← All vessels
GENERAL RUDDER
GENERAL RUDDER is a 1984 school ship. The Coast Guard has recorded 132 inspections since 1985, most recently in May 2024, along with 194 deficiencies, 3 operational controls and 5 casualty investigations between 2017 and 2022.
Records from 1985 to 2024. Most recent: inspection, 3 May 2024.
- Built
- 1984
- Last inspected
- 3 May 2024
- Documentation
- Duplicated in Error · documentation file of 10 September 2026
- Inspections
- 132
- Deficiencies
- 194 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 5 investigations · 2017–2022
Identity
1277959
8835463 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WTAU
247134
Flag
UNITED STATES
—
Maury page id
psix-247134
Inspections, by type
…with no type recorded25
Years with a record
39 calendar years (1985–2024)
The 132 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 1981.
Documentation record
Registered dimensions (L × B × D)200.0 ft
Registered tonnagegross 1,914 / net 574
ITC dimensions (L × B × D)200.0 ft
ITC tonnageNot recorded
Builderbuilder not recorded · TACOMA, WA, UNITED STATES · built 1984
Hull materialSteel
PropulsionDiesel Electric
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALVESTON, TX
Trade endorsementsNot recorded
DocumentationDuplicated in Error
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1914 - Regulatory (Subpart C or D), Gross Ton
574 - Regulatory (Subpart C or D), Net Ton
574 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 132
3 May 2024
Examination of Repairs · COI Inspection · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7905952
16 May 2023
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7685532
10 February 2023
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7995982
20 September 2022
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7562651
1 August 2022
Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7522216
27 July 2022
Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7521941
12 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7504580
23 June 2022
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7485034
18 June 2022
Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7482136
4 May 2022
In-Service Inspection · COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7442913
1 March 2022
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7404350
23 September 2021
Internal Structural Exam · COI Inspection · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7318656
20 May 2021
Deficiency Check · Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7194225
5 May 2021
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7191088
23 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7100371
15 May 2020
COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6953874
17 September 2019
Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6804785
28 June 2019
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6736832
10 June 2019
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6709849
4 June 2019
COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6703753
12 April 2019
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6662919
1 April 2019
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6662902
1 August 2018
Examination of Repairs · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6498175
31 July 2018
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6498113
15 May 2018
Examination of Repairs
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6415261
7 May 2018
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6407974
5 January 2018
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6333087
1 December 2017
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6316517
3 November 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6300346
24 July 2017
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6219814
12 June 2017
In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6173619
2 June 2017
Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6167754
1 June 2017
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6334932
20 May 2017
Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6152158
17 May 2017
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6148689
8 May 2017
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6144563
31 March 2017
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6114967
5 October 2016
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6016602
6 July 2016
Deficiency Check · Examination of Repairs
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5932063
14 June 2016
Drydock Extension
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5936785
10 May 2016
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5873638
2 March 2016
Construction Oversight
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5853971
17 September 2015
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5721246
18 July 2015
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5191612
8 May 2014
MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4853629
18 January 2012
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4234874
5 July 2011
Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4070259
29 November 2010
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3900565
10 July 2009
Internal Structural Exam · Hull Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3530419
20 April 2009
Drydock Extension
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 3461848
19 May 2008
MTSA Verification · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3208161
25 October 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3086949
17 July 2007
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2997886
29 May 2007
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2945163
30 August 2006
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2763729
31 May 2006
COI Inspection · MTSA/ISPS Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2665872
15 May 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2649907
1 November 2005
Examination of Repairs
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2526055
1 June 2005
COI Inspection · MARPOL Annex V Examination · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2375718
22 March 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2316515
9 July 2004
MTSA/ISPS Verification
Physical examination · Commandant (CG-CVC) · Activity 2127406
13 May 2004
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2066741
12 May 2004
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2078952
29 January 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1996771
12 August 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1873901
10 June 2003
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1813755
26 November 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1711749
8 October 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1686459
2 July 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1633968
21 September 2001
Deficiency Check · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1428091
22 August 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071658
19 June 2001
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1471048
19 April 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1439191
16 June 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 819584
24 May 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1413733
18 April 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063865
31 August 1999
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 781166
9 August 1999
Damage Survey · Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1411943
29 June 1999
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 157829
23 June 1999
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1426224
10 June 1999
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1432133
5 October 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 801860
5 August 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1131165
21 October 1997
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421460
31 July 1997
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1465333
1 July 1997
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1109154
7 April 1997
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 773365
5 September 1996
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1254630
11 June 1996
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1096641
21 March 1996
Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1394484
30 June 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182738
21 December 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 854373
14 September 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173236
5 July 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1173880
22 March 1994
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 857663
30 December 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161279
16 December 1993
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160415
9 June 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836049
7 April 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146310
17 February 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146174
9 August 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 123999
9 July 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1255741
12 June 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1267032
16 January 1992
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1412414
29 December 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 183563
23 October 1991
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1245386
13 August 1991
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936162
2 July 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 911272
5 April 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1232735
21 December 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 911136
11 June 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1219092
6 June 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 930486
17 May 1990
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 930968
3 January 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 919212
27 November 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 928119
25 August 1989
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308295
19 December 1988
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1042359
20 May 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 888283
4 May 1988
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1030931
21 October 1987
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1324900
30 June 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1018320
14 May 1987
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1025832
20 August 1986
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295870
29 May 1986
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990052
25 April 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1001049
6 November 1985
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989668
16 August 1985
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 985403
23 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 983088
21 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1291073
14 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 987633
2 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 978038
16 April 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 979969
Deficiency record · 194
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangements rescue boats
Issued 27 June 2024
Resolved
Each muster station and embarkation station must be adequately illuminated by lighting with power supplied from the vessel's emergency source of electrical power. Crew members were unable to turn on emergency lighting over the rescue boat. Must provide light in area prior to getting underway.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2021
Resolved
Non-conducting deck coverings must be installed for personnel protection at the front and rear of the switchboard.
