Records from 1985 to 2008. Most recent: inspection, 6 August 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
6 August 2008
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3286052
27 March 2008
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3171817
8 October 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2796280
25 August 2005
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2474408
23 August 2005
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2472146
23 August 2005
MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam · STCW 95 Exam · ILO-147 Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2474218
10 June 2003
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1813953
29 April 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 289630
15 October 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 282892
14 July 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 430483
17 December 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 410940
30 August 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 407343
18 September 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 382524
11 April 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 377330
8 April 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 365736
8 April 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 460595
30 March 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 365551
23 November 1993
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 522968
17 November 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 362385
17 February 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 356366
5 April 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 349811
7 March 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 349346
27 January 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 321039
5 August 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 310583
28 January 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 473640
9 January 1985
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 299871
Construction/Loadline › Structures › Manhole
Issued 27 March 2008
Resolved
The following items are no longer weather tight due to age and wastage. Water ingress is possible in these areas:
1) Port Oiler cabin and starboard fitter cabin deadlight covers are inoperable.
2) Starboard main deck door
3)All four doors at aft end on captain's deck and boat deck.
ICLL Annex I/23
ICLL Annex I/12
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Construction/Loadline › Structures › Air Pipe
Issued 27 March 2008
Resolved
Aft peak tank vent pipe leading through CO2 room is patched in two spots in CO2 room. This could cause flooding in the CO2 room patches fail. No non-conformity report submitted to company.
ICLL Annex I/20
ISM Code Part A 10,19
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Construction/Loadline › Structures › Ventilators
Issued 27 March 2008
Resolved
All natural ventilation vents (goose neck and flat) show evidence of age/wastage on closure devices. This could cause oxygen to help feed a fire. All vents should be inspected and rectified by class
SOLAS 04 I/11
Action required: 705 - Other - as specified
Due 27 April 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 March 2008
Resolved
Cracked lens found on starboard running light, replace lens to satisfaction of Flag/Class.
1972 COLREG Annex I/7
33 CFR 84.15
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 27 March 2008
Resolved
Ships crew could not produce ships bell when asked. Bell must be located / produced to satisfaction of Flag/Class.
1972 COLREG Part D/33, 33 CFR 86.23
Action required: 17 - Rectify deficiencies prior to departure
Due 28 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 27 March 2008
Resolved
Crew is not preparing voyage plan IAW ships bridge procedure guide section 2 and company safety management system.
SOLAS 04 5/34, ISM Code part A 5.1, STCW A-8/2.5
Due 27 April 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Electrical › Lighting (service) › Grounding Conductor
Issued 27 March 2008
Resolved
Foreword paint locker in Bosun store has extra paint stored in front of door causing door to be left open. Open paint is stored outside paint locker. Both explosion proof lights are missing grounding straps. A small hole found on the sprinkler system line outside the paint locker. The combination of these items could cause a fire to spread throughout bosun store.
SOLAS 74 Unam 2-2/5(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 27 March 2008
Resolved
Both firemen’s outfits are wasted. Heat reflective material has peeled off the suits and one suit is holed. During a fire, the firemen could be subjected to excessive heat. Inspection records indicate suits are in good condition. Rectify to satisfaction of Flag/Class
SOLAS 74 Unam II-2/14
ISM Code Part A-8,9,10
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Fire Fighting › Fire Hoses › Condition
Issued 27 March 2008
Resolved
One fire hose and two fire nozzles in engine room found in disrepair. Rubber lining in hose was fused together and cracked. The nozzles fog variation device were seized. In the event of a fire the fire teams may not have had working equipment. Inspection records indicate all hoses/nozzles are in good condition.
SOLAS 74 Unam II-2/5
ISM Code part A-8,9,10
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 27 March 2008
Resolved
The following self closing doors are inoperable or missing closing device.
1)Door to bridge from ladder well
2)Door from bridge to radio room
3)Entrance door to main ships laundry
The A-0 door to the drying room is missing the door handle and is tied open.
