MAURY USCG vessel records Sign in
← All vessels

ZAPOTECA

ZAPOTECA is a 1984 freight ship. The Coast Guard has recorded 32 inspections since 1985, most recently in April 2005, along with 50 deficiencies and 6 operational controls.

Records from 1985 to 2005. Most recent: inspection, 23 April 2005.

Built
1984
Last inspected
23 April 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8310865 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
246976
Flag
LIBERIA
—
Maury page id
psix-246976

Inspections, by type

…with no type recorded17
Years with a record 13 calendar years (1985–2005)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10383 - Regulatory (Subpart C or D), Gross Ton
12680 - Dead Weight, Ton
18770 - Displacement, Ton
5584 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

23 April 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2341286
13 April 2005 Re-Inspection · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2332741
28 February 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2300564
17 February 2005 PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2294692
7 February 2005 ISPS I Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2287696
5 February 2005 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2287132
14 November 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2240591
26 January 2004 Periodic Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1992947
22 January 2004 Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1990264
16 July 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1854222
12 May 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1792895
28 March 2003 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1763226
14 August 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1661221
14 August 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1661279
9 June 2002 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1628090
30 March 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1496164
8 October 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1074314
10 January 2001 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 825048
25 September 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 282580
9 March 2000 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 815448
30 November 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 435188
26 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 85985
26 July 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418702
22 April 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415055
25 May 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337339
23 February 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 437687
20 February 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 498960
31 August 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 332350
3 August 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 317665
2 December 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 449002
24 July 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 310383
4 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 300767

