MAURY USCG vessel records Sign in
← All vessels

ISLAND FANTASY

ISLAND FANTASY is a 1984 passenger vessel (inspected). The Coast Guard has recorded 10 inspections since 1985, most recently in April 1989, along with 12 deficiencies.

Records from 1985 to 1989. Most recent: inspection, 25 April 1989.

Built
1984
Last inspected
25 April 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

247293
Flag
PANAMA
—
Maury page id
psix-247293

Inspections, by type

Years with a record 5 calendar years (1985–1989)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it57 - Regulatory (Subpart C or D), Net Ton
84 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

25 April 1989 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1348925
25 April 1989 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1350383
16 June 1988 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 890383
29 April 1988 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1342940
1 March 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1332530
2 July 1987 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1010926
30 April 1987 Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1315146
10 February 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1018285
29 April 1986 COI Inspection · Credit Drydock
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301721
29 April 1985 Initial Certification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1292811

Deficiency record · 12

Lifesaving
Issued 29 April 1988 Resolved
PROVIDE & LABEL STOWAGE FOR THE ADDITIONAL 75 ADULT & 7 CHILD PFD'S.
Condition: Unknown
Due 15 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 April 1988 Resolved
REPLACE PRESSURE GAUGE TO FIRE PUMP.
Condition: Unknown
Due 15 May 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 April 1988 Resolved
PROVIDE FIRE NOZZLES THAT HAVE 1/2" ORIFICES.
Condition: Unknown
Due 30 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 29 April 1988 Resolved
PROVIDE A 300 MM. DIA. SHIP'S BELL
Condition: Unknown
Due 30 August 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 30 April 1987 Resolved
LABEL LOCATIONS OF MAIN ENGINE EMERGENCY FUEL SHUTOFF VALVES ON BULKHEAD ADJACENT TO VALVE ACCESS COVERS.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Accommodation/Occupational Safety
Issued 30 April 1987 Resolved
EFFECT PERMANENT REPAIRS TO STBD. ENGINE ROOM VENT TRUNK SO AS TO MAKE IT WEATHERTIGHT. PROVE SAME AND REMOVE PLASTIC SHEETING FROM IN FRONT OF CIRCUIT BREAKER BOXES.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Documentation
Issued 30 April 1987 Resolved
OBTAIN AND POST A VALID FCC OPERATORS LICENSE.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987 Resolved
SERVICE HYDROSTATIC RELEASES FOR BOTH INFLATABLE LIFERAFTS.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Electrical
Issued 30 April 1987 Resolved
PROPERLY WIRE ENGINE ROOM VENT FAN LOCATED IN ENGINE ROOM STBD. SIDE AFT.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Engineering
Issued 30 April 1987 Resolved
GASOLINE CONTAINERS ON STERN ARE TO BE INSTALLED IN A RACK AWAY FROM IGNITION SOURCES (E.G. FREEZER). GASOLINE MUST BE IN D.O.T. APPROVED CONTAINERS. "NO SMOKING" SIGNS MUST BE POSTED IN VICINITY.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Engineering
Issued 30 April 1987 Resolved
REMOVE ALL OIL FROM ENGINE ROOM BILGE.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Engineering
Issued 30 April 1987 Resolved
LABEL LOCATION OF GENERATOR EMERGENCY FUEL SHUTOFF VALVES.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.