MAURY USCG vessel records
← All vessels

MAJ BERNARD F FISHER

MAJ BERNARD F FISHER is a 1985 freight ship. The Coast Guard has recorded 33 inspections since 2016, most recently in July 2026, along with 36 deficiencies, 1 operational control and 6 casualty investigations between 2003 and 2025.

Records from 2003 to 2026. Most recent: inspection, 20 July 2026.

Built
1985
Last inspected
20 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 July 2026
…with no type recorded11
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8320559
247275
Flag
UNITED STATES
Maury page id
psix-247275

Documentation record

Registered dimensions (L × B × D)612.0 ft × 105.6 ft × 67.1 ft
Registered tonnagegross 34,318 / net 10,295
ITC dimensions (L × B × D)612.0 ft × 105.6 ft × 67.1 ft
ITC tonnagegross 34,318 / net 10,295
BuilderODENSE STEEL SHIPYARD INC · ODENSE, DENMARK · built 1985
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portDOVER, DE
Trade endorsementsRegistry
DocumentationValid · issued 21 October 2025 · expires 30 November 2026
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it34318 - Convention (Subpart B), Gross Ton
10295 - Convention (Subpart B), Net Ton
34100 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 33

20 July 2026 MTSA/ISPS Verification · Vessel Attendance · ACP Annual Oversight · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8433393
27 February 2026 VRP Review
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 8318368
4 August 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8202654
27 July 2025 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 8195275
25 July 2025 ACP Periodic Oversight · Periodic Inspection · MTSA/ISPS Verification
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8173726
17 July 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8333794
28 March 2025 Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 8255073
14 November 2024 Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 8025474
28 June 2023 ISM Oversight · ACP Annual Oversight · Administrative Inspection · MTSA/ISPS Verification · Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7725313
14 April 2023 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7669417
31 October 2022 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 7586354
12 August 2022 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7527751
12 August 2022 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7531416
3 August 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7524564
2 May 2022 Deficiency Check · Re-Inspection · Administrative Inspection · ACP Drydock Oversight · ACP COI Oversight
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7442512
11 April 2022 Explosive Handling Operation-Military
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7428657
9 November 2021 Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7347763
28 June 2021 Administrative Inspection
Administrative · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 7237690
3 December 2020 Annual Inspection · ACP Annual Oversight · Administrative Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 7098235
23 April 2020 Administrative Inspection
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 6943159
10 September 2019 Periodic Inspection · ACP Periodic Oversight · MTSA/ISPS Verification · Administrative Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6784981
16 April 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6742629
6 August 2018 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Inspections Unit Singapore · USCG Oceania District (CGD-O) · Activity 6502024
13 July 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6208020
12 July 2017 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 6206484
1 May 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6136242
19 April 2017 MTSA/ISPS Verification · Administrative Inspection · COI Inspection · Special
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6128304
20 September 2016 Annual Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 6004781
23 June 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6110567
18 June 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5911255
17 June 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5938527
3 June 2016 Administrative Inspection · ACP Periodic Oversight
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5896603
3 June 2016 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5896785

