CALYPSO BREEZE

CALYPSO BREEZE is a 1985 passenger vessel (inspected). The Coast Guard has recorded 94 inspections since 1985, most recently in April 2026, along with 120 deficiencies, 1 operational control and 1 casualty investigation in 2025.

Records from 1985 to 2026. Most recent: inspection, 20 April 2026.

Built
1985
Last inspected
20 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ4546
245780
Flag
UNITED STATES
367760710, 367778730
Maury page id
psix-245780

Inspections, by type

…with no type recorded17
Years with a record 36 calendar years (1985–2026)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 26.0 ft × 6.0 ft
Registered tonnagegross 67 / net 54
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · MADISON, IN, UNITED STATES · built 1985
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 2 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Simplified, Gross Ton
54 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ4546MMSI 367778730 · active · compulsorily equipped · granted 23 March 2017, expires 23 March 2027
WDJ2684MMSI 367760710 · active · compulsorily equipped · granted 2 November 2016, expires 2 November 2026 · licensed under a name not among this hull’s recorded names (not shown)
WUX4514MMSI not assigned · expired · compulsorily equipped · granted 20 May 1998, cancelled 18 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 94

20 April 2026 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8334114
12 July 2025 Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8183684
12 July 2025 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8190920
14 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8111272
29 April 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8123714
9 August 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7897648
20 February 2024 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7844875
3 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7671686
17 August 2022 Examination of Repairs · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7431901
17 May 2022 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7431867
19 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7193796
1 September 2020 Administrative Inspection · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7025124
6 May 2020 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6946974
14 February 2020 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6912219
14 February 2020 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6921014
16 February 2019 DAPI Audit · Administrative Inspection · In-Service Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6622256
3 April 2017 Uninspected Other · Examination of Repairs · Construction Oversight · Internal Structural Exam · Initial Construction-Excluding Oversight · Administrative Inspection · Hull Examination · Inclining Experiment
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6116542
29 November 2016 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6049518
14 April 2016 Administrative Inspection · Examination of Repairs · Drydock Exam · Spot Check · Internal Structural Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5854013
14 March 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5832774
2 December 2015 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5773982
8 October 2014 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5001486
12 June 2012 DAPI Audit
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 4344095
14 December 2010 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3910674
2 December 2010 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 3903324
21 June 2006 Examination of Repairs
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 2727528
14 December 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2551141
2 November 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2527014
4 October 2005 Internal Structural Exam · Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2502188
13 February 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2006311
10 September 2003 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1877123
20 June 2002 Deficiency Check · Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1636351
19 September 2001 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1451761
28 August 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1060756
28 August 2000 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1471601
26 August 2000 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 102482
2 August 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1052764
6 June 2000 Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1384495
19 September 1999 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1365486
18 September 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 97827
9 September 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 730835
2 September 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 783721
13 August 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 212945
2 August 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1416939
18 July 1999 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 27521
13 April 1999 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789167
8 April 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1384116
13 May 1998 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1408099
3 April 1998 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 788024
4 April 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1117112
17 April 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082653
1 April 1996 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1082660
26 May 1995 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 93851
3 April 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 879910
7 March 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170542
27 October 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1175984
16 May 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862264
4 May 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321279
10 May 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 844019
24 April 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1141169
27 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959180
7 April 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955561
18 March 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1010678
17 March 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 122212
27 February 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 952092
13 December 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264310
1 November 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1253687
2 August 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935878
3 July 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 937852
30 May 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934452
4 January 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899515
27 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 899382
19 October 1990 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 905342
12 September 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 913753
