CUMBERLAND QUEEN II

CUMBERLAND QUEEN II is a 1985 passenger vessel (inspected). The Coast Guard has recorded 72 inspections since 1985, most recently in January 2026, along with 165 deficiencies and 5 operational controls.

Records from 1985 to 2026. Most recent: inspection, 14 January 2026.

Built
1985
Last inspected
14 January 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN5311
247666
Flag
UNITED STATES
367520320
Maury page id
psix-247666

Inspections, by type

…with no type recorded3
Years with a record 39 calendar years (1985–2026)
The 72 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)80.0 ft × 22.0 ft × 7.4 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT · PATTERSON, LA, UNITED STATES · built 1985
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST MARYS, GA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
34 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN5311MMSI 367520320 · active · compulsorily equipped · granted 14 December 2022, expires 14 December 2032
WDG2888MMSI 367520320 · expired · voluntarily equipped · granted 6 March 2012, cancelled 7 May 2022
WSP7387MMSI not assigned · expired · compulsorily equipped · granted 29 November 1994, cancelled 9 November 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 72

14 January 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8291513
23 September 2025 Administrative Inspection · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8239705
25 November 2024 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8039627
11 January 2024 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7847859
7 December 2023 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7836172
8 December 2022 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7606293
6 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7376651
1 December 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7358854
1 October 2020 COI Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7050215
14 January 2020 Examination of Repairs · Hull Examination · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6889155
17 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6854288
5 January 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6606577
7 March 2018 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6367795
4 January 2018 Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6332345
13 December 2017 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6314268
7 September 2016 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5994474
5 January 2016 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5790170
5 October 2015 Deficiency Check · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5733383
13 February 2012 Deficiency Check · Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4243631
22 August 2011 Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4132114
18 October 2010 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3872301
5 October 2010 DAPI Audit · COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3863872
5 November 2008 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3356933
20 October 2008 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3348321
28 November 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3110150
22 October 2007 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3086759
16 October 2006 Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2807186
3 October 2005 COI Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2504786
5 October 2004 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2213068
19 November 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1954044
29 October 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1939465
20 October 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1936628
18 December 2002 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1721482
21 October 2002 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1693612
22 October 2001 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1447152
23 October 2000 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1408613
18 October 1999 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1406586
18 November 1998 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1420020
26 October 1998 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1400866
27 January 1998 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1121233
2 December 1997 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 775241
27 October 1997 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 779620
14 January 1997 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1099375
12 December 1996 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1093232
5 January 1996 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1189559
6 January 1995 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 860161
7 December 1994 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 831655
15 August 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 866889
18 July 1994 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1179926
8 April 1994 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1166564
7 January 1994 COI Inspection · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1160921
25 March 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 835629
11 March 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1148870
12 January 1993 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1145044
7 January 1993 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 830121
29 January 1992 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1254179
7 January 1992 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1265459
3 December 1991 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 944105
6 February 1991 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1304357
7 January 1991 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1211625
4 December 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1218292
23 February 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1211648
9 January 1990 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1213502
28 February 1989 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1352683
10 January 1989 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1194940
15 January 1988 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1014743
21 January 1987 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1316993
21 January 1987 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1321575
15 January 1987 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1314009
21 January 1986 COI Inspection · Credit Drydock
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 994276
5 February 1985 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 979766
31 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289226

Deficiency record · 165

03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 14 January 2026 Resolved
Each inlet or discharge pipe that penetrates the hull within 6 inches of the depest load waterline must have means to prevent water from entering the vessel if the pipe fractures or otherwise fails. A/C through hull pipe fractured and valve does not work. Make proper repairs. 46 CFR 179.350
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 February 2026
Resolved 23 January 2026
Resolution: Reparied to the satisfaction of USCG MIs.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025 Resolved
Fire pump outlet shall be fitted with pressure gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Installed pressure guage.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025 Resolved
Fire pump sea suction valve handle was loose/broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Replaced sea suction valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2025 Resolved
Port shaft seal housing loose.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: replaced bolt in shaft seal housing.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 23 September 2025 Resolved
Install shutoff valve on port fire hydrant.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Shut off valve installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 September 2025 Resolved
Generator exhaust hose clamps broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 15 October 2025
Resolution: Replaced hose clamp.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2025 Resolved
Switch board ground detector shows 5 amp ground
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 15 October 2025
Resolution: No ground on switch board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 September 2025 Resolved
Leak on port main engine exhaust in way of muffler.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 October 2025
Resolved 15 October 2025
Resolution: Re-welded the exhaust and replaced wasted section.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 September 2025 Resolved
A/C breaker #2 and #3, safety switch box covers open.
