MAURY USCG vessel records Sign in
← All vessels

KASUGA BAY

KASUGA BAY is a 1984 freight ship. The Coast Guard has recorded 29 inspections since 1985, most recently in August 2011, along with 20 deficiencies and 1 operational control.

Records from 1985 to 2011. Most recent: inspection, 5 August 2011.

Built
1984
Last inspected
5 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8213615 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
247087
Flag
PANAMA
—
Maury page id
psix-247087

Inspections, by type

…with no type recorded20
Years with a record 15 calendar years (1985–2011)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it9274 - Simplified, Gross Ton
9274 - Convention (Subpart B), Gross Ton
10641 - Dead Weight, Ton
16150 - Displacement, Ton
4593 - Convention (Subpart B), Net Ton
4593 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 29

5 August 2011 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 4105702
10 November 2010 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3888981
11 July 2008 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3264241
28 September 2007 Deficiency Check
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 3068001
26 July 2007 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3002395
8 February 2007 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2878092
7 February 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2868638
24 January 2006 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2572477
23 January 2006 PII Safety Exam · Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2571292
21 December 2004 PII Safety Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2262916
18 December 2004 ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2261184
9 April 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1770545
24 February 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 287525
16 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286022
2 August 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 431186
17 June 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 344397
25 February 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 342115
15 June 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 337637
22 December 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 327520
8 December 1988 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 327257
25 October 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 475436
6 September 1988 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 459616
11 December 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 320173
8 December 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 320108
18 November 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 319661
24 November 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 499623
5 March 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 307337
8 April 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 301271
15 March 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300853

Deficiency record · 20

Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2007 Resolved
Observed missing insulation and improperly fitted metal shielding for the auxiliary boiler at the access cover on the aft side. There also appears to be a possible hole just above this area as indicated by lack of insulation and a coating of soot rising above the area. Correct to the satisfaction of class.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 September 2007
Resolution: Received documents via fax reflecting class approval of repairs made to auxiliary boiler.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 January 2006 Resolved
Shock and fire hazards present throughout ship due to missing covers on fixed lighting.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 6 February 2006
Resolved 24 January 2006
Resolution: Light covers replaced with the exception of two unavailable strip lights. New strip lights are on order. Lamp assembly were disconnected.
Engineering › Freshwater Generation System › Piping
Issued 23 January 2006 Resolved
Soft patches were found on ship's fresh water system as well grey water system.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 24 January 2006
Resolved 24 January 2006
Resolution: Wasted and holed piping replaced as necessary (Class attestation).
Engineering › Fuel Oil Service System › Piping
Issued 23 January 2006 Resolved
Permanent repairs needed to prevent leaking from high pressure fuel oil line to fuel injector
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2006
Resolved 24 January 2006
Resolution: FO Line to MDE fuel ingector replaced (Class attestation).
Lifesaving › Lifeboat › Propulsion Engine
Issued 21 December 2004 Resolved
Lifeboat would not start.
Condition: Unknown
Action required: 705 - Other - as specified
Due 22 December 2004
Resolved 22 December 2004
Resolution: Received class report stating engine on lifeboat was started and operated satisfactorily.
Fire Fighting
Issued 16 January 2001 Resolved
EMERGENCY FIRE PUMP MISSING BELT GUARD, IN VIOLATION OF SOLAS 74/78 II- 1/26.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Deck/Cargo
Issued 16 January 2001 Resolved
VENTILATION FROZEN ON #4AS AND #4BCS CARGO HOLDS, IN VIOLATION OF SOLAS 74/78 II-2/53-2.3.
Condition: Unknown
Due 17 January 2001
Resolved 18 January 2001
Accommodation/Occupational Safety
Issued 16 January 2001 Resolved
MARINE SANITATION DEVICE MISSING PLACARD, IN VIOLATION OF 33 CFR 159.55.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Lifesaving
Issued 16 January 2001 Resolved
LIFEBOATS EACH MISSING A KNIFE, IN VIOLATION OF SOLAS 74/78 III/41-8.22.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Fire Fighting
Issued 16 January 2001 Resolved
FIREMAN'S OUTFIT ON BRIDGE MISSING FLASHLIGHT, IN VIOLATION OF SOLAS 74/78 II-2/17-1.1.4.
Condition: Unknown
Due 17 January 2001
Resolved 18 January 2001
Fire Fighting
Issued 16 January 2001 Resolved
NO FIRE PROTECTION CAPACITY IN PAINT LOCKER, IN VIOLATION OF SOLAS 74/78 II-2/18-2.4.7.
Condition: Unknown
Due 16 January 2001
Resolved 18 January 2001
Electrical
Issued 16 January 2001 Resolved
CONTROL ROOM AND STEERING FLAT MISSING NON-CONDUCTIVE MATTING/GRATING, IN VIOLATION OF SOLAS 74/78 II-1/45.2.
Condition: Unknown
Due 14 March 2001
Resolved 14 March 2001
Documentation
Issued 15 June 1990 Resolved
A vio of 33CFR155.820 in that the vsl did not have a written record of the date and results of the most recent test of the oil transfer system as req by 33CFR156.170.
Condition: Unknown
Due 15 June 1990
Resolved 15 June 1990
Navigation
Issued 8 December 1988 Resolved
CHARTS 11413, 11414, NOT CURRENTLY CORRECTED TO DATE, NO FORIEGN EQUIVALENTON BOARD. 11413 MISSING NTM 84-35,36,41,43,45,51,52. 11414 MISSING NTM 87-27,41,46 AS REQUIRED BY 33 CFR 164.33 (A)(1)(II)
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Accommodation/Occupational Safety
Issued 8 December 1988 Resolved
VESSEL MSD NOT LABELED IAW 33 CFR 159.7 (B) (1) MANUFACTURE ISHI KOSAKUSHO CO. LTD.
Condition: Unknown
Due 8 December 1988
Resolved 8 December 1988
Navigation
Issued 18 November 1987 Resolved
VSL DID NOT HAVE TIDAL CURRENT TABLES (ATLANTIC COAST OF NORTH AMERICA) ONBOARD. AS REQUIRED BY 33 CFR 164.33 (A)(3)(II). VESSEL IS 9274 GROSS TONSVESSEL TRANSITTED BUZZARDS BAY AND NEW BEDFORD HARBOR ON 15 NOV 87.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Documentation
Issued 18 November 1987 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. MISSING INFORMATION AS REQUIRED BY 33 CFR 155.750 (A)(9). THIS WAS NOTED ON MSO PROVIDENCE FOREIGN FREIGHT VESSEL EXAM FORM DATED 18 NOV 87. TRANSFER OPERATION WAS NOT IN PROGRESS WHEN DISCREPANCY WAS NOTED.
Condition: Unknown
Due 18 November 1987
Resolved 18 November 1987
Navigation
Issued 15 March 1985 Resolved
THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF OR EXTRACT FROM THE U.S. COAST GUARD LIGHT LIST OR A FOREIGN EQUIVALENT
Condition: Unknown
Due 15 March 1985
Resolved 15 March 1985
Navigation
Issued 15 March 1985 Resolved
THE VESSEL DID NOT HAVE U.S. CHARTS 12214,12304,12311,12312 AND OR THEIR FOREIGN EQUIVALENTS CORRECTED UP TO DATE
Condition: Unknown
Due 15 March 1985
Resolved 15 March 1985
Navigation
Issued 15 March 1985 Resolved
THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF OR EXTRACT FROM THE U.S. COAST PILOT OR A FOREIGN EQUIVALENT
Condition: Unknown
Due 15 March 1985
Resolved 15 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.