MAURY USCG vessel records Sign in
← All vessels

TRANSFER

TRANSFER is a 1970 freight ship. The Coast Guard has recorded 49 inspections since 1985, most recently in September 2004, along with 118 deficiencies and 7 operational controls.

Records from 1985 to 2004. Most recent: inspection, 28 September 2004.

Built
1970
Last inspected
28 September 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7124910 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
247659
Flag
CYPRUS
—
Maury page id
psix-247659

Inspections, by type

…with no type recorded36
Years with a record 15 calendar years (1985–2004)
The 49 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1723 - Dead Weight, Ton
457 - Regulatory (Subpart C or D), Net Ton
1919 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 49

28 September 2004 ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2207759
17 July 2004 ISPS II Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2136290
16 July 2004 NPV Safety Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2135340
16 July 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2139492
16 July 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2164318
30 June 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2119944
27 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2014317
17 February 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2007464
18 September 2003 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1907987
20 February 2003 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1747703
23 August 2002 Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1665597
2 July 2002 Deficiency Check · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1640639
15 May 2002 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1616973
1 May 2002 Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1612355
1 May 2002 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1626470
6 March 2002 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1491795
15 February 2002 MARPOL Annex I Examination · Ballast Water Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1486782
6 September 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 293478
7 August 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 292596
27 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 287432
24 January 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 286225
19 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 461652
10 August 2000 Port Security Assessment
Type not classified · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 583620
25 July 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 725163
7 October 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 433589
1 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 425981
15 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 421401
8 May 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 390818
26 February 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 388328
8 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381452
28 June 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 379899
9 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 368407
13 May 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 493932
19 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 365469
4 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 365336
2 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 365334
2 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1358312
1 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 364780
25 January 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 364121
7 April 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 357466
7 April 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 672704
5 January 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 355493
1 September 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 527849
21 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 474490
7 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 348832
6 January 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 348913
23 April 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 336702
11 May 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 330396
25 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 301042

Deficiency record · 118

Construction/Loadline › Hull › Bottom Plating
Issued 16 July 2004 Resolved
Prior to departure form the Houston-Galveston Zone, provide Class Survey report assesing damage to the ballast tanks and other effected areas sustained by shifting containers and provide repair plans and schedule to MSU Galveston.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 July 2004
Resolution: 22 Jul 2004: Received fax dated 21 Jul 04 from [name withheld] attesting that damage to the ballast tanks and other effected areas were repaired. Surveyor visually inspected and tightness tested. Found to be sat. See narrative.
Lifesaving › Inflatable Liferafts
Issued 17 February 2004 Resolved
Hydrostatic release on liferafts and EPIRB have not been serviced within the last 17 months. Provide proof of service prior to departure. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2004
Documentation › Certificates/Documents
Issued 20 February 2003 Resolved
LOAD LINE CERTIFICATE EXPIRED LEGACY COMPONENT DESC: Coastwise Load Line Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2003
Resolution: RECEIVED FAX FROM FLAG STATE OF VALID LOAD LINE CERTIFICATE
Personnel › Certificates/Documents/Licenses
Issued 20 February 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 21 February 2003
Resolution: LICENSE ENDORCEMENT RECEIVED FROM FLAG STATE.
Documentation › Safety Management System
Issued 2 July 2002 Resolved
DETERMINE REQUIREMENT TO TRANSLATE THE VESSLES SMS INTO THE "OFFICIAL LANGUAGE OF THE CREW" PER VESSELS FLAG ADMINISTRATION OR TRANSLATE PORTIONS OF THE SMS AND RELATED CREW FAMILURIZATION PAPERWORK INTO CREW LANGUAGE.
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 23 September 2003
Documentation › Safety Management System
Issued 2 July 2002 Resolved
AT NEXT AUDIT CONFIRM ALL SPECIFIC TRAINING TOPICS SPECIFIED IN THE SMS TRAINING SCHEDULE IS CONDUCTED AND DOCUMENTED (I.E. TRAINING PLAN AVAILABLE OR TOPIC TRAINED IS RECORDED.) LEGACY COMPONENT DESC: Emergency Drill/Exercise Programs
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 23 September 2003
Documentation › Safety Management System
Issued 2 July 2002 Resolved
POST WATCH SCHEDULE WITH APPROPRIATE REST FOR CREW PER STCW 95.