Replace non-conducting matting in engine control room to ensure it covers the entire length of the front and rear of all switchboards. Complete by next drydock.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 26 May 2021
Resolved
Materials used in construction of vessels which conform to the specifications of the Navy or the Coast Guard may be accepted.
Galley doors are not of an A-Class standard. Replace both doors between the galley and messrooms with A-Class doors in drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2019
Resolved
Each vessel must carry life jackets for each person on board that are approved under 46 CFR Subchapter Q. 23 life jackets were deemed to no longer be in sufficient condition to provide adequate buoyancy. All 23 life jackets need to be replaced prior to departure.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 June 2019
Resolved
Vessel's log for maintenance and inspection of lifesaving equipment has not been maintained. Provide logs, records and checklists in accordance with 46 CFR 199.190.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 4 June 2019
Resolved
The rescue boat on-board will be replaced when the vessel returns to Texas, for the CG accepted rescue boat. Noted that the engine cooling overboard discharge close to the point the boat is lowered to water, where the discharge could fill the lowered boat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
Crew could not provide Drug and Alcohol Program records. Provide program requirements in accordance with 46 CFR 16. Recommend audit of program.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 4 June 2019
Resolved
Vessel's COI lists stability letter from 1993. Vessel's stabilty book was amended in 2016. Remove old stability letter and provide the CG with updated stability information.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 4 June 2019
Resolved
Crew could not provide Vessel General Permit record of inspections. Provide records in accordance with the VGP.
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 4 June 2019
Resolved
Crew could not provide ballast water records or reports. Provide accurate records of ballast water and submit reports to NBIC as required.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 4 June 2019
Resolved
Checklist for test before getting underway or entering do not include all the requirements from 33 CFR 164.25.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 4 June 2019
Resolved
Provide operating procedures and block diagram for steering gear on the bridge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2019
Resolved
Install new Type 1 retro-reflective material on life jackets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2019
Resolved
Remove dead end cable in emergency gear locker #2.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 June 2019
Resolved
Provide safety relief valves for water heaters @ or below 100 psi for exemption from pressure vessel inspections.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 4 June 2019
Resolved
Noted leak on sliding water tight door hydraulic manifold in motor room. Repair as necessary and prove proper operation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2019
Resolved
Vessel did not have the required number of lifejackets on board as per their COI. Provide all required lifejackets in the proper stowage positions for inspection by attending marine inspector prior to carrying students.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 June 2019
Resolved
Vessel did not have required entries in radio log. Radio inspector and crew shall annotate log as required.
47 CFR 80.409(e)&(f)
Construction/Loadline › Hull › Hull Plating
Issued 24 July 2017
Resolved
Vessels steering compartment flooded out and vessel has lost steering. Repair to the satisfaction of the attending marine inspector.
Engineering › Steering Gear System › Rudder Stock
Issued 24 July 2017
Resolved
Vessel's CHENG reported hearing grinding and vibration during operation and restricted movement of the rudder.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 24 July 2017
Resolved
In accordance with sub chapter S vessel did not have on board required drawing for the safe operation of the vessel in normal and emergency conditions.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 24 July 2017
Resolved
Vessel did not have on board accurate drawings/tank plans to conduct safe ballasting operations.
Fire Fighting › Fixed Fire Detection System › Power Supply
Issued 12 June 2017
Resolved
Vessels fixed fire detection system was found completly inoperable in all spaces. System shall be repaired and tested satisfactorily prior to departure from Port.
Electrical › Electric Generation Source (service) › Number of Sources
Issued 20 May 2017
Resolved
failure of the automation system of the port propulsion motor. The automation controls were bypassed in the ECR. Repair and prove proper operation of the automation system. Until such time PUMS operations are not authorized.
Navigation › Piloting/Steering › Gyro Compass
Issued 17 May 2017
Resolved
Failure of navigational gyrocompass. Each vessel must have a gyrocompass. Vessel shall provide fully operational gyrocompass prior to departure from port.
Construction/Loadline › Structures › Machinery Space Opening
Issued 12 May 2017
Resolved
AFT eng room BLKH not water tight at various cable penetrations.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 6 July 2016
Resolved
The bridge's throttle controls failed due to a faulty wire coming from the control's power supply unit. This event also caused the port propulsion motor to shut down.
Engineering › Steering Gear System › Linkage
Issued 21 July 2015
Resolved
Starboard steering ram linkage bearing from ram end to steering shaft arm worked it way out of placed. issued CG-835 to make permanent repairs to both port and starboard steering ram linkages where it connects to the steering shaft arm
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 8 May 2014
Resolved
The embarkation ladders required by 46 CFR 199.110(e)(f) are not installed. Provide proposal including timeline for correction.
