MAURY USCG vessel records Sign in
← All vessels

KEY LARGO PRINCESS

KEY LARGO PRINCESS is a 1984 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1985, most recently in January 2006, along with 59 deficiencies.

Records from 1985 to 2006. Most recent: inspection, 17 January 2006.

Built
1984
Last inspected
17 January 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCV2861
245228
Flag
UNITED STATES
367063820 (licence lapsed)
Maury page id
psix-245228

Inspections, by type

…with no type recorded8
Years with a record 21 calendar years (1985–2006)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCV2861MMSI 367063820 · expired · compulsorily equipped · granted 15 August 2015, cancelled 7 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GREAT WHITE Passenger (Inspected) · MISLE 431543 · 23 December 1995 · activity 100645

Inspection history · 53

17 January 2006 Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2568114
5 October 2005 Deficiency Check · Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2508146
18 October 2004 Re-Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2219892
14 October 2003 Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1918517
30 September 2003 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1918511
2 October 2002 Examination of Repairs
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1688437
24 September 2002 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1666713
22 October 2001 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1410682
4 October 2001 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1370370
16 February 2001 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1058854
16 October 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1361739
7 October 1999 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1445534
1 October 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1445533
1 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1119792
15 October 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 803074
23 October 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1110913
9 October 1997 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 775410
14 November 1996 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 865028
6 November 1996 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 858852
23 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 183698
23 October 1996 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162015
1 October 1996 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 832206
1 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1078635
23 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 100645
23 December 1995 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874745
24 November 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 880431
26 October 1995 Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879410
6 December 1994 Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 829026
3 December 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 29922
8 November 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1171120
10 October 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 870328
4 October 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 862911
22 August 1994 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 865194
1 October 1993 COI Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 845357
16 June 1993 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 836341
22 February 1993 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839167
20 January 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 831538
7 January 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1161688
30 January 1992 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1261901
30 September 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1245175
22 January 1991 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1302000
20 January 1989 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 897496
8 December 1988 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 897689
19 October 1988 Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 892201
21 September 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1042520
21 January 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1027306
12 November 1987 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023653
9 September 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1003802
18 February 1987 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1321680
4 September 1986 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1019726
26 February 1986 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 992516
15 April 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1290027
19 February 1985 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 976714

