MAURY USCG vessel records Sign in
← All vessels

SHOWTIME

SHOWTIME is a 1984 passenger vessel (inspected). The Coast Guard has recorded 44 inspections since 1985, most recently in June 2004, along with 74 deficiencies and 1 casualty investigation in 2004.

Records from 1985 to 2004. Most recent: inspection, 1 June 2004.

Built
1984
Last inspected
1 June 2004
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDA3998
246549
Flag
UNITED STATES
366804640 (licence lapsed)
Maury page id
psix-246549

Inspections, by type

…with no type recorded4
Years with a record 19 calendar years (1985–2004)
The 44 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)44.5 ft × 14.0 ft × 5.5 ft
Registered tonnagegross 23 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH AL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 26 November 2003 · expires 31 December 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it23 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA3998MMSI 366804640 · expired · compulsorily equipped · granted 20 March 2001, cancelled 21 May 2011
WCH9815MMSI not assigned · expired · compulsorily equipped · granted 3 June 1994, cancelled 8 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THERAPY Passenger (Inspected) · MISLE 150188 · 1 June 2004 · activity 2086250

Inspection history · 44

1 June 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2086250
1 June 2004 Damage Survey · Administrative Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2087091
2 April 2004 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2036342
17 April 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1774008
16 January 2003 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1720207
6 May 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1613658
12 April 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1494891
9 May 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063738
3 April 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393636
16 January 2001 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 825344
16 January 2001 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1060225
28 April 1999 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1126953
10 April 1998 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1126949
9 March 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1383875
13 June 1997 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 776524
2 May 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404370
21 January 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1460047
15 April 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1404148
21 April 1995 Re-Inspection · Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1444973
5 January 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1374173
28 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 861609
10 May 1993 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 837782
21 April 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1143016
11 March 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1145656
30 September 1992 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 948140
25 June 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 957711
23 April 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1262762
25 March 1992 Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1255996
9 September 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 935179
30 April 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1212499
5 March 1991 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 916392
26 February 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226641
21 May 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 930454
19 September 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334047
28 August 1989 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891597
9 June 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 895374
14 June 1988 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1344868
18 May 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1351434
18 March 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1302774
7 January 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1322957
8 December 1987 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1312948
17 June 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1310667
9 December 1986 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1334098
19 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1289974