Fire Fighting › Ventilation Systems › Ducts
Issued 8 May 2014
Resolved
Provide manual fire closures for 4 vent openings identified by Marine Design.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 7 August 2009
Resolved
Halon bottles for the fixed firefighting system were over-pressured by 40 lbs. The vessel is required to contact a marine fire extinguishing servicing company to correct the over-pressuring.
Engineering › Diesel Engine (propulsion-electric) › Governor
Issued 16 May 2008
Resolved
The #2 SS Generator is missing the actuator. Replace actuator and demonstrate all operations for securing and emergency shut downs for the generator prior to placing engine back in service. All test to be witnessed by CG inspector.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 29 May 2007
Resolved
The #3 and #4 generators alarms for High J/W and loss of L/O are not annunciating, however they are shutting down the generators in an alarm condition. Repair alarms to the satisfaction of attending CG marine inspector.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 29 May 2007
Resolved
There are two (2) fuses located on the #2 generator panel (CB-2DG2) that are either missing/shorted or otherwise tampered with, identify the circuits and repair or replace the fuses and or circuit.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 May 2006
Resolved
Conduct drills w/ CG inspectors prior to carrying cadets.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2006
Resolved
Replace the expired medicine in the hospital.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 31 May 2006
Resolved
Lifesaving equipment record is incomplete. Weekly, monthly checks are not conducted IAW 46 CFR 199.190.
Operations/Management › Drills/Instruction › Not Conducted
Issued 31 May 2006
Resolved
Drills are not being conducted IAW46CFR199.190. Vessel must conduct required drills and log the same.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 31 May 2006
Resolved
Tests before entering port or getting underway are not conducted IAW 33CFR164.25.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 31 May 2006
Resolved
Repair light on the magnetic compass.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 31 May 2006
Resolved
Maneuvering fact sheet is missing the statement required by 33CFR164.35(g)(7).
Lifesaving › Inflatable Liferafts › Servicing
Issued 31 May 2006
Resolved
Provide liferaft servicing certificates for 2 rafts due Aug 2006.
Fire Fighting › Fire Main › Condition
Issued 31 May 2006
Resolved
Submit repair proposal for soft patch on the firemain (A/C flat).
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 31 May 2006
Resolved
Prove proper operation of the MSD compartment bilge high level alarm.
Engineering › Fuel Oil Service System › Hose
Issued 31 May 2006
Resolved
Various non-metallic flexible hoses in F/O and L/O service are either of improper material or beyond a reasonable service life. Replace or provide fire sleeve as needed IAW 46CFR56.60-25 (b).
Operations/Management › Cargo Transfer/Lightering › Conducted IAW Vessel Transfer Procedures
Issued 31 May 2006
Resolved
Amend current transfer procedures to comply w/ all requirements of 33CFR155.750.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 31 May 2006
Resolved
Prove proper operation of the bilge suction from the forward most compartment to the satisfaction of the attending Marine Inspector.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 31 May 2006
Resolved
Provide steering change over instructions on the bridge IAW 33CFR164.35.
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 November 2005
Resolved
Renew sewage overboard waster piece at side shell.
Electrical › Electric Supply System (service) › Cable
Issued 1 June 2005
Resolved
Remove the orange extension from the bridge overhead.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 1 June 2005
Resolved
Mount fire extinguisher in the rescue boat IVO the placard.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 June 2005
Resolved
Provide rescue boat lowering and raising procedures.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 1 June 2005
Resolved
Mount rescue boat procedures IVO the rescue boat.
Engineering › Bilge Water Management System › Not Operational
Issued 1 June 2005
Resolved
Prove proper operation of the installed bilge system.
Construction/Loadline › Penetrations › Gasket
Issued 20 June 2004
Resolved
Provide or prove that the EDG door is A-60 rated as per bulkhead and SFP for space. No stamp or tag on door and door shows evidence of being modifield
Construction/Loadline › Penetrations › Valve Flange
Issued 12 May 2004
Resolved
Replace stop check ball in vent for forepeak ballast tank port side fwd, also reinstall screen.
Lifesaving › Lifejacket/PFD (Type I)
Issued 10 June 2003
Resolved
Provide proof of receipt for lifejacket lights and whistles LEGACY COMPONENT DESC: Lights
Operations/Management › Drills/Instruction
Issued 10 June 2003
Resolved
Within 24 hrs of departure of port, provide copy of ships logbook and letter stating fire/boat drills were conducted with full crew. LEGACY COMPONENT DESC: Fire
Communications › Radio Communications
Issued 10 June 2003
Resolved
Provide proof of EPIRB registration LEGACY COMPONENT DESC: EPIRB
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 June 2003
Resolved
Provide 3-course deck rail for raised aft platform on stern iwo rescue boat iaw 46 CFR 169.327 LEGACY COMPONENT DESC: Deck Rail
Lifesaving › Inflatable Liferafts
Issued 20 June 2002
Resolved
Submit to CG Plan approval to intended changes to liferaft and berthing arrangements.
Engineering › Steering Gear System
Issued 20 June 2002
Resolved
Provide Block diagram ofm steering system on bridge.