Action required: 15 - Rectify deficiencies by next port
Due 2 July 2002
Resolved 27 August 2002
Resolution: WATCH SCHEDULE IS NOW POSTED IAW STCW 95.
Documentation › Safety Management System
Issued 2 July 2002 Resolved
UPDATE SMS WITH CURRENT CHANGES. VERIFY DURING NEXT AUDIT. (MID JULY 2002)
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 23 September 2003
Navigation › Piloting/Steering
Issued 2 July 2002 Resolved
ENSURE CURRENT COPY OF 33CFR PART 164 IS ON VESSEL.
Action required: 15 - Rectify deficiencies by next port
Due 2 July 2002
Resolved 27 August 2002
Resolution: CURRENT COPY NOW ON BOARD AND ACCOUNTED FOR.
Documentation › Safety Management System
Issued 2 July 2002 Resolved
PRIOR TO NEXT US PORT AND FOLLOWING NEXT AUDIT (JULY2002) PROVIDE WRITTEN CONFIRMATION FROM RECOGNIZED ORGANIZATION ITEMS 1-5 ISSUED 02JULY2002 IN TAMPA, FL HAVE BEEN CORRECTED.
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 3 July 2002
Resolution: ISM issues are detailed to be corrected in audit by 12/16/2002.
Engineering › Compressed Air System (start air)
Issued 1 May 2002 Resolved
During manuevering the slow astern order was given and the vessel's propulsion system did not respond. Vessel allided with dock at TPA Berth #201. No significant damage resulted. Repair starting air valve and prove proper operation of propulsion in ahead and astern. Provide class report. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 May 2002
Resolved 2 May 2002
Resolution: Received sat class report. Removed vessel from Pilot hold.
Fire Fighting › Fire Pumps
Issued 15 February 2002 Resolved
FIRE PUMP IS INOPERABLE IN ENGINE ROOM, NO PRESSURE. LEGACY COMPONENT DESC: Pressure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2002
Resolution: Fire pump was replaced. Boarded vessel and attested to the replacement and witnessed an Operational test of the fire pump with two fire hoses producing adequat fire fighting prssure.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 15 February 2002 Resolved
HOSE WAS DRYROTTED. LEGACY COMPONENT DESC: Discharge Hose/Tube
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Fire Fighting › Emergency Fire Pumps
Issued 15 February 2002 Resolved
CLASS ADDRESS EMERGENCY FIRE PUMP ARRANGEMENT WITH PORTABLE PUMP ON DECK - DISCHARGE PRESSURE SAT, BUT ARRANGEMENT NEEDS CLASS APPROVAL.. LEGACY COMPONENT DESC: Location
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Documentation › Certificates/Documents
Issued 15 February 2002 Resolved
CLASS TO ADDRESS ALL PREVIOUSLY OUTSTANDING DEFICIENCIES ISSUED BY FLAG STATE DATED 24 JULY01.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Fire Fighting › Combustible Materials
Issued 15 February 2002 Resolved
REMOVE CARDBOARD BOXES AND ALL FLAMIBLE MATERIAL FROM ENGINE ROOM AND PORT SIDE SPARE PARTS STORE.
Action required: 15 - Rectify deficiencies by next port
Resolved 15 February 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 15 February 2002 Resolved
PROVE PROPER OPERATION OF PORT AND STBD F/O SHUTOFF VALVES FOR BOTH SETTLING TANKS. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Engineering › Lubricating Oil Service System
Issued 15 February 2002 Resolved
L/O VENT ON MAIN DECK STBD SIDE NEEDS CONTAINMENT, HAVE CLASS ADDRESS. LEGACY COMPONENT DESC: Vent Pipe
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Documentation › Safety/Response Plans/Programs
Issued 15 February 2002 Resolved
HAVE CLASS ADDRESS AN APPROVED FIRE CONTROL PLAN WITH FIRE RESISTANT BULKHEADS ON LEGEND. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Fire Fighting › Miscellaneous Items
Issued 15 February 2002 Resolved
PLUG STUFFING TUBES AND PACK AND COVER ALL HOLES IN AFT STEERING FWD BULKHEAD. LEGACY COMPONENT DESC: A Class Division Penetrations
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Fire Fighting › Combustible Materials
Issued 15 February 2002 Resolved
PROVIDE APROPIATE STOWAGE FOR GAS CANS LOCATED IN A/C COMPRESSOR ROOM.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Documentation › Manifests/Lists
Issued 15 February 2002 Resolved
DANGEROUS CARGO MANIFEST FILLED OUT INCOMPLETE. LEGACY COMPONENT DESC: Dangerous Goods Manifest/Stowage Plan
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Fire Fighting › Miscellaneous Items
Issued 15 February 2002 Resolved
LABEL ALL FIRE HOSE STOWAGE BOXES TO THE SATISFACTION OF CLASS.
