MAURY USCG vessel records Sign in
← All vessels

DD FIDELITY

DD FIDELITY is a 1984 freight ship. The Coast Guard has recorded 26 inspections since 1985, most recently in May 2007, along with 16 deficiencies and 3 operational controls.

Records from 1985 to 2007. Most recent: inspection, 28 May 2007.

Built
1984
Last inspected
28 May 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8413954 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B3086
246084
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-246084

Inspections, by type

…with no type recorded23
Years with a record 15 calendar years (1985–2007)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it23508 - Dead Weight, Ton
28863 - Displacement, Ton
13852 - Convention (Subpart B), Gross Ton
8134 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 26

28 May 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2943760
15 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2241625
8 July 2004 NPV Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2125800
7 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2124355
2 July 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2119473
11 January 1999 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 424480
30 January 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 206405
30 January 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 399949
30 January 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 766017
9 August 1996 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 394076
24 January 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 386653
16 November 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 158889
19 May 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 366962
19 May 1994 Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 859586
29 January 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 494096
14 October 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 487063
12 December 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347759
6 August 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 338632
29 June 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 331222
14 June 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 323799
22 October 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 319172
8 June 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 316635
26 January 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313963
10 November 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 498625
27 March 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 307607
19 February 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 300371

Deficiency record · 16

Construction/Loadline
Issued 24 January 1996 Resolved
Prove proper operation of the bilge pump for the emergency fire pump space (standing water in the space currently cannot be drained), prior to the port departure._x001C_ Solas Ch II-1, Reg 21
Condition: Unknown
Due 25 January 1996
Resolved 25 January 1996
Electrical
Issued 24 January 1996 Resolved
Reconnect the grounding wire on the explosion proof lighting fixture in thepaint locker, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 45.10
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Fire Fighting
Issued 24 January 1996 Resolved
Correct the leaking coupling on the fire main at the #2 cargo hold, stbd side, prior to port departure._x001C_ _x001C_ Solas Ch II-2, Reg 2
Condition: Unknown
Due 25 January 1996
Resolved 25 January 1996
Fire Fighting
Issued 24 January 1996 Resolved
Adjust the self-closing devices on the fire door for the emergency steeringcompartment and the engine room from the main deck to allow for complete closure, prior to the next U.S. port call._x001C_ Solas Ch II-2, Reg 47
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Navigation
Issued 24 January 1996 Resolved
Provide non-skid surface or grating for the emergency steering gear area, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-2, Reg 29.13.2
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Lifesaving
Issued 24 January 1996 Resolved
Remove the temporary hose used to drain oil from the cylinder heads to the bilge, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 26
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Electrical
Issued 24 January 1996 Resolved
Identify and correct the ground in the 100 V feeder panel, prior to the next U. S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 40
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Electrical
Issued 24 January 1996 Resolved
Properly install the temporary lights located at the M/E lubricator unit and the M/E F/O heater, prior to the next U.S. port call._x001C_ _x001C_ Solas Ch II-1, Reg 40
Condition: Unknown
Due 9 August 1996
Resolved 9 August 1996
Documentation
Issued 19 May 1994 Resolved
PRIOR TO DEPARTURE, PROVIDE LICESNED CAPTAIN ON BOARD, ENSURE REQUIREMENTS FOR MINIMUM CREW ARE MET AS PER VESSELS MINIMUM SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 21 May 1994
Resolved 27 May 1994
Navigation
Issued 19 May 1994 Resolved
INSTALL LOW LEVEL ALARM FOR STEERING GEAR HYDRAULIC FLUID SYSTEM ON BRIDGE.PROVIDE SATISFACTORY CLASS SOCIETY SURVEYOR REPORT ATTESTING TO SATISFACTORY INSTALLATION AND OPERATION, TO U.S. COAST GUARD AT NEXT U.S. VOYAGE OR 19 NOV 94, WHICHEVER OCCURS FIRST.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Documentation
Issued 29 June 1989 Resolved
VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN A DESCRIPTION OF AND PROCEDURES FOR EMPTYING THE DISCHARGE CONTAINMENT SYSTEM AS REQUIRED BY 33 CFR 155.750(A)(2)(III).
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Navigation
Issued 29 June 1989 Resolved
VESSEL TRANSITED PUGET SOUND WATERS UTILIZING CHARTS NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33CFR164.33(A)(1)(II) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS WITH 33CFR 164.33 (B).
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Documentation
Issued 29 June 1989 Resolved
VESSEL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN THE PROCEDURES FOR OPERATING THE MEANS OF COMMUNICATIONS AS REQUIRED BY 33 CFR 155.750(A)(6).
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Navigation
Issued 14 June 1988 Resolved
BOARDED SUBJECT VESSEL AT APPROX. 1400LCL, 14JUN88, AT WRANGELL, AK., AND FOUND THAT THE VESSEL DID NOT HAVE SIMPLE OPERATING INSTRUCTIONS WITH A BLOCK DIAGRAM SHOWING PROCEDURES FOR REMOTE STEERING GEAR CONTROL SYSTEMS AND POWER UNITS PERMANENTLY POSTED ON THE NAVIGATION BRIDGE.
Condition: Unknown
Due 17 June 1988
Resolved 14 June 1988
Navigation
Issued 8 June 1987 Resolved
NO TIDLE CURRENT TABLE ON VESSEL AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987
Navigation
Issued 27 March 1986 Resolved
VESSEL'S MARINE NAVIGATION CHARTS OF THE AREA WERE MISSING THE FOLLOWING CORRECTIONS FROM NOTICES TO MARINERS: 18521, 10 FROM 1985; 18523, 14 FROM 1985; 18524, 14 FROM 1985; 18526, 3 FROM 1985.
Condition: Unknown
Due 27 March 1986
Resolved 27 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.