Action required: 10 - Deficiency Rectified
Due 29 September 2025
Resolved 29 September 2025
Resolution: resecured fixtures to bulkhead.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 18 December 2024 Resolved
Vessel shall at all times maintain a proper look-out. Port & stbd forward bridge windows fogged impeding master's visibility. Replace in kind.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2025
Resolved 21 January 2025
Resolution: Replaced both windows with new.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2024 Resolved
Each lifejacket must be approved in accordance with 160.002, 160.005, or 160.055. Eight Adult lifejackets retroreflective material worn. Until corrected, vessel limited to 145 persons on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 January 2025
Resolved 21 January 2025
Resolution: Retro-reflective tape was replaced on worn lifejackets.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 December 2024 Resolved
Fire drills shall be logged and include general descriptions of the drill scenario and training topics. Drills logged but didn't give a description of the drill or define training topics.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 18 December 2024
Resolution: Discussed logging drill scenarios/locations and training topics with vessel [name withheld] attendance, Master corrected by recording drills witnessed by CG MI's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 December 2024 Resolved
Each child size life jacket must be stowed in a location that is marked and separated from adult life jackets. Child life jackets in upper deck stbd fed locker and in the salon were not separate from adult life jackets.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Child sized PFD's were seperated with a plywood divider installed in the cabinet.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 18 December 2024 Resolved
The master shall determine that the vessel complies with all stability requirements. Max passenger on upper deck placard is faded. Replace placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Worn placard was replaced with new placard.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2024 Resolved
Bilge shall have no excessive accumulation of oil, trash, debris that might create a fire hazard. Excessive oil and rags in bilge. clean bilge and remove debris.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Bilge was clean and in satisfactory condition.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2024 Resolved
No excessive accumulation. Generator is leaking oil excessively & has significant oil accumulation. Clean generator.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Generator was cleaned and crew replaced leaking gaskets, no visible signs of leaks reported.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2024 Resolved
Electrical equipment in machinery spaces must be dripproof. Exposed wiring on overhead light in engine room.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Broken light with exposed wiring was replaced with new.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2024 Resolved
All electrical installations must be to the satisfaction of the [name withheld] exposed/disconnected wires on generator.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Generator wiring was repaired.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 18 December 2024 Resolved
Vessel must have visual & audible alarms for high water levels. Laz haigh water alarm not functioning properly. Repair.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2025
Resolved 21 January 2025
Resolution: Vessel rep repaired wiring, high water alarm tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2024 Resolved
Vessel must have satisfactory arrangement for draining water tight compartments. Bilge system not operating properly.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Bilge system tested and function was satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 December 2024 Resolved
Auxiliary machinery shall be suitable for the purpose intended. Generator raw water strainer was leaking.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Unit was resealed, no leaks visible.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2024 Resolved
Each fire hydrant shall have a fire hose. Port fire hose has hole. Replace fire hose.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2025
Resolution: Fire hose was replaced and tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 December 2024 Resolved
Spanner wrenches must be provided where fire hoses are required. No spanner wrenches onboard. Obtain wrenches & make readily accessible to fire hydrants.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 January 2025
Resolved 21 January 2025
Resolution: Spanner wrenches were procured and are stowed onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 19 December 2023 Resolved
Observed Stbd Rear Main Deck Window broken. Renew broken window as required by 46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2024
Resolved 3 January 2024
Resolution: E-mail with statement and photos received reflecting broken window was renewed. Def resolved.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 19 December 2023 Resolved
01 deck engine room vents unable to seal off air in the event of an engine room fire. Owner/operator to provide an effective means of securing air flow through the two 01 deck engine room air inlets in the event of an engine room fire as required by 46 CFR 176.830(a).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2024
Resolved 3 January 2024
Resolution: E-mail received, with statement and photos reflecting two tarps and bungy cord procured. In event of engine room fire would be installed over both 01 deck engine room air intakes. Def satisfied.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 8 December 2022 Resolved
Details of the application of this requirement as well as the details of the installation shall be as set forth in the regulations of the Federal Communication Commission. FCC certificate call signs are different.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2023
Resolved 12 January 2023
Resolution: [email withheld] received picture of FCC documents. Documents are valid and call signs match.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022 Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Fire hose on fire extinguisher has a crack.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2023
Resolved 12 January 2023
Resolution: [email withheld] received picture of portable fire extinguisher with serviceable hose.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 December 2022 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Cracks in the weld on the starboard forward rails.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2023
Resolved 12 January 2023
Resolution: [email withheld] received picture of proper weld on handrail.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 December 2021 Resolved
A voltmeter and an ammeter shall be provided that can be used for measuring voltage and current of each generator that is in operation. Provide functioning voltmeter and ammeter for generator. 46 CFR 183.10-5
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2022
Resolved 8 December 2021
Resolution: Installed new gauges to meet the requirement.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 December 2021 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Provide proper first-aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 January 2022
Resolved 8 December 2021
Resolution: Purchased new first aid kit that meets 160.041
