Records from 2001 to 2026. Most recent: inspection, 29 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
29 April 2026
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8359008
24 February 2026
Internal Structural Exam · In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8315333
30 April 2025
Internal Structural Exam · Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8126411
29 March 2025
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8104868
6 February 2025
Administrative Inspection
Administrative · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8069708
10 December 2024
Construction Oversight
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8046428
16 January 2024
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7846632
18 April 2023
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7670555
15 June 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7479941
20 January 2022
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7382801
26 May 2021
Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7200482
22 April 2021
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7199407
3 November 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7101623
1 April 2020
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6933891
23 February 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 6928327
20 May 2019
Administrative Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6688807
23 April 2018
Administrative Inspection · DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6397955
19 May 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6156354
11 May 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6153853
28 February 2017
Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6069016
21 March 2016
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5838573
11 May 2014
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 4862835
16 February 2012
COI Inspection · Internal Structural Exam · Hull Examination · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4246001
24 April 2009
Annual Inspection · Internal Structural Exam · Hull Examination · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3459327
9 April 2008
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3180718
7 March 2007
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2959820
10 April 2006
Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2830133
25 April 2005
Hull Examination · Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2517872
5 July 2004
Type not recorded
No type recorded · USCGC KISKA (WPB 1336) · USCG Oceania District (CGD-O) · Activity 2147481
25 May 2004
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2088001
23 April 2004
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2087894
10 March 2003
Annual Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1757018
6 March 2003
Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1753654
6 February 2002
Deficiency Check · Hull Examination · Initial Certification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1486188
29 March 2001
Plan Review "T" Boat · Initial Construction-Excluding Oversight
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1366341
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 July 2026
No resolution recorded
Vessel issued CG 835 on 31MAR2026 for the following:
-submit repair proposal to address all wastage in transverse frame spaces #04.
-conduct necessary repairs in accordance with approved repair proposal.
To this date, none of the CG835 requirements have been met to the satisfaction of USCG. Vessel is restricted from carrying passengers until above listed requirements have been completed and met to satisfaction of USCG.
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2026
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel operators must provide proof of annual maintenance for portable fire extinguishers. Corrected on the spot
Action required: 10 - Deficiency Rectified
Resolved 29 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 29 April 2026
Resolved
Vessels on limited coastwise routes are required to carry six (06) red and six (06) orange flares or twelve (12) red flares. Vessel had nine (09) red flares at the time of the inspection. Must add three (03) more flares for vessel's route. Corrected on the spot
Action required: 10 - Deficiency Rectified
Resolved 29 April 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 April 2026
Resolved
Approved water light for required ring buoy not operational at time of inspection. Vessel is restricted to daylight operations until deficiency is rectified to satisfaction of USCG.
Action required: 705 - Other - as specified
Resolved 9 May 2026
Resolution: daylight restricted
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 April 2026
Resolved
Hydrostatic release for EPIRB not properly connected at time of inspection. Must reinstall or replace to allow EPIRB to automatically float free to satisfaction of USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 9 May 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2026
Resolved
Must install proper label, block letters at least 2" on contrasting colors, on stowage bin with lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 9 May 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2026
Resolved
Remote fuel shut-off stations must be marked in clearly legible letters at least 1" high indicating purpose of valve and direction of operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2026
Resolved 9 May 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 February 2026
Resolved
USCG received notification from state agency concerning possible damage on the vessel collar creating a hazardous condition for vessel crew and passengers. Vessel is not permitted to get underway with passengers until USCG Marine Inspectors can verify/conduct damage assessment, determine repair proposal and repairs are made to satisfaction of USCG.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2026
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 February 2026
Resolved
Conducted internal hull assessment at operator's request. Spot gauged six (06) isolated pits in the hull at the waterline located in the starboard quarter section of the vessel. Vessel is required to haul out in thirty (30) days for full assessment and formulate repair plan/time frame.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2026
Resolved 31 March 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2025
Resolved
A vessel not required to have a power-driven fire pump by § 181.300 must have at least three (03) 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel only had 00 fire buckets at time of inspection. Corrected
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2025
Resolved
It was determined that vessel is required to have the following portable extinguishers IAW their COI:
-One (01) 10 B:C extinguisher at operating station
-One (01) 40 B:C extinguisher for outboard engines
Vessel had two (02) 10 B:C extinguisher at time of inspection and must replace/add one (01) 40 B:C extinguisher. Corrected
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 April 2025
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel operators must provide proof of annual maintenance for portable fire extinguishers to USCG. Corrected; operator purchased new extinguishers and provided receipts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: provide services necessary for safety, protect passengers, crew and other persons from electrical hazards and prevent electrical ignition of flammable vapors. Observed the following during inspection:
-improper wiring for navigation lights and electric bilge pump. Conduits were wired from negative terminals on 12V battery directly to load sources. No over current protection and central electrical distribution.
-Wiring for navigational lights improperly spliced before connection to load sources.
Must install all electrical equipment onboard in accordance with approved vessel electrical plan.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 16 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2025
Resolved
All flexible nonmetallic hose for use in vital systems must meet specifications in SAE J1942 or SAE J1527 (no more than 30 inches in section length). There is no evidence that the current, flexible fuel lines meet these specifications. Must replace to satisfaction of USCG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 13 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 30 April 2025
Resolved
All electrical bilge pumps must meet the requirements of UL 1113. No evidence that current electric bilge pump meets these requirements. Must remove electric bilge pump and all associated wiring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect crew, other persons and the vessel from electrical hazards. Need to remove or cap dead end wire underneath operator's station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 April 2025
Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. Vessel has expired Radio Safety Certificate. Must correct to the satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2025
Resolved 1 May 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 April 2025
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolution: Personnel not allowed to serve as crewmembers until proof of DAPI enrollment. Note: Vessel operator provided updated list with [name withheld] but not [name withheld].
