MAURY USCG vessel records
← All vessels

CUMBERLAND QUEEN II

Built
1985
Last inspected
14 January 2026
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDN5311
247666
Flag
UNITED STATES
Maury page id
psix-247666

Documentation record

Registered dimensions (L × B × D)80.0 ft × 22.0 ft × 7.4 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT · PATTERSON, LA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portST MARYS, GA
Endorsements, as the file codes themcw_un, rec
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
34 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 83 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

14 January 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8291513
23 September 2025 Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8239705
25 November 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8039627
11 January 2024 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7847859
7 December 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7836172
8 December 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7606293
6 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7376651
1 December 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7358854
1 October 2020 COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7050215
14 January 2020 Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6889155
17 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6854288
5 January 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606577
7 March 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6367795
4 January 2018 Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6332345
13 December 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6314268
7 September 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5994474
5 January 2016 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5790170

Deficiency record · 83

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 January 2026 Resolved
Each inlet or discharge pipe that penetrates the hull within 6 inches of the depest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. A/C through hull pipe fractured and valve does not work. Make proper repairs. 46 CFR 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 23 January 2026
Resolution: Reparied to the satisfaction of USCG MIs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025 Resolved
Fire pump outlet shall be fitted with pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Installed pressure guage.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025 Resolved
Fire pump sea suction valve handle was loose/broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Replaced sea suction valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2025 Resolved
Port shaft seal housing loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: replaced bolt in shaft seal housing.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025 Resolved
Install shutoff valve on port fire hydrant.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Shut off valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 September 2025 Resolved
Generator exhaust hose clamps broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Replaced hose clamp.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2025 Resolved
Switch board ground detector shows 5 amp ground
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 15 October 2025
Resolution: No ground on switch board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2025 Resolved
Leak on port main engine exhaust in way of muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 15 October 2025
Resolution: Re-welded the exhaust and replaced wasted section.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2025 Resolved
A/C breaker #2 and #3, safety switch box covers open.
Action required: 10 - Deficiency Rectified
Due 29 September 2025
Resolved 29 September 2025
Resolution: resecured fixtures to bulkhead.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 18 December 2024 Resolved
Vessel shall at all times maintain a proper look-out. Port & stbd forward bridge windows fogged impeding master's visibility. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 21 January 2025
Resolution: Replaced both windows with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2024 Resolved
Each lifejacket must be approved in accordance with 160.002, 160.005, or 160.055. Eight Adult lifejackets retroreflective material worn. Until corrected, vessel limited to 145 persons on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 January 2025
Resolved 21 January 2025
Resolution: Retro-reflective tape was replaced on worn lifejackets.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 December 2024 Resolved
Fire drills shall be logged and include general descriptions of the drill scenario and training topics. Drills logged but didn't give a description of the drill or define training topics.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 December 2024
Resolution: Discussed logging drill scenarios/locations and training topics with vessel [name withheld] attendance, Master corrected by recording drills witnessed by CG MI's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2024 Resolved
Each child size life jacket must be stowed in a location that is marked and separated from adult life jackets. Child life jackets in upper deck stbd fed locker and in the salon were not separate from adult life jackets.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Child sized PFD's were seperated with a plywood divider installed in the cabinet.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 18 December 2024 Resolved
The master shall determine that the vessel complies with all stability requirements. Max passenger on upper deck placard is faded. Replace placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Worn placard was replaced with new placard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2024 Resolved
Bilge shall have no excessive accumulation of oil, trash, debris that might create a fire hazard. Excessive oil and rags in bilge. clean bilge and remove debris.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Bilge was clean and in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2024 Resolved
No excessive accumulation. Generator is leaking oil excessively & has significant oil accumulation. Clean generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Generator was cleaned and crew replaced leaking gaskets, no visible signs of leaks reported.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2024 Resolved
Electrical equipment in machinery spaces must be dripproof. Exposed wiring on overhead light in engine room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Broken light with exposed wiring was replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2024 Resolved
All electrical installations must be to the satisfaction of the [name withheld] exposed/disconnected wires on generator.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Generator wiring was repaired.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 December 2024 Resolved
Vessel must have visual & audible alarms for high water levels. Laz haigh water alarm not functioning properly. Repair.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2025
Resolved 21 January 2025
Resolution: Vessel rep repaired wiring, high water alarm tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2024 Resolved
Vessel must have satisfactory arrangement for draining water tight compartments. Bilge system not operating properly.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Bilge system tested and function was satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 December 2024 Resolved
Auxiliary machinery shall be suitable for the purpose intended. Generator raw water strainer was leaking.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Unit was resealed, no leaks visible.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2024 Resolved
Each fire hydrant shall have a fire hose. Port fire hose has hole. Replace fire hose.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Fire hose was replaced and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2024 Resolved