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 October 2020 Resolved
Vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Hydraulic hoses in lazarette are substantially deteriorated, replace with suitable replacements. 46 CFR 182.30-1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Hydraulic hoses replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 October 2020 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Means to prevent accidental injury to persons around or operating fire pump power take off belt.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Machinery guard installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2020 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test engineering items to the extent necessary to determine that they are in proper operating condition' and fit for the service for which they are intended. Both shaft seals where found leaking and need to be replaced. Replace seals according to engineering specifications. 46 CFR 176.25-10
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Seals replaced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 October 2020 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspectio. Starboard battery bank for main propulsion engine found with substantial corrosion. Clean all connections at battery bank. 46 CFR 183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Connections cleaned.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 October 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Expiration date fixed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 October 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. Vessels first aid kit is not Coast Guard approved and is missing various reuired items. Replace with approved kit meeting 160.041 specifications. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: First aid kit replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 October 2020 Resolved
The number and identification of the items (life jackets) stowed, and their sizes, must be marked in clearly legible letters and number on each container for life jackets. Location of child life jackets has no identification at storage compartment. Label compartment accordingly. 46 CFR 185.604(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: Compartments labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 1 October 2020 Resolved
EAP education program: Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistances, and display and distriution of the employer's policy regarding drug and alcohol use in the workplace. No publicly displayed hotline was found onboard vessel, post required information on board vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 November 2020
Resolved 16 October 2020
Resolution: EAP corrected.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 December 2019 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR Part 80. 01 VHF radio was not fuctioning properly. Provide 01 functional VHF radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 8 January 2020
Resolution: VHF radio was replaced. Verified proper installation and operation of new radio.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 17 December 2019 Resolved
Every vessel must be fitted with an illuminated magnetic compass. Compass light was not working. Repair/ replace compass light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 8 January 2020
Resolution: Compass light was fixed and verified to be operational.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 December 2019 Resolved
A vessel must carry adequate, up-to-date Coast Pilot, tide/current tables. Provide required items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 January 2020
Resolved 13 January 2020
Resolution: Vessel provided new copies of Coast Pilot and tide/current tables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2019 Resolved
Each life jacket must be marked with retroreflective tape. 02 life jackets were found with degraded tape. Replace retroreflective tape on 02 life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Lifejackets had retroreflective tape replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 January 2019 Resolved
Each container for life jackets must be marked in clearly legible letters with the number inside. 02 containers had illegible markings. Clearly mark 02 life jacket containers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Life jacket containers were clearly marked.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 January 2019 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places. Top deck did not have donning placard posted. Post donning placard in view of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Donning placard posted behind wheelhouse.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. All life buoys had lines attached. Remove one line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Lifebuoy behind wheelhouse had line removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019 Resolved
Each ring life buoy with a floating waterlight must have a lanyard between 3' and 6'. Waterlight had a lanyard greater than 6'. Shorten lanyard to meet requirement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Waterlight lanyard shortened to meet regulations.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 January 2019 Resolved
Each floating waterlight must have a corrosion resistant clip to allow quick disconnection. Clip was corroded and unable to be detached. Clean/replace clip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Clip was cleaned and operable.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 10 January 2019 Resolved
Materials used in piping systems must be acceptable to the [name withheld] main piping had a leak at the weld seam. Repair weld seam.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Weld seam repaired.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 January 2019 Resolved
Materials used in piping systems must be acceptable to the [name withheld] handle in engine room, broken handle main deck port side, and stuck handle main deck starboard side.Repair/replace all 03 handles for fire main/bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: All 03 handles were operable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 January 2019 Resolved
A bilge pipe forward of collision bulkhead must be operable from the weather deck. Valve did not close/open. Fix/replace valve.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Valve was operable.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 10 January 2019 Resolved
Vessel shall be in a sanitary condition. Middle compartment below main deck had numerous cockroaches. Exterminate and remove cockroaches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: No cockroaches were seen in middle compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 January 2019 Resolved
Cable/wire must be installed with metal supports not more than 24 inches apart. Wires near mast were unsecured. Permanently attach wires IAW regulation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Wires permanently attached.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 10 January 2019 Resolved
The Bridge-to-Bridge Act includes vessels over 20 meters in length. No Bridge-to-Bridge Certificate was available. Obtain valid Bridge-to-Bridge Certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 February 2019
Resolved 30 January 2019
Resolution: Verified Bridge-to-Bridge Certificate
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 January 2019 Resolved
Vessels must undergo annual inspections within 3 months before or after each anniversary date. Owner informed, annual inspection scheduled.