Deficiency record · 36

07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2025 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignitability of combustible materials shall be restricted. Several oil soaked absorbent pads across were found on the bottom two decks of the bow thruster compartment spanning 30 sq/ft posing a fire hazard. Remove absorbent pads.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 2 August 2025
Resolution: Crew removed absorpent pads.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 25 July 2025 Resolved
For periodically unattended machinery spaces, the Administration shall give special consideration to maintaining the fire integrity of the machinery spaces. The Class A fire door from the engine room into the fan space improperly closed and was unable to latch from self-closing configuration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 2 August 2025
Resolution: Vessel repaired fire door.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 25 July 2025 Resolved
Electrical installations shall be such that: electrical services essential for safety will be ensured under various emergency conditions. Various emergency lighting bulbs were found extinguished during the ship’s walk through round including in the bow thruster space, laundry, and the ships office.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 2 August 2025
Resolution: Crew replaced electrical lighting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 July 2025 Resolved
Electrical installations shall be such that: the safety of passengers, crew and ship from electrical hazards will be ensured. The vessel had a container arranged aft of the house utilized as a workbench with 4 daisy chained portable electrical extension cords powering multiple lighting installations from a shared power strip into a shared outlet junction positioned beneath the container posing a fire hazard. Replace portable electrical installation with a fixed configuration appropriate for the electrical draw of the lighting installations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 2 August 2025
Resolution: Crew removed daisy chained portable electrical cords.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 25 July 2025 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The #3 cargo hatch cover on the starboard side at bay #10 had air hissing from the hatch gasket and requires investigation if seal is fit for purpose or requires servicing/replacement.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 2 August 2025
Resolution: Class required permanent repairs of No. 3 hatch cover gasket by 09-02-20025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 July 2025 Resolved
Waste receptacles shall be constructed of non-combustible materials with no openings in the sides or bottom. Attending MI’s noted that plastic garbage cans were utilized for the storage of flammable or combustible rags in the Paint Locker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2025
Resolved 2 August 2025
Resolution: Waste receptables were replaced.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 August 2023 Resolved
Adequate arrangements shall be in place to ensure performance of equipment is maintained. MIs noted bridge panel for light controls with multiple bulbs burned out and no ability to distinguish which deck lights were energized. Satisfactory repairs w/in 30 days to RO.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 August 2023 Resolved
Inspections of the fire safety systems and appliances shall include review of fire control plans and stowage of gear as approved. MIs noted discrepancies with the classification of spaces (slop stores listed on plan but was the fire locker (FE - FSD 616 main deck). Fire control plan shall be revised and equipment stowage verified by RO.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 1 August 2023 Resolved
Conditions of ship shall be maintained to ensure safety and fitness to proceed to sea. Main engine room overhead hatch (main deck) found with wasted corner and unauthorized temporary repair. RO to verify condition and acceptance of temporary repair while awaiting crop/renew (concerns w/ hot work on deck due to cargo load).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 1 August 2023 Resolved
Fireman's outfits shall consist of boots of rubber or nonconducting material. Boots for FF outfits found wasted and not in working condition. Damaged boots shall be identified for all suits and replaced with adequate sizes for the assigned fire teams.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2023 Resolved
Machinery, associated piping systems and fittings shall be adequate for the service for which they are intended. MIs noted Ballast/FM control panel in CCR with numerous burnt bulbs, valves in open & closed condition error, handwritten notes for missing valves in diagram, and faulty remote controls. System repairs & service tech support is required for system grooming and restore remote controls.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Communication-SOLAS chap. 5
Issued 1 August 2023 Resolved
At least two independent means shall be provided for communicating orders from the nav bridge to the position in the machinery space where the engines are normally controlled; one of which shall be an engine-room telegraph (EOT). MIs noted alignment issues with the EOT controls during testing between the bridge and ECR. Satisfactory repairs due to correct EOT w/in 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 August 2023 Resolved
A self-contained emergency source of electrical power shall be provided in cargo ship. MIs noted emergency generator issues during operation requiring replacement of fuel supply hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 August 2023 Resolved
Fixed fire detection required and shall provide clear information to each indicating unit about the spaces covered and location of the sections in alarm. Ship self-reported fire detection panel in ECR w/ nuisance summary alarm impacting ACCU alarms and notification of fire zone impacted. Technician support require to clear ECR fire summary alarm.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 August 2023 Resolved
Ventilation shall be maintained in working order for machinery spaces. Ventilation fan in the main deck (aft) battery room was found inop and requires replacement w/ adequate size motor.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 1 August 2023 Resolved
Condition of ship shall be maintained. Ballast vent piping (specifically Cargo holds 6/7) found w/ pin holes & deteriorated condition. Vent pipes shall be repaired.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 1 August 2023 Resolved
Condition of ship shall be maintained. WTD 806 (Hold 6/7 starboard) found with separated frame and spray foam applied to fix. Door frame adjustments required or new frame for installation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 August 2023 Resolved