Deficiency record · 74

Communications › Alarms/Indicators
Issued 28 April 2004 Resolved
Renew bilge high level alarms. LEGACY COMPONENT DESC: High Water Alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 April 2004
Resolved 28 April 2004
Resolution: High level alarms renewed. Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I)
Issued 28 April 2004 Resolved
Renew retro-reflective tape on 6 PFD's. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 April 2004
Resolved 28 April 2004
Resolution: Retro-reflective tape on 6 PFD''''s renewed. Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 28 April 2004 Resolved
Renew lights on 2 PFD's.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 April 2004
Resolved 28 April 2004
Resolution: Lights renewed on 2 PFD''s.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2004 Resolved
Renew asprin & eyewash in first aid kit.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 28 April 2004
Resolution: Asprin & eyewash renewed. Corrected on the spot.
Communications › Radio Communications › EPIRB
Issued 17 April 2003 Resolved
Replace hydrostatic release on the EPIRB.
Due 17 April 2003
Resolved 17 April 2003
Resolution: Replaced during inspection.
Engineering › Steering Gear System
Issued 16 January 2003 Resolved
Repair steering gear system to remove excess play from rudder system to the satisfaction of the attending marine inspector. LEGACY COMPONENT DESC: Rudder
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 February 2003
Resolved 25 February 2003
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 April 2002 Resolved
Provide up to date Navigation Publications as required by CFR184.420.
Due 1 May 2002
Resolved 6 May 2002
Personnel › Manning/Qualifications
Issued 12 April 2002 Resolved
Provide current CPR training cards as required by nvic 1-91. Provide current annual testing cards as required by 46 CFR part 16. LEGACY COMPONENT DESC: CPR Certified Personnel
Due 1 May 2002
Resolved 6 May 2002
Electrical
Issued 3 April 2001 Resolved
PROVIDE PROPER WIRING FOR OIL TRANSFER PUMP AND LIVE WELL PUMP AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 3 May 2001
Resolved 14 May 2001
Electrical
Issued 3 April 2001 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING AS REQUIRED BY 46 CFR 183.432._x001C_ VESSEL IS RESTRICTED TO DAYLIGHT OPERATION ONLY UNTIL CORRECTED.
Condition: Unknown
Due 3 May 2001
Resolved 14 May 2001
Electrical
Issued 3 April 2001 Resolved
PROVIDE PROPER WIRING FOR FREEZER AS REQUIRED BY 46 CFR 183.340
Condition: Unknown
Due 3 May 2001
Resolved 14 May 2001
Engineering
Issued 3 April 2001 Resolved
PROVIDE PROPER PIPING FOR RAW WATER SUCTION AS REQUIRED BY 46 CFR 182.700
Condition: Unknown
Due 3 May 2001
Resolved 14 May 2001
Electrical
Issued 9 March 1998 Resolved
PROVE PROPER OPERATION OF THE GENERATOR. 46 CFR 176.806(e).
Condition: Unknown
Due 9 April 1998
Resolved 20 May 1998
Navigation
Issued 9 March 1998 Resolved
CONDUCT SATISFACTORY MAN OVERBOARD, FIRE AND ABANDON VESSEL DRILLS. SEE 46 CFR 176.808(g).
Condition: Unknown
Due 9 April 1998
Resolved 20 May 1998
Accommodation/Occupational Safety
Issued 2 May 1997 Resolved
INSTALL A 30X30 MESH SCREEN ON THE MSD TANK VENT._x001C_ 33 CFR 159.95(a)(2).
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Lifesaving
Issued 2 May 1997 Resolved
PROVIDE A PROPER SIZE APPROVED WEAKLINK FOR THE VESSELS LIFEFLOAT._x001C_ 46 CFR 180.130(a)(1)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Unknown
Issued 2 May 1997 Resolved
PROVIDE EVIDENCE THAT 50% OF THE CREW HAVE VALID FIRST AID/CPR TRAINING/CARDS._x001C_ NVIC 1-91
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Lifesaving
Issued 2 May 1997 Resolved
PROVIDE A PROPER LIFEJACKET DONNING PLACARD._x001C_ 46 CFR 185.516_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Engineering
Issued 2 May 1997 Resolved
PROVIDE FUEL SHUTOFF VALVES AT BOTH MAIN ENGINES AND THE GENERATOR PRIME MOVER._x001C_ 46 CFR 182.455(b)(4)
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Engineering
Issued 2 May 1997 Resolved
INSTALL A 30X30 MESH SCREEN ON BOTH FUEL TANK VENT LINES._x001C_ 46 CFR 182.450(e).