Action required: 10 - Deficiency Rectified
Due 5 January 2019
Resolved 7 January 2019
Resolution: Inspection scheduled for 01/11/2019.
Engineering › Bilge Water Management System › Interface Detector
Issued 13 December 2017 Resolved
Repair lazarette space bilge alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Test sat.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2017 Resolved
Make lazarette space ready for inpection. Unsafe condition due to 4-gas meter alarm (carbon monoxide) while entering space. Repair exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 December 2017
Resolution: Temporary fiberglass patch installed to cover exhaust port engine exhaust leak. Only deemed satisfactory as a temporary repair until its scheduled drydock in 1 month.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 December 2017 Resolved
Repair 01 lifefloat waterlight. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Painter
Issued 13 December 2017 Resolved
Replace port forward lifefloat painter. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Serviceable
Issued 13 December 2017 Resolved
Repair rips and tears on all (03) lifefloats. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 13 December 2017 Resolved
Replace 05 lifejacket lights.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 17 January 2018
Resolution: No longer required due to route reduction to Lakes, Bays, and Sounds.
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 December 2017 Resolved
Add/replace proper retro-reflective tape on all (03) lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Paddle
Issued 13 December 2017 Resolved
Replace 02 broken lifefloat oars. Vessel is limited to Rivers route.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Lifesaving › Lifefloat › Paddle
Issued 13 December 2017 Resolved
Add vessel name to oars.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 13 December 2017 Resolved
Replace portable fire extinguisher bracket on bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Bracket replaced.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 December 2017 Resolved
Add vessel name to starboard side life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Name added.
Engineering › Fuel Oil Service System › Hose
Issued 13 December 2017 Resolved
Replace generator fuel feed flexible hose to strainer.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Fuel hose replaced.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 13 December 2017 Resolved
Place non-conductive matting in front of switchboard and distribution panel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Rubber mats were placed on the deck.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 December 2017 Resolved
Properly label circuit breaker panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Missing label added.
Navigation › Piloting/Steering › US Coast Pilot
Issued 13 December 2017 Resolved
Provide copy of applicable U.S. Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Paper copy provided.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 December 2017 Resolved
Provide copy of applicable Coast Guard Light List.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Electronic copy provided.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 13 December 2017 Resolved
Provide copy of applicable Tide Tables
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Electronic copy provided.
Navigation › Piloting/Steering › Marine Charts
Issued 13 December 2017 Resolved
Provide copy of applicable updated marine charts.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: Electronic copy provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 13 December 2017 Resolved
Provide copy of Inland Navigation Rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 10 January 2018
Resolution: Paper copy provided.
Construction/Loadline › Hull › Side Shell
Issued 13 December 2017 Resolved
Repair pin hole on the port side of the hull in the engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 30 January 2018
Resolution: Owner completed a soap and blow test. Test SAT.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2017 Resolved
Repair waterleak in generator exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 24 January 2018
Resolution: No leaks. Test SAT.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 December 2017 Resolved
Make permanent repairs to generator exhaust overboard discharge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 January 2018
Resolved 10 January 2018
Resolution: Witnessed satisfactory completion during vessel's drydock.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 December 2017 Resolved
Replace expired EPIRB hydro-static release unit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 January 2018
Resolution: Reduced COI route to Lakes, Bays, and Sounds. No longer required.
Fire Fighting › Fire Main › Condition
Issued 15 September 2016 Resolved
Six pin hole leaks found in fire main piping. Six other corrosion areas causing leakage found on generator raw water discharge line. Submit repair proposal for approval prior to repairing pipes. Replace pipes to satisfaction of marine inspector. 46 CFR 182.710 and 46 CFR 181.15-5(c).
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 30 September 2016
Resolution: MI's inspected new piping under pressure.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 15 September 2016 Resolved
Provide evidence of maintenance on fire extinguishing equipment. 46 CFR 176.810 (b)(2)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 16 September 2016
Resolution: maintenance tag was on the back of each extinguisher.
Accommodation/Occupational Safety › Ventilation › General
Issued 15 September 2016 Resolved
Make lazarrette space is avaliable for inspection. Ensure no leakage from exhaust system. 46 CFR 176.802 (a)(7)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 September 2016
Resolved 17 October 2016
Resolution: Corroded piping cropped. New flexible hose installed
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 15 September 2016 Resolved
Repair or replace anchor line to the satisfaction of marine inspector. 46 CFR 184.300
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 30 September 2016
Resolution: New anchor line installed.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 September 2016 Resolved
Provide Deviation Table for inspection. 46 CFR 185.304 (a)(8)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 30 September 2016
Resolution: Deviation table on board.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 September 2016 Resolved
Ensure DSC is operational on VHF Radio. 47 CFR 80.905(a)(1)46 CFR 184.504
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 October 2016
Resolved 17 October 2016
Resolution: VHF-DSC operational.
