Records from 2004 to 2024. Most recent: inspection, 25 April 2024.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020
Resolved
Emergency bus tie breaker switch broke on the main switch board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 15 June 2020
Resolved
Sewage line on main deck, starboard side, overhead leaks. Covered with absorbent pads and duct tape.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 June 2020
Resolved
Emergency fire pump packing was leaking excessively while operating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 June 2020
Resolved
De-scale and prove proper operation of pressure relieving device on DC heater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 15 June 2020
Resolved
Lagging was missing on orsin line (hot) on steam generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 June 2020
Resolved
Junction boxes for controls on port and starboard engine room supply air were wasting and missing covers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 June 2020
Resolved
Penetrations in between hold 6 and stair tower IWO frame 75 were inproperly packed and not tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2020
Resolved
Starboard side engine room exhaust louver would not close.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 June 2020
Resolved
Investigate exhaust leak (possible) IWO DC heater.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2020
Resolved
Starboard upper red navigation light not secure to the mast.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2020
Resolved
Port lower red navigation light not secure to the mast.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 15 June 2020
Resolved
Sewage transfer motor controller wire to portside engine room needs to be supported.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 July 2020
Resolved 9 July 2020
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 May 2019
Resolved
Means shall be provided for automatically giving audible warning of the release of fire-extinguishing gas into any space to which personnel normally have access. The alarm shall operate for a suitable period before gas is released. Pre-discharge delay setting does not allow enough time for personnel to safely egress from holds. Conduct servicing and set pre-discharge timers to the satisfaction of the attending CG Marine Inspector. 74 SOLAS II-2/8(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2019
Resolution: Vessel conducted sactisfactory pre-discharge timer tests in the presence of the attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2019
Resolved
Fire-fighting systems and appliances shall be kept in good working order and ready for immediate use. Low pressure CO2 servicing shows multiple discrepancies between designed pre-discharge & discharge times and the results from the tests. Provide servicing and faulty timer repairs to the satisfaction of the Marine Inspector. 74 SOLAS (14) II-2/14.2.1.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2019
Resolution: Timers were determined to not be faulty. The problem actually lay with the time delay settings for the adjustable pre-discharge delays. Cleared this deficiency and issued additional CG-835v, #43.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 May 2019
Resolved
Fire detection and fire alarm systems shall be kept in good order so as to ensure the required performance if a fire occurs. Smoke detection system on bridge and in fire control room are not operating properly. Provide servicing report and conduct testing to the satisfaction of the Marine Inspector. 74 SOLAS (14) II-2/14.2.1.1.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 May 2019
Resolution: Ship's personnel troubleshot panel, repaired, and tested in the presence of CG Marine Inspector; all sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 16 May 2019
Resolved
Means shall be provided for stopping ventilation fans and closing ventilators from outside the space in case of fire. Four out of six supply/exhaust automatic ventilator dampers do not properly close. Test all supply/exhaust ventilators in the presence of Coast Guard Marine Inspector and ABS. 74 SOLAS II-2/54(a) 701 a,c
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 May 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, etc. covered by the survey. Port bilge pump will not take suction. Prove proper operation to the Marine Inspector. 74 SOLAS (14) I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2019
Resolution: Port bilge pump was operated in the presence of CG Marine Inspector; all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2019
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization. The vessel does not have any servicing report for fixed foam fire fighting system, including foam analysis report. 74 SOLAS (14) II-2/14.2.2.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 30 May 2019
Resolution: ABS report# NN36727
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 16 May 2019
Resolved
Manholes and flush scuttles in position 1 or 2 shall be closed by substantial covers capable of being made watertight. Scuttle #3 IWO ammo hold does not properly secure. Prove proper operation to the satisfaction of the Marine Inspector. ICLL 66 I/18(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2019
Resolution: Scuttle #3 in way of ammo hold was operated in the presence of CG Marine Inspector; all sat.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 May 2019
Resolved
Emergency lighting shall be at every boat station on deck and oversides. Port side lifeboats embarkation emergency lighting is inoperative. 74 SOLAS II-1/26(a)(ii)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 May 2019
Resolution: Lifeboat embarkation emergency lighting was tested in presence of CG Marine Inspector; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, etc. covered by the survey. Vessel
only has 103 serviceable immersion suits on board. Total
persons on board limited to 95. 74 SOLAS (14) I/11
Action required: 705 - Other - as specified
Resolved 14 August 2019
Resolution: Received documentation, in the form of a CG-835, with ABS clearance of the deficiency under report #NN3672735.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, etc. covered by the survey. Provide OEM report with approvals for repairs made to lifeboat davits 2, 3 & 4. 74 SOLAS (14) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Resolution: ABS report # NN3672735
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. DC
Lockers 1 & 2 have portable extinguishers that are not
properly secured.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Resolution: ABS report # 3672735
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey.