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Navigation › Piloting/Steering
Issued 15 February 2002 Resolved
US CHART #11416 NOT CORRECTED UP TO DATE WITH NTM CORRECTIONS. LEGACY COMPONENT DESC: Marine Charts
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Engineering › Sea-water System (primary cooling)
Issued 15 February 2002 Resolved
CLASS TO ADDRESS GENERATOR RAW WATER PUMP CROSS CONNECTED TO FIRE MAIN AND PRVIDE MSD STORAGE TANK PLACARD. CLASS APPROVED LEGACY COMPONENT DESC: Piping
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Electrical › Lighting (service)
Issued 15 February 2002 Resolved
WIRING TO PORT SIDE SPOTLIGHT NEEDS STOWING , UNSAT EXPOSED TO WEATHER. TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Electrical › Lighting (service)
Issued 15 February 2002 Resolved
REPLACE LIGHT BULB AT TOP OF LADDER TO PAINT LOCKER. TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 15 February 2002 Resolved
LABEL VALVE FOR PAINT LOCKER SPRINKLER SYSTEM LOCATED ON THE MAIN DECK STBD SIDE FWD. LEGACY COMPONENT DESC: Valves
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Electrical › Electrical Distribution System (emergency)
Issued 15 February 2002 Resolved
EXCESSIVE CORROSION ON BATTERIES AND GENERAL MAINTENANCE OF BATTERY ROOM. TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Wiring
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Construction/Loadline › Structures
Issued 15 February 2002 Resolved
CLASS TO ADDRESS WASTED VENT COVER ON PORT SIDE STACK EXHAUST VENT. LEGACY COMPONENT DESC: Machinery Space Opening
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Electrical › Electrical Distribution System (service)
Issued 15 February 2002 Resolved
SECURE LOOSE WIRES IN AFT STEERING. TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Wiring
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Navigation › Piloting/Steering
Issued 15 February 2002 Resolved
STEERING HAD 5 DEGREE DISCREPPANCY BETWWEN BRIDGE RUDDER ANGLE INDICATOR AND RUDDER STOCK. LEGACY COMPONENT DESC: Compass Deviation Table
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Navigation › Piloting/Steering
Issued 15 February 2002 Resolved
MARK RUDDER ANGLE INDICATOR IN AFT STEERING WITH PORT AND STBD DESIGNATION.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Electrical › Lighting (service)
Issued 15 February 2002 Resolved
LIGHT FIXTURE STBD SIDE AMIDSHIP MAINDECK LOOSE WIRING, UNSAT. REPAIR TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Electrical › Lighting (service)
Issued 15 February 2002 Resolved
LIGHT FIXTURE IN EMERGENCY ESCAPE FROM CARGO HOLD PORT SIDE AFT, UNSAT, REPLACE OR REPAIR AS NECCESSARY. TO SATISFACTION OF CLASS. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Personnel › Certificates/Documents/Licenses
Issued 15 February 2002 Resolved
PROVIDE FLAG STATE APPROVAL/ ENDORSEMENT OF ALL NATIONAL OFFICERS LICENSES OR PROVE APPLICATION HAS BEEN MADE FOR FLAG (CAYMAN) LICENSES BY ALL OFFICERS. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Documentation › Certificates/Documents
Issued 15 February 2002 Resolved
VESSEL STABILITY BOOK DOES NOT INCLUDE CALCULATIONS FOR INSTALLED DECK CARGO CRANE. CLASS/FLAG TO ADDRESS AND PROVIDE APPROVED STABILITY BOOK. LEGACY COMPONENT DESC: Intact Stability Booklet
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Documentation › Certificates/Documents
Issued 15 February 2002 Resolved
SOLAS TRAINING MANUAL, SOPEP, CARGO SECURING MANUAL, ALL REQUIRE FLAG STATE APPROVAL. CLASS ADDRESS AND PROVIDE REPORT. LEGACY COMPONENT DESC: Intact Stability Booklet
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 15 February 2002 Resolved
INSTALL HANDRAIL OVER MDE, AND REPLACE LIGHT BULBS OVER MDE. CLASS APPROVED PROPER OPERATION. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 6 March 2002
Engineering
Issued 7 August 2001 Resolved
PROVIDE CLASS REPORT REGARDING FUEL OIL CONTAINMENT OF FOWARD FUEL PIPE.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Construction/Loadline
Issued 7 August 2001 Resolved
REPLACE GASKET ON FORWARD PORTSIDE WATERTIGHT DOOR.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Lifesaving
Issued 7 August 2001 Resolved
REPLACE/REPAIR RETRO REFLECTIVE TAPE ON ALL LIFERINGS.