Engineering › Bilge Water Management System › Piping
Issued 5 October 2015 Resolved
Prove proper operation of bilge pumping operation in void #1.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 6 October 2015
Resolution: Void pipingtakes suction as designed.
Fire Fighting › Fire Hoses › Condition
Issued 5 October 2015 Resolved
Replace (one of two) fire hoses that excessively leak during operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 6 October 2015
Resolution: Port side hose was replaced with new hose.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 5 October 2015 Resolved
The required dry chemical fire extinguisher at operating station is overcharged and out of the green scale on gauge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 October 2015
Resolved 6 October 2015
Resolution: New fire extinguisher was placed on board.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 5 October 2015 Resolved
Both exhaust mufflers. located in the lazarette, are leaking exhaust gases. Make permanent repairs to remove leaks or replace mufflers as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 6 October 2015
Resolution: Satsifactory temp repairs were made. O/o is buying new mufflers in near future and will inform the CG when it occurs.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 5 October 2015 Resolved
Replace expired life jacket lights, No coastwise route voyages until corrected and cleared by the USCG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 6 November 2015
Resolution: Received e-mail from POC attesting to replacement of all life-jacket lights. Observed all purchased lights and batteries on previous def check.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 October 2015 Resolved
Ensure both required portable lights for operating station and engine room are on board and in operational condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 6 October 2015
Resolution: Two working lights were placed in positions as required.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 October 2015 Resolved
Replace expired batteries on all life floats and life rings. No coastwise or LBS night operations until replaced and cleared by USCG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 23 October 2015
Resolution: Witnessed proper repairs/replacement.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 5 October 2015 Resolved
Make repairs to [name withheld] life jackets that have minor cracks to outside coating of floatation material. Life jackets are in serviceable condition at this time but need this maintenance to remain in same condition. Additionally, clean all top side (outside) life jackets that have black mold on them.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 23 October 2015
Resolution: Witnessed proper repairs/replacement.
Lifesaving › Lifefloat › Float-free Link
Issued 5 October 2015 Resolved
Place float free link in proper position in painter container. No coastwise route until corrected and cleared by the USCG.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 23 October 2015
Resolution: Witnessed proper repairs/replacement.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 5 October 2015 Resolved
Replace life float light lanyards that are degraded from effects of the sun and sea elements.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 23 October 2015
Resolution: Witnessed proper repairs/replacement.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 5 October 2015 Resolved
Correct man overboard instruction to include use of the rescue ladder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2015
Resolved 6 October 2015
Resolution: A new instruction was drafted and placed on board as required.
Fire Fighting › Fire Pumps › Arrangement
Issued 5 October 2015 Resolved
Properly secure fire/bilge pump with fasteners that have length to allow nylock nuts to properly thread the entire length of nut threads. Current bolt is not long enough to incorporate nylock part of nut and could loosen making the pump shift and become inoperable.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 October 2015
Resolved 6 November 2015
Resolution: Received e-mailed picture of properly secured fire pump.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 5 October 2015 Resolved
Vessel operated with passengers for hire without a valid Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 October 2015
Resolved 5 November 2015
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 March 2012 Resolved
Properly label PFD storage throughout vsl.
Due 13 March 2012
Resolved 13 March 2012
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 13 February 2012 Resolved
Repair hole IWO Port exhaust muffler.
Condition: Damaged By Earlier Event
Due 20 March 2012
Resolved 13 March 2012
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 13 February 2012 Resolved
Provide 13 adult size PFD's.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 13 March 2012
Lifesaving › Hand Flares › Expired
Issued 20 October 2008 Resolved
Provide 3 additional hand red flares for a total of six flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 November 2008
Lifesaving › Lifefloat › Markings
Issued 20 October 2008 Resolved
Stencil lifefloat capacity on the top forward lifefloat.
Condition: Improper/Lack of Maintenance
Due 28 October 2008
Resolved 5 November 2008
Lifesaving › Hand Flares › Expired
Issued 22 October 2007 Resolved
Replace expired distress signals - all day flares onboard are expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2007
Resolution: Day flares replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 October 2007 Resolved
Replace hydrostatic release on EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2007
Resolution: Hydrostatic release replaced.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 October 2007 Resolved
Service EPIRB antenna.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2007
Resolution: New EPIRB antenna was purchased and placed on EPIRB.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 October 2007 Resolved
Replace expired medicine in first aid kit.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 28 November 2007
Resolution: Operator replaced expired medicine.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 22 October 2007 Resolved
Ensure proper number of life jackets are onboard - vessel is short 1 lifejacket.
