MAURY USCG vessel records Sign in
← All vessels

ORIENTAL KIKU

ORIENTAL KIKU is a 1982 freight ship. The Coast Guard has recorded 14 inspections since 1985, most recently in September 2001, along with 28 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1985 to 2001. Most recent: inspection, 10 September 2001.

Built
1982
Last inspected
10 September 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7433191 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
244899
Flag
BAHAMAS, THE
—
Maury page id
psix-244899

Inspections, by type

…with no type recorded14
…past their stated due date1
Years with a record 9 calendar years (1985–2001)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8203 - Regulatory (Subpart C or D), Gross Ton
6214 - Regulatory (Subpart C or D), Net Ton
14241 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 14

10 September 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293661
6 August 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 441673
27 November 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 397853
5 November 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 397044
18 June 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337795
12 March 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 473998
26 June 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 331161
31 March 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 322343
21 December 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 473638
11 March 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 314680
19 November 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 475995
21 July 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 515607
11 February 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 306956
8 August 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 303584

Deficiency record · 28

Fire Fighting
Issued 10 September 2001 Resolved
0720 Vessels fire fighting appliance for SCBA missing both spare bottles (SOLAS 74A II-2 Reg.17.3)
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Navigation
Issued 10 September 2001 Resolved
1499 Steering ram NO.1 loose from mounts (SOLAS 74 reg 29 (a))
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Navigation
Issued 10 September 2001 Resolved
Steering gear has multiple small hydraulic leaks (SOLAS 74 II-2/2)
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Electrical
Issued 10 September 2001 Resolved
Wire end on steering gear not properly terminated. wires taped off with duct tape and dangling (SOLAS 74 II-1/27(a))
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Construction/Loadline
Issued 10 September 2001 Resolved
0983 Steam pipe Econimizer overboard valve spool piece between valve and hull wasted and leaking (ILLC 66 Annex I/1)
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Engineering
Issued 10 September 2001 Resolved
1499 NO. 3 generator cooling water supply holed and leaking (SOLAS 74A REGI/11)
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Engineering
Issued 10 September 2001 No resolution recorded
All salt water cooling hoses are swollen and distended. (SOLAS 74A II-2/2) Replace hosed by 27SEP01 to the satisfaction of class.
Condition: Unknown
Due 27 September 2001 — due date passed with no resolution recorded
Lifesaving
Issued 10 September 2001 Resolved
0940 Main engine and bilges have excessive lube oil and fuel covering them (SOLAS 74 II-2/2)
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Construction/Loadline
Issued 10 September 2001 Resolved
0983 sewage overboard valve spool piece between valve & hull wasted holed &leaking water. Fitting is below the water line. (ILLC 66 Annex I/1) _x001C_ A cement box patch was placed on the line and a condition of_x001C_ class was issued to be repaired at the next dry dock.
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Navigation
Issued 5 November 1996 Resolved
RENEW/REPAIR FAULTY RUDDER ANGLE INDICATOR SO THAT THE EXACT POSITION OF THE RUDDER IS INDICATED AT THE PRINCIPAL STEERING STATION. (STEERING GEAR INDICATES A PORT 30 DEGREES RUDDER AND THE BRIDGE INDICATED A PORT 35 DEGREES RUDDER.) SOLAS 74 II-1/29(a)(vi)
