MAURY USCG vessel records Sign in
← All vessels

ED NOBLE

ED NOBLE is a 1984 mobile offshore drilling unit. The Coast Guard has recorded 43 inspections since 1984, most recently in April 1996, along with 42 deficiencies.

Records from 1984 to 1996. Most recent: inspection, 17 April 1996.

Built
1984
Last inspected
17 April 1996
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

244870
Flag
UNITED STATES
—
Maury page id
psix-244870

Inspections, by type

…with no type recorded10
Years with a record 12 calendar years (1984–1996)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4816 - Regulatory (Subpart C or D), Gross Ton
4816 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KNKBMMSI not assigned · expired · voluntarily equipped · granted 23 October 1991, cancelled 23 October 1996 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

17 April 1996 Administrative
Administrative · Activities Europe · Activity 1080961
26 February 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1193031
12 December 1995 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 878337
12 July 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 881532
2 June 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186973
30 May 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 5519
2 May 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182359
27 April 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 867178
19 April 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172241
23 March 1995 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848244
24 January 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1174734
20 December 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848889
13 July 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866157
14 March 1994 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856340
6 December 1993 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1157963
12 October 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143353
18 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1133886
28 October 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 945416
11 September 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1256441
7 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 958158
11 November 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943394
5 August 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941273
7 June 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1349714
20 May 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1238664
9 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921665
27 November 1990 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1224162
18 September 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925299
21 August 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1238318
16 August 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1240326
26 April 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1236587
23 August 1989 Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1043645
1 February 1989 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 898967
20 December 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1346265
22 November 1988 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 895133
19 February 1988 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 991582
22 August 1987 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338796
30 July 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1026346
16 January 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1317014
4 December 1986 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1023527
17 July 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1294874
2 June 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1298872
26 February 1986 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1304106
19 December 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 976267

