Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 2 November 2015
No resolution recorded
Tug STRONG which pushes the MARINER has a demaged Artubar Pin which needs repair at a qualified yard. Vessel may not carry cargo after dischasge in Abu Dhabi, UAE. Cargo free transit to a qualified ship yard is allowed in order to affect repairs. This is an update of previously issued 835. A 28NOV15 resolve date issued to allow transit time of 17-21 days.
Due 28 November 2015 — due date passed with no resolution recorded
Deck/Cargo › Towing › Towline
Issued 25 August 2015
Resolved
The towing vessel STRONG's artubar pin is currently inoperable and unable to be disconnected from the barge MARINER. A temporary repair has been made to mechanically lock the pin into place until permanent repairs are made. The barge MARINER may operate commercially from Singapore to Shanghai, PRC and then to Abu Dhabi, UAE. After arrival in Abu Dhabi, UAE, the barge MARINER may no longer operate
Condition: Damaged By Earlier Event
Due 10 October 2015
Resolved 2 November 2015
Resolution: 835 to be amended and re-issued.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 25 August 2015
No resolution recorded
Barge ventilation system alarms don't function IAW requirements for RO/RO vessels. During cargo ops, all personnel in the vehicle cargo spaces must wear personal gas detectors to monitor CO levels. Also, regular rounds must be made to ensure all ventilation is operating properly.
Condition: Damaged By Earlier Event
Due 10 October 2015 — due date passed with no resolution recorded
Deck/Cargo › Towing › Terminal Gear
Issued 20 July 2015
Resolved
The tug STRONG has suffered a malfunction to the hydraulic system that properly engages and disengages the tug from the barge MARINER. A temporary system has been installed with portable hydraulic rams that will engage the Artubar pins of the tug into the receiver of the barge, with procedures to manually disengage the system. The vessels are allowed to transit to Singapore with the reviewed modif
Action required: 705 - Other - as specified
Due 10 August 2015
Resolved 2 November 2015
Resolution: Cleared. Updated by activity 5755281.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 28 May 2014
Resolved
Breakers improperly labeled and blanks/breakers were missing.
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Resolution: Provided proper labels and blanks
Fire Fighting › Fire Main › Valves
Issued 28 May 2014
Resolved
Valves difficult to open and close making it necessary for crew mbrs to use crow bar to accuate valves.
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Resolution: [name withheld] attested to proper operation of the valves. Vessel hired a fire service contractor to recondition the valves and he witnessed the proper operation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 May 2014
Resolved
Dead end out of service wires located near the forward ramp space and in the wheelhouse of the tug need to be removed.
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Resolution: [name withheld] attested that the electrician removed all wiring and out of service limit switches.
Engineering › Fuel Oil Service System › Valve
Issued 28 May 2014
Resolved
Provide a remote fuel cut-off valve for the fwd generator and label it at the cut off station.
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Resolution: [name withheld] attested to Foss hiring a contractor to provide a suitable means of fuel shut off and labeling it with yellow hi-vis paint.
Communications › Radio Communications › EPIRB
Issued 15 May 2014
Resolved
EPIRB not registered with NOAA
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Communications › Radio Communications › VHF Radiotelephone
Issued 15 May 2014
Resolved
One of their emergency radios is inop.
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Resolution: [name withheld] attested to the replacement of the inoperable radio.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 15 May 2014
Resolved
SART was expired
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Resolution: [name withheld] attested to replacement of SART and provided certs.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Emergency shutdown
Issued 15 May 2014
Resolved
engine's manual shut down is inop
Action required: 705 - Other - as specified
Due 28 June 2014
Resolved 18 June 2014
Construction/Loadline › Hull › Side Shell
Issued 23 January 2014
Resolved
Substantial plate deterioration was found in ventilation plenum 5 (Frame 74 - 75 Stbd, 12 foot flat and above). Gauge existing area, crop and renew as necessary in accordance with USCG & ABS rules.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2014
Resolution: ABS Certified steel inserts.
Construction/Loadline › Structures › Deck Plating
Issued 23 January 2014
Resolved
Crop and renew deck/web at frame 27 Stbd in forward pump room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2014
Resolution: ABS attested to satisfactory inserts.
Engineering › Thrusters › Bearing
Issued 23 January 2014
Resolved
Provide plan for repair/replace/removal of bow thruster.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 April 2014
Resolved 1 April 2014
Resolution: Thruster will be repaired during 2015 dry docking.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 19 November 2010
Resolved
Repair Fire Detection system prior to departure, secondary power source (battery) inoperative, battery charger inoperative, undiagnosed 'Trouble' fault in 'Switch', secondary fan inadequate to support smoke extraction and draws 'vacuum' trouble alarm. Received notification of repair, left deficiency open to verify continued proper service at next inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 February 2012
Resolved 22 November 2011
Resolution: Verified correction of requirement.
Engineering › Bilge Water Management System › Piping
Issued 19 November 2010
Resolved
Repair/install reach rods for ovbd shell valves located below the freeboard deck, to include bilge/firemain sea suction valve previously operated by remote motor contol-now inoperative. Received Photos of correction 12/20/2011. Left deficiency open for verification at next attendance.
Condition: Improper Installation
Due 21 February 2012
Resolved 22 November 2011
Resolution: Verified correction of requirement.
Fire Fighting › Fire Main › Valves
Issued 19 November 2010
Resolved
Repair/replace leaking fire hydrant and sprinkler system isolation valves pointed out during inspection prior to departure. Received email of correction, extended def for verification at next inspection.
Condition: Improper/Lack of Maintenance
Due 21 February 2012
Resolved 22 November 2011
Resolution: Verified correction of requirement.
Construction/Loadline › Structures › Scuttle
Issued 19 November 2010
Resolved
Repair deck scuttle leading from CO2 space to lower space, due to noted wastage holes, and missing holdback device.