Electrical equipment and wiring shall not be fitted in enclosed cargo spaces unless it is essential for operational purposes. If electrical equipment is installed in dangerous environments then it shall be of a certified safe type (intrinsically safe/explosion proof) unless capable of completely isolating energy source. Cargo holds are used for the storage of IMDG class I cargoes (explosives) - and holds are classified as Class I/Division I space. IAW DOT SP 9211, modifications to 49 CFR requirements for carriage of dangerous goods under military contracts, allowances are made for electrical equipment in hazardous locations (no mention of certified safe type) but stipulates that equipment must be totally isolated while cargo is being loaded/onboard/discharge. MIs noted cargo hold electrical equipment with multiple issues: light enclosures damaged, missing latches for explosion proof enclosures, dead end wiring, sealing glands exposed, wiring for temperature/humidity sensors exposed. Thorough inspection of electrical equipment in cargo hold spaces required with satisfactory repairs to restore condition of equipment/wiring. Cargo hold lighting to be isolated (breakers locked) until repaired
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 1 August 2023 Resolved
Safety management system onboard shall be maintained iaw ISM code. MIs noted discrepancies with ship's lock out/tag out procedures for equipment onboard. RO to verify implementation of lock out/tag out SMS procedures onboard and effectiveness of program.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Echo sounder
Issued 3 August 2022 Resolved
All ships of 300 gross tonnage and upwards be fitted with an echo-sounding device, or other electronic means, to measure and display the available depth of water. MI observed the display was not readable. IAW 33 CFR164.53 a Letter of Deviation is required by the OCMI of the vessel's next U.S. Port. 74 SOLAS V/19.2.3 16A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Echo sounder was readable but not crystal clear and could not be improved. Technician attended vessel, pulled and cleaned PCB board contacts and reinstalled, echo sounder display crystal clear.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 August 2022 Resolved
Maintenance, testing, and inspection of life-saving appliances shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring reliability of such appliances. MI observed fiberglass damage to the Port Life Boat. The damage was on the fwd Starboard side. MI observed a quarter size hole on the cabin top on the Starboard side Life Boat. MI observed an engine exhaust leak on the Port side Life Boat. 74 SOLAS III/ 20.3.1 16A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Port life boat quarter sized hole corrected using fiberglass repair kit, areas dried, sanded, cleaned, fiberglass matting applied, resin applied and painted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 3 August 2022 Resolved
Machinery shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. MI observed an exhaust leak on the Port side Life Boat. 74 SOLAS II-1/26.1 16A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Port lifeboat was ran with lagging removed finding no exhaust leaks. Exhaust smell believed may have been caused by heating of recently replaced engine exhaust insulation during engine testing.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 3 August 2022 Resolved
Inspected vessels are issued a Certificate of Inspection (COI) which indicates the minimum complement of officers and crew (including lifeboatmen) considered necessary for safe operation. The vessel's COI serves as the minimum safe manning document under SOLAS Chapter V, Regulation 14. A person may not employ or engage an individual, and an individual may not serve in a position in which it is required by law or regulation that the individual hold an MMC endorsed with a national endorsement, as well as a corresponding STCW endorsement for service outside the boundary line per 46 CFR 15.401. Each person serving as an able seaman on a seagoing vessel subject to the STCW Convention must also hold an STCW endorsement as able seafarer-deck. Each person serving as an RFPNW on a seagoing vessel of 500 GT or more, subject to the STCW Convention (incorporated by reference, see § 15.103 of this part), must hold an STCW endorsement attesting to his or her qualifications to perform the navigational function at the support level. The vessel’s COI requires a minimum of (3) Able Seaman and (3) additional Able Seaman are required under the “Conditions of Operation” tab as maintenance personnel. (02) of the maintenance Able Seaman are permitted to be Ordinary Seaman so long as they are endorsed for STCW II/4, rating forming part of a navigation watch, and also have the minimum training identified in NVIC 3-83. The vessel is currently manned with (03) Able Seaman and (02) Ordinary Seaman. The (02) Ordinary Seaman do not have the STCW II/4 endorsement for RFPNW. The vessel is sailing short of the minimum manning complement required by the COI. (03) additional Able Seaman personnel or (01) Able Seaman and (02) Ordinary Seaman with appropriate STCW endorsements shall be added to the manning complement in accordance with the COI prior to sailing on a foreign voyage. It is the responsibility of the owner, charterer, managing operator, master, or person in charge or in command of the vessel to ensure that appropriate personnel are carried to meet the requirements of the applicable navigation and shipping laws and regulations per 46 CFR 15.105. 74 SOLAS (20) V/14 702 C
Action required: 702 - Prior to embarking on international voyage
Resolved 20 July 2023
Resolution: Minimum manning verified onboard during 2023 ACP Annual oversight
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 August 2022 Resolved
After any survey of the ship under Regs 7,8,9, or 10 of this Chapter has been completed, no change shall be made in the structural arrangements, machinery, equipment, etc. covered by the survey, without the sanction of the Administration. Identified a corroded and holed cargo tank longitudinal stiffner on the starboard side of the #7 cargo tank top. Corrosion and three holes measured approximately 1" in diameter. 74 SOLAS (20) I/11 (b) 16 A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2022
Resolved 6 August 2022
Resolution: #7 cargo hold coaming horizontal stiffener was repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 August 2022 Resolved