6 June 1990 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 918250
26 March 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1224618
14 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 925800
31 January 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 926417
20 October 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1193925
30 August 1989 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1195437
1 June 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1040037
28 April 1989 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 895305
12 January 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 888493
30 November 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1207161
2 August 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1341447
28 June 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1204137
7 May 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1351140
22 March 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 993851
19 February 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1022061
11 February 1988 Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1325222
4 February 1987 Drydock Extension · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1317672
10 July 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1292796
14 February 1986 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 999041
8 August 1985 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1295320

Deficiency record · 120

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 April 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. MI observed P/S Generators running after test activation of the system. Prior to PAX. 701c 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
Resolution: Received video of proper operation of fireboy.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 April 2026 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR Part 80. MI observed no GPS data input on VHF-DSC transmitter. Integrate GPS location data to meet the DSC capability requirements. 46 CFR 184.502 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 21 April 2026
Resolution: Operator provided photos of LAT LONG input in VHF transciever.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire. MI observed oil soaked rotating machinery guards on both P/S Generators. Secure source of leak. 46 CFR 182.100 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 5 May 2026
Resolution: Operator provided photos of clean windings. No leak identified. See documents.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2026 Resolved
Electrical equipment on an vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. MI observed main switchboard missing non-conductive matting. Replace. 46 CFR 183.200
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 21 April 2026
Resolution: Operator provided photo of switchboard matting.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 July 2025 Resolved
The OCMI may require that a vessel undergo additional tests and inspection deemed reasonable and necessary to determine the vessel and its equipment are suitable for the service in which they are to be employed. The vessel experienced a loss of DC power, which caused a loss of propulsion control and DC bridge navigation and safety equipment. All systems must be repaired, inspected, and tested to the satisfaction of the Coast Guard prior to carrying passengers. 46 CFR 176.840
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2025
Resolved 18 July 2025
Resolution: MI attended vessel and inspected repairs made to 12VDC electrical system affecting the port main engine. Verified proper operation of all equipment and gauges. CG-835v deficiency has been cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 May 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection and operation of all watertight closures in the hull, decks, and bulkheads. MI observed the watertight door in the machinery space did not seal properly. 46 CFR 176.802(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2025
Resolved 14 May 2025
Resolution: O/O sent video of watertight door working properly.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. MI observed missing protective covers on main fuses for helm and starboard battery installation. 46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 24 May 2025
Resolution: O/O sent photo of covers installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. MI observed missing protective covers on main fuses for helm and starboard battery installation. 46 CFR 183.200(b)
Action required: 10 - Deficiency Rectified
Due 28 May 2025
Resolved 14 May 2025
Resolution: Covers were installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards. MI observed 01 exposed wire near port main engine solenoid, hanging loose without any type of termination. 46 CFR 183.200
Action required: 10 - Deficiency Rectified
Due 28 May 2025
Resolved 14 May 2025
Resolution: Wire was removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 May 2025 Resolved
Except when individual pumps are provided for separate spaces, individual bilge suction lines must be led to a central control point or manifold and provided with a stop valve at the control point or manifold and a check valve at some accessible point in the bilge line. MI observed check valve for bilge system was not functioning properly and allowing water back into the bilge space. 46 CFR 182.510(c)
Action required: 10 - Deficiency Rectified
Due 28 May 2025
Resolved 14 May 2025
Resolution: Check valve was cleaned and is now operational.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 May 2025 Resolved
In the design of a control, interlock, or indicator circuit, the disconnect device and its connections, including each terminal block for terminating the vessel's wiring, must not have any electrically unshielded or uninsulated surfaces. MI observed the breaker panel in the machinery space had multiple empty circuits that were not blanked off. 46 CFR 183.330(i)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 24 May 2025
Resolution: O/O sent photos of blanks for panel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 April 2025 Resolved
Nothing is this subpart limits the marine inspector from conducting such tests and inspections he or she deems necessary to be assured of the vessels seaworthyness. The vessel must undergo a COast Guard in service inspection to evaluate the condition of the hull and structural members prior to carring passengers. 46 CFR 176.500b(1)iv
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2025
Resolved 30 April 2025
Resolution: In service inspection complete. No issues noted.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 May 2023 Resolved
Except as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc. shall be dripproof protected. Dripproof protected means that equipment and machinery is so constructed or protected that its successful operation is not interfered with when subjected to falling moisture or dirt. MI identified opening in STBD side of breaker panel in front of STBD main engine. 46 CFR 183.10-10 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 17 May 2023