Condition: Improper/Lack of Maintenance
Due 20 December 2010
Resolved 5 December 2010
Resolution: Received photographic evidence of correction by email.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 19 November 2010
Resolved
Troublseshoot and repair as necessary (to include replacement of failed battery charger) alarm annunciator system for ventilation failure, smoke detection, and power failure alarms for both systems prior to departure. Hold training for crewmembers on the various alarms to ensure familiarity by watchstanders.
Condition: Improper/Lack of Maintenance
Due 12 December 2010
Resolved 20 December 2010
Resolution: Received email of training record.
Fire Fighting › Ventilation Systems › Ducts
Issued 19 November 2010
Resolved
Repair fire damper in ventilation ducting in under ramp storage area.
Condition: Improper/Lack of Maintenance
Due 20 December 2010
Resolved 5 December 2010
Resolution: Received photographic evidence of correction via email.
Fire Fighting › Ventilation Systems › Ducts
Issued 19 November 2010
Resolved
Repair ventilation ducting panels not properly in place in under ramp storage area.
Condition: Improper/Lack of Maintenance
Due 20 December 2010
Resolved 5 December 2010
Resolution: Received photogrpahic evidence of correction by email.
Engineering › Diesel Engine (auxiliary) › Valve
Issued 19 November 2010
Resolved
Provide handwheel for valve at stbd-side overboard discharge between frames 39 and 40, stbd side tank top level. (Appears to serve ovbd raw water cooling for generator engine.)
Condition: Improper/Lack of Maintenance
Due 20 December 2010
Resolved 3 December 2010
Resolution: Received photographic evidence of correction.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 19 November 2010
Resolved
Master to submit non-conformity/corrective action report in accordance with vsl SMS concerning failure to replace battery charger on fire/smoke detection system in 2009 and 2010 reports from vendor who conducted inspection.
Condition: Improper/Lack of Maintenance
Due 4 December 2010
Resolved 7 December 2010
Resolution: Received NCCAR, Master and Cheng will review and verify servicing reports.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 19 November 2010
Resolved
Install emergency lighting at escape route to stbd raceway lamp room from cargo space.
Condition: Improper Installation
Due 20 December 2010
Resolved 5 December 2010
Resolution: Received photographic evidence of correction by email.
Fire Fighting › Ventilation Systems › Ducts
Issued 19 November 2010
Resolved
Repair damaged ventilation ducting in electrical stores area forward.
Condition: Improper/Lack of Maintenance
Due 20 December 2010
Resolved 5 December 2010
Resolution: Received photographic evidence of correction by email.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 19 November 2010
Resolved
Repair wasted sections of sprinkler piping as noted on ACTC Worklist, prior to departure, provide report of completed repairs to ACTEUR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 November 2010
Resolution: Received report of completion of repairs.
Construction/Loadline › Structures › Deck Plating
Issued 19 November 2010
Resolved
CO2 Cylinder storage space decking was noted with low UT gaugings indicating substantial wastage. Crop and renew identified 1' x 3' area. in aft inboard corner. (See documentation for UT report.)
Condition: Improper/Lack of Maintenance
Due 30 September 2011
Resolved 22 November 2011
Resolution: Verified correction of requirement.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 September 2008
Resolved
Provide gauging report for the following identified areas: Tank Top Stbd. side Fan Room aft bulkhead, Aft Bulkhead of Main Upper Deck, frames 71-72(P), 82-83(P), 42-43(P), and 71-72(S). Gauging shall be done to good steel and calibration provided for equipment employed. All information to be submitted to cognizant OCMI.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Electric Generation Source (service) › Power Requirement
Issued 8 September 2008
Resolved
Properly clean and prove proper operation of service diesel generator within guidelines/specifications from attending service technician to include demonstration of all failsafe features and alarms to satisfaction of attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 8 September 2008
Resolved
Prove proper operation of fire detection system, ventilation shut downs, and all associated alarms and indicators within guidelines/specifications from attending service technician to satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 8 September 2008
Resolved
Prove proper operation of fixed high pressure CO2 extinguishing system and provide annual servicing report from attending service technician to satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 8 September 2008
Resolved
Repair and prove proper operation of fixed salt water sprinkler system to satisfaction of attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Fire Main › Valves
Issued 8 September 2008
Resolved
Discharge valve for fire main and sprinkler system, located with fire pump, found operable with excessive leakages. Make repairs to eliminate leakages and prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 8 September 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 8 September 2008
Resolved
Provide on board a valid SOLAS Safety Radio Certificate, Form R, Certificate of Shore Based Maintenance, and NOAA EPIRB Registration with correct call sign.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Deck/Cargo › Holds/Tanks › Coaming
Issued 8 September 2008
Resolved
Watertight automatic closing door alarm in Raceway deck, forward, portside found inoperable. Make proper repairs and prove operational readiness.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Hull › Transverse Frame
Issued 8 September 2008
Resolved
Crop and renew as original the following transverse frames; 74 Garage Deck Port, 52 Main Deck Port, 46 Main Deck Stbd, 48 Main Deck Stbd., 47 Raceway Deck Stbd (bent), 65 Upper Deck Stbd, 70 Upper Deck Stbd, 71 Main Deck Stbd, 74 Upper Deck Port.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 September 2008
Resolved
Crop and renew as original the following longitudinals; Main Deck Port between frames 46-47, Main Deck Stbd between frames 54-55.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Hull › Weld
Issued 8 September 2008
Resolved
Gouge and properly weld previous inserts on transverse frames 54, 55, and 56 Raceway Deck Stbd.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 8 September 2008
Resolved
Paint locker bulkheads and overhead found holed and wasted. Make repairs as original or replace as original to satisfaction of attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 8 September 2008
Resolved
Lube oil locker bulkheads and overhead found holed and wasted. Make repairs as original or replace as original to satisfaction of attending USCG marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 8 September 2008
Resolved
Fixed CO2 extinguishing nozzles missing in both the lube oil locker and paint locker. Replace as original to restore operational readiness.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › End Bulkhead
Issued 8 September 2008
Resolved
Replace as original the removed bulkhead bottoms for the port and starboard side of the garage or provide previous approval for removal from class/USCG.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 September 2008
