← All vessels
CYPRIA
CYPRIA is a 1984 freight ship. The Coast Guard has recorded 21 inspections since 1985, most recently in December 1998, along with 27 deficiencies — 2 with no resolution recorded — and 1 operational control.
Records from 1985 to 1998. Most recent: inspection, 16 December 1998.
- Built
- 1984
- Last inspected
- 16 December 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8307571 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FVS6
245367
Flag
LIBERIA
—
Maury page id
psix-245367
Inspections, by type
…with no type recorded20
…past their stated due date2
Years with a record
12 calendar years (1985–1998)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it12184 - Convention (Subpart B), Net Ton
24214 - Convention (Subpart B), Gross Ton
41517 - Dead Weight, Ton
8420 - Displacement, Ton
24214 - Convention (Subpart B), Gross Ton
41517 - Dead Weight, Ton
8420 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
16 December 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 423577
16 December 1998
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 808322
20 December 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 410898
20 December 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1117285
1 May 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 402862
17 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392951
4 December 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 384993
24 July 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 380238
12 May 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 358188
15 April 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 350272
10 January 1992
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 460987
20 June 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 344475
30 August 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 332271
13 August 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 325020
15 December 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 503335
14 August 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 317835
3 November 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 475291
22 May 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 309032
27 October 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 437952
7 March 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 300798
9 January 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300369
Deficiency record · 27
Documentation
Issued 16 December 1998
No resolution recorded
Provide Panama Certificate of Competency for 1st Engineer._x001C_ STCW/Flag State
Navigation
Issued 16 December 1998
No resolution recorded
Make current corrections to, or replace Coast Pilot and Light List._x001C_ 33 CFR 164.33(a)(2)(i)(ii)
Electrical
Issued 16 December 1998
Resolved
Remove portable lights in pump room no. 2 and no. 4.
Lifesaving
Issued 16 December 1998
Resolved
Hospital space used for storage of boxes._x001C_ ILO 147
Unknown
Issued 20 December 1997
Resolved
Crew not mustered for emergency drills as specified on Muster List._x001C_ SOLAS 74 (amended) regulations III/18.3.4 and III/53.2.7 & .8
Unknown
Issued 20 December 1997
Resolved
Crew unable to conduct satisfactory Fire and Abandon Ship drills._x001C_ SOLAS 74 (amended) regulations III/18, III/53 and XI/4
Lifesaving
Issued 20 December 1997
Resolved
Forward 6-person inflatable liferaft not properly marked, and operating instructions not posted._x001C_ SOLAS 74 (amended) Regulations III/39.7.3 and III/9.
Lifesaving
Issued 20 December 1997
Resolved
Hoisting apparatus not available for rescuing injured persons from cargo pump rooms. IBC 3.3.2 and 46 CFR 153.332
Electrical
Issued 20 December 1997
Resolved
Electrical wiring improperly spliced in forecastle paint locker._x001C_ SOLAS 74 (amended) regulation II-1/45, paragraphs 1.3, 5.6 and 10
Construction/Loadline
Issued 20 December 1997
Resolved
Loadline not painted in a contrasting color to that of the hull._x001C_ ILLC 66 Annex 1/8
Fire Fighting
Issued 20 December 1997
Resolved
Fireman's Outfits not properly stored. SOLAS 74 (amended) reg II-2/17.4
Lifesaving
Issued 20 December 1997
Resolved
Starboard lifeboat davit incapable of launching the lifeboat._x001C_ SOLAS 74 (amended) regulations III/15.2, III/19.2 and III/48.1.3
Fire Fighting
Issued 20 December 1997
Resolved
Fire Control Plan and Muster Lists inaccurate and out of date._x001C_ SOLAS 74 (amended) regulations II-2/20 and III/53
Deck/Cargo
Issued 17 July 1996
Resolved
Make permanent repairs to all leaking hydraulic rams, controls and windlasses. Clean oil to prevent entry into the water. Complete prior to return to a U. S. port. _x001C_ 33 CFR 151.10(b)
Fire Fighting
Issued 17 July 1996
Resolved
Make permanent repairs to the wasted F/F foam piping above the foam tank inthe steering gear space prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-2/8
Engineering
Issued 17 July 1996
Resolved
Make permanent repairs to the patched S/W manifold feed line in the port, fwd engineroom. Line is patched with a clamp. Complete prior to return toa U. S. port. _x001C_ SOLAS 74 amd II-1/26.1
Engineering
Issued 17 July 1996
Resolved
Make permanent repairs to the wasted cap on the M/E L/O heat exchanger prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-1/26.1
Accommodation/Occupational Safety
Issued 17 July 1996
Resolved
Repair the leaking drain line, stbd of the generators in the overhead priorto return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-1/26.1
Electrical
Issued 17 July 1996
Resolved
Repair the pulled wires on the fwd purifier solenoid valve prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-1/40.1.3
Fire Fighting
Issued 17 July 1996
Resolved
Clean the standing oil from the various trays under the oil pumps and strainers prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 amd II-2/2
Engineering
Issued 17 July 1996
Resolved
Provide mechanical plugs in the oil vent containments where plugged with wood prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 155.320
Fire Fighting
Issued 24 July 1995
Resolved
Make permanent repairs to all soft patches (9 +) on main deck fire main andballast piping, in way of # 2, 3, 5 cargo holds, prior to next U. S. port, per SOLAS Chap II-2, Reg 4
Engineering
Issued 24 July 1995
Resolved
Make permanent repairs to deck drain overboard piping, stbd side lower, at next scheduled drydock, per SOLAS Chap II, Reg 22(5)
Navigation
Issued 14 August 1987
Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO KALAMA, WASHINGTON, WITH A LIGHT LIST OF THE AREA NAVIGATED THAT WAS NOT CURRENTLY CORRECTED AS REQUIRED.
Accommodation/Occupational Safety
Issued 14 August 1987
Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO KALAMA, WASHINGTON, WITH A TYPE II MARINE SANITATION DEVICE THAT WAS NOT OPERATING PROPERLY, THERE-BY ALLOWINGRAW, UNTREATED SEWAGE TO BE DISCHARGED INTO U.S. WATERS.
Documentation
Issued 9 January 1985
Resolved
TESTS REQUIRED BY 33 CFR 164.25(Q) NOT LOGGED PRIOR TO ENTERING U.S. WATERS
Documentation
Issued 9 January 1985
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.