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2025
Resolved
Must change vessel name on the following lifesaving equipment:
-All lifejackets
-Life buoy
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2025
Resolved
Remote fuel shut-off stations must be marked in clearly legible letters at 1 inch high. Shut-off station in forward stowage bin must be marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2025
Resolved 14 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 January 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the Operation of the main propulsion machinery both ahead and astern. Port engine had Hi-Temp alarm and STBD engine has excess vibration.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2022
Resolved 1 February 2022
Resolution: Both engines serviced by authorized servicing dealer and tested satisfactorily during the sea trial.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 January 2022
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Both port and STBD shutoff valves were not operable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 February 2022
Resolved 1 February 2022
Resolution: Fuel shutoff valves renewed and operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 January 2022
Resolved
Ring life buoy must be marked with Type II retroreflective material. Missing retroreflective tape.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2022
Resolved 1 February 2022
Resolution: Retroreflective tapes on the ring buoy.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 January 2022
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. No installation bracket and no labeling.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 February 2022
Resolved 1 February 2022
Resolution: Portable fire extinguisher properly mounted with "FIRE EXTINGUISHER" sign.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 January 2022
Resolved
Name of the vessel must be marked or painted in clearly legible letters on each Emergency Position Indicating Radio Beacon (EPIRB). No name on the EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2022
Resolved 1 February 2022
Resolution: EPIRB properly marked with vsl name.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 20 January 2022
Resolved
Every vessel must be fitted with a suitable magnetic compass designed for marine use, to be mounted at the primary operating station. Steering compass is not readable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2022
Resolved 1 February 2022
Resolution: New illuminated compass installed and tested sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 May 2021
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a FCC Safety Radiotelephony Certificate. The vessels Safety Radio certificate is expired. Complete an inspection of the radio installation by a FCC-licensed technician.
47CFR80.903
Action required: 705 - Other - as specified
Resolved 20 July 2021
Resolution: Provided certificate.
Fire Fighting › Remote Fuel Shutoff › General
Issued 9 April 2008
Resolved
Found remote fuel shutoff system to be inadequate. Fuel shutoff at the tank connection is within a space where the reach is greater than 12 in. Fix remote fuel shutoff system i.a.w. 46 CFR 182.455(b)(4).
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 29 April 2008
Documentation › Certificates/Documents › FCC SSL
Issued 7 March 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 7 April 2007
Resolved 14 March 2007
Stability › Intact Righting Energy › General
Issued 7 March 2007
Resolved
Prove ability of stbd fwd tube to hold pressure for ten minutes
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 April 2006
Resolved
Conduct drills with 100% of crew and log appropriately
Due 10 June 2006
Resolved 9 June 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 April 2006
Resolved
Obtain new first aid kit
Due 10 June 2006
Resolved 9 June 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 April 2006
Resolved
Have tides & currents and coast pilot onboard vessel
Due 10 June 2006
Resolved 9 June 2006
Operations/Management › Equipment Service/Testing › EPIRB
Issued 25 April 2005
Resolved
Log Monthly EPIRB testing.
Due 25 May 2005
Resolved 2 June 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 April 2005
Resolved
Prove proper servicing of B-I fire extinguisher.
Due 25 May 2005
Resolved 2 June 2005
Documentation › Certificates/Documents
Issued 23 April 2004
Resolved
Renew FCC Radio Safety Certificate NLT 23 May 2004 LEGACY COMPONENT DESC: FCC SSL
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Operations/Management › Drug and Alcohol Testing
Issued 23 April 2004
Resolved
Submit MIS form to USCG HQ for calandar year 2003, NLT 23 May 2004. LEGACY COMPONENT DESC: MIS Submission
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Communications › Radio Communications
Issued 23 April 2004
Resolved
Provide evidence that EPIRB is properly registered with NOAA NLT 23 May 2004 LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 23 May 2004
Resolved 25 May 2004
Navigation › Collision/Grounding Avoidance
Issued 12 March 2002
Resolved
Relocate the port & stbd sidelights so that both sidelights are always visible in accordance with rule 22 of the Navigation Rules. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2002
Resolved 6 March 2003
Resolution: CID felt that the vessel''s captains are responsible for keeping passengers out of the way of the navigation lights, cleared requirement.
Engineering › Bilge Water Management System
Issued 12 March 2002
Resolved
Install a suitable strainer in the bilge suction line that has an open area of not less than three times the area of the bilge pipe in accordance with 46 CFR 182.510(b) LEGACY COMPONENT DESC: Strainer
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2002
Resolved 13 August 2002
Engineering › Fuel Oil Service System
Issued 12 March 2002
Resolved
Install a flammable vapor detection system in the fuel tank space in accordance with 46 CFR 182.480
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2002
Resolved 13 August 2002
Resolution: CID allowed an alternative arrangement, the vessel drilled holes in the plating covering the fuel tank to allow ventilation of the fuel tank space.
Engineering › Fuel Oil Service System
Issued 12 March 2002
Resolved
Renew all fuel hoses with hoses that meet SAE standard J-1942. In addition, all hoses must be complete with hose end fittings that meet SAE standard J-1475 in accordance with 182.720(e). The current configuration is in accordance with 182.455(c) and as such the vessel is limited to 12 passengers. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 May 2002
Resolved 6 March 2003
Resolution: Cleared requirement based on activity 1753654.