Resolution: Received photo of hole in electrical panel being closed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 May 2023 Resolved
Flexible hose may be used provided it is fitted with suitable connection fittings and has a high resistance to saltwater, petroleum oils and vibration. MI identified dry-rotted fuel line on the Raycor filter for PORT generator. 46 CFR 182.20-40(a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 8 May 2023
Resolution: Vessel representative sent over satisfactory photos of Raycor hoses being replaced with required hose.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 May 2023 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. MI identified multiple ventilation closures for engine room on PORT and STBD that would not close. 46 CFR 181.20-35(a)
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Crew was able clean up ventilation closures and all closures were closing properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 May 2023 Resolved
All life preservers and ring life buoys shall be marked with the vessel's name. MI observed faded vessel name on life ring buoys. 46 CFR 185.30-5(c)
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Crew was able to properly and clearly mark life ring buoys with vessel name.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 3 May 2023 Resolved
Penetrations and openings in watertight bulkheads must have a means to make them watertight. MI observed class I watertight door in engine room not making a complete seal. 46 CFR 171.114(a)(2)
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Crew was able to tighten down the dogs on the door creating a proper seal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 May 2023 Resolved
The fixed power bilge pump shall be self-priming and may be driven off the main engine or other source of power. It shall be permanently connected to the bilge main and may also be connected to the fire main. MI observed E/R bilge suction was unable to pump water due to faulty check valve. 46 CFR 182.25-10(b)
Action required: 10 - Deficiency Rectified
Due 3 May 2023
Resolved 3 May 2023
Resolution: Crew was able to fix the check valve and bilge suction was able to properly pump water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2021 Resolved
13199 - Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. MI observed the fuel line from the filter to the pump on the port main engine was no longer in serviceable condition. - 46 CFR 182.720(e)(iii) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Replaced fuel line with new - all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2021 Resolved
02108 - Main distribution panels shall be of the dead front type where voltage to ground is in excess of 150 volts A.C. or 250 volts D.C. MI observed a missing cover from the breaker box in the engine room. - 46 CFR 183.10-15(f) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel represtentative installed distribution blank in open slot - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2021 Resolved
13199 - Installation shall be in accordance with 182.15-15. It (exhaust piping) shall be gas-tight throughout its length. MI observed exhaust gas leak on the port generator. - 46 CFR 182.20-20, 46 CFR 182.15-20 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel representative replaced exhaust gasket with new and new bolts. Test ran engine - all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 May 2021 Resolved
02108 - At a convenient location, a shore power connection box or receptacle shall be permanently installed and a cable connecting this box or receptacle to the main distribution panel shall be permanently installed. MI observed cable leading from the shore tie to the connection was attached with zip ties. - 46 CFR 183.10-50(a) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel representative installed metal hangers around shore tie cable that was being held by plastic zip ties - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 May 2021 Resolved
13199 - The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. MI observed missing flame screens on both the port and starboard fuel tanks. - 46 CFR 182.20-35(d) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel representative installed 30 x 30 mesh on both port and starboard goose neck vents for the fuel tanks - all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 May 2021 Resolved
13101 - Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. MI observed 02 air intakes missing closures. - 46 CFR 181.20-35 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel represenative install new vent covers with hinges and latches, verified operation and closure - all sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 May 2021 Resolved
02105 - All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. MI observed a hydraulic oil leak from the steering apparatus. - 46 CFR 182.30-1 - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel operator repair steering piping leak by installing new piping and valve - all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 19 May 2021 Resolved
09203 - Lighting fixtures shall be constructed in accordance with the requirements of Underwriters' Laboratories, Inc. Standard for Marine Type Electric Lighting Fixtures, Subject 595, or shall bear proper Underwriters' Laboratories, Inc. "Marine Type" label. MI observed 02 lighting fixtures missing protective covers/guards. - 46 CFR 183.10-20(l) - 16C
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2021
Resolved 17 June 2021
Resolution: Vessel representative installed new protective globes over existing lights that were missing - all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 May 2021 Resolved
03107 - For each watertight door, an indicator must be installed in the pilothouse and at each other vessel operating station from which the door is not visible. The indicator must show whether the door is open or closed. MI observed an unlabeled indicator light for a watertight door. - 46 CFR 170.270(e) - 10C
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Corrected on the Spot.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 May 2021 Resolved
10109 - All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. MI noted the stbd running light did not illuminate. - 46 CFR 183.420 - 10C
Action required: 10 - Deficiency Rectified
Resolved 19 May 2021
Resolution: Corrected on the Spot.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 1 September 2020 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Marine Inspector observed alteration to Potable Water tank. Plans had not been submitted or approved by OCMI. 46 CFR 176.700(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2020
Resolved 23 October 2020
Resolution: Received MSC memo stating that the vessel was under 2% weight displacement after calculations were conducted. Initial Lightship Value in 8/13/2018 was 96.47 LT and Revised Lightship Values - Weight Moment Calcs was 96.09 LT. Cleared def. all SAT
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 November 2016 Resolved
Vessel pre-engineered fire fighting system is empty. Refill and have inspected and serviced by a certified fire protection company prior to carrying passengers.