Condition: Unknown
Due 6 September 2001
Resolved 6 September 2001
Engineering
Issued 7 August 2001 Resolved
INSTALL PLUGS IN ALL OIL CONTAINMENT CONTAINERS.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 7 August 2001 Resolved
PROVIDE SERVICE REPORT ON STARBOARD LIFERAFT.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Documentation
Issued 24 January 2001 Resolved
Proof a valid license for second officer.
Condition: Unknown
Due 24 January 2001
Resolved 17 February 2001
Documentation
Issued 24 January 2001 Resolved
Have class address first officer license, (does CAYMAN ISLAND flag aprove afirst officer Hounduras licese as equivalent as chief officer).
Condition: Unknown
Due 24 January 2001
Resolved 17 February 2001
Documentation
Issued 24 January 2001 Resolved
Have class provide resolution of all outstanding deficiencies.
Condition: Unknown
Due 24 January 2001
Resolved 17 February 2001
Electrical
Issued 24 January 2001 Resolved
Fix rupture on sea water cooling line for generator #3 and repair oil leak on all three generators.
Condition: Unknown
Due 24 January 2001
Resolved 17 February 2001
Documentation
Issued 10 August 2000 Resolved
Prior to departure provide seaman books for the crew
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Documentation
Issued 10 August 2000 Resolved
Prior to departure provide a valid certificate of class
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Documentation
Issued 10 August 2000 Resolved
Prior to departure provide a valid license for the chief engineer
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Construction/Loadline
Issued 7 October 1999 Resolved
PRIOR TO 07NOV99 REPAINT STARBOARD LOADLINE MARKING TO ACCURATELY REFLECT CURRENT CLASS SOCIETY.
Condition: Unknown
Due 7 November 1999
Resolved 8 October 1999
Documentation
Issued 7 October 1999 Resolved
PRIOR TO DEPARTURE PROVIDE VALID SAFETY EQUIPMENT CERTIFICATE
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Documentation
Issued 7 October 1999 Resolved
PRIOR TO DEPARTURE PROVIDE A VALID MASTER'S LICENSE FOR VESSEL OF 1919GT.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Navigation
Issued 7 October 1999 Resolved
PRIOR TO NEXT U.S. PORT CONDUCT EMERGENCY STEERING DRILLS.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Unknown
Issued 7 October 1999 Resolved
PRIOR TO NEXT U.S. PORT PLACE LOCAL OR NRC PHONE NUMBERS IN SOPEP.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Construction/Loadline
Issued 7 October 1999 Resolved
PRIOR TO DEPARTURE REPAIR HOLE IN MAIN DECK IN WAY OF ANCHOR WINDLASS.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Navigation
Issued 7 October 1999 Resolved
PRIOR TO NEXT U.S. PORT UPDATE LOCAL CHARTS TO REFLECT CHANGES PER LATEST NTM.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Accommodation/Occupational Safety
Issued 7 October 1999 Resolved
PRIOR TO NEXT U.S. PORT REPLACE MISSING RAILING IN WAY OF BOAT DAVIT.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Lifesaving
Issued 7 October 1999 Resolved
PRIOR TO DEPARTURE DEMONSTRATE OPERATION OF RESCUE BOAT DAVIT AND MOTOR TO SATISFACTION OF CLASS.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Navigation
Issued 7 October 1999 Resolved
PRIOR TO NEXT U.S. PORT PROVIDE TRAINING TO CREW ON USE OF EMERGENCY STEERING.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Lifesaving
Issued 15 October 1998 Resolved
Commence logging maintenance/inspections of lifesaving equipment.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Documentation
Issued 15 October 1998 Resolved
Provide valid license for Chief Mate with flag state recognition._x001C_
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
Provide valid radio operator license for Chief Mate with flag state recognition.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
Provide valid license for Chief Engineer with flag state recognition.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
Provide valid 2nd. Engineer officer license with flag state recognition.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Lifesaving
Issued 15 October 1998 Resolved
Provide signalling mirror and compass for rescue boat.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Fire Fighting
Issued 15 October 1998 Resolved
Conduct satisfactory fire drill in presence of Coast Guard inspector.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
Provide Coast Guard with class report addressing all deficiency requirements prior to departure.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Lifesaving
Issued 15 October 1998 Resolved
Commence logging operation of rescue boat engine._x001C_
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Navigation
Issued 15 October 1998 Resolved
Swing ship and provide current deviation table.
