MAURY USCG vessel records Sign in
← All vessels

TEAM EFFORT

TEAM EFFORT is a 1984 freight ship. The Coast Guard has recorded 25 inspections since 1985, most recently in December 2007, along with 11 deficiencies and 2 operational controls, 1 with no removal date recorded.

Records from 1985 to 2007. Most recent: inspection, 10 December 2007.

Built
1984
Last inspected
10 December 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8308886 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
246922
Flag
LIBERIA
—
Maury page id
psix-246922

Inspections, by type

…with no type recorded20
Years with a record 16 calendar years (1985–2007)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it37744 - Dead Weight, Ton
45232 - Displacement, Ton
22531 - Convention (Subpart B), Gross Ton
12548 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

10 December 2007 ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3110521
22 June 2006 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2688360
16 June 2006 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2680989
4 October 2005 Deficiency Check · ISPS III Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2507024
30 November 2004 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2250779
12 July 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 291875
2 August 1999 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 431143
15 March 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 426624
17 February 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 425487
3 June 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 417290
18 April 1996 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 391205
17 July 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 368543
22 June 1994 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 368019
11 January 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 539184
9 June 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 358926
18 March 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 342457
21 December 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 334245
27 April 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 521324
15 September 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 325589
10 June 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 316693
12 November 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 312563
3 November 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 494183
14 May 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 308820
17 November 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 508504
26 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 300755

Deficiency record · 11

Fire Fighting › Fire Hoses › Condition
Issued 16 June 2006 Resolved
Four fire hoses were found to have several holes and were unable to hold pressure. Replace prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2006
Resolution: Fire Hoses replaced prior to departure.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 16 June 2006 Resolved
The fire plan is not accurate to the vessel's layout. A locker is shown where there is actually a passageway to an external door. Address to the satisfaction of class society.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 June 2006
Resolution: Received Class report stating that the FCP has been amended and endorsed.
Lifesaving › Lifeboat › Lifeline (becketed)
Issued 16 June 2006 Resolved
The becketed lifeline on the starboard lifeboat has wasted bolts, causing the line to break free from the hull. Address to the satisfaction of class society.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 June 2006
Resolution: Received Class report stating that lifelines have been repaired and considered satisfactory
Lifesaving › Lifeboat › Canopy
Issued 16 June 2006 Resolved
Both lifeboats do not have appropriate canopy covers for occupant protection. The vessel has a canvas cover that is meant to protect the boat (for storage) but is not the appropriate size/setup/specs to be rigged should the boat need to be used. Vessel is unable to arrange for covers in this port; must be addressed by flag state rep/class society at next port.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 22 June 2006
Resolution: Received Class report stating that the canopy covers were examined and considered satisfactory.
Lifesaving › Rocket Parachute Flares › General
Issued 4 October 2005 Resolved
Vessel did not have the required number of parachute flares onboard the bridge. The bridge was short 03 parachute flares.
Action required: 705 - Other - as specified
Due 6 October 2005
Resolved 4 October 2005
Resolution: Received fax from agent showing that the 03 parachute flares had been ordered.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 6 December 2004 Resolved
Suspected unauthorized OWS operation with possible bypass. Oily residue found in OWS discharge piping. Refit piping to reflect diagram in oil record book, to the satisfaction of class.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 December 2004
Resolution: VESSELS CREW RE-PIPED OWS AND THE ABS SURVEYOR SUBMITTED A REPORT ATTESTING TO THE PROPER ASSEMBLY AND OPERATION OF THE OWS.
Navigation
Issued 9 June 1993 Resolved
CHARTS #12333, 12334, NOT ON BOARD. NO OTHER EQUIVALENT AVAILABLE.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Navigation
Issued 15 September 1988 Resolved
CHART 18751 ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 18 September 1988
Resolved 15 September 1988
Navigation
Issued 15 September 1988 Resolved
NO TIDAL CURRENT TABLES ONBOARD AS REQUIRED BY 33CFR164.33.
Condition: Unknown
Due 18 September 1988
Resolved 15 September 1988
Navigation
Issued 10 June 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO VANCOUVER ANCHORAGE WITHOUT HAVING ONBOARD A COPY OF THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 24 June 1987
Resolved 10 June 1987
Navigation
Issued 10 June 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO VANCOUVER ANCHORAGE WITHOUT HAVING ONBOARD A LIGHT LIST OF THE AREA NAVIGATED CURRENTLY CORRECTED UP TO DATE.
Condition: Unknown
Due 24 June 1987
Resolved 10 June 1987

Ownership record