Condition: Improper Installation
Due 9 December 2016
Resolved 13 December 2016
Resolution: Vessel pre-engineered fire fighting system has been refilled, inspected and serviced by a certified fire protection company.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 29 November 2016 Resolved
Not servicable
Condition: Improper/Lack of Maintenance
Due 23 December 2016
Resolved 9 January 2017
Resolution: Confirmed vessel has onboard 169 Adult Type 1 PFD's and 17 Child PFD's.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 29 November 2016 Resolved
Does not have vessel name
Condition: Improper Installation
Due 23 December 2016
Resolved 9 January 2017
Resolution: confirmed vessel has onboard 169 Adult Type 1 PFD's and 17 Child PFD's. Life jackets will be marked with Vessels New Name after change of ownership and pior to obtaining COI
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 November 2016 Resolved
vessel Does not have approved permanent electrical wiring being utilized for lighting in Sewage space.
Condition: Improper Installation
Due 9 December 2016
Resolved 13 December 2016
Resolution: vessel has permanent approved electrical wiring being utilized for lighting in Sewage space.
Construction/Loadline
Issued 6 June 2000 Resolved
WELD FRACTURE ON AFT PADDLE WHEEL CROSS MEMBER.
Condition: Unknown
Due 6 July 2000
Resolved 20 June 2002
Engineering › Lubricating Oil Service System › Gauge
Issued 6 June 2000 Resolved
REPAIR ALL GAUGES IN THE WHEEL HOUSE.
Condition: Unknown
Due 6 July 2000
Resolved 2 August 2000
Accommodation/Occupational Safety
Issued 6 June 2000 Resolved
THROUGHLY CLEAN SECOND DECK BAR AREA.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 6 June 2000 Resolved
ENSURE ALL WIRING IS SUPPORTED EVERY 24" WITH METAL SUPPORTS AND ALL JUNCTION BOXES HAVE PROPER COVERS INSTALLED.
Condition: Unknown
Due 6 July 2000
Resolved 2 August 2000
Lifesaving › Visual Distress Signals (General) › Condition
Issued 6 June 2000 Resolved
CORRECT VOLUME PROBLEM ON PA SYSTEM SO IT MAY BE HEARD IN ALL AREAS.
Condition: Unknown
Due 6 July 2000
Resolved 2 August 2000
Engineering
Issued 6 June 2000 Resolved
CORRECT MINOR EXHAUST LEAKS IN AFT COMPARTMENT.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Documentation
Issued 6 June 2000 Resolved
PROVIDE CURRENT CERTIFICATE OF DOCUMENTATION FOR VESSEL.
Condition: Unknown
Due 20 June 2002
Resolved 6 June 2000
Electrical
Issued 6 June 2000 Resolved
INSTALL PROPER ELECTRICAL FITTINGS ON SHIP SERVICE GENERATORS WHERE WIRES EXIT THE GENERATOR CASING.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Construction/Loadline
Issued 6 June 2000 Resolved
PROVE PROPER OPERATION OF THE AFT COMPARTMENT PORT SIDE BILGE HIGH LEVEL ALARM.
Condition: Unknown
Due 23 August 2000
Resolved 23 August 2000
Construction/Loadline
Issued 6 June 2000 Resolved
SUBMIT REPAIR PROPOSALS FOR THE FOLLOWING: BOW DECK PLATE, REPLACEMENT OF BOW RAMP AND MAST WITH PE(PROFESSIONAL ENGINEER) CALC'S AND REPAIRS TO PADDLE WHEEL AREA AND PORT AND STARBOARD CAT WALK (LANDING AREA).
Condition: Unknown
Due 1 November 2000
Resolved 22 January 2003
Resolution: Items repaired as original while vessel was in yard.
