← All vessels
GASCHEM ATRICE
GASCHEM ATRICE is a 1984 tank ship. The Coast Guard has recorded 41 inspections since 1985, most recently in September 2011, along with 17 deficiencies and 6 operational controls.
Records from 1985 to 2011. Most recent: inspection, 8 September 2011.
- Built
- 1984
- Last inspected
- 8 September 2011
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8324634 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELQR3
247138
Flag
GERMANY
—
Maury page id
psix-247138
Inspections, by type
…with no type recorded15
Years with a record
18 calendar years (1985–2011)
The 41 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6755 - Convention (Subpart B), Gross Ton
8711 - Dead Weight, Ton
12592 - Displacement, Ton
2026 - Convention (Subpart B), Net Ton
8711 - Dead Weight, Ton
12592 - Displacement, Ton
2026 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 41
8 September 2011
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4139301
24 August 2011
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4119383
29 June 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3251337
7 April 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3179167
3 March 2008
ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3157499
28 January 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3137721
3 January 2008
MARPOL Annex I Examination · COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3131332
3 August 2006
Ballast Water Examination · COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2695090
27 May 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2660548
19 May 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2652369
23 February 2006
Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2590887
8 June 2005
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2383893
10 November 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1946914
9 November 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1945046
16 January 2003
Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1731577
15 January 2003
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1730800
30 November 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1712989
8 October 2002
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1686854
14 September 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1694836
13 September 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1675171
11 May 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 403529
28 December 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 398861
28 December 1996
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1100099
6 February 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 458468
30 May 1994
Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1171425
9 August 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 470334
18 February 1993
Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1145023
9 July 1992
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 944988
3 July 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1264905
28 June 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 351690
28 June 1992
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 947009
28 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339026
28 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233683
27 February 1989
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 895326
19 February 1989
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1200659
24 December 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1039533
8 June 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 441044
6 April 1987
MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1328443
2 February 1987
Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1011449
11 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 308048
24 April 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 301802
Deficiency record · 17
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1-Routine Visual Inspections
Issued 24 August 2011
Resolved
0199-Other (Certificate) -Master unable to produce record of visual inspections. [email withheld]
Deck/Cargo › Cargo Stowage
Issued 8 October 2002
Resolved
Vessel unable to demonstrate proper calibration and testing of the fixed Moss Gas Detection System. LEGACY COMPONENT DESC: Moss Gas Detection System
Deck/Cargo
Issued 28 December 1996
Resolved
REPAIR OR REPLACE TWO(02) DECK SPRAY NOZZLES ON THE FORECASTLE ABOVE THE DOOR TO THE PAINT LOCKER.
Documentation
Issued 30 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Deck/Cargo
Issued 28 June 1992
Resolved
MAKE REPAIRS AS NECESSARY AND PROVE PROPER OPERATION OF VESSELS INERT GAS GENERATOR TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Engineering
Issued 28 August 1990
Resolved
INSTALL FLAME SCREENS IN BUNKER VENTS STBD SIDE OF DECKHOUSE PRIOR TO THE NEXT U.S. VOYAGE.
Deck/Cargo
Issued 28 August 1990
Resolved
STENCIL CARGO LINES "LIQUID" OR "VAPOR" AS APPROPRIATE PRIOR TO THE NEXT U.S. VOYAGE.
Electrical
Issued 28 August 1990
Resolved
RENEW GLOBE IN EXPLOSION PROOF LIGHT AT STBD BUNKER STATION PRIOR TO THE NEXT U.S. VOYAGE.
Documentation
Issued 28 August 1990
Resolved
PROVIDE COPIES OF 46 CFR PARTS 35 AND 154 ON BOARD IN ACCORDANCE WITH 46CFR154.1806 PRIOR TO THE NEXT U.S. VOYAGE.
Deck/Cargo
Issued 28 August 1990
Resolved
EFFECT REPAIRS AND PROVE OPERATION OF GAS DETECTION SYSTEM AUDIBLE ALARM ON BRIDGE IN ACCORDANCE WITH 46CFR154.1350 AT NEXT U.S. VOYAGE.
Navigation
Issued 19 February 1989
Resolved
REVISE MANEUVERING INFORMATION FACT SHEET TO CONTAIN INFORMATION REQUIRED BY 33 CFR 164.35(G)(1)(5)(6)(7) PRIOR TO NEXT U.S. VOYAGE.
Deck/Cargo
Issued 19 February 1989
Resolved
PRIOR TO CARRYING CARGOES WHICH REQUIRE INERTING, PROVE PROPER OPERATION OFINERT GAS SYSTEM TO COGNIZANT [name withheld] NO LATER THAN UPON ARRIVAL AT NEXT U. S. PORT.
Deck/Cargo
Issued 19 February 1989
Resolved
PROVE PROPER OPERATION OF OIL DISCHARGE MONITOR & CONTROL ALARMS PRIOR TO DEPARTING THE PORT OR HOUSTON, TO COGNIZANT OCMI.
Deck/Cargo
Issued 19 February 1989
Resolved
PROVIDE SUFFICIENT SPAN GAS FOR CALIBRATING GAS DETECTION SYSTEM PRIOR TO NEXT U.S. VOYAGE.
Lifesaving
Issued 11 April 1986
Resolved
PROVIDE ONE ADDITIONAL STRETCHER OR WIRE BASKET IAW 46CFR154.1420. ONLY ONE ON BOARD.
Navigation
Issued 11 April 1986
Resolved
PROVIDE DIAGRAM & INSTRUCTIONS FOR REMOTE STEERING GEAR POWER/CONTROL SYSTEM CHANGEOVER, POSTED ON BRIDGE AND IN STEERING GEAR COMPARTMENT IAW 33CFR164.35(K).
Documentation
Issued 11 April 1986
Resolved
VESSEL DID NOT HAVE ANY OIL TRANSFER PROCEDURES FOR BUNKERING OPERATIONS ASREQUIRED BY 33CFR155.720.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.