Resolved
Remove doublers and properly repair/insert as original the following identified; stbd side aft of garage, port side aft of garage, emergency escape hatch port side aft of garage, emergency escape hatch stbd side aft of forecastle.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Deck Plating
Issued 8 September 2008
Resolved
Crop and renew wasted/holed deck plate in way of frame 51 raceway deck port side by rosebox.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Hull › Side Shell
Issued 8 September 2008
Resolved
Properly insert and renew as original all identified holed wasted areas of side shell plating of main deck port and starboard side. IWO frames 71-72(P), 82-83(P), 42-43(P), and 71-72(S).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 8 September 2008
Resolved
Bulwark in way of garage upper deck stbd. side found cracked. Repair as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Scuttle
Issued 8 September 2008
Resolved
Make repairs to all “gun port” and freeing port seals in order to restore weathertight integrity.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 8 September 2008
Resolved
Properly clean and eliminate leakage from vessel’s hydraulic system to include; tug/barge pin integration system, ramp rams, vehicle lifts, deck crane, etc. Install required containment to eliminate future leakage/loss of containment. Properly dispose of hydraulic oil, specifically the rosebox Tank Top Deck Stbd forward.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 16 March 2009
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 8 September 2008
Resolved
Renew weather tight integrity of all emergency and deck escape hatches.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Manhole
Issued 8 September 2008
Resolved
Properly nut and bolt all manhole access covers, specifically; forecastle port and starboard side, both covers in way of frame 51 Raceway Deck Port, cover for tank 3C Tank Top Deck Port, cover for tank 2C Tank Top Deck Port, cover Stbd aft mooring station, tug barge integration pin housing (main deck of tug) Stbd.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2008
Resolved
Replace all missing or damaged explosion proof light covers and housing for cargo deck housing.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Ventilators
Issued 8 September 2008
Resolved
Ventilation trunk for Tank Top Deck, accessible from main deck under ramp, found holed. Make proper repairs as original.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 8 September 2008
Deck/Cargo › Holds/Tanks › Weathertight Door
Issued 8 September 2008
Resolved
Emergency escape hatch coaming, port side aft CO2 room, found holed. Make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Deck Plating
Issued 8 September 2008
Resolved
Cable run stuffing missing from tubes between frames 47 & 48 Stbd main deck. Make repairs and restore weathertight integrity from upper deck.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Deck Plating
Issued 8 September 2008
Resolved
Properly cap of deck in way of removed reach rod port side forward of bosun locker.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 8 September 2008
Resolved
Properly repair electrical panel with damaged doors/securing devices, specifically; L101 Deck Lighting Panel port side forward, Lighting Panels in way of frames 44-45 port main deck, Lighting Panels in way of frames 43-44 stbd main deck, Tank Top port side aft.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Fire Hydrants › Material
Issued 8 September 2008
Resolved
Properly inspect all firefighting stations to ensure operational readiness of equipment, specifically; FS 38 Tank Top Deck frozen nozzle, broken fire axe main deck aft Stbd side, all station navy all purpose nozzles missing connecting chain from high velocity adaptor.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2008
Resolved
Properly cap off or remove dead-end cabling from deck-lights stbd. side garage deck.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2008
Resolved
Make repairs/replace as necessary all broken light bulbs, globes, and light fixtures for forecastle, bosun stores, engineers’ stores, etc.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Automatic Sprinkler System › Piping
Issued 8 September 2008
Resolved
Support brackets for fixed saltwater sprinkler system risers, Port side aft, found wasted. Make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Lighting (service) › Lighting Fixture
Issued 8 September 2008
Resolved
Repair light fixture, Tank Top Deck Port side aft, found hanging by wires.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Fire Hydrants › Material
Issued 8 September 2008
Resolved
Paint all cargo deck fresh water stations a contrasting color to red so that they are not confused with fire stations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 8 September 2008
Resolved
Remove flexible fill hose (duct taped) from vehicle elevator hydraulic system located on the Tank Top deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 September 2008
Resolved
Remove the garden hose which runs from the Stbd side aft to Port Side forward, main deck, behind electrical panels, used to fill forward head tank.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 8 September 2008
Resolved
Replace broken deck plating/grating in forward pump room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 8 September 2008
Resolved
Replace broken safety rails in forward pump room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Door
Issued 8 September 2008
Resolved
Provide securing wrench for forecastle weathertight door dogs, port and Stbd Side.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2008
Resolved
Restore proper deck light wiring on spar deck port side.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 8 September 2008
Resolved
Renew as necessary lifering man-lines and life-lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 September 2008
Resolved
Renew as original the navigation side light screens (boxes), found wasted.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Lifesaving › Inflatable Liferafts › Markings
Issued 8 September 2008
Resolved
All installed lifesaving equipment to be adequately marked with required IMO placards.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 8 September 2008
Resolved
Hazardous locations to be marked on fire control plan and submitted to the cognizant OCMI for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Lifesaving › Inflatable Liferafts › Markings
Issued 8 September 2008
Resolved
Provide means of identifying liferafts from outside of liferaft container, i.e. liferaft identification tube.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Markings › Load Line Mark
Issued 8 September 2008
Resolved
Port side deck line and seasonal marks are not permanently affixed to vessel’s hull. Seasonal marks have been pained backwards. Permanently mark as required.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Deck/Cargo › Marine Portable Tanks › Framework
Issued 8 September 2008
Resolved
Vessel is equipped with a portable diesel tank used fueling vehicles/cargo. Tank is not labeled and no documentation is available on board. Vessel to provide cognizant OCMI with prove that the tank has been inspected, is stowed, and is labeled in accordance with 49 CFR 172.101 (Hazardous Materials Table).
