← All vessels
SERIFE
SERIFE is a 1984 freight ship. The Coast Guard has recorded 30 inspections since 1984, most recently in March 2009, along with 36 deficiencies and 2 operational controls.
Records from 1984 to 2009. Most recent: inspection, 18 March 2009.
- Built
- 1984
- Last inspected
- 18 March 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 36 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8307569 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9HQR7
245850
Flag
MALTA
—
Maury page id
psix-245850
Inspections, by type
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it11015 - Dead Weight, Ton
41544 - Displacement, Ton
24643 - Regulatory (Subpart C or D), Gross Ton
24643 - Convention (Subpart B), Gross Ton
13377 - Regulatory (Subpart C or D), Net Ton
41544 - Displacement, Ton
24643 - Regulatory (Subpart C or D), Gross Ton
24643 - Convention (Subpart B), Gross Ton
13377 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
18 March 2009
ISPS III Exam · PII Safety Exam · Ballast Water Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3435520
19 May 2008
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3200809
23 March 2005
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2317586
4 December 2004
ISPS II Exam · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2253217
4 December 2004
Ballast Water Examination · PII Safety Exam
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2253223
17 January 2003
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1732634
18 July 2002
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1648147
7 April 2002
MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1599800
26 June 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291341
10 September 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 281877
26 January 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 424943
25 February 1998
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 413249
16 June 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 404697
27 September 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 395795
16 June 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392229
10 November 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 710385
31 October 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 384446
16 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 378493
26 October 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 684955
22 October 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 456208
16 October 1992
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 353759
6 May 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 458434
30 October 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 346759
7 August 1990
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 338531
29 December 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 334398
30 November 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 327031
11 February 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 447309
4 September 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 318255
22 June 1986
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 309500
3 December 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 300522
Deficiency record · 36
Construction/Loadline › Structures › Manhole
Issued 18 March 2009
Resolved
1282: Manhole covers to topside tanks #4 on both port and starboard and topside tank # 1 starboard have water seeping through from the ballast tanks; this puts the watertight integrity of the covers into question. Deficiency must be rectified by class prior to departure. 17a/b
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 March 2009
Resolved
1110: Hydraulic leaks were found on numerous cargo hatch cylinders and cargo control valves posing both a pollution hazard and a safety hazard for the crew. 17a/b
Construction/Loadline › Structures › Air Pipe
Issued 18 March 2009
Resolved
1275: Sewage is being pumped into the #3 topside tank starboard side from the engine room by a flexible hose. 17a/b
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 18 March 2009
Resolved
0710: The following deficiencies were found regarding fire prevention: a) the structural fire boundaries regarding class A and B fire doors throughout the vessel are not reflected on the Fire Control Plan. b) Holdback hooks were found on numerous self closing fire doors, including door entrance into steering gear room. c) Penetrations were found in the bulkheads around the galley and ECR. 17a/b
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 18 March 2009
Resolved
1240: Numerous dogs to watertight and weather tight hatches were missing throughout the vessel. Class to attest that all dogs are in place and hatches can be securely closed to prevent water from entering. 17a/b
Engineering › Diesel Engine (auxiliary) › Piping (air intake)
Issued 18 March 2009
Resolved
1400: The following deficiencies were found in the engine room: a) main engine scavenger air cooler, salt water supply and discharge valves are missing valve controllers. b) auxiliary generator salt water cooling pump discharge valve is leaking continuously into the bilge. c) auxiliary freshwater cooler #2 pip is pitted and leaking. d) main engine scavenger air pipe is leaking. 17a/b
Stability › Watertight Integrity › General
Issued 18 March 2009
Resolved
1270: Weather tight and watertight doors leading to outer deck from accommodation spaces on upper bridge deck will not close completely. In addition, watertight doors in bosuns store does not close completely when secured and the escape door between the galley and weather deck is not watertight. Doors must be addressed by class. 70a/b
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 18 March 2009
Resolved
0695: Training Manuals for fire fighting does not include general instructions for fire fighting activities and procedures In addition, the lifesaving training manual does not reflect proper donning information for immersion suits and does not indicate that the vessel has enough immersion suits onboard for the crew and does not show the correct type of immersion suits onboard. Class must address.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 18 March 2009
Resolved
0950: Numerous high voltage panels in the machinery spaces and bosun hold are missing non-conductive matting. 70a/b
Deck/Cargo › Mooring/Anchoring › Winch
Issued 18 March 2009
Resolved
1330: Hydraulic power units #1 and #2 for the forward mooring winches are leaking hydraulic oil which is polling within the containment. Items must be addressed by class. 70a/b
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 18 March 2009
Resolved
0330: Marine Sanitation Device is holed and patched with fiberglass on the tank side and top in the area of the chlorine tablets tube. Item must be addressed by class.
Operations/Management › Ballast Water Managment › Sediments
Issued 18 March 2009
Resolved
2055: The ballast water handling log provided in the BWM Plan is not being used and an up to date record of sediment is not being kept. In addition, the capacity of tanks reported on the ballast reporting form dated 3/17/09 does not match the capacity of tanks listed on the BWM Plan.
Construction/Loadline › Hull › Hull Plating
Issued 17 January 2003
Resolved
INSETS SPANNING 4 FRAME BAYA AND EXTENDING VERTICALLY APPROX 3 FT IN THE VICINITY OF THE STBD SIDE LOADLINE. PROVIDE CLASS REPORT.