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Construction/Loadline
Issued 2 May 1997 Resolved
PROVIDE AND PROVE PROPER OPERATION OF THE BILGE/FIRE HAND PUMP._x001C_ 46 CFR 182.520
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Documentation
Issued 2 May 1997 Resolved
PROVIDE ON BOARD VESSEL, AN UP TO DATE TRAINING LOG IAW 46 CFR 185.420
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Accommodation/Occupational Safety
Issued 2 May 1997 Resolved
PROVE PROPER OPERATION OF THE VESSEL'S TYPE III MSD SYSTEM._x001C_ 46 CFR 176.818
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Fire Fighting
Issued 2 May 1997 Resolved
CONDUCT A SATISFACTORY FIRE, MAN OVERBOARD AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR._x001C_ 46 CFR 185.520
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Construction/Loadline
Issued 2 May 1997 Resolved
RENEW/REPAIR DELAMINATED SECTION OF VESSEL'S CABIN LOCATED ON THE STBD SIDEOF THE CABIN._x001C_ NVIC 8-87
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Lifesaving
Issued 2 May 1997 Resolved
RENEW DETERIORATED LIFEFLOAT SEA PAINTER._x001C_ 46 CFR 185.175
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Lifesaving
Issued 2 May 1997 Resolved
RENEW DETERIORATED SEA PAINTER FOR LIFEFLOAT WATERLIGHT._x001C_ 46 CFR 180.70(c)(4)
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Lifesaving
Issued 2 May 1997 Resolved
RENEW 60' LIFELINE ATTACHED TO THE RING LIFEBUOY WITH THE PROPER SIZE LINE._x001C_ 46 CFR 180.70(c)(4)
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Construction/Loadline
Issued 2 May 1997 Resolved
PROVIDE A 6" WATERTIGHT COAMING FOR THE WEATHERTIGHT DOOR LOCATED ON THE MAINDECK._x001C_ 46 CFR 179.360(d)
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Documentation
Issued 2 May 1997 Resolved
PROVIDE ON BOARD VESSEL A VALID FCC SAFETY RADIO CERTIFICATE._x001C_ 47 CFR 80.903
Condition: Unknown
Due 2 May 1997
Resolved 2 May 1997
Lifesaving
Issued 21 April 1995 Resolved
STENCIL FLARE CONTAINER WITH VESSEL'S NAME.
Condition: Unknown
Due 21 May 1995
Resolved 28 June 1995
Accommodation/Occupational Safety
Issued 21 April 1995 Resolved
PROVIDE MEANS FOR LOCKING MSD OVERBOARD VALVE.
Condition: Unknown
Due 21 May 1995
Resolved 28 June 1995
Navigation
Issued 21 April 1995 Resolved
PROVIDE THREE BLACK BALL DAY-SHAPES IN ACCORDANCE WITH 72 COLREGS.
Condition: Unknown
Due 21 May 1995
Resolved 28 June 1995
Documentation
Issued 21 April 1995 Resolved
RENEW OIL POLLUTION PLACARD.
Condition: Unknown
Due 21 May 1995
Resolved 28 June 1995
Electrical
Issued 21 April 1995 Resolved
PROVIDE DOCUMENTATION THAT GENERATOR HAS BEEN DERATED TO 80% OF DESIGNED LOAD.
Condition: Unknown
Due 21 May 1995
Resolved 28 June 1995
Engineering
Issued 21 April 1993 Resolved
PROVIDE PROPER FLAME SCREENS IAW 46 CFR 182.20-35. EXISTING SCREEN LARGER THAN 30 X 30 MESH.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Documentation
Issued 21 April 1993 Resolved
POST STABILITY LETTER IAW 46 CFR 179.20.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Documentation
Issued 21 April 1993 Resolved
PROVIDE VALID FCC RADIO STATION LICENSE IAW 46 CFR 184.25 (EXPIRED 14JAN93).
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Engineering
Issued 21 April 1993 Resolved
PROPERLY WELD WET EXHAUST MANIFOLD, PORT ENGINE IAW 46 CFR 182.15-20(4). JOINT IS CRACKED.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Electrical
Issued 23 April 1992 Resolved
PROVE PROPER OPERATION AND INSTALLATION OF AC GENERATOR._x001C_
Condition: Unknown
Due 23 April 1992
Resolved 23 April 1992
Electrical
Issued 30 April 1991 Resolved
INSTALL VOLTMETER, AMPMETER, AND FREQUENCY METER IN A/C GEN. PANEL_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Lifesaving
Issued 30 April 1991 Resolved
RENEW OR REPAIR SIX MAN LIFEFLOAT. UNTIL REPAIRS ARE MADE TOTAL PERSONS IS REDUCED TO 14 TOTAL. ONE RING BUOY TO BE PROVIDED WITH LIGHT ATTACHED IN ADDITION TO RING BUOY REQUIRED.
Condition: Unknown
Due 30 April 1991
Resolved 30 April 1991
Engineering
Issued 21 May 1990 Resolved
INSTALL STRAINERS ON THE INDIVIDUAL BILGE SUCTION LINES.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Electrical
