MAURY USCG vessel records
← All vessels

DOWNEAST ROVER

DOWNEAST ROVER is a 1984 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in May 2026, along with 44 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 25 May 2026.

Built
1984
Last inspected
25 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 May 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2583
247307
Flag
UNITED STATES
Maury page id
psix-247307

Documentation record

Registered dimensions (L × B × D)37.3 ft × 12.3 ft × 6.2 ft
Registered tonnagegross 18 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMERRITT NEIL WATERS · NORFOLK, VA, UNITED STATES · built 1984
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMANTEO, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Regulatory (Subpart C or D), Gross Ton
17 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 27

25 May 2026 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8302849
29 May 2025 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8147080
29 April 2025 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8099960
20 June 2024 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7938745
20 June 2023 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7718903
24 April 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7672976
19 April 2022 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7426578
27 December 2021 Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7376494
13 September 2021 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7312747
19 August 2021 Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7290987
20 July 2021 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7262342
15 July 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7255939
22 April 2021 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7180030
27 August 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7043800
13 August 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7019918
28 May 2020 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6963137
4 October 2019 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6828450
30 July 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6763295
8 May 2019 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6679011
11 June 2018 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6438238
21 June 2017 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6188308
11 May 2017 Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6143700
7 December 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6071887
24 August 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5982693
27 July 2016 Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5952223
15 July 2016 Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5941696
8 April 2016 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5851985