Condition: Unknown
Due 1 March 1999
Resolved 1 March 1999
Engineering
Issued 15 October 1998 Resolved
Provide oil transfer procedures in language of crew.
Condition: Unknown
Due 15 October 1998
Resolved 20 October 1998
Navigation
Issued 15 October 1998 Resolved
Provide charts and notice to mariners from same agency.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Navigation
Issued 15 October 1998 Resolved
Provide current tables (1998 edition).
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Navigation
Issued 15 October 1998 Resolved
Have class society address inoperable port radar & make repairs.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Navigation
Issued 15 October 1998 Resolved
Provide equipment for plotting relative motion.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Navigation
Issued 15 October 1998 Resolved
Provide emergency steering instructions on bridge & in aft steering flat inlanguage of crew.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Construction/Loadline
Issued 15 October 1998 Resolved
Provide gasket for watertight door in paint locker.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Lifesaving
Issued 15 October 1998 Resolved
Post instructions for launching of rescue boat in language of crew.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Lifesaving
Issued 15 October 1998 Resolved
Provide current servicing stickers on liferafts.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Lifesaving
Issued 15 October 1998 Resolved
Provide two 2.5 kg lifebuoys on bridge wings capable of quick release.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Fire Fighting
Issued 15 October 1998 Resolved
Class society must approve fire control plan in language of crew with ship accurate information.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Engineering
Issued 15 October 1998 Resolved
Operating instructions for OWS must be in language of crew.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
Provide Solas Training Manual in language of crew with ship specific information.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Documentation
Issued 15 October 1998 Resolved
Provide manuals for maintenance and operation of all lifesaving and firefighting equipment.
Condition: Unknown
Due 17 October 1998
Resolved 20 October 1998
Lifesaving
Issued 26 February 1996 Resolved
PROVIDE EMERGENCY LIGHTING IN WAY OF LIFERAFT EMBARKATION AREAS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 26 February 1996 Resolved
PROVIDE INSTRUCTION PLACARDS FOR STEERING AND LIFESAVING APPLIANCES.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Lifesaving
Issued 26 February 1996 Resolved
REPLACE THE SCBA TANK ON THE FIREMAN'S OUTFIT.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Navigation
Issued 26 February 1996 Resolved
PAINT THE NAVIGATION SIDELIGHTS SCREENS MATTE BLACK.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Accommodation/Occupational Safety
Issued 26 February 1996 Resolved
REINSTALL THE LADDER STEP AND RUNG IN THE LOWER ENGINE ROOM (2ND MEANS OF ESCAPE).
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 26 February 1996 Resolved
PROVIDE TWO ADDITIONAL SOLAS ROCKET PARACHUTE FLARES.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Engineering
Issued 26 February 1996 Resolved
REPLACED CRACKED COVERS FOR THE MDE CAMSHAFT INSPECTION DOORS.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Navigation
Issued 26 February 1996 Resolved
PROVIDE COPIES OF THE US COAST PILOT, TIDAL CURRENT TABLES, AND COLREGS.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Documentation
Issued 26 February 1996 Resolved
PROVIDE AN UPDATED SOLAS TRAINING MANUAL.