Lifesaving
Issued 20 June 2002
Resolved
Replace missing SART prior to gettin U/W on Oceans route.ceans route
Stability › Watertight Integrity
Issued 20 June 2002
Resolved
Hyd WTD Inop.
Engineering › Diesel Engine (auxiliary)
Issued 20 June 2002
Resolved
Replace missing and worn lagging on SSDG's. LEGACY COMPONENT DESC: Piping (exhaust)
Engineering › Diesel Engine (propulsion-electric)
Issued 20 June 2002
Resolved
Prove prpoer operation of of overspeed and shutdowns .
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 20 June 2002
Resolved
Repair broken cable for remote operation of FFF sytem.
Engineering › Bilge Water Management System
Issued 20 June 2002
Resolved
Prove proper operation fo bilge pump. LEGACY COMPONENT DESC: Pump
Operations/Management › Drills/Instruction
Issued 20 June 2002
Resolved
Demonstrate satisfactory rescue boat drill..
Engineering
Issued 20 June 2002
Resolved
Demonstrate satisfactory automation verification.
Electrical › Electrical Distribution System (service)
Issued 20 June 2002
Resolved
Auto shutdown feature on SCR cooling Blower inop-Prove proper ops.
Electrical
Issued 20 June 2002
Resolved
Prove proper opersation of barring gear engaed alarm. LEGACY COMPONENT DESC: BARRING GEAR ALARM
Electrical
Issued 20 June 2002
Resolved
Prove proper operation of Emergency propulsion machinery on One (1) SCR. (II A. 18-21 in T-agos operational manual.
Fire Fighting
Issued 19 June 2001
Resolved
REPAIR MAIN MOTOR FIXED CO2 SYSTEM PRESSURE SWITCHES (PORT & STBD) AND RETEST IN CG PRESENCE.
Lifesaving
Issued 19 June 2001
Resolved
RENEW RING BUOY LINES WITH U/V RESISTANT LINE.
Lifesaving
Issued 19 June 2001
Resolved
POST LIFEJACKET DONNING PLACARDS IN ALL STATEROOMS/BERTHING AREAS.
Unknown
Issued 19 June 2001
Resolved
REPLACE SHIP'S SERVICE AIR RECEIVER W/ONE RATED BELOW MAWP.
Lifesaving
Issued 19 June 2001
Resolved
IMPLIMENT A LIFESAVING EQUIPMENT MAINTENANCE RECORD IAW 46CFR199.190.
Lifesaving
Issued 19 June 2001
Resolved
UPDATE TRAINING MANUAL AND STATION BILL IAW 46CFR199.180.
Lifesaving
Issued 19 June 2001
Resolved
C/R PORT QUARTER LIFERAFT STATION FORWARD OUTBOARD PLATE/SKIRT AND STRUCTURAL FRAME MEMBER WHERE WASTED.
Fire Fighting
Issued 19 June 2001
Resolved
SERVICE GAYLORD RANGEHOOD SYSTEM & RETEST IN USCG PRESENCE.
Lifesaving
Issued 19 June 2001
Resolved
CONDUCT SATISFACTORY FIRE AND BOAT DRILLS W/ADEQUATE VSL CREW AND CADET PRESENCE.
Fire Fighting
Issued 19 June 2001
Resolved
REPAIR/RENEW FAULTY EMERGENCY GEN HALON FIXED FF SYSTEM TIME DELAYS & RETEST IN CG PRESENCE.
Accommodation/Occupational Safety
Issued 19 June 2001
Resolved
MAKE PERMANENT REPAIRS TO MSD PIPING SYSTEM.
Engineering
Issued 19 June 2001
Resolved
PROVIDE ONBOARD AIR COMPRESSOR FOR START AIR FOR SSG'S.
Lifesaving
Issued 19 June 2001
Resolved
PROVIDE LIFERAFT LAUNCHING INSTRUCTIONS AT ALL LAUNCHING PLATFORMS.
Engineering
Issued 19 June 2001
Resolved
RENEW DAMAGED GOOSENECK VENT SCREENS ON DECK AS NEEDED.
Fire Fighting
Issued 19 June 2001
Resolved
PROVIDE/RENEW TWO 10FT FOG APPLICATORS.
Fire Fighting
Issued 19 June 2001
Resolved
PROVIDE COPY OF FIRE EXTINGUISHER SERVICING CERTIFICATES.
Fire Fighting
Issued 16 June 2000
Resolved
Prove proper operation of #2 M.E. shutdown upon initiation of fixed FF system.
Engineering
Issued 16 June 2000
Resolved
Prove proper operation of #4 M.E. lube oil shutdown.
Engineering
Issued 16 June 2000
Resolved
Prove proper operation of EOT failure alarm.
Engineering
Issued 16 June 2000
Resolved
Prove proper operation of oily water separator and alarm IAW 33 CFR 155.
Lifesaving
Issued 16 June 2000
Resolved
Conduct satisfactory fire and abandon ship drills.
Electrical
Issued 16 June 2000
Resolved
Prove proper operation of all embarkation deck lighting.
Lifesaving
Issued 16 June 2000
Resolved
Provide first sid kit for rescue boat.