Navigation
Issued 19 September 1999 Resolved
PROIR TO CARRYING PASSENGERS PROVE PROPER OPERATION OF VESSEL'S STEERING SYSTEM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 19 September 1999
Resolved 19 September 1999
Construction/Loadline
Issued 2 August 1999 Resolved
Clean bilges free of excess oil.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Engineering
Issued 2 August 1999 Resolved
Repair L/O (Lube oil) leaks on all engines.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Documentation
Issued 2 August 1999 Resolved
Provide list of items removed/installed since last inspection.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Electrical
Issued 2 August 1999 Resolved
Repair potable water pump.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Electrical
Issued 2 August 1999 Resolved
repair light fixture in engineroom.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Lifesaving
Issued 2 August 1999 Resolved
Prove proper training of entire marine crew on firefighting, abandon ship, man overboard and de-watering.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Engineering
Issued 2 August 1999 Resolved
Repair all exhaust leaks and install insulation per 46 CFR 116.970
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Electrical
Issued 2 August 1999 Resolved
Properly mount and wire battery switch.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Lifesaving
Issued 2 August 1999 Resolved
Remove all paint and flammable materials from spaces.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Construction/Loadline
Issued 2 August 1999 Resolved
Install check valves in all bilge suction lines.
Condition: Unknown
Due 2 August 1999
Resolved 2 August 1999
Engineering
Issued 8 April 1999 Resolved
Renew generator fuel hoses at the filter.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Documentation
Issued 8 April 1999 Resolved
Provide proof of vessel certificate of documentation (COD).
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Engineering
Issued 8 April 1999 Resolved
Repair lube oil leaks on the starboard generator.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Construction/Loadline
Issued 8 April 1999 Resolved
Prior to carrying passengers, ensure bilge suctions work in the forepeak,_x001C_ engineroom and fuel compartment._x001C_ _x001C_
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Accommodation/Occupational Safety
Issued 8 April 1999 Resolved
Properly mount water pumps in sewage space.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Navigation
Issued 8 April 1999 Resolved
Properly secure hydraulic hoses in steering space.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Construction/Loadline
Issued 8 April 1999 Resolved
Install high level bilge alarms, as per 46 CFR 119.530.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Electrical
Issued 8 April 1999 Resolved
Properly wire 12V DC system on bridge.
Condition: Unknown
Due 8 April 1999
Resolved 8 April 1999
Electrical
Issued 3 April 1998 Resolved
REPLACE MISSING GLOBES FOR LIGHTING.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Accommodation/Occupational Safety
Issued 3 April 1998 Resolved
REPLACE MISSING FIRE INSULATION IWO OVHD FWD STBD MDE.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Electrical
Issued 3 April 1998 Resolved
REPLACE ALL WIRE NUTS THROUGH-OUT VESSEL WITH PERMANENT CONNECTIONS.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 3 April 1998 Resolved
REPLACE DISTRESS SIGNALS FOR A TOTAL OF 6 NIGHT (RED) AND 6 DAY (ORANGE).
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Accommodation/Occupational Safety
Issued 3 April 1998 Resolved
REPLACE PORT FUEL VENT GOOSENECK.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Fire Fighting
Issued 3 April 1998 Resolved
PROVIDE PROOF OF ANNUAL SERVICING FOR PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Engineering
Issued 4 May 1994 Resolved
REPAIR WATER LEAK IN MANIFOLD, PORT MAIN ENGINE.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Lifesaving
Issued 4 May 1994 Resolved
REPLACE DEFECTIVE WATER LIGHT ON BUOYANT APPARATUS.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Engineering
Issued 4 May 1994 Resolved
CLEAN EXCESS OIL FROM BILGE IN ENGINE ROOM.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Electrical
Issued 18 March 1992 Resolved
REPAIR/RENEW STBD SSDG MUFFLER AND ASSOCIATED SPOOL PIECE FOR THRU HULL FITTING.
Condition: Unknown
Due 18 March 1992
Resolved 18 March 1992
Accommodation/Occupational Safety
Issued 1 November 1991 Resolved
PROVIDE 2ND EXIT FROM UPPER DECK AS PER 46 CFR 177.151.