Deficiency record · 42

Fire Fighting
Issued 23 March 1995 Resolved
PROVIDE [name withheld] WITH PROOF OF SERVICING ON THE FIXED HALON SYSTEM.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Lifesaving
Issued 23 March 1995 Resolved
PROVIDE [name withheld] WITH A COPY OF THE REVISED FIRE CONTROL AND LIFESAVING PLANS.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Deck/Cargo
Issued 23 March 1995 Resolved
PROVIDE [name withheld] WITH A COPY OF THE ANNUAL CRANE SURVEY FOR THE PORT AFT AND STBD CRANES.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Fire Fighting
Issued 23 March 1995 Resolved
PROVIDE [name withheld] WITH PROOF OF A STAISFACTORY HYDROSTATIC TEST ON THE SCBA BOTTLES IN THE CONTROL HOUSE.
Condition: Unknown
Due 23 March 1995
Resolved 23 March 1995
Lifesaving
Issued 14 March 1994 Resolved
PROVIDE LINE THROWING APPLIANCE.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Fire Fighting
Issued 14 March 1994 Resolved
HYDRO OR REPLACE 2 BV EXTINGUISHERS (NITROGEN BOTTLES) ON HELIDECK.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Lifesaving
Issued 14 March 1994 Resolved
PROVIDE 1 ADDITIONAL LIFERING (TOTAL OF TWO) WITH AN APPROVED SELF- ACTIVATING SMOKE SIGNAL IAW 46CFR108.515(d).
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Lifesaving
Issued 14 March 1994 Resolved
PROVIDE 12 PARACHUTE AND 12 HAND FLARES FOR #1 & 2 LIFEBOATS, AND 12 PARACHUTE FLARES IN CONTROL ROOM.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Lifesaving
Issued 14 March 1994 Resolved
SERVICE OR REPLACE 4 HYDROSTATIC RELEASING UNITS.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Electrical
Issued 14 March 1994 Resolved
PROVIDE MIO NY WITH THE CORRECTED 3RD DECK LIGHTING MODIFICATION DIAGRAM._x001C_
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Lifesaving
Issued 14 March 1994 Resolved
HYDRO OR REPLACE AIR BOTTLES IN #'S 1 & 2 LIFEBOAT.
Condition: Unknown
Due 14 March 1994
Resolved 14 March 1994
Documentation
Issued 18 April 1993 Resolved
PROVIDE PROOF OF PROPER ENDORSMENT OF LOADLINE CERTIFICATE AND CRANE RECORDBOOK TO [name withheld].
Condition: Unknown
Due 18 April 1993
Resolved 18 April 1993
Lifesaving
Issued 18 April 1993 Resolved
PROVIDE ANNUAL SERVICING ALL (04) 25 PERSON DAVIT LAUNCH LIFERAFTS AND REINSTALL ONBOARD PRIOR TO MANNING OF RIG.
Condition: Unknown
Due 18 April 1993
Resolved 18 April 1993
Lifesaving
Issued 18 April 1993 Resolved
UPON CREWING RIG, CONDUCT FIRE & BOAT DRILLS AND FORWARD COPIES OF LOG ENTRIES REGARDING SAME TO [name withheld].
Condition: Unknown
Due 18 April 1993
Resolved 18 April 1993
Navigation
Issued 7 April 1992 Resolved
REPAIR AND PROVE PROPER OPERATION OF OBSTRUCTION LIGHTS (NOT FLASHING) NOTIFY [name withheld] IN WRITING UPON COMPLETION.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Lifesaving
Issued 7 April 1992 Resolved
PROVIDE 1 HATCHET WITH LANYARD FOR #2, PORT LIFEBOAT.
Condition: Unknown
Due 7 April 1992
Resolved 7 April 1992
Construction/Loadline
Issued 7 June 1991 Resolved
REPAIR AND TEST #2 BILGE EDUCTOR.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Construction/Loadline
Issued 7 June 1991 Resolved
REPAIR AND TEST BILGE SUCTION CROSS CONNECT LINE.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Unknown
Issued 7 June 1991 Resolved
REINSTALL OVERHEAD GUARD FOR FORKLIFT.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Documentation
Issued 7 June 1991 Resolved
SUBMIT REVISED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Unknown
Issued 7 June 1991 Resolved
PROVIDE DRY CHEMICAL PORTABLE FIRE EXTINGUISHER FOR FORKLIFT FUELING STATION.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Engineering
Issued 7 June 1991 Resolved
REPAIR MALFUNCTIONS AND TEST #3 GENERATOR JACKET WATER HI-TEMP ALARM.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Engineering
Issued 7 June 1991 Resolved
REPLACE VOLTAGE REGULATOR FOR #1 GENERATOR.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Electrical
Issued 7 June 1991 Resolved
ADJUST SELF CLOSING DOOR IN MUD PIT ROOM.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Unknown
Issued 16 August 1990 Resolved
FINISH DRYDOCK EXAM
Condition: Unknown
Due 16 August 1990
Resolved 16 August 1990
Accommodation/Occupational Safety
Issued 26 April 1990 Resolved
MAKE ALL PRESSURE VESSELS READY FOR INTERNAL INSPECTION AND TEST RELIEF VALVES IN PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Fire Fighting
Issued 26 April 1990 Resolved
PROVIDE FOR TEST OF SHUTDOWN UPON OPERATION OF FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Fire Fighting
Issued 26 April 1990 Resolved
PROVIDE TWO OXYGEN/EXPLOSION METERS FOR EMERGENCY OUTFITS.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Engineering
Issued 26 April 1990 Resolved
PROVIDE ACCEPTABLE FUELING FACILITIES FOR DIESEL FORKLIFT.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Engineering
Issued 26 April 1990 Resolved
LABEL AND PROVIDE FOR OPERATIONAL TEST OF BILGE SYSTEM.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Fire Fighting
Issued 26 April 1990 Resolved
REMOVE NON-METALLIC EXPANSION JOINTS FROM DISCHARGE SIDE OF BOTH FIRE PUMPSAND HARDPIPE OR INSTALL SHOCK MOUNTS FOR PUMPS.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990 Resolved
TEST EMERGENCY GENERATOR OVERSPEED, LOW LUBE OIL ALARM, AND HIGH WATER TEMPERATURE ALARM.
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Electrical
Issued 26 April 1990 Resolved
REPAIR SUPPLY FAN NO.8 IN MUD PUMP ROOM AND GENERATOR ROOM FAN ON STBD SIDE
Condition: Unknown
Due 26 April 1990
Resolved 26 April 1990
Unknown
Issued 22 November 1988 Resolved
PROVIDE HEAT TEMPERED PYREX SIGHT GLASS ON LUBE OIL TANK IN MACHY ROOM TO REPLACE PLASTIC NOW INSTALLED.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Deck/Cargo
Issued 22 November 1988 Resolved
OPEN-UP FOUR DRY BULK TANKS FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Fire Fighting
Issued 22 November 1988 Resolved
REPAIR OR RENEW RELIEF VALVE ON FIRE PUMP IN COMPRESSOR ROOM SO THAT IS RE-LIEVES AT CORRECT PRESSURE.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Electrical
Issued 22 November 1988 Resolved
REPAIR EMERGENCY GENERATOR ENGINE ALARMS AND PROVE PROPER OPERATION.
Condition: Unknown
Due 22 November 1988
Resolved 22 November 1988
Unknown
Issued 30 July 1987 Resolved
MAKE UNIT AVAILABLE FOR DRYDOCK EXAM OR SPECIAL UNDERWATER EXAM IN LIEU OF DRYDOCKING PRIOR TO RETURNING THE RIG TO SERVICE AND NO LATER THAN THE NEXTBIENNIAL INSPECTION. A PROPOSAL MEETING THE REQUIREMENTS OF 46 CFR 107.265MUST BE SUBMITTED 30 DAYS IN ADVANCE IF SPECIAL UNDERWATER EXAM IS PLANNED.
Condition: Unknown
Due 30 July 1987
Resolved 30 July 1987
Lifesaving
Issued 4 December 1986 Resolved
MAKE OPERABLE THE #2 LIFEBOAT FORWARD LIMIT SWITCH WHICH HAS BEEN INSTALLEDUPSIDE DOWN.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Lifesaving
Issued 4 December 1986 Resolved
RENEW THE TORN GASKET ON THE STARBOARD FORWARD DOOR OF THE #2 LIFEBOAT.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Construction/Loadline
Issued 4 December 1986 Resolved
CONDUCT A CREDIT DRYDOCKING OR SPECIAL UNDERWATER EXAMINATION, OR OBTAIN ANEXTENSION FROM THE COGNIZANT OCMI.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Electrical
Issued 26 February 1986 Resolved
PROVIDE MARINE PACKAGE WITH PERMANENT PLUGS FOR ALL RAYCOR FUEL FILTERS.
Condition: Unknown
Due 26 February 1986
Resolved 26 February 1986

Ownership record