Inspection history · 23
1 November 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7819021
9 August 2023
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770040
9 August 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7789735
25 January 2023
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7631359
17 November 2022
Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7595838
20 December 2021
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7378793
5 November 2021
Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7345114
7 December 2020
Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087478
7 January 2020
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884641
14 November 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6856580
4 June 2019
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6702890
15 March 2019
Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6644807
22 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6614038
26 December 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6602971
18 December 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6600957
24 April 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402564
28 February 2018
Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6364136
12 February 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6354124
8 February 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6352869
12 January 2018
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6337228
3 September 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6274969
18 January 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6076547
7 November 2016
COI Inspection · DAPI Audit · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6033121
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 December 2021
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening in engine space was not equipped with means of closure outside of the engine room over every vent. Ensure closure devices can secure to outside of engine space.
46 CFR 182.465(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Engine ventilation covers provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 December 2021
Resolved
Fixed gas fire extinguishing systems are required to be serviced and inspected. Vessel required to provide satisfactory evidence of the required servicing. Vessel was unable to show servicing history of the fixed fire extinguishing system installed onboard the vessel. Provide satisfactory evidence of required servicing to attending marine inspector.
46 CFR 176.810(b)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Fire extinguisher servicing provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2021
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy retro reflective material is deteriorated and light is not operational. Replace retro reflective material and water
light.
46 CFR 176.808(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Water light and retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two lifejackets in unserviceable condition. Passenger count reduced by two.
46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 21 December 2021
Resolution: 02 lifejackets provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2021
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation; and be permanently mounted. Vessel's bilge pump missing visual indication light and not permanently mounted.
46 CFR 182.520(a),(e)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Auto bilge pump light operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2021
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Replace missing or broken bolts on awning.
46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Awning provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2021
Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel.
46 CFR67.123(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Vessel name provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 December 2021
Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Provide radio operator permit.
47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: MROP provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2021
Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel unable to provide logs for all drills including fire fighting drills and training. Submit proof of comprehensive logs and records of drills, records, and training onboard to Marine Inspector.
46 CFR185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Fire and MOB logs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2021
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol.
46 CFR 4.06-15 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Test strips provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 December 2021
Resolved
Each vessel must be equipment with at least two operable portable battery lights. Provide two portable battery lights.
46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Lights provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 December 2021
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first aid kit was expired. Provide new first aid kit.
46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: First aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 December 2021
Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Pilot [name withheld] List, tide tables, and current tables.
Vessel's Light List not up to date.
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Light list provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2020
Resolved
18 adult life jackets condemned. Provide 18 life jackets. Passenger count reduced by 18.
Action required: 705 - Other - as specified
Resolved 25 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 December 2020
Resolved
Bilge high water visual alarm not operational. Provide operational bilge high level visual alarm at helm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2020
Resolved
Vessel name not on port or starboard side of vessel. Provide name on port and starboard side of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2020
Resolved
Nav lights not operational. Provide operational navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2020
Resolved
Alternator seized, not able to get underway. Make repairs to alternator and get underway for trials.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2019
Resolved
Ring buoy light was extinguished. Repair/renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2019
Resolved 7 January 2020
Resolution: Light repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2019
Resolved
Engine compartment automatic bilge pump did not have visual indicator at the operating station. Provide indicator at operating station in accordance with 46 CFR 182.530.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2019
Resolved 7 January 2020
Resolution: Indicator provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 January 2019
Resolved
Fireboy system is missing manual activation function and will not secure engine upon activation. Prove correct operation in accordance with 46 CFR 181.420.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Fireboy manual cable installed and engine shutdown test conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2019
Resolved
Lifejacket retro-reflective material was unsatisfactory. Renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Retro satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 January 2019
Resolved
Ringbuoy retro-reflective material was unsatisfactory.
Renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Retro satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 January 2019
Resolved
Green navigation light was inoperable. Repair in accordance with 46 CFR 183.420. Vessel restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: Green light repaired.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 January 2019
Resolved
Provide proof of completion of required drills by all crew members in accordance with 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Resolution: Drills completed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 January 2019
Resolved
Provide e-pirb monthly testing documentation in accordance with 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Resolution: Test logged.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 December 2018
Resolved
Fireboy did not secure engine upon activation. Manual activation cable was disconnected. Prove correct operation/installation of Fireboy in accordance with 46 CFR 181.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Discrepancy duplicated and captured by activity 6614038.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2018
Resolved
Engine failed. Repair/renew engine in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 December 2018
Resolution: Engine renewed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 February 2018
Resolved
Bilge alarm inoeprative. Repair in accordance with 46CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2018
Resolution: Alarm repaired.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 February 2018
Resolved
FCC Safety Radiotelephony Certificate missing. Provide in accordance with 47CFR.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 24 April 2018
Resolution: Certificate provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 January 2017
Resolved
Provide serving certificates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2017
Resolution: Service by Valley Island Extinguishers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 January 2017
Resolved
Engine room blower doesn't turn off when fixed system is actuated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: Blower now secures when CO2 system is activated.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 January 2017
Resolved
Retro reflective tape not service able on half the lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: Retro was replaced on required lifejackets.
Lifesaving › Hand Flares › Storage
Issued 18 January 2017
Resolved
Flare storage is not adequate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: New storage box was provided.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 14 November 2016
Resolved
Replace dry rotted fuel fill hose.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Hose replaced.
Construction/Loadline › Hull › Side Shell
Issued 14 November 2016
Resolved
Repair cracked/broken FRP on bow area of air tube attachment system.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: FRP repaired.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 November 2016
Resolved
Vessel to obtain FCC Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: FCC certificate provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 7 November 2016
Resolved
Provide current MMSI and GPS for DSC radio.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Observed MMSI and GPS functions of DSC radio.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 November 2016
Resolved
Remove dead-end wiring from starboard aft compartment.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Wire removed.
Engineering › Steering Gear System › Rudder
Issued 7 November 2016
Resolved
Provide means for emergency steering.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Emergency steering arrangement provided.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 November 2016
Resolved
Properly label PFD storage locations with PFD numbers.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel properly labeled storage.
Documentation › Markings/Placards › Garbage Placard
Issued 7 November 2016
Resolved
Provide current garbage discharge placard.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel provided proper garbage placard.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 7 November 2016
Resolved
Provide emergency broadcast placard.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel provided placard.
Engineering › Bilge Water Management System › Pump
Issued 7 November 2016
Resolved
Provide visual indication of automatic bilge pump activation.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Observed properly operating indicator.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 November 2016
Resolved
Provide accurate emergency instructions at operators station.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel provided emergency instruction placard to be posted.