MAURY USCG vessel records
← All vessels

DALDEAN

DALDEAN is a passenger vessel (inspected). The Coast Guard has recorded 3 inspections since 2016, most recently in July 2017, along with 16 deficiencies — 2 with no resolution recorded —.

Records from 2016 to 2017. Most recent: inspection, 28 July 2017.

Built
Not recorded
Last inspected
28 July 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 July 2017
…past their stated due date2
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

247090
Flag
CANADA
Maury page id
psix-247090

Documentation record

Tonnage as PSIX records it145 - Regulatory (Subpart C or D), Gross Ton
99 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

28 July 2017 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6223707
4 May 2017 COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6141298
6 May 2016 COC-CVE Annual · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5872201

Deficiency record · 16

Engineering › Lubricating Oil Service System › Hose
Issued 4 May 2017 Resolved
Make permanent repairs to hydraulic line on U.S. side hydraulic cylinder ramp line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Hydraulic lines were replaced.
Fire Fighting › Fire Pumps › Pressure
Issued 4 May 2017 Resolved
Renew fire pump pressure output gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Pressure gauge was replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 May 2017 No resolution recorded
Renew exhaust lagging on main engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 4 May 2017 Resolved
Replace light within E/R
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Light was replaced.
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 May 2017 Resolved
Properly mark fuel oil shutoffs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Fuel shutoffs were properly marked.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 4 May 2017 Resolved
Fire pump IVO E/R leaking heavily at gland. Make permanent repairs to ensure proper pressure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Witnessed satisfactory test of the system.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016 Resolved
Vessels car deck and pilot house ring buoys are unserviceable.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 20 May 2016
Resolution: New ring buoys examined as installed. All sat.
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 May 2016 Resolved
Improper instalation of the painter and improperly secured bowsing line to the vessels railing.
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Corrected on the spot
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 May 2016 Resolved
Bilges have an excess amount of water and require removal.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 20 May 2016
Resolution: All bilges examined and water and oily waste has been removed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 May 2016 Resolved
Emergency Egress lighting on both ends have been painted over.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Paint cleaned off of lighting faces. Lights tested, all sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 May 2016 Resolved
Junction box outside the engineers room needs a junction box cover.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Junction box installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 May 2016 Resolved
Mounting bracket is not correct for the extinguisher.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Proper mount and bracket installed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 May 2016 Resolved
US side main transverse bulkhead requires a plug in a hole that was used to service a wire run.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Old stuffing box sealed within bulkhead. All sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 May 2016 No resolution recorded
US side watertight door outside steering gear room requires gasket material.
Action required: 705 - Other - as specified
Due 31 May 2016 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 6 May 2016 Resolved
Steering gear room lighting fixture has a short.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: New fixture installed. Short was within unit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2016 Resolved
US side forward masthead is missing its base.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Base properly attached.

Ownership record