Records from 1985 to 1998. Most recent: inspection, 4 December 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 10
4 December 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 423413
22 January 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 197960
22 January 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 399548
22 January 1997
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 757373
24 April 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 390373
19 February 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 520541
10 March 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 349564
25 May 1990
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 337475
9 June 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 330858
24 January 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 299992
Lifesaving
Issued 4 December 1998
Resolved
CLASS SURVEYOR TO VERIFY ADEQUACY OF STBD LIFEBOAT ENGINE. PRIOR TO SHIPS DEPARTURE._x001C_
Condition: Unknown
Due 5 December 1998
Resolved 7 December 1998
Fire Fighting
Issued 4 December 1998
Resolved
SERVICE/RENEW FIRE EXTINGUISHER IN BOS'N STORES MISSING SERVICE TAG
Condition: Unknown
Due 5 December 1998
Resolved 7 December 1998
Lifesaving
Issued 4 December 1998
Resolved
RENEW EXPIRED LIFEJACKETS LIGHTS
Condition: Unknown
Due 5 December 1998
Resolved 7 December 1998
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 4 December 1998
No resolution recorded
REPAIR WASH BASIN WATER TAP IN CREW'S HEAD (SECOND DECK STBD SIDE) PRIOR TONEXT U.S. PORT.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Engineering › Steering Gear System › Motor
Issued 4 December 1998
No resolution recorded
INSTALL MACHINERY GUARDS ON TWO REEFER COMPRESSORS IN STEERING GEAR ROOM ONSTBD SIDE.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Electrical
Issued 4 December 1998
Resolved
REPAIR LIGHT FIXTURE IN PAINT LOCKER (MISSING GLOBE AND CAGE SCREWS)
Condition: Unknown
Due 5 December 1998
Resolved 7 December 1998
Lifesaving
Issued 4 December 1998
Resolved
INSTALL NEW LIGHTS ON TWO LIFE JACKETS STOWED IN THE BOS'N STOREROOM.
Condition: Unknown
Due 5 December 1998
Resolved 7 December 1998
Accommodation/Occupational Safety
Issued 22 January 1997
Resolved
Better records need to be maintained on marpol V disposal.
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998
Lifesaving
Issued 22 January 1997
Resolved
REFLECTIVE TAPE WAS NOT MAINTAINED ON LIFE RINGS ON BOARD.
Condition: Unknown
Due 22 January 1997
Resolved 24 February 1997
Lifesaving
Issued 22 January 1997
Resolved
SIGNAL LIGHT ON STARBOARD LIFE RING IS OUT.
Condition: Unknown
Due 22 January 1997
Resolved 24 February 1997
Accommodation/Occupational Safety
Issued 22 January 1997
Resolved
UPON ARRIVAL TO CONDUCT PORT STATE CONTROL EXAM. CREW OF THE SUBJECT VESSEL WERE PAINTING AND SPILLED AN OIL BASED PAINT INTO THE WATER.
Condition: Unknown
Due 22 January 1997
Resolved 20 February 1997
Accommodation/Occupational Safety
Issued 22 January 1997
Resolved
Upon inspection of the Hospital space it was observed that there was improper storage.
Condition: Unknown
Due 22 January 1997
Resolved 21 February 1997
Documentation
Issued 22 January 1997
Resolved
OIL RECORD BOOK WAS NOT PROPERLY MAINTAINED.
Condition: Unknown
Due 24 February 1997
Resolved 24 February 1997
Fire Fighting
Issued 22 January 1997
Resolved
CREW ONBOARD VESSEL WAS NOT FARMILAR WITH FIRE FIGHTING EQUILPMENT.
Condition: Unknown
Due 22 January 1997
Resolved 24 February 1997