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Fire Fighting
Issued 5 November 1996 Resolved
RENEW DETERIORATED HOSE TO THE SEMI-PORTABLE FIRE EXTINGUISHER LOCATED IN THE ENGINE ROOM PORT SIDE IN WAY OF THE PURIFIER ROOM._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Lifesaving
Issued 5 November 1996 Resolved
RENEW/REPAIR INOPERABLE LIFEBOAT DAVIT LIMIT SWITCHES FOR THE STARBOARD LIFEBOAT DAVIT. SEE SOLAS 74 III/29(L)
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Lifesaving
Issued 5 November 1996 Resolved
RENEW PORT AND STARBOARD LIFEBOAT DAVIT FALLS._x001C_ SOLAS 74 (AMENDED) III/19.4
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Lifesaving
Issued 5 November 1996 Resolved
RENEW RETRO-REFLECTIVE MATERIAL TO THE PORT AND STARBOARD LIFEBOATS. LIFEBOATS SHALL BE FITTED WITH RETRO-REFLECTIVE MATERIAL IN ACCORDANCE WITHSOLAS 74 (AMENDED) III/30.2.7 AND IMO RESOLUTION A.658(16)
Condition: Unknown
Due 7 August 1997
Resolved 7 August 1997
Fire Fighting
Issued 5 November 1996 Resolved
RENEW BROKEN SPRINKLER SYSTEM ACTIVATOR VALVE FOR THE FWD PAINT LOCKER._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 6 November 1996
Resolved 13 November 1996
Lifesaving
Issued 5 November 1996 Resolved
PROVIDE ONBOARD VESSEL, INSTRUCTIONS FOR THE ONBOARD MAINTENANCE OF ALL LIFESAVING APPLIANCES._x001C_ SOLAS 74 (AMENDED) III/19.3/52
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Fire Fighting
Issued 5 November 1996 Resolved
PROVIDE ON BOARD VESSEL, INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL THE INSTALLATIONS/EQUIPMENT FOR THE FIGHTING AND CONTAINMENT OF FIRE._x001C_ SOLAS 74(AMENDED) II-2/20
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Fire Fighting
Issued 5 November 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIRE MAIN (SPRINKLER) SUPPLY PIPING TO THE FWD PAINT LOCKER._x001C_ SOLAS 74 (AMENDED) II/2/21
Condition: Unknown
Due 6 November 1996
Resolved 13 November 1996
Engineering
Issued 5 November 1996 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY AIR COMPRESSOR LOCATED IN THE ENGINE ROOMLOWER LEVEL PORT SIDE, OUTBOARD THE #3 MAIN GENERATOR._x001C_ SOLAS I/11
Condition: Unknown
Due 6 November 1996
Resolved 13 November 1996
Fire Fighting
Issued 5 November 1996 Resolved
RENEW/REPAIR INOPERABLE FIRE MAIN ISOLATION VALVE FROM THE #2 MAIN FIRE PUMP. VALVE IS CURRENTLY FROZE IN THE SHUT POSITION._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 6 November 1996
Resolved 13 November 1996
Fire Fighting
Issued 5 November 1996 Resolved
PROVIDE ON BOARD AT LEAST 2 FIREMANS OUTFITS COMPLYING WITH THE REQUIREMENTS OF SOLAS 74 (AMENDED) II-2/17.1_x001C_ SOLAS 74 (AMENDED) II-2/17.3
Condition: Unknown
Due 6 November 1996
Resolved 13 November 1996
Electrical
Issued 5 November 1996 Resolved
SECURE AND PROPERLY SUPPORT THE ELECTRICAL CABLES ATTACHED TO THE MAIN MAST. WIRING SHALL BE SUPPORTED IN SUCH A MANNER AS TO AVOID CHAFING OR OTHER INJURY._x001C_ SOLAS 74 II-1/27(a)(vi)
Condition: Unknown
Due 19 November 1996
Resolved 18 November 1996
Navigation
Issued 31 March 1988 Resolved
33CFR164.33(A)(1)(II) CHART 11328 NOT CORRECTED.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Documentation
Issued 31 March 1988 Resolved
49CFR176.11(A) AMMONIUM HYDROXIDE STOWED IN NO. 1 LOWER HOLD AFT, INSTEAD OF ON DECK STOWAGE AS REQUIRED.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Navigation
Issued 31 March 1988 Resolved
33CFR164.33(A)(3)(I) NO TIDE TABLES ON BOARD.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Documentation
Issued 31 March 1988 Resolved
49CFR171.2(B) AMMONIUM HYDROXIDE, A 49CFR172.101 REGULATED MATERIAL WAS DESCRIBED IN ACCORDANCE WITH THE IMDG CODE.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Navigation
Issued 31 March 1988 Resolved
33CFR164.33(A)(3)(II) NO TIDAL CURRENT TABLES ON BOARD.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988
Navigation
Issued 31 March 1988 Resolved
33CFR164.33(A)(2)(I) NO U.S. COAST PILOT ON BOARD.
Condition: Unknown
Due 31 March 1988
Resolved 31 March 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.