 December 1999 Resolved
INSTALL GUARD FOR SIGHT GLASS ON LUBE OIL STORAGE TANK.
Condition: Unknown
Due 15 December 1999
Resolved 15 December 1999
Lifesaving
Issued 15 October 1998 Resolved
INSTALL ADDITIONAL GENERAL ALARM BELLS TO PROVIDE ADEQUATE COVERAGE OF ALL EXTERIOR LOCATIONS.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Fire Fighting
Issued 15 October 1998 Resolved
CROP AND RENEW WASTED FIRE HOSE RACK AT STATION #4, PROPERLY LABEL.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Construction/Loadline
Issued 15 October 1998 Resolved
CROP AND RENEW 2' X 6' SECTION OF BULKHEAD UNDER THE EXTERIOR WATERTIGHT DOOR TO GALLEY.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Unknown
Issued 15 October 1998 Resolved
COMPLETE ABS IMO SAFETY INSPECTION. PROVIDE COPY OF SAFETY CERTIFICATE, LOAD LINE, IOPP, AND CRANE INSPECTION TO [name withheld].
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Lifesaving
Issued 15 October 1998 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 110% OR ALTERNATE TEST ACCEPTABLE TO [name withheld].
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Lifesaving
Issued 15 October 1998 Resolved
HYDROSTATICALLY TEST BREATHING AIR CYLINDERS IN LIFEBOAT.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Lifesaving
Issued 15 October 1998 Resolved
CROP AND RENEW HAND RAILS WHERE WASTED / HOLED NEAR LIFERAFT #2.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Electrical
Issued 15 October 1998 Resolved
PROPERLY INSTALL ELECTRICAL WIRING IN PAINT LOCKER.
Condition: Unknown
Due 15 October 1998
Resolved 15 October 1998
Construction/Loadline
Issued 2 October 1997 Resolved
REPAIR CLOSING DEVICE ON PORT SIDE DOOR TO THE MUD PIT ROOM.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Electrical
Issued 2 October 1997 Resolved
CLOSE ALL OPENINGS ON THE EDG PANEL.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Lifesaving
Issued 2 October 1997 Resolved
REPLACE ALL FADED, PAINTED AND DAMAGED LIFE RINGS.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Documentation
Issued 2 October 1997 Resolved
PROVIDE TRAINING MATERIAL AS REQUIRED BY 46 CFR 109.213.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Documentation
Issued 2 October 1997 Resolved
PROVIDE RECORD OF DRILLS AND TRAINING AS REQUIRED IN 46 CFR 109.213(h).
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
REPAIR #2 FIRE PUMP.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Engineering
Issued 2 October 1997 Resolved
REPLACE CRACKED FUEL LINES ON #3 AND #4 GENERATORS.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Engineering
Issued 2 October 1997 Resolved
REPLACE PORT SIDE FUEL TRANSFER HOSE.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Electrical
Issued 2 October 1997 Resolved
PROVE PROPER OPERATION OF THE EMERGENCY GENERATOR NORMAL POWER BREAKER.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
CROP AND RENEW WASTED FIREMAININ THE AREA OF THE FIRE PUMPS.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
RENEW PACKING IN #1 FIRE PUMP.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Lifesaving
Issued 2 October 1997 Resolved
CLEAN EXTERIOR OF THE LIFE BOATS.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Lifesaving
Issued 2 October 1997 Resolved
REPAIR THE ESCAPE LADDER ON THE PORT SIDE.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Electrical
Issued 2 October 1997 Resolved
REPLACE THE BURNED OUT LIGHTS ON THE HELO DECK.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Construction/Loadline
Issued 2 October 1997 Resolved
MAKE ALL REPAIRS REQUIRED BY ABS IN REPORT MC6509.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Documentation
Issued 2 October 1997 Resolved
AQUIRE THE COMPLETE TOTAL SAFETY FIRE SERVICING REPORT.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Lifesaving
Issued 2 October 1997 Resolved
CONDUCT A TEST OF THE TOTAL RIG SHUTDOWN AT THE NEXT RIG MOVE.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
INSTALL NOZZLES AND PROVIDE OPERATION INSTRUCTIONS FOR THE CO2 SYSTEM IN THE PAINT LOCKER.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Lifesaving
Issued 2 October 1997 Resolved
PROVE PROPER OPERATION OF ALL EYEWASH STATIONS.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Electrical
Issued 4 October 1996 Resolved
PERFORM FULL FUNCTIONAL TEST OF EMERGENCY GENERATOR LOW LUBE OIL TRIP, OVERSPEED TRIP, HIGH WATER TEMPERATURE ALARM, AUTOMATIC START UP, & AUTOMATIC BUS TRANSFER.
Condition: Unknown
Due 17 October 1996
Resolved 30 October 1996
Construction/Loadline
Issued 4 October 1996 Resolved
REPAIR, REMOVE, OR MAKE INACCESSIBLE WASTED EXTERIOR WALKWAY UNDERNEATH HELODECK.
Condition: Unknown
Due 17 October 1996
Resolved 30 October 1996
Electrical
Issued 4 October 1996 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL TRIPS ON ALL MAIN GENERATORS.
Condition: Unknown
Due 17 October 1996
Resolved 30 October 1996
Electrical
Issued 4 October 1996 Resolved
PROVE PROPER OPERATION OF HIGH WATER TEMPERATURE ALARM ON ALL MAIN GENERATORS.