WTD operating panel in cargo hold IWO cargo ramp has indicator light colors switched (should be green for closed and red for open). 74 SOLAS (14) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Resolution: ABS report # NN3672735
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 May 2019
Resolved
Means for securing the weathertightness shall be capable of being maintained in all sea conditions. Bosun store hatch cover gasket on the forecastle needs to be renewed. ICLL 66 I/19(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Resolution: ABS report # NN3672735
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 May 2019
Resolved
Ventilator openings shall be provided with weathertight closing appliances. Bosun store aft bulkhead ventilation closure gasket needs to be renewed. ICLL 66 I/16(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Resolution: ABS report # NN3672735
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Port fuel door main deck solenoid valve is leaking hydraulic oil leading to a substantial amount accumulating on the deck. 74 SOLAS (14) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
Each circuit shall be protected by an overload protective device of an appropriate type based on its current carrying capacity. Two breakers on the EDG panel are overrated for the circuit. 74 SOLAS II-1/27(a)(vii)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
Resolution: Received documentation, in the form of a CG-835, with ABS clearance of the deficiency under report #NN3672735
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 May 2019
Resolved
Ventilator openings shall be provided with weathertight closing appliances. Low pressure CO2 compartment forward bulkhead ventilation closure will not seal. ICLL 66 I/19(4)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 July 2019
Resolution: Cleared by ABS. Report #NN3672735
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 16 May 2019
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization. Portable extinguisher FR15 has not been serviced. 74 SOLAS (14) II-2/14.2.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 May 2019
Resolution: ABS report # NN3672735
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 May 2019
No resolution recorded
Ventilator openings shall be provided with weathertight closing appliances. House port side forward head ventilation closure missing. ICLL 66 I/19(4)
Action required: 16 - Rectify deficiencies w/in 14 days
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements, machinery, equipment, etc. covered by the survey. One ammo hold sprinkler valve missing manual control. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2019
Resolution: Received documentation, in the form of a CG-835, with ABS clearance of the deficiency under report #NN3672735.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 May 2019
No resolution recorded
Penetrations through structural fire protection shall be adequately protected to ensure the required performance if a fire occurs. One gyro room cable transit through the deck does not have cable penetration system installation for fire protection. 74 SOLAS (14) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 May 2019
No resolution recorded
Penetrations through structural fire protection shall be adequately protected to ensure the required performance if a fire occurs. Reproduction room overhead cable penetration does not have cable penetration system installation for fire protection. 74 SOLAS (14) II-2/14.2.1.1.1
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2019
No resolution recorded
Lifebuoys shall be fitted with beckets securely seized. Multiple lifebuoys throughout the decks have grab lines that have sun rot, renew. SOLAS 74 III/21(d)
Action required: 50 - Rectify deficiencies w/in 30 days
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Starboard liferaft emergency lighting electrical cable needs to be renewed. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 July 2019
Resolution: Cleared by ABS. Report #NN3672735.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Bosun store aft bulkhead starboard exterior light needs to be renewed. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
Resolution: Cleared by ABS. Report #NN3672735.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Mount for 10 man liferaft located on the port fantail is wasted, renew. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
Resolution: Cleared by ABS. Report #NN3672735.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 16 May 2019
No resolution recorded
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Port side accommodation ladder rail/supports are wasted, renew. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 16 May 2019
Resolved
Ventilator openings shall be provided with weathertight closing appliances. Upper low pressure CO2 compartment closure does not close properly. ICLL 66 I/19(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2019
Resolution: Received documentation, in the form of a CG-835, with ABS clearance of the deficiency under report #NN3672735.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 16 May 2019
Resolved
Every lifeboat shall have one approved cover of a highly visible color capable of protecting the occupants against injury by exposure. Three out of four lifeboat canopies have wasted hardware, repair or replace. 74 SOLAS III/11(a)(xxvi)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2019
Resolution: Received documentation, in the form of a CG-835, with ABS clearance of the deficiency under report #NN3672735.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Mess deck stairtower self-closing door does not close. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