Electrical
Issued 16 June 2000
Resolved
Repair electrical connection boxes for both sewage lift pump motors and evaporator S.w. pump.
Construction/Loadline
Issued 16 June 2000
Resolved
Label all bilge manifolds as neccesary.
Electrical
Issued 23 June 1999
Resolved
Prove proper operation of reverse power relay for #4 main generator to satisfaction of attending CG inspector or ABS surveyor. #4 generator not to be operated unless machinery space is manned.
Documentation
Issued 23 June 1999
Resolved
Provide proof of compliance with personnel chemical testing regulations (DAPI).
Engineering
Issued 23 June 1999
Resolved
Prepare & make available #1-4 main generators jacket water high temp alarm systems for testing in the presence of CG MI. C/E to purchase/install dry wells for temp sensors to permit this & future tests.
Lifesaving
Issued 23 June 1999
Resolved
Repair/replace chafed 120 V electrical wire to receptacle, port side, main deck, below crane.
Fire Fighting
Issued 23 June 1999
Resolved
Fire detection panel on bridge: provide bulbs for "POWER and alarm # "2".
Lifesaving
Issued 5 August 1998
Resolved
"FREE-UP" RELEASES ON PORTABLE GAS CONTAINER SLIDE USED FOR SCUTTLING PORTABLE GAS CONTAINERS IN EVENT OF FIRE. BOLTS ON SLIDE DOOR RELEASE ARE RUSTED OVER & HINGES PAINTED TIGHT.
Fire Fighting
Issued 5 August 1998
Resolved
MAKE FULLY OPERABLE/CLOSEABLE FOLLOWING FIRE SCREEN DOORS:_x001C_ 01-28-0, 2-23-0, 1-28-0. CURRENTLY DOORS DO NOT COME TO COMPLETE CLOSED POSITION AND ARE IN NEED OF READJUSTMENT.
Fire Fighting
Issued 5 August 1998
Resolved
DEVISE MEANS OF SECURING VENTILATION TO 2 AFT PAINT LOCKERS UPON RELEASE OFFIXED FIREFIGHTING SYSTEM.
Electrical
Issued 1 July 1997
Resolved
Remove deadend wires in overhead compt 01-56-0.
Accommodation/Occupational Safety
Issued 1 July 1997
Resolved
Complete repairs to #2 A/C compressor motor.
Accommodation/Occupational Safety
Issued 1 July 1997
Resolved
Hydrostatistically test air receivers SEA 82290/82295/82315/82275 and pressure test respective relief valves in presence of CG marine inspector.
Engineering
Issued 1 July 1997
Resolved
Prove proper shutdown of #1 MDE on both loss of lube oil and halon release in presence of CG marine inspector.
Electrical
Issued 1 July 1997
Resolved
Perform overspeed, lube oil shutdown and high water temperature alarm testson emergency generator in presence of CG marine inspector.
Accommodation/Occupational Safety
Issued 1 July 1997
Resolved
Repair stbd side steering room and storage room escape scuttle hold back mechanisms, free-up port side steering room escape scuttle.
Electrical
Issued 1 July 1997
Resolved
Mark emergency lighting in classroom.
Accommodation/Occupational Safety
Issued 1 July 1997
Resolved
Complete repairs to #1 & 2 evaporators.
Lifesaving
Issued 1 July 1997
Resolved
Jackstaff wires on fly bridge are frayed and broken at stuffing tube.
Electrical
Issued 1 July 1997
Resolved
Label lighting panel SP 107-1D.
Electrical
Issued 1 July 1997
Resolved
Remove deadend wires in winch room/after shop and cover hole in bulkhead stbd side.
Fire Fighting
Issued 1 July 1997
Resolved
Repack valve for fire station #11.
Fire Fighting
Issued 1 July 1997
Resolved
Relabel instructions for halon system in aft shop.
Lifesaving
Issued 1 July 1997
Resolved
Replace life ring light on stbd aft deck.
Accommodation/Occupational Safety
Issued 1 July 1997
Resolved
Replace missing section of railing stbd aft deck.
Electrical
Issued 1 July 1997
Resolved
Remove improper plug arrangement from outlet on forward bulkhead in after shop.
Electrical
Issued 1 July 1997
Resolved
Replace emergency light in forepeak bos'n stores.
Electrical
Issued 1 July 1997
Resolved
Replace emergency battle lantern in forepeak passageway on 01 deck.
Lifesaving
Issued 1 July 1997
Resolved
Hydro release dates on epirb releases expired.
Lifesaving
Issued 1 July 1997
Resolved
Replace lens to auto smoke release buoy on bridge.
Electrical
Issued 1 July 1997
Resolved
Remove unauthorized extension cords from cadet staterooms.
Lifesaving
Issued 1 July 1997
Resolved
Prove proper operation of public address system from pilot house.
Construction/Loadline
Issued 1 July 1997
Resolved
Prove proper operation of #1 bilge pump.
Construction/Loadline
Issued 5 September 1996
Resolved
MAKE BILGE ALARM SENSOR UNIT LOCATED IN TRANSDUCER TRUNK OPERATIONAL.
Fire Fighting
Issued 11 June 1996
Resolved
Conduct test to halon system in engine room in the presence of the attending Coast Guard Inspector._x001C_
Engineering
Issued 11 June 1996
Resolved
Prove proper operation of machinery automation system in the presence of the attending Coast Guard Inspector.