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 8 September 2008
Resolved
Stbd side aft horizontal roller chalk (mooring station) is frozen. Make repairs to restore operational readiness. Inspect port side aft horizontal roller chalk; make repairs as necessary to restore operational readiness.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Ventilators
Issued 8 September 2008
Resolved
Renew ventilation caps for forecastle.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Air Pipe
Issued 8 September 2008
Resolved
Supply air-line in way of electrical locker found wasted. Make proper/permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 8 September 2008
Resolved
Chain overboard discharge in pump room.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Stability › Unintentional Flooding › General
Issued 8 September 2008
Resolved
Prove proper operation of bilge pump in pump room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 16 March 2009
Fire Fighting › Means of Escape › Escape Route Signs
Issued 8 September 2008
Resolved
Label emergency escape routes in voids connected to the raceway space to allow for means of egress.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Fire Fighting › Means of Escape › Emergency Lighting
Issued 8 September 2008
Resolved
Emergency lighting throughout barge found inoperable. Vessel to carry out thorough inspection and restore operational readiness.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 September 2008
Resolved
Make proper repairs to holed bulkheads and missed welds (upper longitudinal gusset plates) in voids connected to Raceway space.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 8 September 2008
Resolved
Crop and renew horizontal stiffeners, Port and Stbd., forward in Garage, Upper Deck.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Stability › Freeing Ports › General
Issued 8 September 2008
Resolved
Clean and free all scuppers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 8 September 2008
Resolved
External audit of vessel’s safety management system to be carried out by recognized organization (RO), ABS, and report provided to cognizant OCMI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 September 2008
Resolved 2 December 2008
Deck/Cargo › Cargo Stowage › General
Issued 8 September 2008
Resolved
Vessel is directed NOT to use the crane until ABS has attended and authorized its use. See Scanned CG 835 for complete details.
Due 10 December 2008
Resolved 22 November 2009
Resolution: Wittness sat test of the deck crane.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 21 September 2007
Resolved
Sprinkler heads for the following items blocked and provided uneven coverage for cargo deck
Zone #1 PORT fwd #1, mid and aft areas
Zone #3 PORT aft areas, and fwd most sprinkler areas
Zone #6 STBD #6 sprinkler
Zone #7 STBD aft area
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 21 September 2007
Resolution: Replaced sprinkler heads and conducted sat maintenance test of blocked lines/sprinkler heads. Spray coverage sat for intended zones.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 September 2007
Resolved
Restencil and change barge name from "American" to "Mariner" on all liferings o/b vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2007
Resolved 21 September 2007
Resolution: Corrected all liferings and restenciled new vessel name "Mariner".
Electrical › Electric Supply System (service) › Cable
Issued 24 January 2007
Resolved
Numerous cables were improperly dead-ended, several light fixtures were broken. Remove all dead ended cables throughout the vessel. Repair all light fixtures and junction boxes. Remove all plastic wire ties and reattach wire w/metal straps. Make all wires, light fixtures, etc, in accordance w/46 CFR Part 111.
Due 11 July 2007
Resolved 20 September 2007
Resolution: Conducted walk through of vessel and witnessed sat repairs of electrical safety IAW 46 CFR 111.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 January 2007
Resolved
Hand rails on spar deck were wasted. Crop and renew wasted hand rails on spar de3ck just forward and starboard of crane.
Due 24 February 2007
Resolved 14 February 2007
Resolution: Handrail replaced.
Deck/Cargo › Holds/Tanks › Hatch
Issued 24 January 2007
Resolved
Watertight hatches for line lockers not sealing properly. Properly adjust watertight hatches for both port and starboard line lockers.
Due 24 February 2007
Resolved 14 February 2007
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 January 2007
Resolved
Items missing in main lighting distribution panel. Ensure main lighting distribution panel has ground fault lights and index card.
Due 24 February 2007
Resolved 14 February 2007
Resolution: Corrected.
Engineering › Fuel Oil Service System › Hose
Issued 24 January 2007
Resolved
Fuel supply and return lines are not properly fire rated. Renew both hoses.
Due 24 February 2007
Resolved 14 February 2007
Resolution: Hoses renewed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 January 2007
Resolved
Rear generator missing mounting screws for guards. Reinstall guards over machinery.
Due 24 February 2007
Resolved 14 February 2007
Resolution: Screws replaced.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 24 January 2007
Resolved
Main shore tie breaker missing, lockout device missing. Reinstall both prior to departure from Jacksonville.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: Received email/picture confirmation of breaker installation and isolator bar.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 16 March 2006
Resolved
Demonstrate proper operation of the following barge's service generator alarms and shutdowns; rpm overspeed, low lube oil pressure and high jacket water temperature.
Due 30 April 2006
Resolved 10 April 2006
Fire Fighting › Nozzles › Condition
Issued 10 March 2006
Resolved
Repair or replace all obstructed fire sprinkler nozzles to the satisfaction of an attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2006
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Piping
Issued 10 March 2006
Resolved
Repair or replace all damaged fire sprinkler branch and main lines to the satisfaction of an attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2006
Fire Fighting › Fire Main › Valves
Issued 10 March 2006
Resolved
Repair or replace the fire main cut-off reach rod and valve on the main deck aft portside to the satisfaction of an attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 March 2006
Resolved
Demonstrate the proper operation of all installed emergency lights to the satisfaction of an attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2006
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 10 March 2006
Resolved
Complete Periodic Coast Guard examination started March 8, 2006.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2006
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 March 2006
Resolved
The two Elliot, 16-person life rafts located on the upper bridge wings must be serviced.
Due 30 April 2006
Resolved 10 April 2006
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 10 March 2006
Resolved
Submit a Fire Control Pan that conforms to 46 CFR 91.55-5(d) to the Coast Guard Marine Safety Center as described in 46 CFR 91.55-15.
Due 30 April 2006
Resolved 22 January 2007
Resolution: Sector Jacksonville verified Fire Control Plan.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 10 March 2006
Resolved
Repair all exhaust and supply dampers and rolling doors to ventilators serving cargo spaces so that they fully open and close.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 15 March 2006
Fire Fighting › Automatic Sprinkler System › Piping
Issued 10 March 2006
Resolved
Demonstrate the proper operation of the entire sprinkler system to the satisfaction of an attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 10 April 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 10 March 2006
Resolved
Clean, repair or replace Ansul smoke detector number 17 so it indicates properly.