Resolution: Cleared by ABS. Report #NN3672735.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 May 2019
Resolved
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Lighting fixtures at the top and bottom of cargo hold 4A stairtower are missing covers. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 July 2019
Resolution: Cleared by ABS. Report #NN3672735.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 16 May 2019
No resolution recorded
No change shall be made to the structural arrangements,
machinery, equipment, etc. covered by the survey. Provide repair proposal for cargo hold 4A structural fire protection. Remove standing water and evaluate wastage of structural members. 74 SOLAS (14) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 16 May 2019
Resolved
The normal equipment of every lifeboat shall consist of 3L of fresh water for each person the lifeboat is certificated to carry. Each lifeboat had approximately 2L of water per person, including the desalinization pumps. 74 SOLAS III/11(a)(xiii)
Action required: 10 - Deficiency Rectified
Resolved 23 May 2019
Resolution: ABS report # NN3672735
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 16 May 2019
Resolved
The normal equipment of every lifeboat shall consist of 10,000 kJ of food for each person the lifeboat is certificated to carry. Each lifeboat contained food rations with compromised vacuum seals. 74 SOLAS III/11(a)(xii)
Action required: 10 - Deficiency Rectified
Resolved 23 May 2019
Resolution: ABS report # NN3672735
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 16 May 2019
Resolved
Lifeboats shall be equipped to meet the requirements of SOLAS. Lifeboat equipment contained expired batteries & first aid items and inoperable flashlights. 74 SOLAS III/11(a)
Action required: 10 - Deficiency Rectified
Resolved 23 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 16 May 2019
Resolved
All ships 500 GT and upwards shall be fitted with a gyro-compass and appropriate repeaters. Vessel gyro-compass repeaters were displaying a variety of headings at different stations. 74 SOLAS (14) V/19.2.5
Action required: 10 - Deficiency Rectified
Resolved 17 May 2019
Resolution: Tech rep attended vessel and reset system with correct latitude input.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2019
Resolved
At least two lifebuoys fitted with self-activating smoke signals shall be capable of quick release from the bridge. Smoke signals were attached to lifebuoys with lanyards of incorrect length according to smoke signal installation instructions. 74 SOLAS III/21(g)
Action required: 10 - Deficiency Rectified
Resolved 17 May 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 May 2019
Resolved
All watertight doors shall always be ready to be immediately closed. Sliding watertight door located in shaft alley was not properly sealing. 74 SOLAS II-1/13(n)
Action required: 10 - Deficiency Rectified
Resolved 17 May 2019
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 16 May 2019
Resolved
Fire protection systems and fire-fighting system appliances shall be maintained ready for use. International shore connection components were stowed in separate locations w/in the DC Locker and the crew was unaware of their location (parts were located on random shelves mixed in with spare components). 74 SOLAS (14) II-2/14.1.1
Action required: 10 - Deficiency Rectified
Resolved 17 May 2019
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 16 May 2019
Resolved
Upon activation, vessel is to provide MMC's for all crew when vessel is fully manned IAW COI to the satisfaction of the attending Marine Inspector. 46 CFR 15.515(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2019
Resolution: Crew documents verified during ROS activation inspection by the attending CG Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 May 2019
No resolution recorded
Vessel does not keep up to date charts and publications while in ROS. Upon activation, provide up to date charts and publications to the satisfaction of the attending Marine Inspector. 33 CFR 164.33
Action required: 60 - Rectify deficiencies prior to movement
Resolution: Vessel charts and publication verified during ROS activation inspection by the attending CG Marine Inspector.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 16 May 2019
Resolved
Every crew member shall participate in at least one abandon ship drill and one fire drill every month. When a new crew is engaged, these drills shall be held before sailing. Upon activation, vessel is to conduct abandon ship and fire drills to the satisfaction of the attending Marine Inspector. 74 SOLAS (14) III/19.3.2
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2019
Resolution: Crew completed satisfactory fire and abandon ship drills during ROS activation inspection by the attending CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 16 May 2019
Resolved
Each boat shall be launched and maneuvered in the water by its assigned operating crew at least once every three months. Upon activation, each boat shall be launched and maneuvered in the water by its assigned operating crew. 74 SOLAS (14) III/19.3.3.3
Action required: 60 - Rectify deficiencies prior to movement
Resolved 25 July 2019
Resolution: Crew successfully launched lifeboat and maneuvered it in the water during ROS activation inspection by the attending CG Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 March 2019
Resolved
#3 lifeboat's hose between packing gland and shaft log is delaminating and cracking. Replace to OEMs recommendations.
