MAURY USCG vessel records Sign in
← All vessels

CHEREMKHOVO

CHEREMKHOVO is a 1984 freight ship. The Coast Guard has recorded 40 inspections since 1985, most recently in February 2008, along with 57 deficiencies and 6 operational controls.

Records from 1985 to 2008. Most recent: inspection, 26 February 2008.

Built
1984
Last inspected
26 February 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8306541 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
246330
Flag
SOVIET UNION
—
Maury page id
psix-246330

Inspections, by type

…with no type recorded32
Years with a record 13 calendar years (1985–2008)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it23242 - Dead Weight, Ton
31307 - Displacement, Ton
16794 - Convention (Subpart B), Gross Ton
8843 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

26 February 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3153892
5 February 2008 STCW 95 Exam · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · Loadline Exam · Annual Inspection · ISM Exam · ILO-147 Exam · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3142013
25 September 2006 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2786563
5 September 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2769086
15 February 2006 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2585935
1 February 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2577424
30 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2576012
27 January 2006 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574433
2 August 2005 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2448715
23 June 2005 Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS III Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2399451
16 June 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2393271
13 June 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2404876
24 March 2005 MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2318298
24 March 2005 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2318384
8 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2256001
1 December 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2257665
21 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2261113
19 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2223638
8 October 2004 NPV Safety Exam · Ballast Water Examination · ISPS II Exam · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2216122
7 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2224961
4 December 2003 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1959780
23 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 669440
16 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 74414
16 November 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 434742
9 November 1999 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 434880
28 April 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 669441
18 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426646
17 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 42272
24 September 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 420760
8 September 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 420054
19 February 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413001
21 June 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 392384
24 May 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 391447
9 April 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 377119
23 January 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 334855
13 April 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 322804
23 June 1986 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 473083
26 March 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 307843
25 November 1985 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 472594
19 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 300774