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 23 October 2007
Resolution: Adequate number of lifejackets now onboard.
Lifesaving › Lifebuoys › Immediately Available
Issued 22 October 2007 Resolved
Replace life ring on port side - main deck.
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 28 November 2007
Resolution: Life ring replaced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 October 2007 Resolved
Re-stencil emergency fuel shut off valves - move stencil to door.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 28 November 2007
Resolution: Location of emergency fuel shut off valves were re-stenciled.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 October 2007 Resolved
Replace hose on generator coolant line - line is cracked.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 28 November 2007
Resolution: Line was replaced.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 October 2007 Resolved
Remove power strip from overhead in engine room (over generator).
Action required: 705 - Other - as specified
Due 29 October 2007
Resolved 28 November 2007
Resolution: Power strip was removed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 22 October 2007 Resolved
Ensure instruction for donning life jackets are posted on vessel.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 22 October 2007
Resolution: Placard purchased and posted.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 22 October 2007 Resolved
Make repair to throttle arm assembly on generator.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 28 November 2007
Resolution: Repairs were made to the throttle arm assembly.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 October 2007 Resolved
Ensure all nav pubs are onboard (light list, tide tables, etc).
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 28 November 2007
Resolution: Pubs acquired.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 22 October 2007 Resolved
Provide CPR cards for at least 50% of crew.
Action required: 705 - Other - as specified
Due 22 November 2007
Resolved 28 November 2007
Resolution: Operator provided proof that 50% of crew had CPR cards.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 October 2006 Resolved
Dead ended cable in #2 Void, on aft bulkhead Starboard side. Remove cable or put in Junction Box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 7 November 2006
Resolution: Cables were removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 October 2006 Resolved
Fire Ax on bridge does not have a cover over pick end and creates an exposed hazard as installed. Provide a guard on pick end of fire ax.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 7 November 2006
Resolution: Guard is over the pick end of the axe.
Fire Fighting › Fire Pumps › Pressure
Issued 16 October 2006 Resolved
Installed fire pump unable to maintain 60 psi. with fire hose open. Repair or repalce fire pump to maintain required psi at pump outlet.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 7 November 2006
Resolution: Installed new pump.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 16 October 2006 Resolved
Emergency Radio instructions are posted but hard to read, they are very small and behind wires and radio equipment. Install instructions that are easy to read and readily visible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2006
Resolved 7 November 2006
Resolution: New instructions are posted.
Electrical › Electric Supply System (service) › Cable
Issued 3 October 2005 Resolved
Remove all dead ended electrical cabling and switches from pilothouse console.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 20 December 2005
Resolution: All dead ended electrical cabling removed.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 3 October 2005 Resolved
Repair fractured welds on the top side railing brackets (Stbd side aft).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 14 December 2005
Construction/Loadline › Hull › Weld
Issued 3 October 2005 Resolved
Repair fractured welds in the fwd peak space, port side near gunale.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 20 December 2005
Resolution: Fractured welds repaired...
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 October 2005 Resolved
Replace main fire pump packing and/or gauge to prove proper pressure as per 46 CFR 181.300 (Presently the pump pressure indicates 50 psi and has adequate stream of water).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 November 2005
Resolved 20 December 2005
Resolution: Witnessed satisfactory operation of the fire pump....
Navigation › Collision/Grounding Avoidance
Issued 20 October 2003 Resolved
LEFT PORT NAV LIGHT INOPERABLE. REPLACE PRIOR TO NIGHT TIME VOYAGE. LEGACY COMPONENT DESC: Navigation Lights
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 29 October 2003
Operations/Management › Lifesaving
Issued 20 October 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Due 31 October 2003
Resolved 24 October 2003
Operations/Management › Lifesaving
Issued 20 October 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 20 October 2003 Resolved
RESTENCIL ENGINE ROOM EMERGENCY ESCAPE IAW 185.606.
