MAURY USCG vessel records Sign in
← All vessels

PONO KAI

PONO KAI is a 2001 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 2001, most recently in November 2023, along with 56 deficiencies and 1 casualty investigation in 2023.

Records from 2001 to 2023. Most recent: inspection, 1 November 2023.

Built
2001
Last inspected
1 November 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ2618
Flag
UNITED STATES
367760090
Maury page id
psix-24647

Inspections, by type

…with no type recorded6
Years with a record 18 calendar years (2001–2023)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.0 ft × 13.0 ft × 7.0 ft
Registered tonnagegross 17 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL WATER SPORTS, INC · LAKE HAVASU CITY, AZ, UNITED STATES · built 2001
Hull materialFRP (Fiberglass)
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ2618MMSI 367760090 · active · compulsorily equipped · granted 28 October 2016, expires 28 October 2026 · licensed under a name not among this hull’s recorded names (not shown)
WDH2852MMSI 367601860 · expired · compulsorily equipped · granted 14 January 2014, cancelled 16 March 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDF9962MMSI 367510670 · expired · compulsorily equipped · granted 29 November 2011, cancelled 29 January 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDE9473MMSI 367417630 · expired · compulsorily equipped · granted 7 July 2009, cancelled 7 September 2019 · licensed under a name not among this hull’s recorded names (not shown)
WDE4084MMSI 367348490 · expired · compulsorily equipped · granted 9 April 2008, cancelled 9 June 2018 · licensed under a name not among this hull’s recorded names (not shown)
WDC5902MMSI 367048220 · expired · compulsorily equipped · granted 8 June 2005, cancelled 8 August 2015 · licensed under a name not among this hull’s recorded names (not shown)
WDA6476MMSI 366832780 · expired · compulsorily equipped · granted 12 December 2001, cancelled 11 February 2012 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 43

1 November 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7819021
9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770040
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7789735
25 January 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7631359
17 November 2022 Drydock Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7595838
20 December 2021 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7378793
5 November 2021 Deficiency Check · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7345114
7 December 2020 Annual Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087478
7 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6884641
14 November 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6856580
4 June 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6702890
15 March 2019 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6644807
22 January 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6614038
26 December 2018 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6602971
18 December 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6600957
24 April 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6402564
28 February 2018 Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 6364136
12 February 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6354124
8 February 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6352869
12 January 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6337228
3 September 2017 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6274969
18 January 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6076547
7 November 2016 COI Inspection · DAPI Audit · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6033121
2 May 2012 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4308661
11 January 2012 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4222983
9 January 2012 Administrative Inspection · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4254315
10 September 2010 COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3770187
11 June 2008 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3233607
2 June 2008 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3225049
20 September 2007 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3042641
18 September 2006 Re-Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2781014
19 June 2006 Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2685019
24 May 2005 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2366998
4 April 2005 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2326323
2 February 2005 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2284938
11 March 2004 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2025888
14 May 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1792615
10 February 2003 Annual Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1736307
3 June 2002 In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1625589
29 April 2002 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1608782
4 May 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1063489
20 April 2001 Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1456970
22 March 2001 Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1426564

