Records from 2016 to 2026. Most recent: inspection, 25 May 2026.
Inspection history · 27
25 May 2026
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8302849
29 May 2025
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8147080
29 April 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 8099960
20 June 2024
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7938745
20 June 2023
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7718903
24 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7672976
19 April 2022
Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7426578
27 December 2021
Special
Type not classified · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7376494
13 September 2021
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7312747
19 August 2021
Administrative Inspection
Administrative · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7290987
20 July 2021
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7262342
15 July 2021
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7255939
22 April 2021
Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7180030
27 August 2020
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7043800
13 August 2020
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 7019918
28 May 2020
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6963137
4 October 2019
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6828450
30 July 2019
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6763295
8 May 2019
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6679011
11 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6438238
21 June 2017
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6188308
11 May 2017
Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 6143700
7 December 2016
Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6071887
24 August 2016
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5982693
27 July 2016
Annual Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5952223
15 July 2016
Deficiency Check
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5941696
8 April 2016
Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Nags Head · USCG East District (CGD-E) · Activity 5851985
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 April 2022
Resolved
COD is expire. Provide original COD once received as per 46CFR67.7.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2022
Resolution: Vaild COD onboard
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 April 2022
Resolved
Ensure all three fire buckets are outfitted with lanyards, markings, and properly stowed as per 46CFR181.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2022
Resolution: Fire buckets are installed and marked as per CFR
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 April 2022
Resolved
Vessel is missing 02 hand orange smoke flares, provide flares as per 46CFR180.68(b).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: Vessel purchased new flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022
Resolved
Fuel gauge is broken on fuel filter. Replace with new or remove as per 46CFR182.20.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: New gauge installed and verified during underway operational testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2022
Resolved
Properly secure cables and electrical line IVO MDE as per 46CFR183.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: Wiring properly supported.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 April 2022
Resolved
Life Ring grab lines is wasted. Replace as per 46CFR180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: New life ring installed and marked
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 April 2022
Resolved
Port running light is inoperable, replace bulb as per 33CFR83.20.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 May 2022
Resolution: New bulb installed still not working, cleaned paint off of contacts and nav light is watching properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2022
Resolved
Conduct satisfactory man overboard drill. Unable to conduct drill during inspection due to weather.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2022
Resolution: MOB drill conducted while underway and undersail. Drill SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 December 2021
Resolved
Canopy has multiple areas of rot and is loose at the mounts. Replace rotten canopy and enure it is properly mounted. make all repairs IAW 46CFr177.35.1(h)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: MI inspected fiber glass repairs and additional support brackets installed, all SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 December 2021
Resolved
Electrical wiring: MI Found surge proptectors dasiy chained together and a second ace hardware surge proptector appears to be permanently installed/wired directly into power panel in galley area over engine. Electrical outlet found with loose receptacles and no cover. Dead end wiring found under steps above shafting. Please make reapirs IAW 46176.35-15.
Action required: 702 - Prior to embarking on international voyage
Resolved 19 April 2022
Resolution: Cords removed and electrical outlet box has replaced the wired in power strip back to original.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 27 December 2021
Resolved
Fuel pull stop locking cap is cracked and held together with hose clamp at operating station. Replace and prove proper operation. Make repairs IAW 46CFr782.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: New locking cap installed and fuel pull tested, SAT.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 December 2021
Resolved
Operation station Helm is loose. It is held on by a single nut that is no tight to the helm unit. Make repairs IAW 46CFR176.25.35(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2022
Resolution: Helm was found to be properly mounted and tight.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 December 2021
Resolved
Life jacket storage location must be properly marked. With proper size (adult or child) and quanitiy IAW 46CFR180.25-15
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 April 2022
Resolution: Life jackets locations were properly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2021
Resolved
Vessel MDE has a fuel leak, identify source(s) and make repairs iaw 46 CFR 182.05-1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 July 2021
Resolution: Fuel leak secured and tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2021
Resolved
Bilge Pump indicator light is inoperable at the operating station, repair/replace as necessary iaw 46 CFR 182.530(c).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2021
Resolution: Indicator light now working.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 15 July 2021
Resolved
Bilge high level alarm is approx. 16 inches from the bilge, relocate lower in the bilge iaw 46 CFR 176.830.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: Bilge Alarm lowered. Verified on vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 July 2021
Resolved
Bilge hand pump is missing hose for de-watering, repair/replace as necessary iaw 46 CFR 182.25-10.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: pump and hose replaced with new set
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2021
Resolved
Provide on board vessel log for properly logging crew training/drills as listed in 46 CFR 185.420(c), 46 CFR 185.520(f), and 46 CFR 185.524(d) iaw 46 CFR 185.420(c).