Deficiency record · 59

Construction/Loadline › Structures › Deck Plating
Issued 5 October 2005 Resolved
Make Permanant repairs to eroded area in overhead in #2 hole (stbd. side).
Action required: 705 - Other - as specified
Due 6 November 2005
Resolved 7 October 2005
Construction/Loadline › Hull › Bottom Plating
Issued 5 October 2005 Resolved
Clean fwd area of hull to make ready for closer inspection of plating.
Action required: 705 - Other - as specified
Due 12 October 2005
Resolved 5 October 2005
Lifesaving › Buoyant Apparatus › Lifeline
Issued 18 October 2004 Resolved
Renew Lifeline on starboard 22 person Buoyant Apparatus.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 26 October 2004
Resolution: Completed.
Lifesaving › Hand Flares › Expired
Issued 18 October 2004 Resolved
Renew 3 red and 3 orange hand held flares.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 26 October 2004
Resolution: Completed.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 18 October 2004 Resolved
Post Emergency Radio Broadcast Placard.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 26 October 2004
Resolution: Completed.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 October 2004 Resolved
Provide a USCG Approved First Aid Kit.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 26 October 2004
Resolution: Completed.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 October 2004 Resolved
Renew 2 adult size PFD's. Vessel is limited to not more than 130 total persons until completed.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 26 October 2004
Resolution: Completed.
Fire Fighting › Nozzles › Type
Issued 18 October 2004 Resolved
Provide a metallic nozzle for the fire hose located on the upper deck.
Action required: 705 - Other - as specified
Due 25 October 2004
Resolved 26 October 2004
Resolution: Completed.
Lifesaving › Buoyant Apparatus
Issued 30 September 2003 Resolved
Patch surface cracks on all 3 Lifefloats using manufacturer's approved patch kit.
Action required: 705 - Other - as specified
Due 14 October 2003
Resolved 14 October 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 30 September 2003 Resolved
Re-stencil vessel's name on 24 adult size PFD's. LEGACY COMPONENT DESC: Marking
Action required: 705 - Other - as specified
Due 14 October 2003
Resolved 14 October 2003
Resolution: Corrected.
Fire Fighting › Fire Pumps › Impeller
Issued 24 September 2002 Resolved
Repair and demonstrate proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 October 2002
Resolved 25 October 2002
Resolution: Corrected.
Construction/Loadline
Issued 4 October 2001 Resolved
Thoroughly grind out and re-weld weeping weld on bottom plating near starboard bow in way of MSD holding tank.
Condition: Unknown
Due 4 October 2001
Resolved 8 October 2001
Construction/Loadline
Issued 4 October 2001 Resolved
Re-weld the 5 fractured welds on longitudinal deck stiffeners located on inboard side of compartment forward of the engineroom, starboard side.
Condition: Unknown
Due 4 October 2001
Resolved 8 October 2001
Construction/Loadline
Issued 4 October 2001 Resolved
Renew wasted section of through-hull fitting for MSD discharge.
Condition: Unknown
Due 4 October 2001
Resolved 8 October 2001
Lifesaving
Issued 16 October 2000 Resolved
Replace the hydrostatic release on the EPIRB._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Lifesaving
Issued 16 October 2000 Resolved
Replace 5 adult and 1 child PFD._x001C_ _x001C_ The number of passengers is decreased to 127 adults and 13 children until this item is corrected._x001C_
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Engineering
Issued 16 October 2000 Resolved
Properly mark the port side emergency fuel shutoff valve.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Accommodation/Occupational Safety
Issued 16 October 2000 Resolved
Post a placard that states 47 max. passengers allowed on the upper deck._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Accommodation/Occupational Safety
Issued 16 October 2000 Resolved
Label the forward ladder "For Emergency Use Only"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Lifesaving
Issued 16 October 2000 Resolved
Replace the line around the B/As._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Construction/Loadline
Issued 16 October 2000 Resolved
Mark the lights for the high-level bilge alarms._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Fire Fighting
Issued 1 October 1999 Resolved
Install vent closures to the engine room._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1999
Resolved 19 October 1999
Electrical
Issued 1 October 1999 Resolved
Install a valve for the generator suction line._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1999
Resolved 19 October 1999
Electrical
Issued 1 October 1999 Resolved
Proplery secure the sea strainer for the generator._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1999
Resolved 19 October 1999
Engineering
Issued 1 October 1999 Resolved
Replace the starboard main engine exhaust cooling hose._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1999
Resolved 19 October 1999
Engineering
Issued 1 October 1999 Resolved
Provide chaffing protection for all engine room hoses._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1999
Resolved 19 October 1999
Accommodation/Occupational Safety
Issued 1 October 1999 Resolved
Properly secure the back gates._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1999
Resolved 19 October 1999
Construction/Loadline
Issued 1 October 1996 Resolved
Reweld or replace as necessary the foundation brackets for the potable water tank in the forward hold.