SOLAS74(14 Cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 18 April 2019
Resolution: Hose has been replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 18 March 2019
Resolved
#3 lifeboat's engine appears to have an oil leak coming from head gasket, troubleshoot and repair to OEMs recommendations. Total persons limited to 48.
SOLAS74(14 Cons) I/11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2019
Resolved 18 April 2019
Resolution: Oil has been cleaned out and the engine was run for several minutes with no noticeable leaks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 February 2019
Resolved
While conducting lowering operations of #3 lifeboat, the brake belt bolt sheared during the break test. The bolt from #4 lifeboat brake was installed on #3 lifeboat brake to recover safely. #4 lifeboat brake for winch is inoperable. Replace winch brake belt bolt to OEM approval. Total persons aboard is limited to 48.
SOLAS74(14 Cons) I/11
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 May 2019
Resolution: Received a report from Palfinger (job number /VS12590) attesting to the new bolts and that they are approved for this service.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 February 2019
Resolved
Wastage was noted at the base of davit arms: #3 FWD, #4 AFT, and #2 FWD and AFT. #4 AFT top sheave mount has wastage as well. Provide ultasonic test report of areas from deck welds up two feet. Provide same testing for affected areas of #4 sheave mount. Provide OEMs approval of wastage or repair proposal.
SOLAS74(14 Cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 May 2019
Resolution: PALFINGER provided report that is in vessel file and images in MISLE
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 7 February 2019
Resolved
#4 lifeboat's hose between packing gland and shaft log is delaminating and cracking. Replace to OEMs recommendations.
SOLAS74(14 Cons) I/11
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 April 2019
Resolution: hose replaced
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 September 2018
Resolved
Vessel experienced a loss of propulsion involving both the port and starboard boilers. Additionally, a port boiler f/o pressure switch leaked causing a fire in the engine room. Vessel shall provide a written report from its Classification Society that details the cause of the casualties and corrective action to prevent recurrence to the satisfaction of class prior to departure. 74 SOLAS I/11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 March 2019
Resolution: Received ABS Survey Report # NN3569036 attesting to full repair.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 September 2018
No resolution recorded
Vessel experienced a casualty involving both port and starboard boilers. Vessel shall provide a report from its Classification Society detailing the cause of the casualty and corrective action to prevent recurrence to the satisfaction of Class. 74 SOLAS 14 I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2018 — due date passed with no resolution recorded
Resolution: Received notification from ABS Class Surveyor [name withheld] that the port and stbd boilers have been rectified. USCG MI's conducted a visual examination of the boilers while lit off; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 September 2018
Resolved
Vessel shall be towed by a minimum of two tugs of at least 9,000 aggregate total horsepower, or; your vessel shall be towed by a minimum of two tugs of at least 90 ton aggregate bollard pull.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 18 September 2018
Resolved 14 September 2018
Resolution: Vessel safely transitted to Talton pier with required tug escort.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 7 September 2018
Resolved
The power available provided by the vessel's emergency diesel (EDG) generator shall be sufficient to supply all emergency loads necessary for the safety of all on board in an emergency with due regard to operate services simultaneously. Vessel's EDG is unable to carry immediate and simultaneous loads as such would be encountered while under normal underway operations. EDG demonstrates that the generator overcompensates when loads are put on and taken off the generator without self correction. Demonstrate proper operation of the EDG prior to departure to the satisfaction of the attending Coast Guard Marine Inspector and attending ABS Surveyor. SOLAS 74 II-1/26
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 September 2018
Resolution: Cleared by class report with authorization from CID, [name withheld].
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 9 April 2018
Resolved
The Low pressure CO2 system level is below the amount required for the largest space. Add the proper amount of CO2 prior to loading cargo. To the satisfaction of Class and CG.