Condition: Unknown
Due 17 October 1996
Resolved 30 October 1996
Lifesaving
Issued 4 October 1996 Resolved
PROVE PROPER OPERATION OF ALL MANUAL GENERAL ALARM ACTUATORS.
Condition: Unknown
Due 17 October 1996
Resolved 30 October 1996
Accommodation/Occupational Safety
Issued 4 October 1996 Resolved
PROVIDE APPROPRIATE SIGNS & EMERGENCY LIGHTING FOR BOTH DEAD END CORRIDORS IN LOWER LEVEL QUARTERS.
Condition: Unknown
Due 17 October 1996
Resolved 30 October 1996
Electrical
Issued 10 October 1995 Resolved
REPLACE LENS ON INTRINSICALLY SAFE LIGHT BELOW STBD CRANE.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Lifesaving
Issued 10 October 1995 Resolved
STENCIL GENERAL ALARM BELL BELOW STBD CRANE
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Construction/Loadline
Issued 10 October 1995 Resolved
REPAIR VALVE HANDLE OR PROVIDE CAP FOR DIRTY OIL TANK FILL IN ENGINE ROOM
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Electrical
Issued 10 October 1995 Resolved
REPAIR REVERSE POWER RELAY #4 GENERATOR
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Electrical
Issued 10 October 1995 Resolved
REPLACE EMERGENCY GENERATOR BATTERIES.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Fire Fighting
Issued 10 October 1995 Resolved
PROVIDE VENT CLOSURE FOR PAINT LOCKER.
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Lifesaving
Issued 3 October 1994 Resolved
RETURN PORT LIFERAFT TO ORIGINAL LOCATION AND RECONSTRUCT EMBARKATION AREA.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Lifesaving
Issued 3 October 1994 Resolved
ADJUST FOR PROPER OPERATION LIFEBOAT LIMIT SWITCHES.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Lifesaving
Issued 3 October 1994 Resolved
REPLACE PORT AFT RING BUOY.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Lifesaving
Issued 3 October 1994 Resolved
INSTALL EYE WASH STATION ON DRILL FLOOR.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Fire Fighting
Issued 3 October 1994 Resolved
REMOVE ATTACHMENTS TO DRILL FLOOR FIRE STATION IN ACCORDANCE WITH PANAMANIAN MODU RULES.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Construction/Loadline
Issued 3 October 1994 Resolved
CROP AND RENEW WASTED OVERHEAD STIFFENERS AT NO. 1 FIRE STATION.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Electrical
Issued 3 October 1994 Resolved
REPLACE TACH'S ON #2,3,4 MAIN GENERATORS.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Electrical
Issued 3 October 1994 Resolved
SECURE WIRING BEHIND DRILLERS CONSOLE.
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Documentation
Issued 22 September 1993 Resolved
REVISE MODU OPERATING MANUAL TO COMPLY WITH REQUIREMENTS OF 46CFR109 AND SUBMIT TO THE [name withheld], TEXAS NO LATER THAN 22NOV93.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Electrical
Issued 15 July 1985 Resolved
REPLACE BROKEN BOLTS ON ELMAGO BRAKE CONTROL SWITCH BOX LOCATED ON BACK BULKHEAD OF DRILL FLOOR.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Electrical
Issued 15 July 1985 Resolved
MAKE OPERABLE ALARM FOR AIR PURGE SYSTEM ON DRILL FLOOR ALL SYSTEMS THAT ARE NOT APPROVED ELECTRICALLY SAFE FOR LOCATION ARE TO BE AIR PURGED AND PROVIDED AND ALARM FOR LOSS OF AIR PURGE.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Electrical
Issued 15 July 1985 Resolved
REPLACE BROKEN EYS FITTING LOCATED UNDER MEET-RITE RECORDER STARBOARD SIDE OF DRILL FLOOR.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Electrical
Issued 15 July 1985 Resolved
REPLACE MISSING COVER ON ELECT BOX LOCATED IN MUD PIT ROOM.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Electrical
Issued 15 July 1985 Resolved
CHECK ALL ELECT SWITCH BOXES IN HAZARDOUS LOCATIONS FOR MISSING BOLTS REPLACE ALL THAT ARE MISSING.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Unknown
Issued 15 July 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAINS TO THE VESSEL, NORDRILL SEAHAWK, A7606629
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Electrical
Issued 15 July 1985 Resolved
PROPERLY RETIE ALL LOOSE ELECTRICAL CABLES IN WAY OF DRILL FLOOR PLASTIC TIE WRAPS ARE NOT ACCEPTABLE UNLESS WIRE IS SUPPORTED IN ATRAY.
Condition: Unknown
Due 15 July 1985
Resolved 15 July 1985
Electrical
Issued 4 April 1984 Resolved
REPLACE MISSING COVERS ON VARIOUS ELECTRICAL OUTLETS THROUGHOUT THE RIG.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Deck/Cargo
Issued 4 April 1984 Resolved
REPLACE THE FILL LINE IN THE PORT P-TANK ROOM WHERE FOUR(4) PATCHES ARE INSTALLED.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Electrical
Issued 4 April 1984 Resolved
INSTALL BLANKS OVER MISSING BREAKERS IN ELECTRICAL PANELS # 1 & 5.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984

Ownership record