Records from 1984 to 2018. Most recent: inspection, 10 January 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 43
10 January 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6336647
13 December 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6057425
5 December 2001
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 772835
2 March 2001
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1060865
22 February 2001
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1059662
14 February 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1403299
19 January 2001
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1056635
25 September 2000
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 824790
22 September 2000
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 824785
10 April 2000
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1048917
1 March 2000
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1046101
28 January 2000
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1401174
21 May 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1413547
6 October 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836177
6 August 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 948196
24 June 1992
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 954976
25 November 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1259660
8 October 1991
Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 932849
29 August 1991
Hull Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 962748
3 April 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1227240
4 February 1991
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 994427
7 November 1990
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 912093
3 August 1990
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 913307
24 April 1990
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 909587
30 November 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 930041
11 August 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931443
21 July 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 900623
5 May 1989
Examination of Repairs
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1352805
27 April 1989
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1030698
21 April 1989
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1348456
20 September 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1201567
13 October 1987
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1016782
14 January 1987
Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1318080
13 January 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1318077
16 October 1986
Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1009404
2 October 1986
Credit Drydock · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1316613
20 December 1985
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1303746
15 April 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 983750
28 March 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1290416
22 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 979099
22 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1287772
14 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288476
9 November 1984
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1286573
Electrical
Issued 14 February 2001
Resolved
Inoperative reverse power relays iwo SSDG's #3 and #4. Engine room must be manned while SSDG's #3 or #4 are online.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Fire Fighting
Issued 14 February 2001
No resolution recorded
Missing fire dampers iwo steering room vents on after deck.
Condition: Unknown
Due 15 May 2001 — due date passed with no resolution recorded
Engineering
Issued 14 February 2001
Resolved
Make permanent repairs to #1 start air compressor.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Electrical
Issued 14 February 2001
No resolution recorded
Inoperative voltmeter switch iwo instrumentation switchboard for detecting step down transformer phase voltage.
Condition: Unknown
Due 15 May 2001 — due date passed with no resolution recorded
Electrical
Issued 14 February 2001
Resolved
Emergency light 01-43-2 inoperable.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Fire Fighting
Issued 14 February 2001
Resolved
Fire damper handles iwo E/R vents on bridge deck inaccessible.
Condition: Unknown
Due 14 February 2001
Resolved 14 February 2001
Construction/Loadline
Issued 28 January 2000
Resolved
RENEW CLOSURE LATCH FOR GOOSE NECK VENT 01-2-1, LOCATED ON BOW, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Lifesaving
Issued 28 January 2000
Resolved
PROVIDE RECEPTACLE FOR HAND HELD PLUG-IN SEARCHLIGHT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Lifesaving
Issued 28 January 2000
Resolved
PROVE PROPER OPERATION OF RESCUE BOAT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Lifesaving
Issued 28 January 2000
Resolved
PROVE PROPER OPERATION OF RESCUE BOAT DAVIT PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Lifesaving
Issued 28 January 2000
Resolved
LABEL RESCUE BOAT WITH VESSEL'S NAME AND MAX PERSONS CAPACITY.
Condition: Unknown
Due 31 January 2000
Resolved 31 January 2000
Documentation
Issued 28 January 2000
Resolved
AMMEND AND SUBMIT FOR APPROVAL AUTOMATION PROCEDURES TO REFLECT TEST PROCEDURES AFFECTED BY THE NEWLY INSTALLED ALTERATIONS (PROGRAMABLE ENGINE GENERATOR REGULATOR CONTROLLER) TO THE MAIN SWITCHBOARD.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 28 January 2000
Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR AND MONITOR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Documentation
Issued 28 January 2000
Resolved
PROVIDE CG APPROVED FIRE SAFETY CONTROL PLAN.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Engineering
Issued 28 January 2000
Resolved
SUBMIT PLANS FOR CG APPROVAL OF THE UNAUTHORIZED ALTERATIONS MADE TO MAIN SWITCHBOARD.(INSTALLATION OF THE PROGRAMMABLE ENGINE GENERATOR REGULATOR CONTROLS)
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Fire Fighting
Issued 28 January 2000
Resolved
INSTALL FIXED FIREFIGHTING SYSTEM FOR PAINT LOCKERS PRIOR TO STORING PAINT OR OTHER FLAMMABLE MATERIALS IN LOCKERS.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Lifesaving
Issued 28 January 2000
Resolved
PROVIDE 1500 FT OF AUXILARY LINE FOR THE LINE THROWING APPARATUS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Navigation
Issued 28 January 2000
Resolved
PROVE PROPER OPERATION OF ENGINE ORDER TELEGRAPH POWER FAILURE ALARM TO THESATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Electrical
Issued 28 January 2000
Resolved
MAKE PERMENANT REPAIR TO JUNCTION BOX COVER FOR PORTSIDE ANCHOR FLOOD LIGHTTO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Construction/Loadline
Issued 28 January 2000
Resolved
INSTALL MISSING DOOR HANDLE ON WEATHERTIGHT DOOR 01-13-2.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Lifesaving
Issued 6 August 1992
Resolved
PROVIDE UPDATE TO VESSEL'S POSTED LIFESAVING EQUIPMENT PLAN TO REFLECT ACTUAL LOCATION AND STATUS OF EQUIPMENT.