74 Solas (14) Chpt II-2/ Reg 14.2.1.2
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 10 April 2018
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 9 April 2018
No resolution recorded
The ships Fire Control Plan does not match shipboard arrangement. Update Fire Control Plan to the satisfaction of Class and CG.
74 Solas CHpt II-2/4
Action required: 705 - Other - as specified
Due 8 July 2018 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 9 April 2018
Resolved
Hospital Space does not have running hot water. Make repairs and demonstrate to Class and CG.
US Supplement to ABS rules, Section III.8
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2018
Resolved 10 April 2018
Engineering › Bilge Water Management System › Pump
Issued 9 April 2018
Resolved
The installed bilge system in the machinery space has unauthorized modifications, using pnuematic pumps to assist original centrifugal pumps. Obtain Class approval for modifications to the satisfaction of Class and CG.
74 Solas CDhapter 1/ Reg 10
Action required: 705 - Other - as specified
Due 8 July 2018
Resolved 8 September 2018
Resolution: Cleared by Class ABS with authorization by [name withheld].
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 9 April 2018
Resolved
Water tight door remote operating indicator located one deck above door is inoperative. Make repairs and demonstrate operation to the satisfaction of Class and CG.
74 Solas Chpt 1/10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2018
Resolved 11 June 2018
Lifesaving › Lifeboat › Propulsion Engine
Issued 29 January 2018
Resolved
All 4 Lifeboats were found to have deficiencies that do not meet the requirements for life-saving appliance and were not in working order ready for immediate use. All four lifeboats required to complete annual servicing from a certified/licensed manufacturer’s representative. Reports shall be provided to ACS (Authorized Class Society) and the USCG Marine Inspector (MI).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: All lifeboats fixed and all gear accounted for.
Lifesaving › Inflatable Liferafts › Servicing
Issued 29 January 2018
Resolved
All life-rafts must be serviced and placed on station to the satisfaction of ACS and USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: All life rafts have been serviced and placed back into position
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 29 January 2018
Resolved
Ship’s smoke detection system disarmed and power secured. Provide approved third party servicing certificate and demonstrate proper operation to the satisfaction of ACS and the USCG MI.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2018
Resolution: Inspected smoke detection system and associated Harris Fire Protection servicing certificate dated 27MAR2018; all sat.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 January 2018
Resolved
Stair tower #501 self-closing door does not close. Repair to the satisfaction of ACS and USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: Tested sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 29 January 2018
Resolved
Power Panel doors across vessel are in general disrepair and do not allow easy access for securing power in case of emergency. Repair to the satisfaction of ACS and USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 January 2018
Resolved
Main deck passageway stair tower door has penetration next to fire damper #62 and General Alarm 47GA. Demonstrate proper operation to the satisfaction of ACS & USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 January 2018
Resolved
Stair tower door next to locker 513 and next to crew lounge found duct taped at kick-out panel. Repair to the satisfaction of ACS and USCG MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 29 January 2018
Resolved
Fire damper #13 inoperable (painted open). Demonstrate proper operation to the satisfaction of Class and USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 March 2018
Resolution: Tested SAT.
Stability › Watertight Integrity › General
Issued 29 January 2018
Resolved
Two ventilation trunks above the bow thruster space w/ substantiated metal wastage: major source of down flooding. Repair to the satisfaction of the ACS and USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: New ventilation installed and all hardware installed.
Fire Fighting › Ventilation Systems › Fans
Issued 29 January 2018
Resolved
Supply & Exhaust Fans w/in the cargo holds (17 total fans) 5 are inoperable. Demonstrate proper operation of all supply and exhaust fans to ACS & USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: All fans witnessed operational and all dampners verfied in operation.
Engineering › Bilge Water Management System › Not Operational
Issued 29 January 2018
Resolved
Bilge system is in a state of disrepair and inoperable due to missing sections and valves; Make approved repairs to installed bilge system in engine room to satisfy regulatory requirements and class rules, as well as to the satisfaction of attending ACS and USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: Lifeboats have been repaired and all gear was found to be correct, Cleared item #1.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 29 January 2018
Resolved
Vessel is to provide MMC’s for all crew members when vessel is fully crewed IAW COI Manning to a USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: MMC's inspected.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 29 January 2018
Resolved
Vessel does not keep up to date charts and publications due to ROS status. Vessel must provide charts and publications to USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: New charts and pubs.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 29 January 2018
Resolved
Vessel is to conduct abandon ship and fire drill to the satisfaction of the USCG MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 April 2018
Resolution: Drills comducted to satisfaction CGMI.