Condition: Unknown
Due 1 November 1991
Resolved 1 November 1991
Construction/Loadline
Issued 3 July 1991 Resolved
INSTALL A WARNING LIGHT IN THE PILOT HOUSE THAT INDICATES WHETHER THE DOOR IN THE WATER TIGHT BULKHEAD BETWEEN THE ENGINE ROOM AND SHOP IS OPEN OR CLOSED. THIS REQUIREMENT IS TO BE COMPLETED TO THE SATISFACTION OF [name withheld] PRIOR TO 3 AUGUST 1991.
Condition: Unknown
Due 10 October 1991
Resolved 10 October 1991
Fire Fighting
Issued 27 November 1990 Resolved
PROVIDE 1 ADDITIONAL B-II FIRE EXTINGUISHER IN E/R PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Fire Fighting
Issued 27 November 1990 Resolved
REPLACE FIREHOSE NOZZLES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE MIN. 105 CAPACITY BOUYANT APPARATUS WITH PAINTERS, LIGHTS, AND STENCILLED VSL NAME AND CAPACITY PRIOR TO APPROVAL OF ROUTE BY OCMI.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Documentation
Issued 27 November 1990 Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE PRIOR TO OPERATING MORE THAN 1000' FROM LAND.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Documentation
Issued 27 November 1990 Resolved
PROVIDE COPY OF CARPET SPECIFICATIONS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
INSTALL/REWIRE AMMETERS TO SHOW ACTUAL LOAD ON P/S GEN'S.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROPERLY WIRE ALL E/R PUMPS WITH APPROVED CABLE - NO "50".
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Unknown
Issued 6 June 1990 Resolved
REMOVE ALL COMBUSTIBLES FROM BELOW DECK SPACES.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Construction/Loadline
Issued 6 June 1990 Resolved
PROVIDE 5 GPM HAND BILGE/FIRE PUMP.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Electrical
Issued 6 June 1990 Resolved
UPON COMPLETION OF REPAIRS TO PORT SHIP'S SERVICE GENERATOR CONDUCT AN OPERATIONAL TEST UNDER FULL LOAD CONDITIONS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Fire Fighting
Issued 6 June 1990 Resolved
PROVIDE APPROVED BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Lifesaving
Issued 6 June 1990 Resolved
PROPERLY LABEL ALL LIFE JACKET STOWAGE AREAS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Fire Fighting
Issued 6 June 1990 Resolved
SERVICE ALL ONBOARD FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Electrical
Issued 31 January 1990 Resolved
REMOVE ALL EXTENSION CORDS IN ENGINEROOM.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Accommodation/Occupational Safety
Issued 31 January 1990 Resolved
REPAIR 1 HEAD (2 OPERABLE) PRIOR TO 14FEB90. VESSEL IS LIMITED TO CARRYING49 PASSENGERS UNTIL 2 HEADS ARE OPERATIONAL.
Condition: Unknown
Due 31 January 1990
Resolved 31 January 1990
Documentation
Issued 28 April 1989 Resolved
PROVIDE VALID FCC LICENSE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 28 April 1989 Resolved
PROVIDE HAND PUMP(PUMP SHALL BE EQUIPPED FOR FIREFIGHTING AND OF SUFFICIENTLENGTH OF SUCTION HOSE FOR BILGE SUCTION).
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
REPAIR STB GENERATOR VOLTAGE REGULATOR.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Navigation
Issued 28 April 1989 Resolved
PROVIDE 2 ORANGE AND 2 RED DISTRESS FLARES.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 28 June 1988 Resolved
YOU ARE DIRECTED TO REMOVE ALL CEILING TILES WHICH ARE NOT COAST GUARD APPROVED (REQUIREMENT PREVIOUSLY ISSUED TO PROVIDE EVIDENCE OF APPROVAL WASNOT COMPLIED WITH PRIOR TO COMPLIANCE DATE OF 07JUN88).
Condition: Unknown
Due 28 June 1988
Resolved 28 June 1988
Accommodation/Occupational Safety
Issued 7 May 1988 Resolved
CORRECT LABELING TO WATERTIGHT DOOR.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Construction/Loadline
Issued 7 May 1988 Resolved
ADJUST WATERTIGHT DOOR IN ENGINE ROOM AND CHALK TEST.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Fire Fighting
Issued 7 May 1988 Resolved
MOUNT FIRE EXT. IN AUXILARY ENGINE ROOM SPACE.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Accommodation/Occupational Safety
Issued 7 May 1988 Resolved
REMOVE LOCKING DEVICE FROM FWD ENGINE ROOM SPACE WATERTIGHT DOOR (FIRE ESCAPE).