Spanner wrenches must be provided where fire hoses are required. No spanner wrenches onboard. Obtain wrenches & make readily accessible to fire hydrants.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Spanner wrenches were procured and are stowed onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 December 2023 Resolved
Observed Stbd Rear Main Deck Window broken. Renew broken window as required by 46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2024
Resolved 3 January 2024
Resolution: E-mail with statement and photos received reflecting broken window was renewed. Def resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 December 2023 Resolved
01 deck engine room vents unable to seal off air in the event of an engine room fire. Owner/operator to provide an effective means of securing air flow through the two 01 deck engine room air inlets in the event of an engine room fire as required by 46 CFR 176.830(a).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: E-mail received, with statement and photos reflecting two tarps and bungy cord procured. In event of engine room fire would be installed over both 01 deck engine room air intakes. Def satisfied.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 December 2022 Resolved
Details of the application of this requirement as well as the details of the installation shall be as set forth in the regulations of the Federal Communication Commission. FCC certificate call signs are different.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2023
Resolved 12 January 2023
Resolution: [email withheld] received picture of FCC documents. Documents are valid and call signs match.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Fire hose on fire extinguisher has a crack.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2023
Resolved 12 January 2023
Resolution: [email withheld] received picture of portable fire extinguisher with serviceable hose.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 December 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Cracks in the weld on the starboard forward rails.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2023
Resolved 12 January 2023
Resolution: [email withheld] received picture of proper weld on handrail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 December 2021 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation. Provide functioning voltmeter and ammeter for generator. 46 CFR 183.10-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2022
Resolved 8 December 2021
Resolution: Installed new gauges to meet the requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 December 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Provide proper first-aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2022
Resolved 8 December 2021
Resolution: Purchased new first aid kit that meets 160.041
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2020 Resolved
Vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Hydraulic hoses in lazarette are substantially deteriorated, replace with suitable replacements. 46 CFR 182.30-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Hydraulic hoses replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 October 2020 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Means to prevent accidental injury to persons around or operating fire pump power take off belt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Machinery guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2020 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test engineering items to the extent necessary to determine that they are in proper operating condition' and fit for the service for which they are intended. Both shaft seals where found leaking and need to be replaced. Replace seals according to engineering specifications. 46 CFR 176.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Seals replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspectio. Starboard battery bank for main propulsion engine found with substantial corrosion. Clean all connections at battery bank. 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Connections cleaned.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Expiration date fixed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 October 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. Vessels first aid kit is not Coast Guard approved and is missing various reuired items. Replace with approved kit meeting 160.041 specifications. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: First aid kit replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2020 Resolved
The number and identification of the items (life jackets) stowed, and their sizes, must be marked in clearly legible letters and number on each container for life jackets. Location of child life jackets has no identification at storage compartment. Label compartment accordingly. 46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Compartments labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 October 2020 Resolved
EAP education program: Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistances, and display and distriution of the employer's policy regarding drug and alcohol use in the workplace. No publicly displayed hotline was found onboard vessel, post required information on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: EAP corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 December 2019 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR Part 80. 01 VHF radio was not fuctioning properly. Provide 01 functional VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 8 January 2020
Resolution: VHF radio was replaced. Verified proper installation and operation of new radio.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 December 2019 Resolved
Every vessel must be fitted with an illuminated magnetic compass. Compass light was not working. Repair/ replace compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 8 January 2020
Resolution: Compass light was fixed and verified to be operational.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2019 Resolved
A vessel must carry adequate, up-to-date Coast Pilot, tide/current tables. Provide required items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 13 January 2020
Resolution: Vessel provided new copies of Coast Pilot and tide/current tables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2019 Resolved
Each life jacket must be marked with retroreflective tape. 02 life jackets were found with degraded tape. Replace retroreflective tape on 02 life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Lifejackets had retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2019 Resolved
Each container for life jackets must be marked in clearly legible letters with the number inside. 02 containers had illegible markings. Clearly mark 02 life jacket containers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Life jacket containers were clearly marked.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 January 2019 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Top deck did not have donning placard posted. Post donning placard in view of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Donning placard posted behind wheelhouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. All life buoys had lines attached. Remove one line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Lifebuoy behind wheelhouse had line removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019 Resolved
Each ring life buoy with a floating waterlight must have a lanyard between 3' and 6'. Waterlight had a lanyard greater than 6'. Shorten lanyard to meet requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Waterlight lanyard shortened to meet regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019 Resolved
Each floating waterlight must have a corrosion resistant clip to allow quick disconnection. Clip was corroded and unable to be detached. Clean/replace clip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Clip was cleaned and operable.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 January 2019 Resolved