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2018
Resolved
Dead-end wires identified on PORT and STBD bridge wings, repair to the satisfaction of ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2018
Resolved
Dead-end wires identified atop bridge, repair to the satisfaction of ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 29 January 2018
Resolved
No fire stop installed in Electrical Equipment Room deck penetration on Bridge. Make appropriate repairs to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 February 2018
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Fixed Deck Foam System › Main Control Station
Issued 29 January 2018
Resolved
The #2 Fire Fighting Foam Station Supply Line supplying capabilities to the Helo Deck is compromised (hole). Provide repair proposal to ACS and USCG [name withheld] review and permission to proceed, repair to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Piping was replaced, All SAT.
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2018
Resolved
On STBD aft end of Helo deck, hanging wires improperly secured. Repair to the satisfaction of ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2018
Resolved
Lightbulb missing/damaged for Bridge watertight door indicator. Replace/demonstrate to the satisfaction of the ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Replacd, All SAT
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 January 2018
Resolved
Remove non-refillable refrigerant bottles from ship in RM 403 & LPCO2 room to the satisfaction of ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All Bottles removed.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 29 January 2018
Resolved
Hospital Head – The hospital shall have a working toilet, bathtub/shower and washbasin. Demonstrate proper working facilities to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Toilet worked all sat.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 29 January 2018
Resolved
No Fire stop in deck penetrations in electrical trunk room 407. Repair to the satisfaction of the attending ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Construction/Loadline › Penetrations › Pipe Flange
Issued 29 January 2018
Resolved
U- bolt missing on piping at Frame 123. Replace/Repair to the satisfaction of ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected u-bolt pipe bracket; all sat
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 January 2018
Resolved
Mounting brackets found wasted for High Pressure CO2 for FWD BOSUN Storage space (2 Bottles). Repair/replace to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Brackets replaced, All SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 January 2018
Resolved
Eye wash solution in dry stores passageway expired. Replace to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: New Bottle, with good expiration date installed, All SAT.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 29 January 2018
Resolved
All fire extinguishers in galley were expired/non-compliant. Provide compliant extinguisher in galley at all times to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Extinguishers were serviced, All SAT.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2018
Resolved
Place cover on overhead light in locker 562 to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: New covers installed, All SAT.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 29 January 2018
Resolved
Standing water in Crew 7 SNR space. Remove all excess water from space to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Water removed, All SAT.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 29 January 2018
Resolved
Aft deck head has 2” of standing water on deck. Remove all excess water from space to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Water removed, ALL SAT.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 January 2018
Resolved
Emergency eye wash station in Battery Shop & Electrical Stowage room Remove securing directions and leave decon station in operation at all time to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: ALL SAT.
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 29 January 2018
Resolved
Fuel overflow containment (12 for 104 port side) plug wasted. Repair/replace to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected fuel containment; new plug installed, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 January 2018
Resolved
Emergency Eye wash stations in all cargo holds inoperable. Ensure all eye wash stations are operable and have appropriate instructions to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 January 2018
Resolved
Nitrogen/refrigerant/O2 bottles adrift throughout vessel shall be properly stowed to the satisfaction of ACS and USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 9 April 2018
Resolution: All cylinders removed or secured.
Fire Fighting › Fire Hydrants › Condition
Issued 29 January 2018
Resolved
Fire stations 13, 50, & 51 on main deck stop valves experienced excessive leaking. Repair and make ready for immediate use to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected fire stations under pressure from emergency fire pump. No leaks detected; all sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
A/C line in room 403 found excessively corroded. Repair to original to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Lifesaving › Launching Appliances › Falls
Issued 29 January 2018
Resolved
Lifeboat #1 limit switch installed backwards. Install as designed and to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT
Engineering › Steering Gear System › Power Unit
Issued 29 January 2018
Resolved
Steering control failure alarm on Bridge. Demonstrate proper operation of steering console to the satisfaction of the ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 6 April 2018
Resolution: All required alarms witnessed sat.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 29 January 2018
Resolved
Smoke detection alarm on Bridge was found taped to not alarm in event of emergency. Demonstrate proper operation to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Tape removed; all sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 29 January 2018
Resolved
Ship does not have a current updated fire control plan. Provide an update Fire Control Plan to ACS and USCG MI for consideration and approval.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 9 April 2018
Resolution: CG-835 re-written under re-issued COI.
