Records from 1985 to 1998. Most recent: inspection, 15 February 1998.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
15 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 412905
20 November 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 453407
28 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 332281
26 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 330603
10 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 515726
6 September 1987
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 318284
22 October 1986
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 312257
21 August 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 515984
Fire Fighting › Fire Main › Pressure
Issued 15 February 1998
Resolved
FIX EMERGENCY FIRE PUMP GAUGE TO SATISFACTION OF CLASS SOCIETY. PROVIDE LOCAL COAST GUARD WITH SATISFACTORY SURVEYOR'S REPORT.
Condition: Unknown
Due 16 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 15 February 1998
Resolved
FIX SMALL HOLE IN #4 FUEL STBD VENT CONTAINMENT. MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 16 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Construction/Loadline › Markings › Load Line Mark
Issued 15 February 1998
Resolved
MAKE LOADLINE PERMANENT AND PAINT CONTRASTING COLOR. PROVIDE LOCAL COAST GUARD WITH COPY OF SATISFACTORY CLASS SOCIETY SURVEYOR'S REPORT.
Condition: Unknown
Due 16 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 15 February 1998
Resolved
PROVIDE ON BOARD COPY OF TIDAL CURRENT TABLES.
Condition: Unknown
Due 16 February 1998
Resolved 28 September 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Lifesaving › Lifeboat Equipment › Hand Flare
Issued 15 February 1998
Resolved
PROVIDE TEST DATE OR EXPIRATION DATE FOR HYDROSTATIC RELEASE UNIT FOR EPIRB. PROVIDE COPY OF REPORT FROM MANUFACTURER OR SERVICING TECHNICIAN.
Condition: Unknown
Due 16 February 1998
Resolved 5 October 2004
Resolution: 05OCT04: Due to age of requirement cleared deficiency to clean up Sector San [name withheld] Deficiencies List.
Navigation
Issued 28 August 1989
Resolved
33CFR164.35(I) VESSEL'S ECHO DEPTH SOUNDER RECORDING SOUNDER DEVICE WAS MISSING. AUTH: 33USC1223 PENALTY: 33USC1232
Condition: Unknown
Due 28 August 1989
Resolved 28 August 1989
Navigation
Issued 26 May 1989
Resolved
VESSEL FAILED TO HAVE A CURRENTLY CORRECTED COPY OR APPLICABLE EXTRACT OF THE TIDAL CURRENT TABLE ONBOARD. 33 CFR 164.33 (A) (3)
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Navigation
Issued 26 May 1989
Resolved
33 CFR 164.33 (I). VESSEL'S ECHO DEPTH SOUNDING RECORDING DEVICE WAS INOPERATIVE UPON INSPECTION OF THE BRIDGE.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Navigation
Issued 26 May 1989
Resolved
33 CFR 164.41 (A). VESSEL OVER 1600 GROSS TONS OPERATING IN U.S. WATERS WITHOUT AN OPERABLE ELECTRONIC POSITION FIXING DEVICE.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Navigation
Issued 26 May 1989
Resolved
33 CFR 164.35 (H0. VESSEL'S ECHO DEPTH SOUNDER DEVICE WAS INOPERATIVE UPON INSPECTION OF THE BRIDGE.
Condition: Unknown
Due 26 May 1989
Resolved 26 May 1989
Unknown
Issued 26 May 1989
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Deck/Cargo
Issued 26 May 1989
Resolved
INSPECTOR OBSERVED THAT THE DANGEROUS CARGO MANIFEST(DCM) WAS NOT FILLED OUT PROPERLY AS PROVIDED BY 46 CFR 148.02-3 (A).
Condition: Unknown
Due 19 February 1998
Resolved 19 February 1998
Navigation
Issued 6 September 1987
Resolved
VESSEL'S ECHO DEPTH SOUNDER WAS INOPERATIVE.
Condition: Unknown
Due 6 September 1987
Resolved 6 September 1987
Documentation
Issued 22 October 1986
Resolved
THE PROPER SHIPPING NAME REQUIRED BY 49 CFR 176.30(A)(3) WAS IMPROPERLY LISTED ON THE DANGEROUS CARGO MANIFEST.
Condition: Unknown
Due 24 October 1986
Resolved 22 October 1986
Documentation
Issued 22 October 1986
Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT HAVE LOCATION OF CARGO LISTED ON THE MANIFEST AS REQUIRED BY 49 CFR 176.30(A)(7).
Condition: Unknown
Due 24 October 1986
Resolved 22 October 1986
Documentation
Issued 22 October 1986
Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT HAVE THE OFFICIAL NUMBER OR CALL SIGN ON THE MANIFEST AS REQUIRED BY 49 CFR 176.30(A)(1)
Condition: Unknown
Due 24 October 1986
Resolved 22 October 1986
Documentation
Issued 22 October 1986
Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT HAVE THE NATIONALITY OF THE VESSEL LISTED ON THE MANIFEST AS REQUIRED BY 49 CFR 176.30(A)(2)
Condition: Unknown
Due 24 October 1986
Resolved 22 October 1986