Condition: Unknown
Due 1 November 1996
Resolved 6 November 1996
Lifesaving
Issued 1 October 1996 Resolved
Make repairs to minor cracks in all buoyant apparatus.
Condition: Unknown
Due 1 November 1996
Resolved 6 November 1996
Lifesaving
Issued 1 October 1996 Resolved
install retroreflective material on all buoyant apparatus.
Condition: Unknown
Due 1 November 1996
Resolved 6 November 1996
Lifesaving
Issued 26 October 1995 Resolved
Replace retroreflective material on 20 adult lifejackets as directed._x001C_ Capacity of vessel is reduced to 112 persons total until this is completed.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Accommodation/Occupational Safety
Issued 26 October 1995 Resolved
Repair or replace portlights in way of both heads._x001C_ (inoperable or broken dogs)
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Construction/Loadline
Issued 26 October 1995 Resolved
Repair or replace engineroom vent louvers in way of stern deck.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Electrical
Issued 26 October 1995 Resolved
Correctly mount electrical relay under helm on stbd side.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 26 October 1995 Resolved
Post a lifejacket donning placard on each deck with lifejackets stowed on them.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Electrical
Issued 26 October 1995 Resolved
Remove bare bulb electrical fixture in way of aft end of canopy, upper deckrefreshment bar._x001C_ An approved fixture, as discussed with the inspector, may be installed.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Construction/Loadline
Issued 26 October 1995 Resolved
Install a proper bilge strainer on bilge pipe in forepeak.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Engineering
Issued 26 October 1995 Resolved
Replace PVC plastic pipe fuel caps with aluminum ones.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Lifesaving
Issued 4 October 1994 Resolved
Make minor repairs to buoyant apparatus per discussion with inspector. Noted several small holes and tears in body of floats. Also clean all for closer exam.
Condition: Unknown
Due 4 November 1994
Resolved 14 October 1994
Electrical
Issued 4 October 1994 Resolved
Install Ammeter, Voltmeter and Frequency meter (HZ) per discussion with inspector and as required by 46 CFR 183.10-5(g).
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Construction/Loadline
Issued 4 October 1994 Resolved
Repair (weld) pinhole leak in bilge manifold.
Condition: Unknown
Due 7 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 20 January 1993 Resolved
PROVIDE A SUITABLE METALLIC VALVE ON THE SEA SUCTION LINE FOR THE DIESEL GENERATOR.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Engineering
Issued 20 January 1993 Resolved
PROVIDE FLAME SCREENS FOR THE PORT AND STARBOARD FUEL OIL TANKS.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Lifesaving
Issued 20 January 1993 Resolved
MAKE REPAIRS TO THE 22 PERSON BUOYANT APPARATUS.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Lifesaving
Issued 20 January 1993 Resolved
PROVIDE AN ADDITIONAL 18 TYPE I LIFE PRESERVERS. THE VESSEL IS LIMITED TO 115 PERSONS TOTAL UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Construction/Loadline
Issued 20 January 1993 Resolved
PLUG UNUSED HYDRAULIC LINE IN THE AFT BULKHEAD AREA IN WAY OF THE MSD HOLDING TANK.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Construction/Loadline
Issued 20 January 1993 Resolved
PROVIDE PROPER BILGE STRAINERS IAW 46 CFR 182.25-10 FOR ALL COMPARTMENTS.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Construction/Loadline
Issued 20 January 1993 Resolved
MAKE COLLISION BULKHEAD WATER TIGHT WITH PERMANENT REPAIRS.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Fire Fighting
Issued 20 January 1993 Resolved
PROVIDE A 5 GPM PORTABLE FIRE AND BILGE PUMP WITH SUITABLE SUCTION AND DISCHARGE HOSES.
Condition: Unknown
Due 20 January 1993
Resolved 20 January 1993
Engineering
Issued 20 January 1989 Resolved
CLEAN INTERIOR OF PORT ENGINE BATTERY BOX.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Engineering
Issued 20 January 1989 Resolved
REMOVE OR REPLACE BOW THRUSTER DRIVE UNIT IN FORWARD COMPARTMENT DURING NEXT CREDIT DRYDOCK.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Engineering
Issued 20 January 1989 Resolved
REPLACE INSULATION BLANKETS ON BOTH PORT AND STARBOARD EXHAUST ELBOWS.
Condition: Unknown
Due 20 January 1989
Resolved 20 January 1989
Construction/Loadline
Issued 9 September 1987 Resolved
CLEAN AND RE-TORQUE WINDOW FRAMES IN BOTH UNDERWATER VIEWING BAYS.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Accommodation/Occupational Safety
Issued 9 September 1987 Resolved
RENEW SEA SUCTION STRAINERS FOR A/C ON PORT AND STARBOARD SIDES.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Navigation
Issued 9 September 1987 Resolved
RE-SEAL PORT TRANSDUCER.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Electrical
Issued 9 September 1987 Resolved
REMOVE ABANDONED ELECTRIC CABLE IN #2 HOLD.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Electrical
Issued 9 September 1987 Resolved
SUPPORT ELECTRICAL CABLES IN #2 HOLD.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Electrical
Issued 9 September 1987 Resolved
PERMANENTLY MOUNT AND HARD WIRE PORTABLE BILGE PUMP IN #2 HOLD.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Construction/Loadline
Issued 9 September 1987 Resolved
GRIND OUT AND RE-WELD FRAME BETWEEN 2ND AND 3RD WINDOW STARBOARD SIDE AT CENTERLINE AND BETWEEN 3RD AND 4TH WINDOW ON PORT SIDE AT CENTERLINE.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.