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Documentation
Issued 7 May 1988 Resolved
OVERALL LENGTH OF VESSEL WAS MEASURED 79' 4'' OVER DECK; PLEASE PROVIDE COMMENT.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Lifesaving
Issued 7 May 1988 Resolved
PROVIDE MEANS TO STOW CHILD LIFE JACKETS SEPARATELY (IF PRACTICABLE LIFE PRESERVER CONTAINERS SHALL BE DESIGNED TO FLOAT FREE).
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Accommodation/Occupational Safety
Issued 7 May 1988 Resolved
REMOVE DEBRIS FROM ENGINE ROOM (MISC. ITEMS).
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Electrical
Issued 7 May 1988 Resolved
PROVIDES GUARDS AND COVERS FOR ENGINE ROOM LIGHTS.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Electrical
Issued 7 May 1988 Resolved
REMOVE ALL ELECTRICAL CABLE WHICH IS NOT SUITABLE FOR MARINE USE (SEE 46CFR183.10-20).
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Construction/Loadline
Issued 7 May 1988 Resolved
PLUG ALL THRU HOLE FITTING WHICH ARE NOT WATERTIGHT (MACHINERY SPACE AFT BEHIND PORT GENERATOR).
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Accommodation/Occupational Safety
Issued 7 May 1988 Resolved
INSTALL DECK COVERINGS IN ENGINE ROOM.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Accommodation/Occupational Safety
Issued 7 May 1988 Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Electrical
Issued 7 May 1988 Resolved
REPLACE GENERATOR CONTROL KNOBS (HELD TOGETHER WITH BLACK TAPE).
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Accommodation/Occupational Safety
Issued 7 May 1988 Resolved
PROVIDE EVIDENCE THAT CEILING TILES ARE COAST GUARD APPROVED.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Fire Fighting
Issued 7 May 1988 Resolved
REPAIR OR REPLACE A-60 INSTALLATION IN ENGINE ROOM
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Fire Fighting
Issued 7 May 1988 Resolved
REPAIR SECOND DECK FIRE DOOR.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Electrical
Issued 7 May 1988 Resolved
REPAIR WIRING TO PORT AIR CONDITIONING PUMP.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Lifesaving
Issued 7 May 1988 Resolved
PROVIDE ADEQUATE LIGHTING TO, AND MARK ENGINE ROOM ESCAPE.
Condition: Unknown
Due 7 May 1988
Resolved 7 May 1988
Documentation
Issued 11 February 1988 Resolved
POST POLLUTION PREVENTION PLACARD IN FUEL HANDLING SPACES.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Engineering
Issued 11 February 1988 Resolved
INSTALL CAP OR PLUG ON VALVE AT TOP OF FUEL TANK.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Construction/Loadline
Issued 11 February 1988 Resolved
INSTALL CAPTIVE CHAINS OR DEVICES ON MAIN DECK WATERTIGHT HATCHES TO PREVENT THEIR LOSS.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Lifesaving
Issued 11 February 1988 Resolved
PROVIDE 6 RED HAND FLARE AND 6 ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Accommodation/Occupational Safety
Issued 11 February 1988 Resolved
INSTALL GUARD RAIL 6 INCHES HIGH AROUND GALLEY STOVE-TOP.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Construction/Loadline
Issued 11 February 1988 Resolved
LABEL BOTH SIDES OF WATERTIGHT DOOR WITH WORDS "WATERTIGHT DOOR--CLOSE IN EMERGENCY" IN 1 INCH LETTERS.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Lifesaving
Issued 11 February 1988 Resolved
RE-NEW SAFETY LINE ON RING BUOY.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988
Electrical
Issued 11 February 1988 Resolved
PERMANENTLY INSTALL SWITCH FOR COFFERDAM PUMP.
Condition: Unknown
Due 11 February 1988
Resolved 11 February 1988

Casualty record · 1

12 July 2025Routine · role: Involved in a Marine Casualty · activity 8190920
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.