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Lifesaving
Issued 29 August 1991
Resolved
STRENGTHEN DECK UNDER STBD RAFT DAVIT AND RETEST DAVIT AT 150% OF SWL.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 3 August 1990
Resolved
PROVE PROPER OPERATION OF REMOTE SHUTDOWN FOR POWER VENTILATION. VENTILATION FANS WERE BEING RE-INSTALLED DURING THE INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Fire Fighting
Issued 3 August 1990
Resolved
PROVIDE PERMANENT MEANS OF CLOSING VENTS ON PAINT LOCKERS (CABINETS.) PROVECOMPLETE NOT LATER THAN 15 AUGUST 1990 (PRIOR TO SAILING.)
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Accommodation/Occupational Safety
Issued 3 August 1990
Resolved
MAKE PERMANENT REPAIRS TO STBD VENTILATION DUCT (SUPPLY) TO COMPARTMENT 01-63-1. MAINTAIN TEMPORARY REPAIR.
Condition: Unknown
Due 3 August 1990
Resolved 3 August 1990
Navigation
Issued 30 November 1989
Resolved
PROVIDE PROOF OF TO [name withheld] AND POST MANEUVERING CHARACTERISTS FACT SHEET IN PILOT HOUSE AFTER APPROPRIATE VESSEL MANEUVERING TESTS ARE COMPLETED AND FACT SHEET IS CREATED IN ACCORDANCE WITH 46 CFR 97.19
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
CONDUCT WEIGHT TEST OF RESCUE BOAT.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Deck/Cargo
Issued 30 November 1989
Resolved
PROVIDE INCREASED CONTAINMENT AROUND FUEL OIL VENTS AT NEXT REINSPECTION (MINIMUM OF 1 BARREL CONTAINMENT REQUIRED.)
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
SUPPLY RESCUE BOAT WITH EQUIPMENT AS PER SOLAS.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Accommodation/Occupational Safety
Issued 30 November 1989
Resolved
ALTER 0-1 DECK RAILS IN WAY OF AFT EMBARKATION LADDER PORT AND STARBOARD TOALLOW FOR PROPER ACCESS.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Lifesaving
Issued 30 November 1989
Resolved
PROVIDE EVIDENCE OF ACCEPTANCE OF RESCUE BOAT ILN ACCORDANCE WITH SOLAS.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Construction/Loadline
Issued 21 April 1989
Resolved
SUBMIT PLANS TO MSO HAMPTON ROADS FOR APPROVAL OF THE SEACHEST INSTALLATIONWHICH WAS DONE DURING THE CREDIT DRYDOCK OF 21APR89.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Engineering
Issued 21 April 1989
Resolved
PROVE THE OILY WATER SEPARATOR OPERATIONAL TO THE SATISFACTION OF A CG MARINE INSPECTOR PRIOR TO SAILING ON AN INTERNATIONAL VOYAGE OR BY 21MAY89.
Condition: Unknown
Due 21 April 1989
Resolved 21 April 1989
Engineering
Issued 2 October 1986
Resolved
REPAIR OR REPLACE, AS ORIGINAL, PORT & STBD MAIN MOTOR COOLING WATER REGULATIONS.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Engineering
Issued 2 October 1986
Resolved
DEMONSTRATE ALL MODES OF OPERATION OF THE FUEL OIL PURIFIER.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Engineering
Issued 28 March 1985
Resolved
BILGE SYSTEM STOP/CHECK VALVES HAVE IMPROPER VALVE GUIDES WHICH PREVENT PROPER OPERATION OF THE SYSTEM; REPAIR SAME.
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Deck/Cargo
Issued 9 November 1984
Resolved
PROVIDE CONTAINMENT OF AT LEAST ONE-HALF BARREL FOR OILY WASTE TANKS, 4-66-1 AND 4-66-2 VENTS.
Condition: Unknown
Due 9 November 1984
Resolved 9 November 1984
Electrical
Issued 9 November 1984
Resolved
INSTALL EMERGENCY LIGHTS IN THE FOLLOWING LOCATIONS: A. MAIN GENERATOR HALON STORAGE ROOM B. SURTASS HALON STORAGE ROOM C. STORAGE ROOM 1-6-3.
Condition: Unknown
Due 9 November 1984
Resolved 9 November 1984
Accommodation/Occupational Safety
Issued 9 November 1984
Resolved
PROVIDE RELIEF DEVICE FOR EACH SEA WATER FLUSHING PRESSURE VESSEL LOCATED IN MAIN GENERATOR ROOM.
Condition: Unknown
Due 9 November 1984
Resolved 9 November 1984
Lifesaving
Issued 9 November 1984
Resolved
PROVIDE AND STOW 42 EXPOSURE SUITS.
Condition: Unknown
Due 9 November 1984
Resolved 9 November 1984
Accommodation/Occupational Safety
Issued 9 November 1984
Resolved
PROVIDE DOCUMENTATION THAT TRIM HEATERS FOR DISTILLER MEET UL STANDARD 174.
Condition: Unknown
Due 9 November 1984
Resolved 9 November 1984
Lifesaving
Issued 9 November 1984
Resolved
PROVIDE ONE AUXILIARY LINE 1500 FT. LONG, 3 IN. OR MORE CIRCUMFERENCE.