Lifesaving
Issued 11 June 1996
Resolved
Repair kick out panel for halon room._x001C_
Fire Fighting
Issued 11 June 1996
Resolved
Supply copy of fire extinguisher serviceing report._x001C_
Construction/Loadline
Issued 11 June 1996
Resolved
Make WTD leading to chart room watertight, and prove the same to the attending Coast Guard Inspector._x001C_
Lifesaving
Issued 30 June 1995
Resolved
REPLACE HYDROSTATIC RELEASE FOR THE EPRIB.
Fire Fighting
Issued 30 June 1995
Resolved
REVISE FIRE CONTROL PLAN TO ACCOUNT FOR ADDITION OF CLASS ROOM.
Fire Fighting
Issued 30 June 1995
Resolved
NUMBER ALL FIRE EXTINQUISHER LOCATIONS TO CORRESPOND WITH THE FIRE CONTROL PLAN.
Fire Fighting
Issued 30 June 1995
Resolved
REPLACE TOGGLE BOLTS ON VENTILATION INTAKE COVER PORT SIDE FWD OF CRANE.
Fire Fighting
Issued 30 June 1995
Resolved
FREE UP ALL VENTILATION INTAKE COVERS AND TOGGLE BOLTS.
Construction/Loadline
Issued 5 July 1994
Resolved
INSTALL CLASS II OR III WTD'S AS PER G-MTH-3 LTR 16715/14/9 OF 6-7-93 PRIORTO SAILING.
Accommodation/Occupational Safety
Issued 5 July 1994
Resolved
PROPERLY STENCIL, PROVIDE MEANS TO OPERATE FROM ABOVE AND PROVE PROPER OPERATION OF PORT & STBD EMERGENCY ESCAPE SCUTTLES FOR THE STEERING GEAR ROOM. VESSEL IS NOT TO OPERATE UNTIL THIS ITEM IS CLEARED.
Documentation
Issued 5 July 1994
Resolved
VESSEL IS NOT TO OPERATE UNTIL A NEW LOADING CERTIFICATE IS ONBOARD. THIS REQT CAN BE CLEARED VIA FAX TO NYCMI. [phone withheld].
Fire Fighting
Issued 5 July 1994
Resolved
CONDUCT FIRE DRILL WITH CREW PRIOR TO SAILING._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 5 July 1994
Resolved
VESSEL IS RESTRICTED TO NOT MORE THAN 40 PERSON UNTIL ALL SERVICED LIFERAFTS ARE INSTALLED ONBOARD. THE ABOVE ITEMS TO BE CLEARED BY AN ATTENDING MARINE INSPECTOR BUT NO LATER THAN 15AUG94.
Lifesaving
Issued 9 June 1993
Resolved
RE-STOW INFLATABLE LIFERAFTS SO THAT THEY ARE LESS THAN 4.5M (15 FEET) ABOVE THE WATER OR REPLACE WITH APPROVED INFLATABLE LIFERAFT DAVIT LAUNCH SYSTEM.
Construction/Loadline
Issued 9 June 1993
Resolved
INSTALL AUDIBLE ALARMS AND LIGHTS ON EACH WATERTIGHT DOOR.
Construction/Loadline
Issued 17 February 1993
Resolved
PROVE PROPER OPERATION OF OWS 15 PPM DISCHARGE MONITOR TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR. OILY WATER SEPARATOR IS NOT TO BE USED UNTIL THIS REQUIREMENT IS CLEARED.
Documentation
Issued 17 February 1993
Resolved
OBTAIN STABILITY LETTER FROM USCG AND POST ON BRIDGE.
Electrical
Issued 17 February 1993
Resolved
PROVE PROPER OPERATION OF EDG LOCAL ALARM PANEL TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 17 February 1993
Resolved
COMPLY W/PRIMARY LIFESAVING REQUIREMENTS AS PER 46 CFR 167.35-10 OR PROVIDEEQUIVALENT ARRANGEMENTS AS PER 46 CFR 167.01-20.
Construction/Loadline
Issued 16 January 1992
Resolved
EFFECT PERMANENT REPAIRS TO THE FOREPEAK BALLAST TANK TO THE SATISFACTION OF THE ATTENDING [name withheld] AT THE NEXT DRYDOCKING PERIOD.
Lifesaving
Issued 23 October 1991
Resolved
COMPLETE LIFERAFT DAVIT INSTALLATION PER DRAWINGS APPROVED BY USCG MSC ON 10OCT91 AND CONDUCT AN INSTALLATION WEIGHT TEST TO THE SATISFACTION OF THE COGNIZANT [name withheld] THE DAVITS WITH PERSONS IN A LIFERAFT AND NOTLATER THAN 06 JUNE 1992.
Lifesaving
Issued 2 July 1991
Resolved
SUBMIT AS-BUILT ENGINEERING DRAWINGS OF PORT AND STARBOARD LIFERAFT DAVIT FOUNDATIONS TO THE COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL.
Electrical
Issued 6 June 1990
Resolved
SHOW CORRECT OPERATION OF THE PORT AND STBD REMOTE EMERGENCY PUMP SHUTDOWNSFOR THE OILY BILGE OVERBOARD PUMP PRIOR TO GETTING UNDERWAY.