Construction/Loadline › Structures › Superstructure
Issued 29 January 2018
Resolved
Helo deck mountings loose and found corroded at dissimilar metal contact points. Provide report of inspection for Helo deck and connection points to vessel to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 6 April 2018
Resolution: Letter received verifying inspection fom Master
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 January 2018
Resolved
Cabin deck stair tower self-closing door does not close, minor adjustment. Prove proper operation to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAt.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
Hole in watertight door frame in refrigeration room (A/C room) 403. Provide repair proposal to ACS & USCG [name withheld] to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All Sat,
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
Watertight door in room 403 does not close. Demonstrate proper operation to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2018
Resolved
Ventilation duct in room 403 duct taped as patches. Repair to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
Room 403 fan drain line found broken and unsecured on deck. Repair to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 29 January 2018
Resolved
Instructions at lifeboat embarkation station missing at #3 lifeboat. Provide instructions to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected lifeboat instructions at embarkation station; all sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
Galley 480v power panel door doesn’t close (panel P57). Repair to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: New closing mechanism installed, All Sat.
Electrical › Electric Supply System (service) › Transformer
Issued 29 January 2018
Resolved
After market transformer installed in dry stores passage way provide proof of CG accepted third party approval of the installation: UL listed, FM, etc.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Transformer removed, All SAT.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 29 January 2018
Resolved
Forward sanitation wash unit in galley out of commission. Demonstrate proper operation to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Tested SAT.
Lifesaving › Immersion Suits › Quantity
Issued 29 January 2018
Resolved
Ship is missing seven immersion suits. Provide all required immersion suits for inspection to ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Crew showed 7 new immersion suits to inspectors and Class, All SAt.
Stability › Weathertight Integrity › General
Issued 29 January 2018
Resolved
Vents at lifeboat station #3 corroded and not watertight due to hole in steel bulkhead. Repair to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 4 April 2018
Resolution: New nut and wrench were provided so bolt closest to the bulkhead could be closed.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 29 January 2018
Resolved
Diesel service tank containment at #4 lifeboat station has hole next to drain plug. Repair to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2018
Resolved
In the Chemical Storage Room (CBRD), there is a Supply Vent Soft Patch (STBD side). Repair to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Soft Patch replaced with new metal ducting, ALL SAT.
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2018
Resolved
In the CBRD locker, STBD aft above 2nd deck, there are holes in the ventilation. Repair to satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: New ducting installed, ALL SAT
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 29 January 2018
Resolved
Verify that the small air conditioning unit installed in the CBRD space has not compromised the structural fire protection boundary for that space. Provide information to ACS & USCG MI for further direction.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: A/C unit removed, new metal plated installed to seal bulkhead, All SAT.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 29 January 2018
Resolved
There is a penetration in the WTB – Frame 135 STBD side. Make WTB watertight to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Penetration sealed with approved material, All SAT.
Fire Fighting › Fixed High-Expansion Foam Fire Extinguishing System › Discharge Outlets
Issued 29 January 2018
Resolved
Fire Fighting Foam system nozzles sporadically missing throughout all cargo spaces. Verify operational readiness/good order of foam spray system throughout cargo holds to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: ALL SAT.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 29 January 2018
Resolved
Fire nozzle missing on spray system at Frame 95 PORT side. Verify operational readiness/ good order of spray system throughout cargo holds to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected spray nozzle installation; all sat.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 29 January 2018
Resolved
Random EEBDs off station- uncharged one in engine space. Ensure all EEBDs are on station and serviced throughout vessel to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 29 January 2018
Resolved
JP5 fuel tank vents wasted at deck & approx. 1.5’ above deck. Provide repair proposal to ACS & USCG [name withheld] review and approval to proceed, repairs must be to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Replaced, All SAt.