Deficiency record · 57

Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 5 February 2008 Resolved
Emergency egress alarm for refrigeration flats was inoperable.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 February 2008
Resolution: Electrician corrected deficiency while PSC team was still on-board.
Engineering › Steering Gear System › Pump
Issued 2 August 2005 Resolved
Failure of step-down transformer of control circuit of magnetic amplifier on power unit No. 2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2005
Resolution: Newly installed transformer, type 730.9602-010001 Sp2. Steering gear system was satisfactorily tested.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 24 March 2005 Resolved
No lifejackets located in the forecastle area. Provide six (6) lifejackets for this location as per the Ship Safety Equipment Certificate Form E, prior to departing COTP NY.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2005
Resolved 24 March 2005
Resolution: Six lifejackets placed in forecastle.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 24 March 2005 Resolved
Door from emergency escape in engine room, door 903, will not close completely. Make proper adjustments to door, providing self-closure, prior to departing COTP NY.
Action required: 17 - Rectify deficiencies prior to departure
Due 24 March 2005
Resolved 24 March 2005
Resolution: Door was adjusted to close properly.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 March 2005 Resolved
Aft starboard railing located on the poopdeck is holed/wasted. Make permanent repairs, to the satisfaction of Class, by 24 APR 05.
Action required: 705 - Other - as specified
Due 24 April 2005
Resolved 23 June 2005
Resolution: During boarding CGMI received class report from RMS satisfying requirement.
Fire Fighting › Structural - B Class Divisions › Control Stations
Issued 24 March 2005 Resolved
B Class ceiling in CO2 room is loose and hanging near entrance to the space. Repair ceiling, to the satisfaction of Class, by 24 APR 05
Action required: 705 - Other - as specified
Due 24 April 2005
Resolved 23 June 2005
Resolution: During boarding CGMI received class report from RMS satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 24 March 2005 Resolved
MSD is holed on top of tank. Make permanent repairs, to the satisfaction of Class, by 24 APR 05.
Action required: 705 - Other - as specified
Due 24 April 2005
Resolved 23 June 2005
Resolution: During boarding CGMI received class report from RMS satisfying requirement.
Electrical
Issued 16 November 1999 Resolved
Emergency Generator to be working properly prior to departure from anchorage.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Construction/Loadline › Structures › Ventilators
Issued 16 November 1999 Resolved
Vents on upper decks of wheel-house need new gaskets. Repair prior to Next US Port to the satisfaction of Class. Provide report to US Coast Guard in writting.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Resolution: During the course of the inspection, boarding team noted that these deficiencies were corrected.
Construction/Loadline
Issued 16 November 1999 Resolved
Vessel found to have conducted a ballast exchange that was not in accordance with 33CFR151.1510, and did not properly request US Coast Guard approval for an alternative exchange as required by 33CFR151.1514.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Electrical › Lighting (service) › Lighting Fixture
Issued 16 November 1999 Resolved
Repair explosion proof lighting in Paint Locker.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Resolution: During the course of the inspection, the boardin team noted that this deficiency was corrected.
Lifesaving
Issued 16 November 1999 Resolved
Life boat engine to be working prior to departing from Anchorage.
Condition: Unknown
Due 16 November 1999
Resolved 16 November 1999
Engineering › Diesel Engine (propulsion-direct drive) › Injector (fuel injection)
Issued 16 November 1999 Resolved
Numerous oil leaks on main engine and auxiliary engines. Repair prior to_x001C_ Next US Port. Provide Class Report in writting to US Coast Guard.
Condition: Unknown
Due 26 November 1999
Resolved 16 November 1999
Resolution: During the course of the engine room inspection, the boarding team noted that the deficiency was fixed.
Construction/Loadline
Issued 18 March 1999 Resolved
PISTON BILGE PUMP ON PORT SIDE LOWER E/R IS PIPED DIRECTLY OVERBOARD_x001C_ MARPOL 73/78 ANNEX 1
Condition: Unknown
Due 26 March 1999
Resolved 23 March 1999
Unknown
Issued 8 September 1998 Resolved
AUXILIARY SALT WATER COOLING PUMP FOR GENERATORS NOT OPERABLE. (SOLAS 74(AMEND) REG 26.1)
Condition: Unknown
Due 29 September 1998
Resolved 29 September 1998
Fire Fighting
Issued 24 May 1996 Resolved
RENEW MISSING PORTABLE FIRE EXTINGUISHERS THROUGHOPUT THE ENGINE ROOM AND PROVIDE HOSES TO THE EXTINGUISHERS MISSING THEM._x001C_ SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Accommodation/Occupational Safety
Issued 24 May 1996 Resolved
FUMIGATE ALL FOOD STORAGE AND FOOD PREPERATION AREAS FOR INSECT INFESTATION. CLEAN FOOD PREPERATION AREAS._x001C_ ILO 147
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Navigation
Issued 24 May 1996 Resolved
CONDUCT SATISFACTORY TESTS OF SHIPS STEERING SYSTEMS. _x001C_ SOLAS 74 AMENDED 19-2(a)(b)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
CONDUCT A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING U.S. COAST GUARD INSPECTOR. _x001C_ SOLAS 74 AMENDED III-18.3
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Engineering
Issued 24 May 1996 Resolved
PROVE SATISFACTORY OPERATION OF THE SHIPS OILY WATER SEPERATING EQUIPMENT AND 15 PPM ALARM._x001C_ MARPOL 73/78 ANNEX I REG 16(2)(7)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW/REPAIR INOPERABLE EMERGENCY FIRE PUMP._x001C_ SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW/REPAIR INOPERABLE SEA WATER ISOLATION VALVE LOCATED IN THE ENGINE ROOM LOWER LEVEL AFT STBD SIDE SERVICING THE PIPING NOTED IN ITEM #0026. _x001C_SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW/REPAIR INOPERABLE MAIN FIRE PUMP_x001C_ SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Electrical