Deficiency record · 50

Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 13 April 2005 Resolved
Vessels Safe Manning Certificate does not address required number of radio officers and/or GMDSS certificate holders. Cite:STCW 95
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 28 April 2005
Resolution: Recieved fax copy of new certificate issued by Flag State, Thailand, addressing the required number of radio officers and/or GMDSS certificate holders.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 17 February 2005 Resolved
Fire doors on interior stairway do not properly close. Demonstrate proper operation of fire doors to the satisfaction of the safety construction certificate issuing authority prior to departure. SOLAS 74 (U) II-2/51
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Engineering › Steering Gear System › Power Unit
Issued 17 February 2005 Resolved
The loss of power alarm for the steering gear is not functioning properly. Repair to the satisfaction of the safety construction certificate issuing authority prior to departure. SOLAS 74 (A) I/11 (a)
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Engineering › Steering Gear System › Pump
Issued 17 February 2005 Resolved
The #2 steering pump has excessive leaks. Repair to the satisfaction of the safety construction certificate issuing authority prior to departure.
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 February 2005 Resolved
The MDE fuel oil system leaks excessively (delivery pump, service pump, service tank connections). Clean and repair to the satisfaction of the safety construction certificate issuing authority prior to departure. SOLAS 74(a) I/11(a)
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 17 February 2005 Resolved
Numerous oil leaks were observed on the MDE. Clean and repair leaks to the satisfaction of the vessel's safety equipment issuing authority prior to departure. SOLAS 74 (a) I/11 (a)
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 17 February 2005 Resolved
The echo depth sounder recording device does not function properly. Provide service technician's report verifying proper operation of the recording device to USCG. 33CFR164.35(i).
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of USCG.
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 17 February 2005 Resolved
Vessel's operator provided a notice of arrival that did not disclose the failure of the echo depth sounder recording device to function properly. Provide a letter of undertaking in the amount of $32,500 to USCG MSO Houston-Galveston prior to departure. 33CFR160.206(a)
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of USCG.
Lifesaving › Lifeboat › Propulsion Engine
Issued 17 February 2005 Resolved
The starboard lifeboat does not readily start (requires jumper cables). Repair to the satisfaction of the safety equipment certificate issuing authority prior to departure.
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 17 February 2005 Resolved
Based on defs 3,4,5,6,7 & 8 clear grounds exist as to the vsl's failure to comply with it's SMS, in particular with S-703 maintenance procedures for important machinery & equipment and S-0701cq procedures for completing the monthly safety equip checklist. Provide verification from the organization that issued the DOC & SMC that the vsl's SMS is adequate and is properly implemented. SOLAS IX/5.
Action required: 705 - Other - as specified
Due 18 February 2005
Resolved 20 February 2005
Resolution: Corrected to the satisfaction of the certificate issuing authority.
Documentation › Certificates/Documents
Issued 26 January 2004 Resolved
Certificate of Registration not onboard, Master stated that original was with agent.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2004
Resolution: Copy of registration was fax to office.
Fire Fighting › Self-contained Breathing Apparatus
Issued 26 January 2004 Resolved
Vessel's EEBD's were stored in the original shipping boxes and not ready for immediate use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2004
Resolution: EEBD''s removed from boxes while onboard.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 26 January 2004 Resolved
Crew was not able to start either lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2004
Resolution: Crew started lifeboats prior to departing.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 March 2002 Resolved
