← All vessels
FMT 3037
Tank Barge · Barge class · Built 2000s · USCG Heartland District (CGD-H) · Other hulls named FMT 3037 · FLORIDA MARINE TRANSPORTERS, INC. operator of record, 2023
FMT 3037 is a 2001 tank barge. The Coast Guard has recorded 27 inspections since 2001, most recently in April 2026, along with 9 deficiencies and 1 casualty investigation in 2011.
Records from 2001 to 2026. Most recent: inspection, 22 April 2026.
- Built
- 2001
- Last inspected
- 22 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2011
Identity
1110027
24505
Flag
UNITED STATES
—
Maury page id
psix-24505
Inspections, by type
The 27 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)155.0 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 844 / net 844
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRINITY MARINE PRODUCTS · ASHLAND CITY, TN, UNITED STATES · built 2001
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it844 - Regulatory (Subpart C or D), Gross Ton
844 - Regulatory (Subpart C or D), Net Ton
844 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 27
22 April 2026
Examination of Repairs · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8341558
18 July 2023
Administrative Inspection · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7746127
4 May 2021
Administrative Inspection · COI Inspection · Drydock Exam · Examination of Repairs · Cargo Tank Internal · MTSA Verification · Internal Structural Exam
Physical examination · Marine Safety Unit Vicksburg · USCG Heartland District (CGD-H) · Activity 7188923
17 March 2020
Deficiency Check · Annual Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6925604
25 February 2020
Damage Survey · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6915475
29 May 2019
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6698122
20 June 2018
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6445310
8 June 2017
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6166230
19 April 2016
Drydock Exam · MTSA Verification · Internal Structural Exam · COI Inspection · Cargo Tank Internal · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5849803
30 July 2015
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5200791
12 August 2014
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4952227
5 June 2013
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4612218
18 July 2012
Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4383539
1 June 2010
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3754905
28 May 2009
MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3481769
27 April 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3193231
4 June 2007
Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2944809
16 May 2007
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2932230
21 April 2006
COI Inspection · Internal Structural Exam · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2630061
24 May 2005
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2366768
11 May 2005
Annual Inspection · MTSA Verification
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2356705
26 April 2005
MTSA Verification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 2343150
8 July 2004
Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2126345
29 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978972
8 July 2003
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1839972
12 April 2002
Periodic Inspection
Physical examination · Marine Safety Detachment Greenville · USCG Heartland District (CGD-H) · Activity 1604775
25 April 2001
Initial Construction-Excluding Oversight · Initial Certification · Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1382216
Deficiency record · 9
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 February 2020
Resolved
Vessel sustained damage to its port stern corner just below the deck. Damage consists of a 1/2" hole and 6-8" vertical fracture extending from the hole. Barge is permitted to proceed to IMTT Saint Rose, LA (LMR 118) to offload cargo and then proceed to FMT Shipyard in [name withheld] in Harvey, LA. If conditions or plans change, company shall notify nearest Coast Guard unit in area barge is located at the time. Company shall contact Sector New Orleans vessel inspections once the barge is offloaded to discuss repair plans. Repairs shall be completed after offloading current cargo and prior to loading next cargo, and to the satisfaction of attending Coast Guard marine inspector.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 3 June 2019
Resolved
Armored cable supplying #1 P/S and #2 P/S overfill alarms have excessive wear and do not meet regulation. Explosion proof box does not house cable in a secure way to eliminate vapor migration into the explosion proof box. Cargo vapor is escaping through fittings on the high-level alarm.
Ensure cable and explosion proof box both comply with standards outlined in 46 CFR 39.2009. Prior to loading cargo, prove compliance and proper operation of each high level alarm to attending USCG Marine Inspector.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 June 2018
Resolved
Junction box for high level alarm exposed to environment through cable opening on both STBD boxes and port FWD box. Vessel rep repaired during exam. Issued/cleared deficiency.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 18 July 2012
Resolved
Test hi level indictor prior to cargo ops.
Documentation › Logs/Records › Logbook (official)
Issued 21 April 2006
Resolved
Provide documentation stating that this vessel has been operated in freshwater for the last six months.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 11 May 2005
Resolved
No vessel response plan on barge
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 May 2005
Resolved
Draft marks worn, repaint
Communications › Visual Communication › Warning Sign (gangway)
Issued 11 May 2005
Resolved
Barge warning sign and flag faded. Repaint and restencil warning signage and flag
Pollution Prevention/Response › Response Equipment › Non-sparking Hand Scoops/Shovels/Buckets
Issued 11 May 2005
Resolved
No hand scoops in spill response kit
Casualty record · 1
30 March 2011Routine · role: Involved in a Marine Casualty · activity 3975603
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.