All exposed metal parts of electrical machines or equipment which are not intended to be live but are liable to become live under fault conditions shall be earthed and all electrical apparatus shall be so constructed and so installed that danger of injury in ordinary handling shall not exist. Identified missing or incorrectly installed front covers to the distribution panels located in the port tunnel next to cargo tanks 7 and 8. Electrical conductors were found exposed which may cause injury if live and contacted by personnel. 74 SOLAS (81) II-1/ 27 16A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2022
Resolved 6 August 2022
Resolution: The distribution panel covers were properly returned to proper position and secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 August 2022 Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended... Identified main diesel engine jacket water pump mechanical seal leaking jacket water. 74 SOLAS (81) II-1/26.1 16 A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Main engine fresh water pump #2 was only stopped and restarted, no repair. The mechanical seal re-seated itself and stopped leaking.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 3 August 2022 Resolved
In all ships, fire-extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. Identified missing safety caps on the head units throughout the ships fixed CO2 systems. 74 SOLAS (81) II-2/21 16A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Deficiency accepted by Det Norske Veritas used Job Id as finding number.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2022 Resolved
Exposed metal parts of electrical machines or equipment which are not intended to be live but which are liable under fault conditions to become live shall be earthed. MI observed a ground fault on the 24VDC panel on the switchboard located in the Emergency Diesel Generator compartment. 74 SOLAS (81) II-1/45.1.1 16 A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Deficiency accepted by Det Norske Veritas used Job Id as finding number.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 3 August 2022 Resolved
In all ships, fire extinguishing appliances shall be kept in good order and available for immediate use at all times during the voyage. MI observed #1 fire pump check valve located on the outlet side leaking at the flange. Ships crew identified three loose bolts on the flange and tightened correcting the leaking flange on the spot. 74 SOLAS (81) II-2/21 10 C
Action required: 10 - Deficiency Rectified
Due 3 August 2022
Resolved 3 August 2022
Resolution: Ships crew identified three loose bolts on the flange where check valve is affixed and tightened correcting the leaking flange on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2022 Resolved
A main electrical lighting system which shall provide illumination throughout those parts of the ship normally accessible to and used by crew shall be supplied from the main source of electrical power. MI observed an extinguished overhead light located at the emergency fire pump electrical panel. In addition, MI observed protective cover for light fixture hanging and broken located in the overhead behind the Emergency Diesel Generator switchboard. 74 SOLAS (81) II-1/41.2.1 16A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: The broken protective cover on the light fixture behind the emergency switchboard was replaced with new cover.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2022 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. MI observed multiple extension cord daisy chains for both battery chargers running on the deck and not properly installed in the Emergency Diesel Generator compartment. 74 SOLAS (81) II-1/45.1.3 16 A
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2022
Resolved 6 August 2022
Resolution: Extension cords were removed which had previously been used to supply battery charger during the shipyard period.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 August 2022 Resolved
Maintenance of condition after survey. Vessel experienced a loss of propulsion, due to jacket water pressure drop on the #l ME cylinder, while departing the Port of Tampa. Vessel shall seek safe transit to nearest anchorage for proper assessment. Vessel shall remain at anchorage until the proper operation and/or repairs of main engine are made satisfactory to attending surveyor. Vessel must contact Sector St. Petersburg prior to departure from anchorage. SOLAS 81 Amend Ch 1 Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2022
Resolved 6 August 2022
Resolution: The RO DNV surveyor attended the vessel after repairs were made to the maine engine #1 cylinder. A satisfactory sea trial was observed by the RO and a survey report attesting to repairs was provided to USCG.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 September 2019 Resolved
Every lifeboat shall be arranged that an adequate view forward, aft, and sides is provided. Both port and stbd lifeboats have fwd facing windows that are milky white and visibility is not currently possible.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 4 October 2019
Resolution: Vsl provided proof that windows had been adequately polished so that visibility through windows were possible. Replacement windows are also on order.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 10 September 2019 Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault, precautions against such risks shall be taken to the satisfaction of the administration. Wiring going into lighting appliance no longer electrical rated for haz location. Replace/repair lighting appliance in paint locker IAW OEM.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 4 October 2019
Resolution: Vsl provided proof (pics) that lighting appliance had been replaced IAW OEM specs
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 6 August 2018 Resolved
6-man liferaft forward is mounted on a pedestal across an opening approx 1 meter wide and 2 meters high, making it a danger to safely launch. Raft to be moved to a suitable location for safe handling/launching.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2018
Resolved 30 August 2018
Resolution: Raft was moved to suitable location and now easily accessed for handling/launching.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 August 2018 Resolved
The vertical A/C ducts into cargo holds require a dedicated tool kit in the immediate vicinity, to allow for the quick removal of ducting and closing of the vent.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 September 2018
Resolved 30 August 2018
Resolution: Tool kit provided as required.

Casualty record · 6

20 March 2003Routine · role: Involved in a Marine Casualty · activity 1759835
9 October 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5743947
12 August 2022Routine · role: Involved in a Marine Casualty · activity 7531416
28 March 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8255073
17 July 2025Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 8333794
4 August 2025Routine · role: Involved in a Marine Casualty · activity 8202654
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.