WINDSHIELD DECK RAIL IS BEND AND BROKEN IN SOME PARTS. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Accommodation/Occupational Safety › Cooking Systems
Issued 30 March 2002 Resolved
GREASE ON TOP OF THE STOVE NEEDS TO BE CLEANED.
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Inspectors recommended that cleaning should be done at least once a week.
Electrical › Electrical Distribution System (service)
Issued 30 March 2002 Resolved
LIGHT SWITCH IN ROOM 210 ( ANTEROOM) NEEDS A COVER. LEGACY COMPONENT DESC: Switch
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 30 March 2002 Resolved
REMOVE PAINT AND SOLVENT FROM LAUNDRY ROOM.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2002
Resolved 30 March 2002
Resolution: ITEMS WERE REMOVED PRIOR TO THE BOARDING TEAM LEAVING.
Accommodation/Occupational Safety › Occupational Safety
Issued 30 March 2002 Resolved
HOOKS AND EYES FOR LIFELINE CHAIN NEXT TO STARDBOARD LIFEBOAT IS CORROTED AND BROKEN. LEGACY COMPONENT DESC: Lifeline
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Lifesaving › Lifeboat
Issued 30 March 2002 Resolved
REPLACE COVER IN FRONT OF ENGINE IN THE PORT LIFEBOAT. LEGACY COMPONENT DESC: Rigid Cover
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 March 2002 Resolved
INSTALLL GUARD FOR PULLEYS AND BELTS OF WASHING MACHINE MECHANISM. LEGACY COMPONENT DESC: Laundry
Condition: Unknown
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Electrical › Lighting (service)
Issued 30 March 2002 Resolved
COVERS FOR THE LIGHT FIXTURES IN THE ROOM ADJACENT TO LAUNDRY ROOM NEED TO BE INSTALL. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 30 March 2002 Resolved
LAUNDRY ROOM DOOR MECHANISM NEEDS TO BE INSTALL. LEGACY COMPONENT DESC: Laundry
Condition: Improper Installation
Due 29 April 2002
Resolved 13 August 2002
Resolution: rcvd fm master stating def.sj12 was corrected
Navigation › Piloting/Steering
Issued 23 March 2002 Resolved
INLAND RULES OF THE ROAD MISSING FROM THE BRIDGE. LEGACY COMPONENT DESC: Inland Navigation Rules
Condition: Unknown
Due 30 April 2002
Resolved 9 June 2002
Resolution: Book on board.
Accommodation/Occupational Safety › Occupational Safety
Issued 23 March 2002 Resolved
HANDRAILS GOING FROM COMPACT DECK TO THE BRIDGE DECK GOING TO THE BOAT DECK ARE CORROTED AND NEEDS REPAIR. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done during dry dock.
Construction/Loadline › Structures
Issued 23 March 2002 Resolved
WATERTIGHT DOOR OF THE IMMERSION SUIT LOCKER IS CORROTED ALONG WITH THE KNIFE EDGE. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 29 April 2002
Resolved 9 June 2002
Resolution: Repairs done in dry dock.
Engineering
Issued 25 September 2000 Resolved
HYDRO TEST THE HEAVY FUEL OIL AND DIESEL OIL TRANSFER PIPING. PIPING TO BETESTED TO 1.5 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE. 33CFR156.170(C) TO BE COMPLETED PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Documentation
Issued 25 September 2000 Resolved
PROVIDE HAZMAT TRAINING TO THE [name withheld] OFFICER. 49CFR172.702 TO BE COMPLETED PRIOR TO CARGO AT NEXT U.S. PORT THAT INVOLVES HAZARDOUS MATERIAL.
Condition: Unknown
Due 10 January 2001
Resolved 10 January 2001
Engineering
Issued 25 September 2000 Resolved
RENEW HEAVY FUEL OIL PIPING FROM WERE IT COMES UP FROM THE DECK TO BOTH THEPORT AND STARBOARD FULL CONNECTIONS. RENEW PIPE HANGERS. TO BE COMPLETED PRIOR TO NEXT U.S. PORT. PROVIDE REPORT FROM THE SURVEYOR AUTHORIZED TO ACT ON BEHALF OF THE FLAG ADMINISTRATION.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Engineering
Issued 25 September 2000 Resolved
RENEW DIESEL OIL PIPING FROM WERE IT COMES UP FROM THE DECK TO BOTH THE PORT AND STARBOARD FILL CONNECTIONS. REMEW PIPE HANGERS. TO BE COMPLETED PRIOR TO NEXT U.S. PORT. PROVIDE REPORT FROM THE SURVEYOR AUTHORIZED TO ACT ON BEHALF OF THE FLAG ADMINISTRATION.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Accommodation/Occupational Safety
Issued 25 September 2000 Resolved
RENEW MARPOL STARDARD DISCHANGE (PIPING) CONNECTION FROM WERE IT COMES UP THROUGH THE DECK TO THE DISCHANGE CONNECTION. MARPOL73/78 I/19
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Accommodation/Occupational Safety
Issued 25 September 2000 Resolved