SOLAS 74 Unam II-2/37(f)
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 27 March 2008
Resolved
Approved ballast water handling log is not being used as per plan. No record of training has been conducted for crew. Ballast water reporting form shows incorrect number of tanks.
33 CFR 151.2035
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 27 March 2008
Resolved
Numerous hydraulic leaks were found on the foreward winch machinery in the Bosun store. Continued leaking causes a fire hazard and possible failure of winches. SOLAS 74 (04ConsEd) I/II
Action required: 17 - Rectify deficiencies prior to departure
Due 27 March 2008
Resolved 10 April 2008
Resolution: Team went out and inspected deficiancies noted on 3/27/2008. Inspection was satisfactory to Port State Control Examiners.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 23 August 2005
Resolved
Chief officers Cayman endorsement did not match his license. Resolve prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Resolution: Recieved letter of dispensation for chief mate from cayman islands. All is well.
Fire Fighting
Issued 15 October 2000
Resolved
FIXED FIRE EXTINGUISHING SYSTEM NOT FITTED IN CARGO HOLDS. NO EXEMPTION CERTIFICATION ISSUED BY FLAG STATE. PROVIDE COPY OF FAG STATE EXEPTION TO MSO SAN FRANCISCO PRIOR TO ARRIVIAL IN NEXT US PORT.
Condition: Unknown
Due 20 October 2000
Resolved 20 October 2000
Navigation
Issued 17 December 1997
Resolved
REPAIR ARPA RADAR PRIOR TO DEPARTURE.
Condition: Unknown
Due 17 December 1997
Resolved 19 December 1997
Fire Fighting
Issued 30 August 1997
Resolved
Have class determine the adequacy of the CO2 portable fire extinguisher forthe paint locker or replace with a foam/dry chemical extinguisher._x001C_ SOLAS 74amd II-2/18.7_x001C_
Condition: Unknown
Due 30 August 1997
Resolved 8 September 1997
Deck/Cargo
Issued 30 August 1997
Resolved
Make permanent repairs to the leaking hydraulic systems on the cargo hatch machinery; to include the various leaking rams, control stations and motors. Clean the oil from the decks to prevent entry into the water. Complete item prior to next U.S. port. 33 C.F.R. 151.10(b)
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Documentation
Issued 30 August 1997
Resolved
Update fire control plans to reflect locations of any moved equipment. Note in particular the International Shore Tie Connection._x001C_ SOLAS 74amd II-2/20
Condition: Unknown
Due 30 August 1997
Resolved 8 September 1997
Lifesaving
Issued 11 April 1995
Resolved
BRIDGE WING LIFE RINGS NOT THE REQUIRED WEIGHT. (4 KG)
Condition: Unknown
Due 11 April 1995
Resolved 14 April 1995
Lifesaving
Issued 11 April 1995
Resolved
RELEASE DEVICE ON BOTH LIFEBOATS NEED MAINT. STBD LIFEBOAT TOOK 30 MINUTES TO RELEASE.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Lifesaving
Issued 11 April 1995
Resolved
GUNWALE RAILS ON BOTH LIFEBOATS DRYROTTED AND BROKEN IN SEVERAL AREAS, ALLOWING THE GRABLINE TO DANGLE.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Lifesaving
Issued 11 April 1995
Resolved
WOODEN SEATS IN BOTH PORT AND STBD LIFEBOATS DRYROTTED AND FALLING APART.
Condition: Unknown
Due 18 September 1995
Resolved 18 September 1995
Navigation
Issued 5 August 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 August 1986
Resolved 5 August 1986
Navigation
Issued 5 August 1986
Resolved
VESSEL HAD ON BOARD A BRITISH ADMIRIALTY CHART 2839 THAT WAS NOT CURRENTLY CORRECTED UP TO DATE AS REQUIRED FOR THE AREA NAVIGATED.
Condition: Unknown
Due 17 November 1993
Resolved 18 November 1993