Due 30 April 2006
Resolved 15 March 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 10 March 2006
Resolved
Properly label location of Ansul smoke detector number one and two at the panel.
Due 30 April 2006
Resolved 15 March 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 March 2006
Resolved
Obtain instruction and/or service manual for the Ansul smoke detection system.
Due 30 April 2006
Resolved 10 April 2006
Fire Fighting › Fire Pumps › Gland Sealing
Issued 10 March 2006
Resolved
Repair or replace packing for fire pump #1.
Due 30 April 2006
Resolved 10 April 2006
Fire Fighting › Automatic Sprinkler System › Piping
Issued 10 March 2006
Resolved
Repair port side fire main pipe support in the bow thruster room.
Due 30 April 2006
Resolved 15 March 2006
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 March 2006
Resolved
Replaced inoperable lights in the CO2 room.
Due 30 April 2006
Resolved 15 March 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 10 March 2006
Resolved
Label the fan emergency stop in the CO2 room.
Due 30 April 2006
Resolved 15 March 2006
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 10 March 2006
Resolved
Install and/or repair hooks and gaskets as needed to ventilation covers on the upper bridge wing.
Due 30 April 2006
Resolved 15 March 2006
Fire Fighting › Ventilation Systems › Ducts
Issued 10 March 2006
Resolved
Replace missing section of battery box ventilation duct.
Due 30 April 2006
Resolved 15 March 2006
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 10 March 2006
Resolved
Install corrosion resistant lining in the battery box that conforms to 46 CFR 111.15-3(f) and (g).
Due 30 April 2006
Resolved 10 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2006
Resolved
Remove dead-end wiring from the following locations; starboard side spar deck light, port side bosun locker, main deck starboard side in way of frame 42 and spar port side flood deck. Ensure any other dead end wires found are removed.
Due 30 April 2006
Resolved 10 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2006
Resolved
Replace all missing electrical faceplates, exposed wiring plates and light fixtures.
Due 30 April 2006
Resolved 10 April 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 March 2006
Resolved
Repair bottom course in way of the starboard side spar deck light.
Due 30 April 2006
Resolved 15 March 2006
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 10 March 2006
Resolved
Provide plugs for fuel vent tank containment and ensure they fit the scupper (i.e. high fuel tank vent on spar deck).
Due 30 April 2006
Resolved 10 April 2006
Operations/Management › Vessel Safety Management
Issued 18 February 2004
Resolved
FAILURE TO SUBMIT VESSEL SESURITY ASSESSMENT. LEGACY COMPONENT DESC: Vessel Security Assessment Report
Condition: Unknown
Due 4 May 2004
Resolved 4 May 2004
Resolution: Vessel security plan received by GMSC on 20Feb2004. MISLE Activity #2011395.
Construction/Loadline › Hull › Stringer
Issued 23 December 2003
Resolved
Fwd peak is cracked and has multiple distorted stiffeners. Make permanent repairs to the collision bulkhead.
Condition: Damaged By Earlier Event
Due 24 September 2004
Resolved 31 August 2004
Engineering › Bilge Water Management System
Issued 23 December 2003
Resolved
Provide a means to operate from a position above the freeboard deck all applicable machinery inlet and discharges. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 12 February 2004
Resolved 14 January 2004
Resolution: Witnessed satisfactory operation.
Engineering › Bilge Water Management System
Issued 23 December 2003
Resolved
Remove the direct overboard connection on the port side of the forward machinery space, this allows the OWS to discharge Oily water dircetly overboard via a permanently installed hull fitting. LEGACY COMPONENT DESC: Piping
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2004
Construction/Loadline › Hull
Issued 8 December 2003
Resolved
Provide repair proposal that includes all repairs, renewals, and modifications associated with the structural damage sustained on december 9, 2002. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2003
Construction/Loadline › Structures
Issued 8 December 2003
Resolved
Provide assessment of the repair proposals effect on the vessels stability. LEGACY COMPONENT DESC: Superstructure
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2003
Stability › Intact Righting Energy
Issued 8 December 2003
Resolved
Provide report from ABS that verifies the integrity and the adeguacy of freeing ports, watertight and weathertight doors and hatches throughtout the barge. Demonstrate proper operation of same to the CG.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 January 2004
Resolution: All freeing ports and doors have been adressed, ABS endorsed L/L document.
Fire Fighting › Fixed Fire Detection System
Issued 8 December 2003
Resolved
Cargo hold smoke detector system inoperable, demonstrate proper operation of the same.. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2004
Resolution: System repaired and tested satisfactorily.
Fire Fighting › Ventilation Systems
Issued 8 December 2003
Resolved
Multiple cargo hold ventilation dampers inoperable, demonstrate proper operation of the same. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2004
Resolution: All dampers operate satisfactorly.
Fire Fighting › Fire Main
Issued 8 December 2003
Resolved
Multiple valves to sprinkler system inoperable and multiple sprinkler heads missing, renew as required and demonstrate proper operation of system. LEGACY COMPONENT DESC: Valves
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2004
Resolution: Witnessed satisfactory operation of system in multilple zones.
Fire Fighting › Combustible Materials
Issued 8 December 2003
Resolved
Flammable liguids and paints stowed in container on weather deck. Remove flammables or outfit container with fixed system and portable extinguihers. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2004
Resolution: Installed CO2 systems in containers.
Stability › Intact Stability (when using lifting gear)
Issued 8 December 2003
Resolved
Provide evidence from ABS that the barge is in compliance with the required stability criteria after accounting for the crane and any structural steel added to the barge since the last stability test conducted on december 13, 1981
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 December 2003
Resolved 18 December 2003
Construction/Loadline › Structures
Issued 8 December 2003
Resolved
Provide plans and specifications for permanently installed ring crane approved by either a recognized class society or a recognized cargo gear organization, and provide documentation regarding the date of installation.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 January 2004
Resolution: Found documentation from ABS that structural specifications have been met, see ABS certificate HS23027 dated 23 OCT 97.