Issued 21 May 1990 Resolved
REMOVE DEAD ENDED WIRING OR INSTALL IN APPROPRIATE JUNCTION BOXES.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Documentation
Issued 21 May 1990 Resolved
SUBMIT CERTIFICATE OF DOCUMENTATION TO DOCUMENTATION OFFICER IN NEW ORLEANSAND HAVE VESSELS OWNER'S ADDRESS CHANGED.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Electrical
Issued 21 May 1990 Resolved
INSTALL A 55 AMP CIRCUIT BREAKER IN THE MAIN SWITCHBOARD TO DERATE THE 50 DEGREE CELCIUS GENERATOR TO 80 PERCENT OF FULL LOAD RATING.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Unknown
Issued 9 June 1989 Resolved
VENT HOLDING TANK TO VESSEL'S OUTSIDE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
PROVIDE WEAKLINK FOR 11-20 PERSONS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
MAKE UP LINES ON LIFE FLOATS WITH SAILOR COTTON TWINE.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
REPLACE PORT RING BUOY.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
DEMONSTRATE OPERATION OF FWD BILGE PUMP.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
DEMONSTRATE OPERATION OF STERN LIGHT.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
REPLACE HANDLE TO WATER TANK SHUT OFF.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
REPLACE FLAME SCREENS PORT AND STARBOARD.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
PROVIDE WATERTIGHT CONTAINER FOR PYROTECHNICS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
STENCIL FUEL SHUTOFFS.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Unknown
Issued 9 June 1989 Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Lifesaving
Issued 18 May 1988 Resolved
INSTALL AN APPROVED WATERLIGHT AND (60)SIXTY OF LINE ON THE RING BUOY.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Lifesaving
Issued 18 May 1988 Resolved
MARK APPROPRIATE LIFE JACKET LOCKER AS "ADULT".
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Electrical
Issued 18 May 1988 Resolved
INSTALL FREQUENCY MEASURING DEVICE FOR GENERATOR.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Lifesaving
Issued 18 May 1988 Resolved
PROVIDE 3 ADDITIONAL RED AND 3 ADDITIONAL ORANGE FLARES.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Navigation
Issued 8 December 1987 Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Electrical
Issued 8 December 1987 Resolved
REPOSITION STERN LIGHT OR REMOVE AFTER BIMINI COVER TO REVEAL SAME.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987 Resolved
STENCIL ALL PADDLES AND THE STARBOARD LIFEFLOAT.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987 Resolved
HOOK-UP BOTH WATER LIGHTS TO LIFEFLOATS.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987 Resolved
PROVIDE AND INSTALL AN APPROVED TYPE WEAK LINK AND INSTALL ON LIFEFLOATS.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Electrical
Issued 8 December 1987 Resolved
PROVIDE CRIMP CONNECTIONS FOR ALL BILGE PUMP CONNECTIONS.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Accommodation/Occupational Safety
Issued 8 December 1987 Resolved
PROVIDE A HOLDING TANK FOR THE MARINE TOILET.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987 Resolved
POST EMERGENCY CHECK LIST.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Documentation
Issued 8 December 1987 Resolved
POST THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987 Resolved
PROVIDE A BATTERY FOR EPRIRB.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Fire Fighting
Issued 8 December 1987 Resolved
PROVIDE EVIDENCE OF THE ANNUAL SERVICING FOR ALL FOUR FIRE EXTINGUISHER.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Documentation
Issued 9 December 1986 Resolved
OBTAIN AND PLACE ONBOARD A VALID FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986
Engineering
Issued 9 December 1986 Resolved
REPLACE CURRENT PLASTIC FLEXIBLE DUCT ON ENGINE ROOM VENT STARBOARD SIDE WITH A RIGID, FIRE PROOF DUCT.
Condition: Unknown
Due 9 December 1986
Resolved 9 December 1986

Casualty record · 1

1 June 2004Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2086250
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.