MAURY USCG vessel records Sign in
← All vessels

GREETSIEL

GREETSIEL is a 1999 freight ship. The Coast Guard has recorded 27 inspections since 2000, most recently in January 2011, along with 8 deficiencies and 2 operational controls.

Records from 2000 to 2011. Most recent: inspection, 11 January 2011.

Built
1999
Last inspected
11 January 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9208693 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-2469

Inspections, by type

…with no type recorded15
Years with a record 11 calendar years (2000–2011)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it4752 - Dead Weight, Ton
4450 - Regulatory (Subpart C or D), Gross Ton
2141 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

11 January 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3924598
22 April 2009 MARPOL Annex II Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3458009
8 April 2008 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3178792
25 April 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2915717
25 April 2007 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2915728
24 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2914268
11 April 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2906035
27 March 2007 ISPS II Exam · MARPOL Annex V Examination · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2894979
14 March 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2602233
13 January 2005 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2274104
14 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2240623
24 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2142997
21 June 2004 PII Safety Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2105741
28 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2055775
27 April 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2054889
4 February 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2000176
3 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2000982
19 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1797008
20 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1776942
24 March 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1761968
22 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1761190
21 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1760991
30 November 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1712405
4 November 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1700685
27 November 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 295763
10 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 291827
19 March 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 275912

Deficiency record · 8

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 11 January 2011 Resolved
1730 Oily water separating equipment: oil filtering equipment shall be of a design approved by the administration and shall be such as will ensure that any oily water mixture through the system will not exceed 15 PPM. Found filtering equipment to be working intermittently due to pump motor occasionally becoming stuck. MARPOL (2006 Cons Ed) Annex 1 Reg 14.1 and 14.6.
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 21 March 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 January 2011 Resolved
0999 Other (Safety in general): Main and emergency switchboards shall be so arranged as to give easy access, without danger to personnel. Non conductive mat or grating shall be provided at the front and rear of the switchboard. Emergency generator switchboard has not mat or grating. 74 SOLAS (2004 Cons Ed) II-1 Reg 45.2.
Action required: 705 - Other - as specified
Due 11 January 2011
Resolved 11 January 2011
Resolution: Corrected to the satisfaction of CG prior to exam conclusion.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 11 January 2011 Resolved
0750 Fire prevention: The construction of all doors in "A" class divisions, with means of securing them when closed, shall provide resistance to fire as well as to passage of smoke and flame. During the fire drill exercise, observed galley door open on its own after being closed by vessel's crewmember. After drill, rechecked and confirmed door would not remain closed. 97 SOLAS II-2 Reg 30.2
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 21 March 2011
Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 27 March 2007 Resolved
02 CO2 cylinders need to be replaced due to rusted and worn threads on heads. Cylinders will need to be replaced. Need class report attesting to repairs and condition of CO2 room.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 11 April 2007
Lifesaving › Lifeboat › Markings
Issued 27 March 2007 Resolved
Retro Reflective Tape on Free Fall Lifeboat is worn and tattered.
Action required: 705 - Other - as specified
Due 27 April 2007
Resolved 11 April 2007
Deck/Cargo › Cargo Stowage › General
Issued 14 March 2006 Resolved
Flammable liquid (gasoline) is stored in the rescue boat gear locker.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 15 March 2006
Resolution: Def cleared due to Class report of re storage of Gasoline
Electrical
Issued 10 July 2001 Resolved
Have class address the installation of the portable welder in the emergencygenerator room.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Documentation
Issued 10 July 2001 Resolved
Provide complete oil transfer procedures to include diagram and instructions for internal transfers of waste oil.
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.