Records from 2016 to 2023. Most recent: inspection, 4 April 2023.
Documentation record
Registered dimensions (L × B × D)38.2 ft × 13.0 ft × 5.9 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTOPAZ MARINE CORPORATION · OWINGS, MD, UNITED STATES · built 1984
Hull materialPlastic - MSIS Legacy
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPLYMOUTH, MA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 25 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 8
4 April 2023
Administrative Inspection
Administrative · USCG Northeast District (dp) · USCG Northeast District (CGD-NE) · Activity 7662591
30 September 2020
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7068426
7 May 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6678258
17 April 2019
Hull Examination · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6661258
25 April 2018
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6399224
1 May 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6138128
13 April 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6124371
28 April 2016
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5865302
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 May 2019
Resolved
The master and crew of a vessel will be familiar with the content and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. No emergency instructions were on board vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 10 May 2019
Resolution: Received copy of emergency procedures for vessel.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 7 May 2019
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: date of the drill and training, and general description of the drill scenario and training topics. Logs were not available for inspection.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: Drills were recorded in new log while CG was in attendace after witnessing satisfactory MOB and firefighting drills.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2019
Resolved
As appropriate for the intended voyage. a vessel must carry adequate and up-to-date: charts, U.S. Coast Pilot, CG Light List, tide tables, and current tables. Charts were outdated and no publications were available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2019
Resolved 10 May 2019
Resolution: Up-to-date charts and publications were provided.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 7 May 2019
Resolved
EPIRB must be tested monthly. No testing of EPIRB was recorded.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2019
Resolution: Educated vessel representative on proper way to test EPIRB. Vessel representative recorded testing in deck log.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 17 April 2019
Resolved
Appliances to ensure watertight integrity including hatches for openings in watertight decks must be in place. Hatches in deck are not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2019
Resolved 7 June 2019
Resolution: New gaskets were installed.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 26 April 2018
Resolved
Ampoule on fireboy has been painted. Renew ampoule or provide service report to prove proper operation.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 16 May 2018
Resolution: FIREX, INC inspected fixed fire system and found it to be satisfactory.
Communications › Radio Communications › EPIRB
Issued 26 April 2018
Resolved
EPIRB hydro does not show month of expiration. Provide proof or replace.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 May 2018
Resolved 16 May 2018
Resolution: A new EPIRB hydro was installed.
Communications › Radio Communications › EPIRB
Issued 1 May 2017
Resolved
EPIRB battery was expired. Vsl restricted to 3 NM.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 May 2017
Resolution: Vsl rep stated that EPIRB battery was replaced and is mailing the receipt.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2017
Resolved
Meds were expired. Replace.
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 8 May 2017
Resolution: Vsl rep stated that meds were renewed.