Materials used in piping systems must be acceptable to the [name withheld] main piping had a leak at the weld seam. Repair weld seam.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Weld seam repaired.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 January 2019 Resolved
Materials used in piping systems must be acceptable to the [name withheld] handle in engine room, broken handle main deck port side, and stuck handle main deck starboard side.Repair/replace all 03 handles for fire main/bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: All 03 handles were operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2019 Resolved
A bilge pipe forward of collision bulkhead must be operable from the weather deck. Valve did not close/open. Fix/replace valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Valve was operable.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 10 January 2019 Resolved
Vessel shall be in a sanitary condition. Middle compartment below main deck had numerous cockroaches. Exterminate and remove cockroaches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: No cockroaches were seen in middle compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2019 Resolved
Cable/wire must be installed with metal supports not more than 24 inches apart. Wires near mast were unsecured. Permanently attach wires IAW regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Wires permanently attached.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 January 2019 Resolved
The Bridge-to-Bridge Act includes vessels over 20 meters in length. No Bridge-to-Bridge Certificate was available. Obtain valid Bridge-to-Bridge Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Verified Bridge-to-Bridge Certificate
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2019 Resolved
Vessels must undergo annual inspections within 3 months before or after each anniversary date. Owner informed, annual inspection scheduled.
Action required: 10 - Deficiency Rectified
Due 5 January 2019
Resolved 7 January 2019
Resolution: Inspection scheduled for 01/11/2019.
Engineering › Bilge Water Management System › Interface Detector
Issued 13 December 2017 Resolved
Repair lazarette space bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Test sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2017 Resolved
Make lazarette space ready for inpection. Unsafe condition due to 4-gas meter alarm (carbon monoxide) while entering space. Repair exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Temporary fiberglass patch installed to cover exhaust port engine exhaust leak. Only deemed satisfactory as a temporary repair until its scheduled drydock in 1 month.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 December 2017 Resolved
Repair 01 lifefloat waterlight. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Painter
Issued 13 December 2017 Resolved
Replace port forward lifefloat painter. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Serviceable
Issued 13 December 2017 Resolved
Repair rips and tears on all (03) lifefloats. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 13 December 2017 Resolved
Replace 05 lifejacket lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 17 January 2018
Resolution: No longer required due to route reduction to Lakes, Bays, and Sounds.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 December 2017 Resolved
Add/replace proper retro-reflective tape on all (03) lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Paddle
Issued 13 December 2017 Resolved
Replace 02 broken lifefloat oars. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Paddle
Issued 13 December 2017 Resolved
Add vessel name to oars.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 December 2017 Resolved
Replace portable fire extinguisher bracket on bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Bracket replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 December 2017 Resolved
Add vessel name to starboard side life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Name added.
Engineering › Fuel Oil Service System › Hose
Issued 13 December 2017 Resolved
Replace generator fuel feed flexible hose to strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Fuel hose replaced.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 13 December 2017 Resolved
Place non-conductive matting in front of switchboard and distribution panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Rubber mats were placed on the deck.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 December 2017 Resolved
Properly label circuit breaker panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Missing label added.
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 December 2017 Resolved
Provide copy of applicable U.S. Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Paper copy provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 December 2017 Resolved
Provide copy of applicable Coast Guard Light List.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Electronic copy provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 December 2017 Resolved
Provide copy of applicable Tide Tables
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Electronic copy provided.
Navigation › Piloting/Steering › Marine Charts
Issued 13 December 2017 Resolved
Provide copy of applicable updated marine charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Electronic copy provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 December 2017 Resolved
Provide copy of Inland Navigation Rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 10 January 2018
Resolution: Paper copy provided.
Construction/Loadline › Hull › Side Shell
Issued 13 December 2017 Resolved
Repair pin hole on the port side of the hull in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 30 January 2018
Resolution: Owner completed a soap and blow test. Test SAT.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2017 Resolved
Repair waterleak in generator exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: No leaks. Test SAT.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2017 Resolved
Make permanent repairs to generator exhaust overboard discharge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 10 January 2018
Resolution: Witnessed satisfactory completion during vessel's drydock.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 December 2017 Resolved
Replace expired EPIRB hydro-static release unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Fire Fighting › Fire Main › Condition
Issued 15 September 2016 Resolved
Six pin hole leaks found in fire main piping. Six other corrosion areas causing leakage found on generator raw water discharge line. Submit repair proposal for approval prior to repairing pipes. Replace pipes to satisfaction of marine inspector. 46 CFR 182.710 and 46 CFR 181.15-5(c).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 30 September 2016
Resolution: MI's inspected new piping under pressure.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 September 2016 Resolved
Provide evidence of maintenance on fire extinguishing equipment. 46 CFR 176.810 (b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 16 September 2016
Resolution: maintenance tag was on the back of each extinguisher.
Accommodation/Occupational Safety › Ventilation › General
Issued 15 September 2016 Resolved
Make lazarrette space is avaliable for inspection. Ensure no leakage from exhaust system. 46 CFR 176.802 (a)(7)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 17 October 2016
Resolution: Corroded piping cropped. New flexible hose installed
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 15 September 2016 Resolved
Repair or replace anchor line to the satisfaction of marine inspector. 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 30 September 2016
Resolution: New anchor line installed.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 September 2016 Resolved
Provide Deviation Table for inspection. 46 CFR 185.304 (a)(8)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 30 September 2016
Resolution: Deviation table on board.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 September 2016 Resolved
Ensure DSC is operational on VHF Radio. 47 CFR 80.905(a)(1)46 CFR 184.504
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 17 October 2016
Resolution: VHF-DSC operational.

Ownership record