Electrical
Issued 6 June 1990
Resolved
REPAIR / RENEW ELECTRICAL CONTROLLER BOX COVER FOR THE FOREWARD CAPSTAN AND THE AFT PORT CAPSTAN.
Electrical
Issued 6 June 1990
Resolved
PROVIDE AND SHOW PROPER OPERATION OF LOW LUBE OIL PRESSURE ( 30 PSI APPROX)ALARM FOR EMERGENCY GENERATOR.
Electrical
Issued 6 June 1990
Resolved
PROPERLY MARK ALL PAINTED OVER "E" DESIGNATIONS FOR EMERGENCY LIGHTING LOCATED IN ALL MACHINERY AND ENGINEERING SPACES.
Engineering
Issued 6 June 1990
Resolved
RELOCATE "KEY" AND LABEL, TO PORT CORRIDOR LONG BULKHEAD BETWEEN FO AND LO REMOTE VALVE CLOSURE FITTINGS PRIOR TO VESSEL GETTING UNDERWAY.
Engineering
Issued 6 June 1990
Resolved
CALIBRATE ALL CONSOLE GAGES AND ENGINE MOUNTED GAGES NOT RENEWED THIS INSPECTION.
Construction/Loadline
Issued 6 June 1990
Resolved
RENEW SHAFT AND DOG ON HATCH 1-10-2.
Fire Fighting
Issued 6 June 1990
Resolved
PROVIDE (2) TWO COAST GUARD APPROVED SELF CONTAINED BREATHING APPARATUS PRIOR TO VESSEL GETTING UNDERWAY.
Engineering
Issued 6 June 1990
Resolved
(CONT) BLST TK 3-94-2, AF PEAK BLST TK 3-94-1, VENT LOCATED FWD OF FWD AFT PEAK BLST TK 3-94-1, VENT DIRECTLY AFT (NO LABEL) OF VOID 4-34-0, 8 VENTS ON FORECASTLE (EXCEPT FOR FWD MOST STBD VENT).
Engineering
Issued 6 June 1990
Resolved
CONDUCT VESSEL AUTOMATION PROCEDURE - SECTION II (D) "PROPULSION POWER LIMITING" FIRST AVAILABLE TIME AFTER GETTING UNDERWAY AND NOTIFY MSO HONOLULU OF ITS SATISFACTORY TEST COMPLETION.
Engineering
Issued 6 June 1990
Resolved
REPAIR/RENEW THE FOLLOWING TANK VENT BALL CHECK AND FLAME SCREEN: BLST TK 4-24-0, BLST TK 4-23-3, BLST TK 4-24-3, XDCER TRUNK 4-31-1, FO TK 4-52-0, FO TK 4-52-1, FO SER TK 4-52-3,FO TK 4-18-0, BLST TK 4-24-0 & 4-24-2, LUBO TK 4-60-2, SEWAGE LIFT STA #5 (OUTBOARD), BLST TK 4-86-2, AFT PEAK (CONT)
Lifesaving
Issued 27 November 1989
Resolved
MOVE OR INSTALL DECK LIGHTING FROM 02 TO 01 DECK TO PROPERLY ILLUMINATE LIFERAFT EMBARKATION AREAS AND PROPERLY INSTALL EMBARKATION LADDERS.
Construction/Loadline
Issued 27 November 1989
Resolved
PROVIDE MINIMUM 1 BBL. CAP. FIXED CONTAINMENT FOR ALL FUEL VENTS AS REQUIRED BY RECENT TONNAGE INCREASE OUTLINED IN MILITARY SEALIFT COMMAND LTR 20JUN89.
Construction/Loadline
Issued 25 August 1989
Resolved
PERMANENTLY REPAIR BOTTOM PLATE IN WAY OF BALLAST TANK #4-86-2 SOUNDING TUBE, WHERE DOUBLER PLATE IS NOW INSTALLED.
Navigation
Issued 14 May 1987
Resolved
PROVIDE AN UP TO DATE MAGNETIC DEVIATION TABLE FOR THE PILOT HOUSE.
Lifesaving
Issued 14 May 1987
Resolved
PROVIDE TWO ROCKETS TO BRING THE ON BOARD NUMBER UP TO THE REQUIRED COMPLEMENT FOR THE LINE THROWING APPLIANCE.
Lifesaving
Issued 14 May 1987
Resolved
PROVIDE ONE ADDITIONAL COAST GUARD APPROVED HAND HELD ROCKET PROPELLED, PARACHUTE DISTRESS SIGNAL.
Lifesaving
Issued 14 May 1987
Resolved
PROVIDE A BOX OF PRIME EJECTOR CARTRIDGES FOR THE LINE THROWING APPLIANCE.
Engineering
Issued 14 May 1987
Resolved
PROVIDE A MARPOL STANDARD SLOP CONNECTION IN ACCORDANCE WITH THE IOPP CERTIFICATE FORM SURVEY.
Engineering
Issued 14 May 1987
Resolved
REPAIR AND DEMONSTRATE THE SAREX OILY WATER SEPARATOR AND THE BA-1 BILGE ALARM.