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 29 October 2003
Lifesaving › Buoyant Apparatus
Issued 20 October 2003 Resolved
MISSING THREE PADDLES FOR LIFE FLOATS. (HAVE 7, REQUIRED 10 FOR 5 LIFE FOATS). MAX TOTAL PERSONS PERMITTED IS 66 UNTIL PADDLES REPLACED. LEGACY COMPONENT DESC: OARS
Due 20 November 2003
Resolved 29 October 2003
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 October 2003 Resolved
REPLACE RETROREFLECTIVE TAPE THAT IS COMING OFF / EXCESSIVELY WORN ON VARIOUS PFDS. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 19 November 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 20 October 2003 Resolved
PROVIDE FIRST AID KIT THAT IS CG APPROVED OR DEMONSTRATE THAT KIT ON BOARD IS EQUIVALENT. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 20 November 2003
Resolved 19 November 2003
Engineering › Diesel Engine (auxiliary)
Issued 20 November 2002 Resolved
CROP AND RENEW TO ORIGINAL THE STAINLESS STEEL EXHAUST COOLING WATER PIPE IN THE ENGINEROOM. LEGACY COMPONENT DESC: Piping (exhaust)
Due 15 December 2002
Resolved 18 December 2002
Resolution: NEW STAINLESS PIPE INSTALLED.
Electrical › Electrical Distribution System (service)
Issued 21 October 2002 Resolved
WORKLIST ITEM: INSTALL A "WET LOCATION" CONNECTION BOX IN THE LAZZARRETTE. LEGACY COMPONENT DESC: Junction Box
Condition: Placed in Improper Service
Due 30 November 2002
Resolved 20 November 2002
Lifesaving › Lifebuoys
Issued 21 October 2002 Resolved
WORKLIST ITEM: PROVIDE A NEW RING LIFE BUOY FOR THE PILOT HOUSE.
Due 30 November 2002
Resolved 20 November 2002
Lifesaving › Buoyant Apparatus
Issued 21 October 2002 Resolved
WORKLIST ITEM: PROPERLY REPAIR TWO (2) LIFEFLOATS TO REPAIR TO COVERING.
Due 30 November 2002
Resolved 20 November 2002
Navigation › Piloting/Steering
Issued 21 October 2002 Resolved
WORKLIST ITEM: EXAMINE FIXED END CONNECTION FOR STEERING HYDRAULIC RAM.
Due 30 November 2002
Resolved 20 November 2002
Resolution: CG-835 ITEM.
Construction/Loadline › Hull
Issued 21 October 2002 Resolved
COMPLETE INTERNAL STRUCTURAL EXAM AND CONDUCT DRY DOCKING. MAKE PERMANENT REPAIRS TO FRAMES 2 & 3 IN VOID #2. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2002
Resolved 20 November 2002
Engineering › Steering Gear System
Issued 21 October 2002 Resolved
INSTALL A BUSHING IN THE FIXED END OF THE TILLER ARM IN THE LAZARETTE TO PREVENT EXCESSIVE MOVEMENT OF THE RUDDER CYLINDER. LEGACY COMPONENT DESC: Linkage
Due 15 December 2002
Resolved 18 December 2002
Resolution: TILLER ARM BUILT-UP BY WELDING AND REDRILLED. TESTED SATISFACTORY.
Documentation
Issued 27 October 1997 Resolved
PROVIDE LOGS FOR TRAINING DOCUMENTATION OF FIRE, ABANDON SHIP AND MAN OVERBOARD DRILLS IAW 46 CFR 185.420/514/520/524.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Accommodation/Occupational Safety
Issued 27 October 1997 Resolved
MARK UPPERMOST PASSENGER DECK TO REFLECT MAXIMUM PASSENGER CAPACITY OF 40 PERSONS, AS STATED IN STABILITY LETTER AND COI.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Construction/Loadline
Issued 27 October 1997 Resolved
REPAIR MANUAL CLUTCH ON ENGINE DRIVEN BILGE PUMP.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Lifesaving
Issued 27 October 1997 Resolved
RENEW WATERTIGHT CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Engineering
Issued 27 October 1997 Resolved
RENEW FLAME SCREEN FOR BOTH FUEL TANK VENTS W/ NON-CORROSIVE 30 X 30 MESH MATERIAL.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Documentation
Issued 27 October 1997 Resolved
TEST AND LOG EPIRB MAINTENANCE IAW 46 CFR 185.728.