REPAIR HOLE ON AFT END, TOP OF TANK, ON THE SEWAGE TREATMENT SYSTEM, 33CFR159.7 TO BE COMPLETED PRIOR TO NEXT U.S. PORT. PROVIDE REPORT FROM THE SURVEYOR AUTHORIZED TO ACT ON BEHALF OF THE FLAG ADMINISTRATION.
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Lifesaving
Issued 25 September 2000 Resolved
PROVE PROPER OPERATION OF THE LIMIT SWITCHES ON THE PORT LIFEBOAT. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING SURVEYOR AUTHORIZED TO ACT ON BEHALF OF THE FLAG ADMINISTRATION. SOLAS 74 AMENDED III/19
Condition: Unknown
Due 4 December 2000
Resolved 4 December 2000
Electrical
Issued 30 November 1999 Resolved
PORT GANGWAY WINCH MOTOR ELECTRICAL JUNCTION BOX WASTED WITH WIRING EXPOSED. REPAIR TO SATISFACTION OF CLASS SOCIETY PRIOR TO 30DEC99. FAX REPORT TO USCG.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Fire Fighting
Issued 30 November 1999 Resolved
HOLED FIRE HOSES ON BRIDGE DECK STBD AND AT FORE PEAK. REPLACE PRIOR TO DEPARTING PORT OF NEW YORK. RECEIVED FAX CLEARING ITEM.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Navigation
Issued 30 November 1999 Resolved
UNRELIABLE COMMUNICATIONS BETWEEN BRIDGE AND STEERING ROOM. REPAIR PRIOR TO 30DEC99. FAX REPORT TO USCG NEW YORK. RECEIVED FAX FROM CLASS CLEARINGITEM.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Lifesaving
Issued 30 November 1999 Resolved
PROVIDE SERVICE REPORT FOR LIFERAFTS AND FIRE FIGHTING EQUIPMENT. PROVIDE USCG WITH INFO PRIOR TO DEPATURE FROM NEW YORK. RECIEVED FAX CLEARING ITEM.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Fire Fighting
Issued 30 November 1999 Resolved
REPLACE BROKEN LIGHTS IN THE CO2 ROOM. REPAIR PRIOR TO 30DEC99. FAX REPORT TO USCG. RECEIVED FAX CLEARING DEF.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Lifesaving
Issued 30 November 1999 Resolved
UNABLE TO ADEQUATELY RELEASE FALLS ON STBD LIFEBOAT. REPAIR TO SATISFACTION OF CLASS PRIOR TO DEPARTING PORT OF NEW YORK. RECEIVED FAX CLEARING ITEM.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Lifesaving
Issued 30 November 1999 Resolved
STBD LIFEBOAT BRAKE RELEASE MECHANISM WASTED. REPAIRED ON SCENE.
Condition: Unknown
Due 30 November 1999
Resolved 7 December 1999
Electrical
Issued 30 November 1999 Resolved
EMERGENCY GENERATOR LEAKING LUBE OIL AT FILTER. REPAIR TO SATISFACTION OF CLASS PRIOR TO 30DEC99. FAX REPORT TO USCG. CLEARED DEF BY FAX.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Electrical
Issued 30 November 1999 Resolved
EMERGENCY GENERATOR IS LEAKING COOLANT AT EXTERNAL HOSE CONNECTION, RIGHT SIDE OF MOTOR. REPAIR PRIOR TO 30DEC99. DEF CLEARED BY FAX.
Condition: Unknown
Due 1 December 1999
Resolved 7 December 1999
Electrical
Issued 26 July 1998 Resolved
MAKE PERMANENT REPAIRS TO THE EMERGENCY GENERATOR BATTERY CHARGER TO SATISFACTION OF CLASS SOCIETY. SOALS 74/I/II.
Condition: Unknown
Due 27 July 1998
Resolved 30 July 1998
Unknown
Issued 26 July 1998 Resolved
PROVIDE A CLASS SOCIETY SURVEY ATTESTING T0:1.CONDITION OF UNDERWATER HULL_x001C_2. INTERNAL CONDITION OF THE HULL IN WAY OF THE AREA OF THE GROUNDING.3 ROOT CAUSE OF THE LOSS OF ELECTRICAL POWER AND PROPULSION CONTROL AND CORRECTIVE ACTION TAKEN.
Condition: Unknown
Due 27 July 1998
Resolved 30 July 1998
Navigation
Issued 26 July 1998 Resolved
CLEAN OIL FROM ENTIRE DECK OF STEERING COMPARTMENT AS REQUIRED BY SOLAS 74 I/II.
Condition: Unknown
Due 27 July 1998
Resolved 30 July 1998
Electrical
Issued 26 July 1998 Resolved
REPLACE WASTED/LEAKING DRAIN COCK FOR EMERGENCY GENERATOR JACKET WATER PUMP. TO BE COMPLETED TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY AS REQUIRED BY SOLAS 74. I/11
Condition: Unknown
Due 27 July 1998
Resolved 30 July 1998
Unknown
Issued 22 April 1998 Resolved
MAKE REPAIRS TO OILY WATER SEPARATOR MONITOR SYSTEM TO SATISFACTION OF CLASS. PROVIDE CLASS SURVAYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Fire Fighting
Issued 22 April 1998 Resolved
MAKE REPAIRS TO PORT SIDE FIRE PUMP TO SATISFACTION OF CLASS. PROVIDE CLASSSURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Navigation
Issued 4 March 1985 Resolved
NO TIDE CURRENT BOOK ON BOARD.
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Documentation
Issued 4 March 1985 Resolved
12 HOUR EQUIPMENT TEST NOT LOGGED.
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Navigation
Issued 4 March 1985 Resolved
NO TIDE TABLE BOOK ON BOARD.
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.