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 29 January 2018
Resolved
Wasted gooseneck on PORT side. Provide repair proposal to ACS & USCG [name withheld] review and approval to proceed, repairs must be to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Replaced, All SAT.
Fire Fighting › Ventilation Systems › Ducts
Issued 29 January 2018
Resolved
Plywood & duct tape in vent trunk at FR-M on deck 4, Cargo Hold 4A. Complete repairs and demonstrate proper operations to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
WTD #11 Operating Station, oil soaked & leaking. Complete necessary repairs and demonstrate proper operation of station to ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Witnessed operation of WTD #11 and inspected associated hydraulics; all sat.
Engineering › Steam Boiler (propulsion) › Drum Support Tubes
Issued 29 January 2018
Resolved
Missing valve handle on the port boiler's steam drum near the sight glasses; install new handle to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: Replaced, All SAT.
Fire Fighting › Means of Escape › Blocked
Issued 29 January 2018
Resolved
Unrestricted access to escape ladder near emergency fire pump is hindered due to missing frame to support deck plate; reinstall framing and deck plate to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 January 2018
Resolved
Valve handle on EDG's hot start supply spins freely without valve actuation; replace valve to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected installation of EDG hot start supply valve; all sat.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
Water tight door remote operating station one deck above door was not producing an indication of the door being closed when it was in fact closed. Make repairs to manufactures specifications' and intended designed operation. Demonstrate proper operation to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 9 April 2018
Resolution: CG-835 re-written under re-issued COI.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 January 2018
Resolved
Overhead light forward in shaft alley is permanently wired, but temporarily secured; mount light permanently and securely to prevent undue stress on wire to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Engineering › Steering Gear System › Cable
Issued 29 January 2018
Resolved
Bonding on top of rotary-vane steering system rubs when exercising steering system; mount to prevent chaffing to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: All SAT.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
A hole in the deck is allowing water to drip on two (2) separate motor controllers in the machinery space; one (1) aft of propulsion turbine on stbd side and one (1) port side that control a ballast pump. Once dripping water is stopped remove tarp and bags from motor controllers to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: ALL SAT.
Electrical › Electric Generation Source (service) › Generator
Issued 29 January 2018
Resolved
There is ballast piping in the port side SSDG space that is showing signs of potential leaks once pressurized; renew piping or satisfactorily hydro in the presence of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: ALL SAT.
Electrical › Electric Supply System (service) › Cable
Issued 29 January 2018
Resolved
Submersible pump in aft engine room is permanently wired, but is hanging from a rope and not mounted properly; remove or mount properly to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected permanent installation of submersible pump; all sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 29 January 2018
Resolved
Junction box for engine room supply air fire damper needs to be mounted and wire raised off the deck to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 29 March 2018
Resolution: Inspected permanent installation of junction box and associated wiring; all sat.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 January 2018
Resolved
Small hydraulic leak on EDG cranking system make repairs to the satisfaction of ACS & USCG MI.
Action required: 705 - Other - as specified
Due 17 March 2018
Resolved 20 March 2018
Resolution: ALL SAT.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 January 2018
Resolved
Vessel/Company is to complete an ISM audit to the satisfaction of ABS Surveyor and Attending USCG Marine Inspector.
Due 17 March 2018
Resolved 9 April 2018
Resolution: ISM completed by ABS.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 1 June 2017
Resolved
Vessel shall provide MMC's w/proper endorsements for minimum required manning as per vessels COI prior to activating IAW 46 CFR 15.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2018
Resolved 8 September 2017
Resolution: Verified proper manning IAW the COI, all sat
Navigation › Piloting/Steering › Marine Charts
Issued 1 June 2017
Resolved
Navigation charts not corrected. Provide updated charts/ publications prior to vessel activation. Prior to departure. 33 CFR 164.33
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2018
Resolved 8 September 2017
Resolution: Verified vessel had up to date charts and nautical publications, all sat
Operations/Management › Drills/Instruction › Fire
Issued 1 June 2017
Resolved
Vessel shall conduct fire and abandon ship drills, to include lowering and launching of all (4) lifeboats, in presence of CG Marine Inspector prior to activating. SOLAS 74, Chapter III, Regulation. 19
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2018
Resolved 8 September 2017
Resolution: Witnessed the vessels crew preform a fire and abandon ship drill, all sat.