Condition: Unknown
Due 8 May 1996
Resolved 8 May 1996
Fire Fighting
Issued 26 February 1996 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE SHIPS FIRE MAIN PIPING.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Engineering
Issued 26 February 1996 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Documentation
Issued 26 February 1996 Resolved
PROPERLY INSTALL THE GERMANISCHER LLOYDS DESIGNATION LETTERS IN WAY OF THE LOADLINE MARKS ON BOTH SIDES OF THE HULL.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Fire Fighting
Issued 28 June 1995 Resolved
SERVICE ALL FIRE EXTINGUISHERS IN ENGINE ROOM AND BATTERY ROOM
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Navigation
Issued 28 June 1995 Resolved
PROVIDE CURRENT COPIES OF U.S.COAST PILOT AND TIDAL CURRENT TABLES
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Fire Fighting
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER II-2 IN THAT THE FIRE MAIN PIPE TO THE PAINT LOCKER IS BROKEN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 22 March 1994
Lifesaving
Issued 1 March 1994 Resolved
A VIO OF ILO 147 ACCIDENT PREVENTION IN THAT THE LUBE OIL PURIFIER AND SURROUNDING DECK WERE COVERED WITH OIL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Fire Fighting
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER II-2 IN THAT THE FIRE MAIN WAS NOT WORKING PROPERLY WITH NO WATER REACHING THE FORWARD AREAS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Documentation
Issued 1 March 1994 Resolved
A VIO OF ILO 147 IN THAT THE CHIEF ENGINEER DID NOT HAVE A CURRENT OFFICERSCOMPETENCY LICENSE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Documentation
Issued 1 March 1994 Resolved
A VIO OF ILO 147 IN THAT THE CHIEF MATE DID NOT HAVE A COMPETENCY CERTIFICATE ACCEPTED BY THE FLAG STATE OF THE VESSEL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Electrical
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER I REGULATION 40 IN THAT THE ELECTRICAL WIRING WERE NOT MAINTAINED AS REQUIRED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 March 1994
Resolved 22 March 1994
Lifesaving
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER IIIK REGULATION 7 IN THAT HALF OF THE LIFE BUOYS DIDNOT HAVE SELF IGNITING LIGHTS ATTACHED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Engineering
Issued 1 March 1994 Resolved
A VIO OF 33 CFR 156.170 IN THAT THE BUNKER LINE PRESSURE TEST REQUIRED WAS NOT CONDUCTED OR LOGGED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Lifesaving
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER III REG. 19 IN THAT THE INSPECTIONS REQUIRED BY PARAGRAPH 7 HAVE NOT BEEN CONDUCTED OR LOGGED.
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Lifesaving
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER III REGULATION 27 IN THAT THE IMMERSION SUITS REQUIRED BY PARAGRAPH 3.2 WERE NOT ON BOARD.
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Lifesaving
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER III REGULATION 39 IN THAT THE LIFERAFTS WERE NOT INSPECTED OR PROPERLY MARKED WITH THE INFORMATION REQUIRED BY PARAGRAPH 7.3._x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Fire Fighting
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER II-2 REGULATION 17 IN THAT THE VESSEL DID NOT HAVE ON BOARD TWO FIREMANS OUTFITS AS REQUIRED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Fire Fighting
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER II-2 IN THAT THE FIRE EXTINGUISHERS WERE NOT INSPECTED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Fire Fighting
Issued 1 March 1994 Resolved
A VIO OF SOLAS CHAPTER II-2 REGULATION 4 PARAGRAPH 7 IN THAT EVERY FIRE HOSE WAS NOT PROVIDED WITH A NOZZLE AS REQUIRED. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 March 1994
Resolved 16 March 1994
Navigation
Issued 7 April 1993 Resolved
NO U.S. COAST PILOT OR EQUIVALENT ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 7 April 1993 Resolved
CHARTS FOR PORT NOT ONBOARD.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Accommodation/Occupational Safety
Issued 6 January 1992 Resolved
The vessel's type II MSD did not have any chemicals for operation of unit. The chief engineer stated that he did not know when chemicals were last introduced to the system.
Condition: Unknown
Due 19 February 1992
Resolved 19 February 1992
Documentation
Issued 25 March 1985 Resolved
NO VALID IOPP CERTIFICATE ONBOARD
Condition: Unknown
Due 25 March 1985
Resolved 25 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.