MAURY USCG vessel records Sign in
← All vessels

SINO PIONEER

SINO PIONEER is a 1977 freight ship. The Coast Guard has recorded 25 inspections since 1985, most recently in March 2003, along with 7 deficiencies and 3 operational controls.

Records from 1985 to 2003. Most recent: operational control imposed, 1 March 2003.

Built
1977
Last inspected
1 March 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7526182 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
247207
Flag
UNKNOWN
—
Maury page id
psix-247207

Inspections, by type

…with no type recorded21
Years with a record 16 calendar years (1985–2003)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it16834 - Regulatory (Subpart C or D), Gross Ton
27461 - Dead Weight, Ton
8362 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

1 March 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1751276
3 January 2003 Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1725121
2 July 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1640473
28 May 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1621628
19 December 2001 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1474375
18 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 285981
24 January 1999 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 424856
6 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 411392
19 August 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 30783
4 November 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 397105
5 April 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 388382
14 October 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384108
12 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 373389
12 December 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1150937
30 September 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 361165
7 December 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 114369
6 February 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 476374
22 May 1991 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 343916
27 June 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 331284
22 June 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 476705
6 January 1988 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 320524
29 November 1986 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 313032
15 May 1986 Type not recorded
No type recorded · COTP NEW HAVEN · USCG Northeast District (CGD-NE) · Activity 484730
27 June 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 302863
11 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 300824

Deficiency record · 7

Documentation
Issued 18 January 2001 Resolved
NON-CONFORMATIES AND THEIR POSSIBLE CAUSES NOT REPORTED AS REQUIRED BY ISM.VESSEL DID NOT REPORT CONDITIONS OF SCBA'S AND SPARES.
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Fire Fighting
Issued 18 January 2001 Resolved
LOW LEVEL ALARMS FOR BOTH SCB'S INOPERABLE._x001C_
Condition: Unknown
Due 19 January 2001
Resolved 19 January 2001
Engineering
Issued 6 January 1998 Resolved
REMOVE SOFT PATCH AND MAKE PERMANENT REPAIRS TO COOLING WATER LINE ON VALVE HOUSING FOR GENERATOR OVERBOARD LINE STBD SIDE ENGINE ROOM TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 16 March 1998
Resolved 16 March 1998
Electrical
Issued 14 October 1995 Resolved
Prior to next U.S. port provide Protective Globes for lighting fixtures in Steering Gear Room.
Condition: Unknown
Due 5 April 1996
Resolved 5 April 1996
Lifesaving
Issued 12 December 1994 Resolved
NO WEAK-LINKS ON LIFERAFTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 December 1994
Resolved 19 December 1994
Electrical
Issued 12 December 1994 Resolved
INSTALL EXPLOSION-PROOF LIGHTING IN SECONDARY PAINT LOCKER.
Condition: Unknown
Due 12 January 1995
Resolved 19 December 1994
Navigation
Issued 6 January 1988 Resolved
A VIO OF 33CFR164.30 IN THAT THE U.S. COAST PILOT,VOL.3 USED BY THE VSL WASNOT CORRECTED TO NTM 05/87,WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO PHILA.,PA.
Condition: Unknown
Due 15 December 1994
Resolved 15 December 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.