Deficiency record · 56

07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 9 December 2021 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Ventilation duct opening in engine space was not equipped with means of closure outside of the engine room over every vent. Ensure closure devices can secure to outside of engine space. 46 CFR 182.465(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Engine ventilation covers provided.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 9 December 2021 Resolved
Fixed gas fire extinguishing systems are required to be serviced and inspected. Vessel required to provide satisfactory evidence of the required servicing. Vessel was unable to show servicing history of the fixed fire extinguishing system installed onboard the vessel. Provide satisfactory evidence of required servicing to attending marine inspector. 46 CFR 176.810(b)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Fire extinguisher servicing provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2021 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring buoy retro reflective material is deteriorated and light is not operational. Replace retro reflective material and water light. 46 CFR 176.808(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Water light and retro tape provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2021 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Two lifejackets in unserviceable condition. Passenger count reduced by two. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 21 December 2021
Resolution: 02 lifejackets provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2021 Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation; and be permanently mounted. Vessel's bilge pump missing visual indication light and not permanently mounted. 46 CFR 182.520(a),(e)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Auto bilge pump light operational.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Replace missing or broken bolts on awning. 46 CFR 177.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2021
Resolution: Awning provided.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2021 Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. 46 CFR67.123(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Vessel name provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 9 December 2021 Resolved
Each ship transporting more that six passengers for hire equipped with a radiotelephone station must carry a radio operator who: holds a marine radio operator permit or higher class license. Provide radio operator permit. 47 CFR 80.158 (e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: MROP provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2021 Resolved
Firefighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel unable to provide logs for all drills including fire fighting drills and training. Submit proof of comprehensive logs and records of drills, records, and training onboard to Marine Inspector. 46 CFR185.524(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Fire and MOB logs provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2021 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel does not have any means to test for presence of alcohol. 46 CFR 4.06-15 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Test strips provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 December 2021 Resolved
Each vessel must be equipment with at least two operable portable battery lights. Provide two portable battery lights. 46 CFR 183.430
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Lights provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 December 2021 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel's first aid kit was expired. Provide new first aid kit. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: First aid kit provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 December 2021 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Pilot [name withheld] List, tide tables, and current tables. Vessel's Light List not up to date. 46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 January 2022
Resolved 10 January 2022
Resolution: Light list provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 December 2020 Resolved
18 adult life jackets condemned. Provide 18 life jackets. Passenger count reduced by 18.
Action required: 705 - Other - as specified
Resolved 25 January 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 December 2020 Resolved
Bilge high water visual alarm not operational. Provide operational bilge high level visual alarm at helm.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 December 2020 Resolved
Vessel name not on port or starboard side of vessel. Provide name on port and starboard side of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 January 2021
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2020 Resolved
Nav lights not operational. Provide operational navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 December 2020 Resolved
Alternator seized, not able to get underway. Make repairs to alternator and get underway for trials.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 November 2019 Resolved
Ring buoy light was extinguished. Repair/renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 December 2019
Resolved 7 January 2020
Resolution: Light repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 November 2019 Resolved
Engine compartment automatic bilge pump did not have visual indicator at the operating station. Provide indicator at operating station in accordance with 46 CFR 182.530.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 December 2019
Resolved 7 January 2020
Resolution: Indicator provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 January 2019 Resolved
Fireboy system is missing manual activation function and will not secure engine upon activation. Prove correct operation in accordance with 46 CFR 181.420.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Fireboy manual cable installed and engine shutdown test conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 January 2019 Resolved
Lifejacket retro-reflective material was unsatisfactory. Renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Retro satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 January 2019 Resolved
Ringbuoy retro-reflective material was unsatisfactory. Renew in accordance with 46 CFR 176.808.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Retro satisfactory.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 January 2019 Resolved
Green navigation light was inoperable. Repair in accordance with 46 CFR 183.420. Vessel restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 June 2019
Resolution: Green light repaired.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 22 January 2019 Resolved
Provide proof of completion of required drills by all crew members in accordance with 46 CFR 185.420.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Resolution: Drills completed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 22 January 2019 Resolved
Provide e-pirb monthly testing documentation in accordance with 46 CFR 185.728.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 March 2019