Engineering
Issued 14 May 1987
Resolved
REPAIR AND DEMONSTRATE THE PORT MAIN MOTOR AUTOMATIC SHUTDOWN ALARM PRINT- OUT ON THE CRT.
Engineering
Issued 14 May 1987
Resolved
REPAIR AND DEMONSTRATE THE EMERGENCY SHUTDOWN SWITCH FOR THE FUEL OIL AND LUBE OIL PURIFIER.
Engineering
Issued 14 May 1987
Resolved
REPAIR AND PROVE SATISFACTORY OPERATION OF THE NUMBER 3 SHIPS SERVICE DIESEL LOW LUBE OIL ALARM. UNTIL REPAIR IS AFFECTED, USE OF THIS GENERATORIS RESTRICTED TO MANNED ENGINEROOM OPERATION.
Engineering
Issued 14 May 1987
Resolved
ADJUST THE PRESSURE DIFFERENTIAL OF THE SET POINTS ON THE PRESSURE SWITCH FOR THE LOW LUBE OIL ALARM AND THE TRIP ON ALL FOUR MAIN DIESEL ENGINES. ADJUSTMENT IS NECESSARY TO PROVIDE A WARNING TO THE ENGINEERS OF AN IMPENDING TRIP OF THE ENGINES.
Fire Fighting
Issued 14 May 1987
Resolved
PROVIDE AN UL, FM, OR CSA LABELED OXYGEN/COMBUSTIBLE GAS DETECTOR FOR THE FORWARD EMERGENCY GEAR LOCKER.
Unknown
Issued 29 May 1986
Resolved
DOCUMENT COAST GUARD APPROVAL OF PLANS AND INSTALLATION OF THE FIXED FIRE EXTINGUISHING FOR THE POINT LOCKER.
Unknown
Issued 29 May 1986
Resolved
DEMONSTRATE PORT AND STARBOARD PROPULSION SYSTEM ABNORMAL ASSIGNMENT FUNCTION OF THROTTLE CONTROLS.
Unknown
Issued 29 May 1986
Resolved
DEMONSTRATE OILY WATER SEPARATOR OPERATION.
Unknown
Issued 29 May 1986
Resolved
PROVIDE OIL POLLUTION PLACARD.
Unknown
Issued 29 May 1986
Resolved
REPAIR OR REPLACE FLOAT LIGHT FOR THE RING BUOY LOCATED ON THE STARBOARD SIDE, AFT.
Unknown
Issued 29 May 1986
Resolved
REPAIR AFTER MOST O2 DECK, WEATHER DECK GENERAL ALARM.
Construction/Loadline
Issued 16 August 1985
Resolved
MAKE VESSEL AVAILABLE FOR REINSPECTION BY A COAST GUARD MARINE INSPECTOR TO CHECK THE CRACKED WELDS ALONG FRAME 54.
Construction/Loadline
Issued 16 August 1985
Resolved
MAKE PERMANENT REPAIRS TO THE CRACKED WELDS ALONG FRAME 54 BY THE NEXT SCHEDULED DRYDOCKING OF VESSEL BUT NO LATER THAN 01MAY86.
Engineering
Issued 2 May 1985
Resolved
PROVE PROPER OPERATION OF THE DC POWER FILTERS THAT ARE PRESENTLY DISCONNECTED OR REMOVE THEM FROM THE VESSEL.
Electrical
Issued 2 May 1985
Resolved
PROVE PROPER OPERATION OF THE #2 DIESEL EMERGENCY SHUTDOWN AT THE MAIN CONTROL STATION.
Fire Fighting
Issued 2 May 1985
Resolved
PROVE PROPER OPERATION OF THE HALON TIME DELAY FOR THE BOW THRUSTER SPACE.
Lifesaving
Issued 2 May 1985
Resolved
PROVIDE A POWER WINCH FOR THE RESCUE BOAT DAVIT.
Accommodation/Occupational Safety
Issued 2 May 1985
Resolved
PROVIDE HAND RAILS AT THE PERIPHERY OF THE DECK IN WAY OF THE RESCUE BOAT WITH A MINIMUM HEIGHT OF 39 1/2 INCHES.
Electrical
Issued 2 May 1985
Resolved
PROVIDE USCG APPROVED DWGS. OF THE ELECTRICAL MODIFICATIONS FOR THE FOLLOWING: (A) ENGINEERING PHONE ALERT/ (B) ADD'L SOUND POWERED PHONE; (C) 24 VOLT DC POWER FOR GYRO; (D) SOC DOOR ALARM (SECURITY); (E) CNT FLOAT SWITCH;(F) SHORE POWER;(G) EMERG. DIESEL GENERATOR; (H) ADD'L LTG CIRCUITS.
Deck/Cargo
Issued 2 May 1985
Resolved
PROVE PROPER OPERATION OF BOW THRUSTER THERMO SHUTDOWN AND ALARM.
Casualty record · 5
1 June 2017Routine · role: Involved in a Marine Casualty · activity 6334932
31 July 2018Routine · role: Involved in a Marine Casualty · activity 6498113
28 June 2019Routine · role: Involved in a Marine Casualty · activity 6736832
1 March 2022Routine · role: Involved in a Marine Casualty · activity 7404350
27 July 2022Routine · role: Involved in a Marine Casualty · activity 7521941
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.