Fire Fighting › Fire Main
Issued 2 December 2003
Resolved
multiple fire main system cut out valves inoperative, demonstrate proper operation of the same. LEGACY COMPONENT DESC: Valves
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 January 2004
Resolution: Operated valves, satisfactory.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 2 December 2003
Resolved
Fire control plan is not approved or up to date. Make changes reccommended on plans, provide fire control plan for approval. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 31 August 2004
Stability
Issued 2 December 2003
Resolved
Provide evidence from ABS that stability loading program being used has been reviewed and is acceptable for use on the barge.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 April 2004
Operations/Management
Issued 2 December 2003
Resolved
Material condition of barge , inop sprinkler sys, inop fire dampers, inop ventillation, watertight integrity issues, vessel is to be conduct a full Reinspection to asses seaworthiness prior to departure from port.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2004
Resolution: Completed RIN.
Deck/Cargo › Cargo Stowage
Issued 2 December 2003
Resolved
Provide CG approved plan(s) that demonstrate the main deck ventilation system complies with the applicable requirements necessary for the carriage of vehicles.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2004
Deck/Cargo › Cargo Stowage
Issued 2 December 2003
Resolved
Provide CG approved plan(s) that demonstrate the electrical installations on this deck comply with the applicable requirements necessary for the carriage of vehicles.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2004
Deck/Cargo › Cargo Stowage › General
Issued 2 December 2003
No resolution recorded
Provide a CG approved arraingment plan identifying the hazardous cargoes and non-hazardous areas, cargo system or hazards, electrical equipment type and locations. provide an independent laboratory label or listing for all explosion-proof and intrinsically safe equipment and systems.
Condition: Unknown
Due 24 September 2004 — due date passed with no resolution recorded
Resolution: Requirement rescinded on January 13, 2005. See MISLE Act.
Deck/Cargo › Cargo Stowage › General
Issued 2 December 2003
Resolved
Remove the inoperable installed carbon monoxide monitoring system. provide evidence that the rquired tests and logs were completed during the last vehicle cargo operation completed before December 1, 2003
Condition: Unknown
Due 12 February 2004
Resolved 31 August 2004
Engineering › Fuel Oil Storage/Transfer System
Issued 14 January 2003
Resolved
Repair reach rods to fuel tanks for barge generators. LEGACY COMPONENT DESC: Valve
Condition: Damaged By Earlier Event
Due 18 February 2003
Resolved 28 March 2003
Resolution: Witnessed Satisfactory operation.
Pollution Prevention/Response › Prevention Equipment
Issued 14 January 2003
Resolved
Provide proper standard discharge connection on oil discharge piping. LEGACY COMPONENT DESC: Standard Discharge Connection
Due 18 February 2003
Resolved 26 March 2003
Pollution Prevention/Response › Prevention Equipment
Issued 12 November 2002
Resolved
Install required piping to pump bilge waste to a shore facility with an international Shore connection. As required by 33 CFR 155.360 and 33 CFR 155.430. Note: company has requested exemption from this requirement in a letter sent to G-MOC dated 22 November 02. LEGACY COMPONENT DESC: Standard Discharge Connection
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 January 2003
Resolved 18 January 2003
Resolution: Examined satisfactory installation.
Deck/Cargo › Cargo Transfer (solid)
Issued 12 November 2002
Resolved
Have cargo gear tested and provide Certificate LEGACY COMPONENT DESC: Crane
Condition: Unknown
Due 30 December 2002
Resolved 18 January 2003
Resolution: Provided certificates.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 November 2002
Resolved
Have Oil Transfer hose Hydroed LEGACY COMPONENT DESC: Transfer Hose
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 23 November 2002
Resolution: Pressure tested to 225 psi.
Accommodation/Occupational Safety › Ventilation
Issued 12 November 2002
Resolved
All deck vents need dogs reworked or replaced and new gasket material around knife-edges. LEGACY COMPONENT DESC: Deck Vents
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 25 November 2002
Construction/Loadline › Penetrations
Issued 12 November 2002
Resolved
Repair overhead hatch in Dry stores room (Aft portside) Hatch is missing dogging arm. LEGACY COMPONENT DESC: Deck Hatch
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 25 November 2002
Pollution Prevention/Response › Prevention Equipment
Issued 12 November 2002
Resolved
Remove fuel from fuel transfer pump room and have bilges cleaned LEGACY COMPONENT DESC: Fuel Transfer room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 7 January 2003
Resolution: Sited satisfactory clean-up.
Electrical › Electrical Distribution System (service)
Issued 12 November 2002
Resolved
Repair/ Replace motor controller on portside in fuel pump room. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 25 November 2002
Operations/Management › Dedicated Clean Ballast Tanks
Issued 12 November 2002
Resolved
Extend Sounding tube for #7 Ballast tank to Main deck to prevent crew members from entering confined space to sound ballast tank. LEGACY COMPONENT DESC: Flushing Pump/Piping System
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 7 January 2003
Resolution: Examined satisfactory installation.
Construction/Loadline › Penetrations
Issued 12 November 2002
Resolved
Repair deck hatch to battery room. Handle on hatch is inop. LEGACY COMPONENT DESC: Deck Hatch
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 25 November 2002
Fire Fighting › Fire Main
Issued 12 November 2002
Resolved
Replace firemain-piping elbow at #6 fire station and at #8 fire station. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 7 January 2003
Resolution: Examined satisfactory repairs.
Electrical › Lighting (service)
Issued 12 November 2002
Resolved
Provide light covers for all lights in FWD Electrical room. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 29 January 2003
Resolution: repaired
Electrical › Electrical Distribution System (service)
Issued 12 November 2002
Resolved
Repair/Replace breaker panel covers on panels located in way of frame #72 on main deck. Label all breaker panels on barge LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Improper/Lack of Maintenance
Due 13 December 2002
Resolved 25 November 2002
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 12 November 2002
Resolved
Repair damage Sprinkler system in Cargo hold on Upper deck. LEGACY COMPONENT DESC: Piping
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 7 January 2003
Resolution: Examined satisfactory repairs.
