Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 19
27 April 2026
Administrative Inspection · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8356954
4 March 2026
Deficiency Check · Vessel Attendance
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8319506
12 May 2025
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8083980
29 April 2025
Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8075401
10 March 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8071889
23 October 2024
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8013402
3 May 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7892627
17 April 2023
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627779
21 March 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7627780
21 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7416552
19 April 2021
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178528
2 February 2021
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7130207
16 March 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6914570
30 April 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6625270
21 March 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6625260
16 April 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6372732
18 April 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6098635
21 March 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6104642
4 February 2016
DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5797816
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 April 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. During voyage Friday April 24th, vessel experienced a loss of propulsion due to incorrect alignment of fuel system. One tank of six was aligned to supply equipment but it ran out of fuel. Prior to operations, arrange a marine inspector to witness fuel system condition and alignment.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 27 April 2026
Resolved 18 June 2026
Resolution: Marine inspector witnessed one hour sea trial in Newport Harbor, vessel rep demonstrated fuel system alignment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 May 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, and the vessel from electrical hazards including fire. MI identified the following electrical hazards in the e/r: permanently mounted extension cords, an unsecured air compressor, improperly supported wire runs over the port tail shaft, and charred plug for stbd engine 'block heater'.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 4 March 2026
Resolution: MI verified securing of air compressor, unsupported wire runs have been properly supported, and block heater has been taken out of service.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025
Resolved 4 March 2026
Resolution: MI verified required EAP documentation was on board.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2025
Resolved
Both Port and Starboard exhaust ports were found to have substantial damage to the gel coat and fiberglass. Additionally, visible damage was found amidships on the port side of the fiberglass hull above the waterline. Properly repair all identified damaged sections of the external hull.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 12 May 2025
Resolution: Received images from vessel rep showing that repairs to the Port and Starboard exhaust ports had been complete. Repairs were found to be satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 29 April 2025
Resolved
Starboard propeller shaft bearing was found significantly deteriorated. Remove and replace shaft bearing.
Action required: 705 - Other - as specified
Resolved 12 May 2025
Resolution: Received images from vessel rep showing that repairs to starboard shaft bearing had been complete. Repair was found to be satisfactory.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 23 October 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position, or perform the duties and functions of a position, required by the vessel's Certificate of Inspection. Vessel's master was not enrolled in the marine employer's consortium. Provide proof of enrollment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Enrollment letter provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 October 2024
Resolved
The Certificate of Inspection must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely. COI not posted in conspicuous place for passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: COI posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 October 2024
Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Stability letter not posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Stability letter posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 October 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. Vessel's Radiotelephony Certificate is expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Radio telephony certificate issued.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 October 2024
Resolved
The installation and location of a portable fire extinguisher must be to the satisfaction of the Officer in Charge, Marine Inspection. Forward salon extinguisher was not properly mounted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Extinguisher mounted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Cooling lines outboard of the port main engine are supported with plastic tie wraps.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Cooling lines properly supported.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 October 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Dead end wires found in front of compass. Wires in emergency fuel shutoff cabinet require appropriate connections and to be in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Wires properly terminated.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 23 October 2024
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2), Installed radio is not programmed with an MMSI and does not have GPS location input as required.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: MMSI and GPS corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 October 2024
Resolved
Vessel does not meet IFR Overnight Accommodation requirements, as such, permanent signage must that indicates the below deck berthing areas are not to be used as overnight accommodation spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 November 2024
Resolved 18 November 2024
Resolution: Signs posted and COI amended.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 March 2023
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MI found the installed hydrostatic release unit on the IBA, expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2023
Resolved 21 March 2023
Resolution: HRD renewed. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 March 2023
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MI found the installed hydrostatic released unit on the EPIRB expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2023
Resolved 21 March 2023
Resolution: HRD replaced. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 21 March 2023
Resolved
Each ring life buoy on a vessel must be approved in accordance with 160.050 in sub chapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. MI found ring life buoy not installed in correct mounting bracket and not readily accessible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 8 April 2023
Resolution: Recieved Pictures. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 21 March 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria as indicated by the vessel's stability letter, the MAXIMUM number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. MI found no passenger marking on the upper deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 8 April 2023
Resolution: Recieved picures. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 21 March 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts, U.S. Coast Pilot [name withheld] list and Tide tables. MI found out of date charts, U.S. Coast Pilot, CG Light list and Tide tables. Vessel unable to produce proof of up-to-date nautical charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 22 March 2023
Resolution: All sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 21 March 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2023
Resolved 21 April 2023
Resolution: Recieved picture of MROP. All sat.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 February 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 February 2021
Resolution: Received evidence of new battery.
Engineering › Diesel Engine (propulsion-direct drive) › Seal
Issued 21 March 2017
Resolved
Make repairs to engine so that it is oil-leak free.
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 20 April 2017
Resolution: Operator tightened oil return line leading to sump.