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: verrifed logs entered and record maintained on board
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 July 2021
Resolved
Owner does not have a Preventative Maintenance Plan or similar that meets the recommendations laid out in NVIC 02-16. Provide third-party rigging survey that verifies condition of the sail rigging and components iaw 46 CFR 176.840.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: Cleared and reissued updated deficiency 16AUG2021.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 15 July 2021
Resolved
Vessel carries portable fire extinguishers in addition that required on the COI. Ensure that all onboard portable fire extinguishers are properly stored and serviced in accordance with manufacture requirements.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: extinguishers removed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 July 2021
Resolved
Provide means for shutting off fuel supply via valve at the fuel tank from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck iaw 46 CFR 182.20-40(b)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 August 2021
Resolution: verified remote shut off arrangements now at weather deck operating station
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 August 2020
Resolved
Found deck water drain to be cracked.
Repair drain.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel repaired the cracked deck water drain.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 August 2020
Resolved
Found bilge pump indicator light inoperable.
Replace light and prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel replaced inoperable bilge pump indicator light and proved proper operation to attending USCG Marine Inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 August 2020
Resolved
Provide drill/crew training log adequate for logging drills as listed in 46 CFR 185.420(c), 46 CFR 185.520(f), 46 CFR 185.524(d).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel supplied Log Book adequate for logging drills and training.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 August 2020
Resolved
Found placard missing for life jacket type onboard. Add additional placard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel posted Life Jacket doning placard for appropriate type of PFD.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 August 2020
Resolved
Found dead end wiring throughout vessel.
Remove dead end wiring.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 September 2020
Resolved 27 August 2020
Resolution: Vessel capped / removed dead end wiring throughout.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 13 August 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 27 August 2020
Resolution: Owner/Operator using different Captain(s).
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 July 2019
Resolved
Lifelines were found to be loose and starboard middle lifeline had a frayed cable. Tighten lifelines and repair or replace starboard midle lifeline to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Lifelines were tightened and the frayed cable had been replaced.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil fuel tank protection
Issued 30 July 2019
Resolved
Fuel vent flame screen had holes and was painted over. Replace with a 30 x 30 flame screen to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: The painted through hole vent was actually a old MSD vent line. Fuel vent screen was found satisfactory.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 July 2019
Resolved
Bow lifeline stanchions and operating station awning stanchion was found to be loose. Tighten up and ensure stanchions are made secure to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Stanchions were tightened and found secure.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 July 2019
Resolved
Navigational magnetic compass was found to be frozen and not displaying proper heading. Replace or repair compass to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Verified satisfactory compass installed.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 30 July 2019
Resolved
Forward passenger bench and aft passenger bench are located close to respective booms and jib lines. Remove forward passenger bench for safety concerns or limit height of passengers who sit on the forward bench. Either lower or remove the aft passenger bench to allow for adequate head room to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Passenger benches in the fore and aft have been restricted from use. Deferred the correction to take place during dry dock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 July 2019
Resolved
Lifebuoy does not have required retro reflective tape. Install retro to the satisfaction of attending USCG MI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 August 2019
Resolved 4 October 2019
Resolution: Ring life buoy was found satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 16 May 2017
Resolved
Found 23 adult life preserver unserviceable; destroyed life preservers. Replace unsat pfds.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Resolution: O/O installed 23 new adult life preservers.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 May 2017
Resolved
COD was found expired. Provide current COD.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2017
Resolution: Receipt for COD payment was reviewd and present.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 16 May 2017
Resolved
Found coast pilot, light list, and tide tables missing. Provide publications or extracts.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Current publications have been procured and placed aboard the vessel.
Navigation › Piloting/Steering › Marine Charts
Issued 16 May 2017
Resolved
Found charts out dated. Provide current and corrected charts for areas of operation.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Current chart has been procured and placed aboard the vessel.
Navigation › Piloting/Steering › Magnetic Compass
Issued 16 May 2017
Resolved
Found compass not installed. Provide satisfactory compass.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Magnetic compass has been placed back aboard the vessel.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 16 May 2017
Resolved
Found line attached to ring lifebuoy frayed. Provide 60 ft of Lifeline.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Ring Lifebuoy line has been replaced.
Fire Fighting › Fire Bucket › Quantity
Issued 16 May 2017
Resolved
Found 1 fire bucket missing. Provide fire bucket.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 21 June 2017
Resolution: Three fire buckets have been labeled and placed on vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 27 July 2016
Resolved
Found Safety Radio Certificate misplaced during maintenance. MISLE shows a valid certificate with an expiration date of 10 June 2018. Produce and mount certificate.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Provided valid Safety Radio Certificate.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 27 July 2016
Resolved
Master was unable to produce his radio operator license. Vessel operations are restricted to within 1,000 feet of shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Master provided proof of marine radio operator license.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 July 2016
Resolved
Found first aid kit missing several items. Produced missing items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Procured required first aid items.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 July 2016
Resolved
Found aft stern light inop. Repair stern light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2016
Resolved 24 August 2016
Resolution: Repaired stern light.