Electrical › Electric Generation Source (service)
Issued 12 November 2002
Resolved
Prove generator installation is in accordance with 46 CFR 111.12-11. Generators need reverse power protection or a secure way to prevent electrical back feed to the Tug gen or vis versa. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 7 January 2003
Resolution: Witnessed satisfactory test.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 12 November 2002
Resolved
Repair/Replace Generator lube oil shut down and prove proper operation. LEGACY COMPONENT DESC: Alarms Circut
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 December 2002
Resolved 7 January 2003
Resolution: Witnessed satisfactory test.
Fire Fighting
Issued 21 September 2001
Resolved
PROVE PROPER OPERATION OF WATER SPRAY SYSTEM ON THE MAIN AND UPPER DECKS.
Condition: Unknown
Due 28 February 2002
Resolved 16 January 2002
Resolution: WITNESSED SAT TEST OF THE WATER SPRAY SYSTEM ON THE MAIN AND UPPER DECKS.
Electrical
Issued 21 September 2001
Resolved
PROVE PROPER OPERATION OF GENERATOR LOW LUBE OIL AND HIGH JACKET WATER TEMPSHUTDOWNS.LOW LUBE OIL AND HIGH JACKET WATER TEMP SHUTDOWNS.
Condition: Unknown
Due 24 September 2001
Resolved 24 September 2001
Lifesaving
Issued 4 December 2000
Resolved
Ensure all bare/exposed electrical wires in the generator/bow thruster roomare properly ended or removed
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 4 December 2000
Resolved
Ensure all bare/exposed electrical wires in the fuel pump room are properlyended or removed
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 4 December 2000
Resolved
Ensure all light are properly shieled and are installed properly.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Electrical
Issued 4 December 2000
Resolved
Ensure all electrical panels are properly enclosed.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 4 December 2000
Resolved
Ensure all emergency escape hatches are not locked or tied down while personnel are onboard.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Engineering
Issued 4 December 2000
Resolved
Ensure all fuel vent containment trunks have proper mechanical plugs.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Fire Fighting
Issued 4 December 2000
Resolved
Ensure all fire stations have properly operating fire nozzels and have spanner wrenches
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 4 December 2000
Resolved
Remove oil from sump lower level lift by hydraulic ram.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 4 December 2000
Resolved
Ensure all life rings are on board and in serviceable condition as per the barge fire safety plan.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Engineering
Issued 4 December 2000
Resolved
Provide hydrostatic test report for fuel oil transfer hose.
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Documentation
Issued 4 December 2000
Resolved
Oily Water Separator,15ppm alarm and oil content meter did not properly operate. Following equipment listed on IOPP Cert. was innacurate or missingaboard the barge: #5 center sludge tank is a diesel tank with no sludge piping. No standard discharge connection due to no piping to a sludge tank.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 4 December 2000
Resolved
Remove excessive oil from bilge in the fuel pump room
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Fire Fighting
Issued 4 December 2000
Resolved
Ensure Fire Safety Plan is up to date and properly mounted.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Fire Fighting
Issued 4 December 2000
Resolved
Provide international shore connection as per Fire Safety Plan
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Documentation
Issued 4 December 2000
Resolved
Provide piping line diagram for Oil Transfer Procedures.
Condition: Unknown
Due 9 January 2001
Resolved 9 January 2001
Construction/Loadline
Issued 1 October 1998
Resolved
PRIOR TO DEPARTING HOUSTON/GALVESTON COTP ZONE, PROVIDE OPERABLE OILY WATERSEPERATOR IAW MARPOL 73/78 AND 33 CFR 155.380.
Condition: Unknown
Due 6 October 1998
Resolved 8 October 1998
Unknown
Issued 5 December 1997
Resolved
PROVE PROPER OPERATION OF CO DETECTION SYSTEM IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PRIOR TO LOADING CARGO IN ENCLOSED SPACES. NO CO PRODUCING MACHINERY IS TO BE OPERATED BELOW THE MAIN DECK.
Condition: Unknown
Due 5 December 1997
Resolved 5 December 1997
Deck/Cargo
Issued 30 September 1997
Resolved
Prove proper operation of carbon monoxide detection system in presence of Coast Guard Marine Inspector prior to loading cargo. No machinery producing carbon monoxide is to be operated below deck.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Fire Fighting
Issued 30 September 1997
Resolved
Make all fire stations ready for operation to include attaching hoses, nozzles and spanner wrenches prior to loading of cargo.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Fire Fighting
Issued 30 September 1997
Resolved
Provide vessel fire control plan prior to loading cargo.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Electrical
Issued 30 September 1997
Resolved
Permanently affix electrical cable from battery box to engine and install guard to protect electrical cable IAW IEEE 45.20.4.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Unknown
Issued 30 September 1997
Resolved
Prove proper operation of Auto Bar Unit in presence of Coast Guard Marine Inspector upon arrival to Houston, TX.