Resolution: Test logged.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 December 2018 Resolved
Fireboy did not secure engine upon activation. Manual activation cable was disconnected. Prove correct operation/installation of Fireboy in accordance with 46 CFR 181.420.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 March 2019
Resolution: Discrepancy duplicated and captured by activity 6614038.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 December 2018 Resolved
Engine failed. Repair/renew engine in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 December 2018
Resolution: Engine renewed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 February 2018 Resolved
Bilge alarm inoeprative. Repair in accordance with 46CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2018
Resolution: Alarm repaired.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 February 2018 Resolved
FCC Safety Radiotelephony Certificate missing. Provide in accordance with 47CFR.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 March 2018
Resolved 24 April 2018
Resolution: Certificate provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 18 January 2017 Resolved
Provide serving certificates.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 January 2017
Resolution: Service by Valley Island Extinguishers.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 January 2017 Resolved
Engine room blower doesn't turn off when fixed system is actuated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: Blower now secures when CO2 system is activated.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 18 January 2017 Resolved
Retro reflective tape not service able on half the lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: Retro was replaced on required lifejackets.
Lifesaving › Hand Flares › Storage
Issued 18 January 2017 Resolved
Flare storage is not adequate
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2017
Resolution: New storage box was provided.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 14 November 2016 Resolved
Replace dry rotted fuel fill hose.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Hose replaced.
Construction/Loadline › Hull › Side Shell
Issued 14 November 2016 Resolved
Repair cracked/broken FRP on bow area of air tube attachment system.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: FRP repaired.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 November 2016 Resolved
Vessel to obtain FCC Safety Radio Telephony Certificate.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: FCC certificate provided.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 7 November 2016 Resolved
Provide current MMSI and GPS for DSC radio.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Observed MMSI and GPS functions of DSC radio.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 November 2016 Resolved
Remove dead-end wiring from starboard aft compartment.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Wire removed.
Engineering › Steering Gear System › Rudder
Issued 7 November 2016 Resolved
Provide means for emergency steering.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Emergency steering arrangement provided.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 November 2016 Resolved
Properly label PFD storage locations with PFD numbers.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel properly labeled storage.
Documentation › Markings/Placards › Garbage Placard
Issued 7 November 2016 Resolved
Provide current garbage discharge placard.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel provided proper garbage placard.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 7 November 2016 Resolved
Provide emergency broadcast placard.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel provided placard.
Engineering › Bilge Water Management System › Pump
Issued 7 November 2016 Resolved
Provide visual indication of automatic bilge pump activation.
Action required: 705 - Other - as specified
Resolved 22 November 2016
Resolution: Observed properly operating indicator.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 7 November 2016 Resolved
Provide accurate emergency instructions at operators station.
Action required: 705 - Other - as specified
Resolved 14 November 2016
Resolution: Vessel provided emergency instruction placard to be posted.
Engineering › Thrusters › Hose
Issued 10 September 2010 Resolved
Renew double hose clamps on prop blowback.
Action required: 705 - Other - as specified
Resolved 20 March 2012
Resolution: Marine Inspector determined double hose clamps on prop blowback were unnecessary due to the fact that the hose is single clamped onto a barbed fitting.
Communications › Alarms/Indicators › High Water Alarm
Issued 10 September 2010 Resolved
Install high water alarm in bow thruster space.
Action required: 705 - Other - as specified
Resolved 1 May 2012
Resolution: Owner stated that bow thruster space drains to aft bilges and thus, does not need a high water alarm.
Navigation › Piloting/Steering › Magnetic Compass
Issued 10 September 2010 Resolved
Provide light for compass.
Action required: 705 - Other - as specified
Resolved 20 March 2012
Resolution: Verified a light was installed and operational on magnetic compass.
Communications › Radio Communications › EPIRB
Issued 10 September 2010 Resolved
Provide EPIRB hydro expiration date.
Action required: 705 - Other - as specified
Resolved 20 March 2012
Resolution: Verified EPIRB hydro-static release expiration date is currently valid.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 10 September 2010 Resolved
Prove Fire Boy system is installed IAW manufacture recommendations.
Action required: 705 - Other - as specified
Resolved 19 December 2011
Resolution: Conducted a full satisfactory test of Fire Boy system as a part of COI (Act#4058989). Verified engine shutdown and override were operational.
Construction/Loadline › Structures › Cofferdam
Issued 10 September 2010 Resolved
Repair baffle leak between forward compartment and stbd middle compartment.
Action required: 705 - Other - as specified
Resolved 1 May 2012
Resolution: As part of DD/ISE on 19Dec2011, conducted an overpressure collar "stress" test iaw MTN 1-08 to the sponsons, at 4.3 psi, which verified that the baffle leak has been repaired.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 September 2010 Resolved
Conduct DAPI Audit prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2011
Resolution: Conducted satisfactory DAPI Audit as a part of COI (Act#4058989).
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 29 April 2002 Resolved
Provide evidence of an active EAP.
Due 6 May 2002
Resolved 3 May 2002
Engineering
Issued 20 April 2001 Resolved
INSTALL FUEL SHUTOFF VALVE IN ENGINE ROOM.
Condition: Unknown
Due 25 April 2001
Resolved 4 May 2001
Electrical
Issued 20 April 2001 Resolved
REMOVE WINGNUTS AND INSTALL PERMANENT FASTENER ON BATTERY POSTS.
Condition: Unknown
Due 25 April 2001
Resolved 4 May 2001
Accommodation/Occupational Safety
Issued 20 April 2001 Resolved
INSTALL RAIL ON TRANSOM THAT MEETS MINIMUM DECK RAIL REQUIREMENT.
Condition: Unknown
Due 25 April 2001
Resolved 4 May 2001

Casualty record · 1

9 August 2023Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7789735
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.