Deficiency record · 44

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 April 2022 Resolved
COD is expire. Provide original COD once received as per 46CFR67.7.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2022
Resolution: Vaild COD onboard
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2022 Resolved
Ensure all three fire buckets are outfitted with lanyards, markings, and properly stowed as per 46CFR181.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2022
Resolution: Fire buckets are installed and marked as per CFR
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 April 2022 Resolved
Vessel is missing 02 hand orange smoke flares, provide flares as per 46CFR180.68(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: Vessel purchased new flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022 Resolved
Fuel gauge is broken on fuel filter. Replace with new or remove as per 46CFR182.20.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: New gauge installed and verified during underway operational testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022 Resolved
Properly secure cables and electrical line IVO MDE as per 46CFR183.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: Wiring properly supported.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 April 2022 Resolved
Life Ring grab lines is wasted. Replace as per 46CFR180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: New life ring installed and marked
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 April 2022 Resolved
Port running light is inoperable, replace bulb as per 33CFR83.20.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: New bulb installed still not working, cleaned paint off of contacts and nav light is watching properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2022 Resolved
Conduct satisfactory man overboard drill. Unable to conduct drill during inspection due to weather.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2022
Resolution: MOB drill conducted while underway and undersail. Drill SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 December 2021 Resolved
Canopy has multiple areas of rot and is loose at the mounts. Replace rotten canopy and enure it is properly mounted. make all repairs IAW 46CFr177.35.1(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: MI inspected fiber glass repairs and additional support brackets installed, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 December 2021 Resolved
Electrical wiring: MI Found surge proptectors dasiy chained together and a second ace hardware surge proptector appears to be permanently installed/wired directly into power panel in galley area over engine. Electrical outlet found with loose receptacles and no cover. Dead end wiring found under steps above shafting. Please make reapirs IAW 46176.35-15.
Action required: 702 - Prior to embarking on international voyage
Resolved 19 April 2022
Resolution: Cords removed and electrical outlet box has replaced the wired in power strip back to original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2021 Resolved
Fuel pull stop locking cap is cracked and held together with hose clamp at operating station. Replace and prove proper operation. Make repairs IAW 46CFr782.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: New locking cap installed and fuel pull tested, SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 December 2021 Resolved
Operation station Helm is loose. It is held on by a single nut that is no tight to the helm unit. Make repairs IAW 46CFR176.25.35(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2022
Resolution: Helm was found to be properly mounted and tight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 December 2021 Resolved
Life jacket storage location must be properly marked. With proper size (adult or child) and quanitiy IAW 46CFR180.25-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: Life jackets locations were properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2021 Resolved
Vessel MDE has a fuel leak, identify source(s) and make repairs iaw 46 CFR 182.05-1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2021
Resolution: Fuel leak secured and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2021 Resolved
Bilge Pump indicator light is inoperable at the operating station, repair/replace as necessary iaw 46 CFR 182.530(c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2021
Resolution: Indicator light now working.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 July 2021 Resolved
Bilge high level alarm is approx. 16 inches from the bilge, relocate lower in the bilge iaw 46 CFR 176.830.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: Bilge Alarm lowered. Verified on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2021 Resolved
Bilge hand pump is missing hose for de-watering, repair/replace as necessary iaw 46 CFR 182.25-10.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: pump and hose replaced with new set
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2021 Resolved
Provide on board vessel log for properly logging crew training/drills as listed in 46 CFR 185.420(c), 46 CFR 185.520(f), and 46 CFR 185.524(d) iaw 46 CFR 185.420(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: verrifed logs entered and record maintained on board
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2021 Resolved
Owner does not have a Preventative Maintenance Plan or similar that meets the recommendations laid out in NVIC 02-16. Provide third-party rigging survey that verifies condition of the sail rigging and components iaw 46 CFR 176.840.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: Cleared and reissued updated deficiency 16AUG2021.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 July 2021 Resolved
Vessel carries portable fire extinguishers in addition that required on the COI. Ensure that all onboard portable fire extinguishers are properly stored and serviced in accordance with manufacture requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: extinguishers removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2021 Resolved
Provide means for shutting off fuel supply via valve at the fuel tank from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck iaw 46 CFR 182.20-40(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: verified remote shut off arrangements now at weather deck operating station
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 August 2020 Resolved
Found deck water drain to be cracked. Repair drain.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel repaired the cracked deck water drain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2020 Resolved
Found bilge pump indicator light inoperable. Replace light and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel replaced inoperable bilge pump indicator light and proved proper operation to attending USCG Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 August 2020 Resolved
Provide drill/crew training log adequate for logging drills as listed in 46 CFR 185.420(c), 46 CFR 185.520(f), 46 CFR 185.524(d).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel supplied Log Book adequate for logging drills and training.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2020 Resolved
Found placard missing for life jacket type onboard. Add additional placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel posted Life Jacket doning placard for appropriate type of PFD.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 August 2020 Resolved
Found dead end wiring throughout vessel. Remove dead end wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel capped / removed dead end wiring throughout.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 13 August 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 27 August 2020
Resolution: Owner/Operator using different Captain(s).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 July 2019 Resolved
Lifelines were found to be loose and starboard middle lifeline had a frayed cable. Tighten lifelines and repair or replace starboard midle lifeline to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Lifelines were tightened and the frayed cable had been replaced.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 30 July 2019 Resolved
Fuel vent flame screen had holes and was painted over. Replace with a 30 x 30 flame screen to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: The painted through hole vent was actually a old MSD vent line. Fuel vent screen was found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 July 2019 Resolved
Bow lifeline stanchions and operating station awning stanchion was found to be loose. Tighten up and ensure stanchions are made secure to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Stanchions were tightened and found secure.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 July 2019 Resolved
Navigational magnetic compass was found to be frozen and not displaying proper heading. Replace or repair compass to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Verified satisfactory compass installed.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 30 July 2019 Resolved
Forward passenger bench and aft passenger bench are located close to respective booms and jib lines. Remove forward passenger bench for safety concerns or limit height of passengers who sit on the forward bench. Either lower or remove the aft passenger bench to allow for adequate head room to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Passenger benches in the fore and aft have been restricted from use. Deferred the correction to take place during dry dock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2019 Resolved
Lifebuoy does not have required retro reflective tape. Install retro to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Ring life buoy was found satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 May 2017 Resolved
Found 23 adult life preserver unserviceable; destroyed life preservers. Replace unsat pfds.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Resolution: O/O installed 23 new adult life preservers.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2017 Resolved
COD was found expired. Provide current COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Resolution: Receipt for COD payment was reviewd and present.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 May 2017 Resolved
Found coast pilot, light list, and tide tables missing. Provide publications or extracts.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Current publications have been procured and placed aboard the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017 Resolved
Found charts out dated. Provide current and corrected charts for areas of operation.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Current chart has been procured and placed aboard the vessel.
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 May 2017 Resolved
Found compass not installed. Provide satisfactory compass.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Magnetic compass has been placed back aboard the vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 May 2017 Resolved
Found line attached to ring lifebuoy frayed. Provide 60 ft of Lifeline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Ring Lifebuoy line has been replaced.
Fire Fighting › Fire Bucket › Quantity
Issued 16 May 2017 Resolved
Found 1 fire bucket missing. Provide fire bucket.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Three fire buckets have been labeled and placed on vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 July 2016 Resolved
Found Safety Radio Certificate misplaced during maintenance. MISLE shows a valid certificate with an expiration date of 10 June 2018. Produce and mount certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Provided valid Safety Radio Certificate.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 27 July 2016 Resolved
Master was unable to produce his radio operator license. Vessel operations are restricted to within 1,000 feet of shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Master provided proof of marine radio operator license.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2016 Resolved
Found first aid kit missing several items. Produced missing items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Procured required first aid items.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 July 2016 Resolved
Found aft stern light inop. Repair stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Repaired stern light.