Records from 1985 to 2017. Most recent: inspection, 28 July 2017.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
28 July 2017
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6223707
4 May 2017
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6141298
6 May 2016
COC-CVE Annual · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5872201
25 May 2012
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4321361
10 May 2012
COC-CVE Initial
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4307688
26 October 2010
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3877747
1 April 2009
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3445575
21 April 2008
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3189142
13 April 2007
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2907297
3 May 2006
COC-CVE Annual
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2639212
6 April 2004
Certificate of Compliance
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2055346
10 April 2003
Certificate of Compliance
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1777626
6 June 2002
Certificate of Compliance
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1718261
12 April 2000
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1440301
14 May 1999
Control Verification · Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 797426
15 April 1999
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1391049
17 April 1998
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1467539
30 May 1997
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1406128
18 April 1997
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1418131
23 July 1996
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1086953
25 April 1996
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1081245
31 May 1995
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 875851
11 April 1995
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1160158
13 April 1994
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 857093
14 April 1993
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1358048
14 April 1992
Certificate of Compliance
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1267673
17 June 1991
Certificate of Compliance
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 887032
19 April 1991
Certificate of Compliance
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 918973
19 April 1990
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 911608
21 April 1989
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 893315
13 June 1988
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 890099
28 April 1988
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1343066
1 July 1987
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1010992
30 April 1987
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1018316
30 September 1986
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1006282
30 July 1986
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1302070
26 June 1986
Control Verification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1302891
5 March 1986
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 986895
8 March 1985
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 977822
Engineering › Lubricating Oil Service System › Hose
Issued 4 May 2017
Resolved
Make permanent repairs to hydraulic line on U.S. side hydraulic cylinder ramp line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Hydraulic lines were replaced.
Fire Fighting › Fire Pumps › Pressure
Issued 4 May 2017
Resolved
Renew fire pump pressure output gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Pressure gauge was replaced.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 May 2017
No resolution recorded
Renew exhaust lagging on main engine.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 4 May 2017
Resolved
Replace light within E/R
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Light was replaced.
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 May 2017
Resolved
Properly mark fuel oil shutoffs
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Fuel shutoffs were properly marked.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 4 May 2017
Resolved
Fire pump IVO E/R leaking heavily at gland. Make permanent repairs to ensure proper pressure.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 28 July 2017
Resolution: Witnessed satisfactory test of the system.
Lifesaving › Lifebuoys › Serviceable
Issued 6 May 2016
Resolved
Vessels car deck and pilot house ring buoys are unserviceable.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 20 May 2016
Resolution: New ring buoys examined as installed. All sat.
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 May 2016
Resolved
Improper instalation of the painter and improperly secured bowsing line to the vessels railing.
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 6 May 2016
Resolution: Corrected on the spot
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 6 May 2016
Resolved
Bilges have an excess amount of water and require removal.
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 20 May 2016
Resolution: All bilges examined and water and oily waste has been removed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 6 May 2016
Resolved
Emergency Egress lighting on both ends have been painted over.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Paint cleaned off of lighting faces. Lights tested, all sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 6 May 2016
Resolved
Junction box outside the engineers room needs a junction box cover.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Junction box installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 6 May 2016
Resolved
Mounting bracket is not correct for the extinguisher.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Proper mount and bracket installed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 May 2016
Resolved
US side main transverse bulkhead requires a plug in a hole that was used to service a wire run.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Old stuffing box sealed within bulkhead. All sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 6 May 2016
No resolution recorded
US side watertight door outside steering gear room requires gasket material.
Action required: 705 - Other - as specified
Due 31 May 2016 — due date passed with no resolution recorded
Electrical › Lighting (service) › Lighting Fixture
Issued 6 May 2016
Resolved
Steering gear room lighting fixture has a short.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: New fixture installed. Short was within unit.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 May 2016
Resolved
US side forward masthead is missing its base.
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 20 May 2016
Resolution: Base properly attached.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 10 May 2012
Resolved
Issued requirement to: Renew main engine control linkage fasteners with proper type/size shoulder bolts.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 25 May 2012
Resolution: Proper fasteners installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 May 2012
Resolved
Issued requirement to: Provide drainage or raise bracket for fire extinguisher in engine room. US side.
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 25 May 2012
Resolution: Bracket was raised.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 May 2012
Resolved
Issued requirement to: Complete Transport Canada requirement issued 9 May 2012.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 May 2012
Resolved 25 May 2012
Resolution: Work list items complete.
Construction/Loadline › Structures › Deck Plating
Issued 13 April 2007
Resolved
The fifth vertical frame aft of the forward water tight compartment port side engine room has a 1" fracture IWO overhead deck plate and vertical frame weld.
Action required: 705 - Other - as specified
Resolved 14 April 2007
Resolution: Fracture has been ground out and re-welded.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 3 May 2006
Resolved
Fractured frame in MDE room #2.
Due 10 May 2006
Resolved 5 May 2006
Resolution: V grind and welded fracture.
Fire Fighting › Fire Main › Condition
Issued 3 May 2006
Resolved
Doubler patch on fire main in space below office space.
Due 10 May 2006
Resolved 5 May 2006
Resolution: Cropped and renewed with new pipe.
Fire Fighting
Issued 15 April 1999
Resolved
U. S. side firehose holed.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Lifesaving
Issued 15 April 1999
Resolved
Port pilothouse ringbuoy cracked/fractured.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Lifesaving
Issued 15 April 1999
Resolved
Excessive water in bilge from leaking propeller shaft U. S. side.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Engineering
Issued 15 April 1999
Resolved
Exhaust heat shield/blanket missing from Canadian MDE.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Engineering
Issued 15 April 1999
Resolved
Water leaking from U. S. side propeller shaft into engine room bilges.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Lifesaving
Issued 15 April 1999
Resolved
Caked oil residue up to 1 inch thick coating deck plate frames throughout machinery space.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Navigation
Issued 15 April 1999
Resolved
Both rudders allowing excessive water into the bilges.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Lifesaving
Issued 28 April 1988
Resolved
PROVIDE TWO ADDITIONAL PERSONAL FLOATATION DEVICES TO MAKE A TOTAL OF 128.
Condition: Unknown
Due 28 April 1988
Resolved 28 April 1988