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE TO #1 MAIN GENERATOR LOCATED BENEATH THE DECK PLATES FWD OF THE GENERATOR (2 PIPES). SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER EJECTOR SUPPLY PIPE LOCATED STBD SIDE ENGINE ROOM. _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER DISCHARGE PIPE (6") LOCATED STBD SIDE ENGINE ROOM OUTBOARD THE CYLINDER COOLING SUPPLY PUMP #1. _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 24 May 1996 Resolved
RENEW MISSING WATERTIGHT HATCH DOGGING DEVICE FOR WATERTIGHT HATCH LOCATED AFT ENGINE ROOM CENTERLINE IN WAY OF ACCESS TO STEERING GEAR ROOM. _x001C_ ILLC 66 ANNEX I/12
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER SUPPLY PIPE (10") TO THE STEAM COOLER LOCATED STBD SIDE ON THE CONTROL ROOM DECK. _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Electrical
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPING FOR THE MAINGENERATOR LOCATED STBD SIDE ON THE CONTROL ROOM LEVEL _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW MISSING DOGGING DEVICE TO NATURAL VENTILATION CLOSURE LOCATED ON THE MAIN DECK FWD PORT SIDE._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED FIREHOSE LOCATED PORT SIDE BETWEEN #2 & #3 CARGO HOLDS._x001C_SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED FIREHOSE LOCATED PORT SIDE BETWEEN #3 & #4 CARGO HOLDS._x001C_SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED EVAPORATOR COOLING WATER SUPPLY PIPE LOCATEDSTBD SIDE ENGINE ROOM ON THE CONTROL ROOM DECK. _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW/REPAIR DETERIORATED SEA WATER SUPPLY ISOLATION VALVE LOCATED STBD SIDE ENGINE ROOM OUTBOARD AND ABOVE THE CYLINDER COOLING SUPPLY PUMP #1. _x001C_SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER SUPPLY PIPE TO ENGINE LUBE OIL COOLER LOCATED IN THE ENGINE ROOM 2ND DECK STBD SIDE _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER SUPPLY PIPE LOCATED IMMEDIATELY ACROSS FROM ITEM #0023 _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER SUPPLY PIPES (VARIOUS) LOCATED ON THE STBD SIDE OF THE MAIN DECK ENGINE AS FOLLOWS: 1-3" PIPE, 1-5" PIPE, 2- 6" PIPES, 1-8" PIPE. _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Lifesaving
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPING (3) LOCATED IN THE ENGHINE ROOM LOWER LEVEL AFT STBD TO THE OIL COOLER. _x001C_ SOLAS 74 AMENDED I/11(a)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW/REPAIR INOPERABLE VENTILATION DOORS (4) LOCATED ON THE BRIDGE DECK PORT SIDE. VENT DOORS SHALL MOVE FREELY AND REQUIRE ONLY ONE CREWMEMBER TO OPERATE._x001C_ SOLAS 74 II-2/24(c)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW AS ORIGINAL MISSING GASKET TO VENTILATION INLET FOR GALLEY LOCATED AFT CENTERLINE ON THE BRIDGE DECK._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 24 May 1996 Resolved
RENEW DETERIORATED GASKET TO WATERTIGHT HATCH LOCATED AFT CENTERLINE ON POOP DECK._x001C_ SOLAS 74 II-1/17(b)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 24 May 1996 Resolved
RENEW DETERIORATED GASKET TO THE WATERTIGHT EMERGENCY ESCAPE HATCH FROM THEENGINE ROOM LOCATED ON THE POOP DECK STBD SIDE._x001C_ SOLAS 74 II-1/17(b)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 24 May 1996 Resolved
RENEW DETERIORATED GASKET TO WATERTIGHT ESCAPE HATCH LOCATED ON THE POOP DECK PORT SIDE._x001C_ SOLAS 74 II-1/17(b)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED FIRE HOSE LOCATED STBD SIDE BETWEEN #4 & #5 CARGO HOLD._x001C_SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW MISSING NOZZLE TO FIRE STATION LOCATED ON THE STBD BRIDGE WING._x001C_ SOLAS 74 II-2/5(f)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED FIRE HOSE LOCATED STBD SIDE BETWEEN #3 & #4 CARGO HOLD._x001C_SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW DETERIORATED GASKET TO VENTILATION CLOSURE LOCATED ON THE MAIN DECK FWD PORT SIDE._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Fire Fighting
Issued 24 May 1996 Resolved
RENEW MISSING PORTABLE FIRE EXTINGUISHER FOR EMERGENCY GENERATOR ROOM._x001C_ SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 24 May 1996 Resolved
RENEW DETERIORATED GASKET AND ADJUST DOGGING DEVICES ON THE WATERTIGHT HATCH LOCATED ON THE FOC'SLE TO PROVIDE AN EFFECTIVE WATERTIGHT SEAL._x001C_ SOLAS 74 II-1/17(b)
Condition: Unknown
Due 12 June 1996
Resolved 13 June 1996
Unknown
Issued 9 April 1995 Resolved
ALTHOUGH VESSEL GENERALLY HAD A GOOD MARPOL V PROGRAM, A SMALL AMOUNT OF PLASTIC GARBAGE WAS FOUND IN ITS OVERBOARD FOOD BIN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Fire Fighting
Issued 9 April 1995 Resolved
VESSEL'S EMERGENCY FIRE PUMP WAS INOP.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Navigation
Issued 9 April 1995 Resolved
VSL HAD A MISSING COTTER PIN IN THE LEFT STEERING GEAR CONTROL.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Navigation
Issued 9 April 1995 Resolved
VESSEL INBOUND WITH ONE OF TWO REQUIRED RADARS DOWN.
Condition: Unknown
Due 4 May 1995
Resolved 4 May 1995
Navigation
Issued 19 February 1985 Resolved
TIDE TABLES NOT CURRENT.
Condition: Unknown
Due 19 February 1985
Resolved 19 February 1985
Navigation
Issued 19 February 1985 Resolved
CHART NOT OF LARGE ENOUGH SCALE FOR SAFE NAVIGATION
Condition: Unknown
Due 19 February 1985
Resolved 19 February 1985
Navigation
Issued 19 February 1985 Resolved
LIGHT LIST NOT CURRENTLY CORRECTED
Condition: Unknown
Due 19 February 1985
Resolved 19 February 1985
Navigation
Issued 19 February 1985 Resolved
TIDE CURRENT TABLES ONT CURRENT
Condition: Unknown
Due 19 February 1985
Resolved 19 February 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.