Condition: Unknown
Due 30 September 1997
Resolved 30 September 1997
Electrical
Issued 30 September 1997
Resolved
Lable following circuit breaker boxes with appropriate locations for each breaker; 6L101, 5L114, 5L101, 6L101, 5P101, P101._x001C_
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Electrical
Issued 30 September 1997
Resolved
Install emergency lighting, port and starboard exit from aft pump room.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Electrical
Issued 7 December 1992
Resolved
Repair/remove damaged power cable in bow visor/ramp.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Construction/Loadline
Issued 7 February 1992
Resolved
MAKE PERMANENT REPAIRS, AS ORIGINAL TO STOPS, IN WAY OF TUGS CONNECTING SYSTEM. (ARMS) RE-CONNECT AU;TOMATICD LUBRICATION ON STARBOARD SYSTEM. TO BE COMPLETED PRIOR TO DEPARTURE FROM OAKLAND, CA, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR._x001C_
Condition: Unknown
Due 11 February 1992
Resolved 16 March 1992
Fire Fighting
Issued 7 February 1992
Resolved
RE-CONNECT TOWBOAT/BARGE FIRE MAIN BRACKET, STB SIDE TOWBOAT. ITEM TO BE COMPLETED PRIOR TO DEPARTURE FROM OAKLAND, CA, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 February 1992
Resolved 16 March 1992
Electrical
Issued 4 December 1990
Resolved
REPAIR OR RENEW CONTROLLER FOR VENT SUPPLY FAN, #1 ONLY OPERATES ON SLOW SPEED.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Electrical
Issued 4 December 1990
Resolved
REPAIR OR RENEW COIL FOR ATUOTRANSFER OF EMERGENCY LIGHTS - EMERGENCY LIGHTS SHALL BE LEFT ON UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Fire Fighting
Issued 4 December 1990
Resolved
REPAIR SMOKE DETECTION CABINET AND PROVE OPERATION PRIOR TO LOADING BARGE
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Electrical
Issued 4 December 1990
Resolved
REPAIR LIGHT AT TOP OF RAMP ON SPAR DECK
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Electrical
Issued 4 December 1990
Resolved
REPAIR SPOT LIGHTS ON MAINDECK LEVEL AFT PORT AND STARBOARD SIDE OVER WINCHES.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Engineering
Issued 4 December 1990
Resolved
HYDROSTATICALLY TEST OIL TRANSFER HOSE TO 1.5 MAWP. DO NOT USE UNITL CORRECTED.
Condition: Unknown
Due 4 December 1990
Resolved 4 December 1990
Navigation
Issued 21 January 1988
Resolved
DISCONNECT AND REMOVE OR PROPERLY DEMONSTRATE TVG/BARGE MOG SYSTEM (RADIO CONTROL).
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
IAW MSA SERVICE REPORT, SUBMIT PROPOSAL TO OCMI HAMPTON ROADS ON RELOCATIONOF CARBON MONOXIDE SAMPLE POINTS. MSA SERVICE REPORT RECOMMENDS SAMPLE POINTS BE FIVE FEET OFF DECK.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Construction/Loadline
Issued 21 January 1988
Resolved
INSTALL MISSING SWING CHECK DISKS AND HINGE PINS IN OVERBOARD SCUPPER LINE IN WAY OF CAR DECK STARBOARD SIDE ADJACENT TO FORWARD CAR RAMP.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Fire Fighting
Issued 21 January 1988
Resolved
INSTALL TOGGLE KEEPER PINS ON FIRE DAMPERS THROUGHOUT VESSEL.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Electrical
Issued 21 January 1988
Resolved
REPAIR OR RENEW TRANSFORMER FOR CARGO VENTILATION FAN #16.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Electrical
Issued 21 January 1988
Resolved
REPAIR OR RENEW CONTROLLER FOR VENT SUPPLY FAN #1 (OPERATES ON SLOW SPEED ONLY).
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Electrical
Issued 21 January 1988
Resolved
CLEAR ELECTRICAL GROUNDS FROM VESSEL'S ELECTRICAL SYSTEM AND DEMONSTRATE PROPER OPERATION OF GROUND DETECTION SYSTEM ON SWITCHBOARD.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Documentation
Issued 21 January 1988
Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR REVIEW (CURRENT PROCEDURE NOT IN PROPER FORMAT) IAW 33 CFR 155.750.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
INSTALL NEW HYDRAULIC HOSES (AS ORIGINAL) ON BOW VISOR, CAR RAMPS, ELEVATORSIDE RAMPS, ETC AND CONDUCT OPERATIONAL TEST OF SAME. NEW HOSES TO BE SO INSTALLED AS TO PREVENT FURTHER CHAFFING.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
INSTALL CHAIN AND STANCHION BARRIER ON EACH END OF MAIN DECK ELEVATOR TO PREVENT ACCESS TO AREA WHEN ELEVATOR IS IN OPERATION.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Documentation
Issued 21 January 1988
Resolved
COMPLETE CREDIT DRYDOCK NOT LATER THAN 29 FEB 88.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Construction/Loadline
Issued 21 January 1988
Resolved
MARK ALL EXCAPE LADDERS FROM CAR AND TRAILER DECKS (EMERGENCY ESCAPE) IN CONTRASTING COLORS, MINIMUM OF 3 INCH LETTERS.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Fire Fighting
Issued 21 January 1988
Resolved
MARK SPRINKLER MANIFOLD TO IDENTIFY VALVES IN RELATION TO THE ZONE CONTROLLED.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Engineering
Issued 21 January 1988
Resolved
INSTALL DRAINS AND PLUGS IN FIXED CONTAINMENT UNDER FUEL OIL MANIFOLDS PORT AND STARBOARD SIDE OF BARGE
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Construction/Loadline
Issued 21 January 1988
Resolved
MARK HAILING PORT ON VESSEL IAW 46 CFR 67.15-3; OLD HAILING PORT (MIAMI, FL) TO BE GROUND OFF HULL.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
PROVIDE CO SPAN GAS AND INSTALL FOR VESSEL'S CARBON MONOXIDE SENSING SYSTEM.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
PROVIDE/INSTALL NEW RELAY IN CIRCUIT 41 CENTERLINE FOR VESSELS CARBON MONOXIDE SENSING SYSTEM.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
INSTALL FIXED CONTAINMENT UNDER IMO STANDARD DISCHARGE CONNECTIONS (PORT AND STBD IAW 33 CFR 155. UNTIL SUCH TIME FIXED CONTAINMENT IS INSTALLED, PROVIDE PORTABLE CONTAINMENT (5 GAL BUCKETS)
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Documentation
Issued 21 January 1988
Resolved
PROVIDE CERTIFICATE OF FINANCIAL RESPONSIBILIY FOR REVIEW BY OCMI HAMPTON ROADS.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Electrical
Issued 21 January 1988
Resolved
ENSURE ALL ELECTRICAL JURY RIGS ARE REMOVED. ALL ELECTRICAL PANEL BOXES WIRING, ETC ARE TO BE IN ACCORDANCE WITH 46 CFR SUBCHAPTER J.
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988