Condition: Unknown
Due 27 October 1997
Resolved 27 October 1997
Fire Fighting
Issued 14 January 1997 Resolved
RENEW B-I FIRE EXTINGUISHER. THIS REQUIREMENT IS TO BE MET PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 21 January 1997
Resolved 18 January 1997
Navigation
Issued 14 January 1997 Resolved
PROVIDE CHART FOR ATLANTIC OCEAN UP TO 100 MILES OFFSHARE OF MIAMI, FL. ALL CHARTSSS TO BE LESS THAN 3 YRS OLD.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 14 January 1997 Resolved
REPAIR DECK FRACTURE ON MAIN DECK, UNDER FWD LADDER.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Fire Fighting
Issued 14 January 1997 Resolved
RENEW DISCHARGE PRESSURE GAUGE FOR ELECTRIC FIRE PUMP.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Construction/Loadline
Issued 14 January 1997 Resolved
RENEW CHECK BALLS OF VENTS FOR THE FOREPEAK, #1 VOID AND STEERING COMPARTMENTS.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Lifesaving
Issued 14 January 1997 Resolved
RENEW SEA PAINTER FOR FWD, UPPER LIFE FLOAT. PASSENGER CARRIAGE IS REDUCED BY 22 PERSONS UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Engineering
Issued 14 January 1997 Resolved
RENEW FLAME SCREENS ON BOTH FUEL TANK VENTS WITH 30 X 30 MESH, NON-SPARKINGMATERIAL._x001C_
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Documentation
Issued 14 January 1997 Resolved
PROVIDE WATCH STATION BILL, PFD PLACARDS, AND LOGS FOR MANOVERBOARD/ABANDONSHIP/FIRE FIGHTING EVOLUTIONS, IAW PART 185 OF SUBCHAP "T" DTD 11MAR96.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Lifesaving
Issued 5 January 1996 Resolved
RENEW OR REPAIR LIFEFLOAT WATERLIGHT.
Condition: Unknown
Due 19 January 1996
Resolved 17 January 1996
Fire Fighting
Issued 5 January 1996 Resolved
PROVIDE BRONZE NOZZLE OR EQUIVALENT FOR 1 1/2" FIRE HOSE.
Condition: Unknown
Due 19 January 1996
Resolved 17 January 1996
Lifesaving
Issued 7 January 1994 Resolved
PROVIDE A SUITABLE RESCUE BOAT OR RESCUE PLATFORM. 180.10-35
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Navigation
Issued 7 January 1994 Resolved
PROVIDE PUB'S, AND CHART'S FOR VESSEL'S OPERATING AREA. (BRUNSWICK, GA TO MIAMI, FL).
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Deck/Cargo
Issued 7 January 1994 Resolved
EFFECT PERMANENT REPAIRS TO THE HYDRAULIC ANCHOR WINDLASS PIPING IN WAY OF THE COLLISTION COMPARTMENT, (PIPING LEAKS) AND SECOND COMPARTMENT AFT, PIPING LEAKS ADJACENT TO HYDRAULIC PUMP/MOTOR.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Construction/Loadline
Issued 7 January 1994 Resolved
TEST BILGE PIPING SYSTEM THROUGH OUT VESSEL. REMOVE HYDRAULIC OIL, LUBE OILFROM ALL COMPARTMENT BILGES._x001C_ AFTER REMOVAL OF HYDRAULIC OIL FROM STEERING COMPARTMENT BILGES, CLEAN AND REPAIR STEERING RAM (PISTON).
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Documentation
Issued 7 January 1994 Resolved
PROVIDE DRUG TESTING DOCUMENTATION AS PER CFR 16.230(e).
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Documentation
Issued 7 January 1994 Resolved
PROVIDE STABILITY LETTER DOCUMENTAION FOR EXPOSED WATERS OR OCEAN SERVICE.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 11 March 1993 Resolved
PROVIDE ONE RESCUE LADDER.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Fire Fighting
Issued 7 January 1992 Resolved
REMOVE TEMPORARY PIPE PATCH AND MAKE PERMANENT REPAIRS TO PINHOLE LEAK ON FIREMAIN PIPING ADJACENT TO FIRE PUMP.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Engineering
Issued 7 January 1992 Resolved
CLEAN OR REPLACE THE TWO FUEL TANK VENT PIPE FLAME SCREENS.
Condition: Unknown
Due 7 January 1992
Resolved 7 January 1992
Lifesaving
Issued 7 January 1991 Resolved
THE VESSEL'S OPERATION IS RESTRICTED TO DAYLIGHT HOURS ONLY UNTIL AN APPROVED WATER LIGHT IS INSTALLED ON THE RING BUOY AS REQUIRED BY 46 CFR 180.30-5.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Electrical
Issued 7 January 1991 Resolved
INSTALL A "BLANK" COVER OVER THE OPEN SWITCH POSITION IN THE ELECTRICAL PANEL CENTERLINE ON AFT ENGINEROOM BULKHEAD.
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Unknown
Issued 15 January 1988 Resolved
PROVE PROPER OPERATION OF THE BILGE ALARM IN THE ENGINE ROOM.
Condition: Unknown
Due 15 January 1988
Resolved 15 January 1988
Fire Fighting
Issued 15 January 1987 Resolved
SERVICE ALL FIVE PORTABLE FIRE EXTINGUISHERS ON BOARD, LAST SERVICE DATE IS1/86.
Condition: Unknown
Due 15 January 1987
Resolved 15 January 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.