Construction/Loadline › Structures › Deck Plating
Issued 17 January 2003
Resolved
TWO HOLES IN MAIN DECK. 1 HOLE WAS APPROX 1-2CM IN DIAMETER ON STBD SIDE APPROX 1 FT FROM THE MIDDLE OF CARGO HOLD #1. 1 HOLE WAS APPROX 1-2CM IN DIAMETER ON PORT SIDE, ALSO NEAR MIDDLE OF CARGO HOLD #1. PROVIDE CLASS REPORT.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 17 January 2003
Resolved
FLAME SCREENS MISSING ON HFO FUEL TANK VENTS ON MAIN DECK
Lifesaving › Inflatable Liferafts
Issued 7 April 2002
Resolved
STBD Liferafts missing banding straps. FWD Liferaft missing banding straps. Ensure proper servicing of these liferafts in accordance with manufacturers instructions. SOLAS 74 III/15 LEGACY COMPONENT DESC: Container Construction
Lifesaving › Lifejacket/PFD (General)
Issued 7 April 2002
Resolved
Several lifejacket lights expired. Provide replacement lights for all expired lights. SOLAS 74 AMD III/7 LEGACY COMPONENT DESC: Lights
Communications › Radio Communications
Issued 7 April 2002
Resolved
EPIRB was tied down and hydrostatic release container cracked. Replace EPIRB container and hydrostatic release pin assembly in accordance with manufactures specifications. SOLAS 74 AMD IV/7.1.6 LEGACY COMPONENT DESC: EPIRB
Fire Fighting › Structural - A Class Divisions
Issued 7 April 2002
Resolved
Fire door between machinery space and steering gear room non self closing. Make self closing as required by SOLAS 74 II-2/51. LEGACY COMPONENT DESC: Openings - Fire Doors
Operations/Management › Pollution
Issued 7 April 2002
Resolved
Incinerator ignitor missing or inoperative. Make as original in accordance with manufactures specifications. LEGACY COMPONENT DESC: Control of Garbage
Fire Fighting › Firemans Outfit
Issued 7 April 2002
Resolved
Firemans outfit headgear does not provide sufficient protection from steam burns or scalding. Replace this headgear with one similar to the other ship fire suit headgear. LEGACY COMPONENT DESC: Protective Clothing
Fire Fighting
Issued 16 June 1997
Resolved
Renew as original all deteriorated firemain piping where leaking and where doubler plates have been installed on the starboard side of cargo holds #1,#2, and #3._x001C_ See SOLAS 74 (Amended) II-2/21_x001C_
Navigation
Issued 27 September 1996
Resolved
Vessels gyro was inoperative and eventually repaired.
Fire Fighting
Issued 16 June 1996
Resolved
Obtain class approval for the temporary adjustments to the crossover line for the fire main, or make permanent repairs as required, prior to port departure. _x001C_ Solas 74 amd, II-2/4.41
Deck/Cargo
Issued 16 June 1996
Resolved
Correct the leaking hatch cover rams for the following: #1 hold P & S, fwd,P, aft; #2 S aft, P & S fwd; #4 hold P aft; #5 P & S, aft & fwd._x001C_ _x001C_ 33 CFR 151.10
Lifesaving
Issued 16 June 1996
Resolved
Repair/replace the wasted cover securing devices for the provisions storagecompartments in both lifeboats._x001C_ Solas 74 amd, III/7.5
Construction/Loadline
Issued 16 June 1996
Resolved
Renew the faded loadline markings, prior to the next U.S. port call._x001C_ _x001C_ ICLL, I/5
Lifesaving
Issued 16 June 1996
Resolved
Obtain class approval for the present condition of the fuel tank for the starboard lifeboat, prior to the next U. S. port call. The tank shows signs of heavy rust buildup, but no leakage is evident. _x001C_ Solas 74 amd, III/41.6
Lifesaving
Issued 31 October 1995
Resolved
THE ENGINE ON THE LIFEBOAT WOULD NOT START. CREWMEMBERS ATTEMPTED TO STARTTHE LIFEBOAT FOR 20 MINUTES WITHOUT SUCCESS. VESSEL REQUIRED TO REPAIR PRIOR TO DEPARTURE.
Navigation
Issued 16 October 1992
Resolved
US COAST PILOT WAS NOT UPDATED.
Navigation
Issued 16 October 1992
Resolved
THE US COAST GUARD LIGHT LIST WAS OUT OF DATE
Documentation
Issued 16 October 1992
Resolved
VESSEL HAD EXPIRED IOPP CERTIFICATE ON BOARD
Documentation
Issued 16 October 1992
Resolved
THERE WAS NO VALID LOADLINE CERTIFICATE ON BOARD THE VESSEL
Navigation
Issued 16 October 1992
Resolved
WHILE CONDUCTING ANNUAL EXAMINATION, BOARDING OFFICER FOUND THAT CHART #11523 WAS NOT CURRENTLY CORRECTED AND CHART #11524 WAS NOT ON BOARD.
Accommodation/Occupational Safety
Issued 29 December 1989
Resolved
TYPE II MARINE SANITATION DEVICE NOT OPERATING PROPERLY.
Navigation
Issued 4 September 1987
Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO ASTORIA, OREGON WITHOUT HAVING ON BOARD A COPY OF THE INLAND NAVIGATION RULES.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.