Records from 1986 to 2003. Most recent: inspection, 2 June 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
2 June 2003
Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1803193
28 May 2003
Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 1805030
6 October 2001
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 294392
18 January 2001
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 286137
1 September 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 281680
9 August 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280812
30 May 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 278317
1 March 2000
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 275379
17 November 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 435286
24 August 1999
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 431840
18 September 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 420347
10 May 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 403599
28 February 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 388305
28 November 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 385214
18 February 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 6981
13 February 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 375245
28 July 1994
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 869550
5 May 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 858057
3 May 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 463780
18 December 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 363169
27 November 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 447749
15 January 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 355585
2 September 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 533227
18 February 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 458124
16 July 1991
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 344772
7 May 1990
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 336941
9 May 1989
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 330275
13 April 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 322516
23 February 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314464
2 November 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 476711
22 October 1986
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 507616
24 January 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 306516
Pollution Prevention/Response › Prevention Equipment
Issued 2 June 2003
No resolution recorded
. Prove proper operation of Incinerator, where current oil record book entries show Incinerator is burning more than max amount listed on IOPP supplement and engineers could not get Incinerator to burn sludge. Also fix Incinerator stack temp gage. Where current gage does not function.MARPOL 73/78 LEGACY COMPONENT DESC: Incinerator
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Remote Fuel Shutoff
Issued 2 June 2003
Resolved
Prove proper operation of fuel oil shutdown system, where current pressure vessel (air Reliever) is missing safety valve. SOLAS chapter I reg 11. LEGACY COMPONENT DESC: Fuel Oil Shut-Down
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2003
Lifesaving › Lifejacket/PFD (General)
Issued 2 June 2003
Resolved
Provide approved life jacket light for all life jackets on vessel. Current lights are all expired in engine room and forward (Forecastle). LEGACY COMPONENT DESC: Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2003
Fire Fighting › Fire Hoses › Location
Issued 2 June 2003
No resolution recorded
Provide fire hose rack and hose at 2nd deck stbd-side engine room by sewage tank. Current fire plan shoes a hose at this location.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Collision/Grounding Avoidance
Issued 2 June 2003
Resolved
Repair ARPA so equipment will acquire targets at the 3 to 4 mile range. 33 CFR 164.38. LEGACY COMPONENT DESC: Automatic Radar Plotting Aid (ARPA)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2003
Navigation › Piloting/Steering
Issued 2 June 2003
Resolved
Prove proper operation of the steering gear from the bridge station. Currently, steering gear is stuck in emergency station at 5 degrees STBD. SOLAS chapter I REG 11. LEGACY COMPONENT DESC: Steering
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2003
Personnel › Training
Issued 2 June 2003
Resolved
Perform satisfactory fire drill in accommodation spaces. Crew failed drill. First fireman on scene had SCBA bottle on up side down, and was not dressed out properly (pants falling down). The second fireman showed up with oxygen bottle leaking from bottle connection. Crew was standing around. LEGACY COMPONENT DESC: Fire Fighting Basic
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 June 2003
Lifesaving
Issued 6 October 2001
Resolved
Liferafts removed for servicing locally. Captain to fax servicing report and verification all liferafts onboard vessel prior to departure. Solas 74 AIII/19.8
Condition: Unknown
Due 6 November 2001
Resolved 2 June 2003
Construction/Loadline
Issued 18 January 2001
Resolved
A HOLE IN #5 CARGO TANK HOPPER STBD SIDE WAS CAUSED WHEN THE STEVE DORE CRANE OPERATOR SWUNG THE BUCKET INTO THE CARGO TANK BULKHEAD. ILLC 66 ANNEX 1/1.1.
Condition: Unknown
Due 18 January 2001
Resolved 18 January 2001
Deck/Cargo
Issued 9 August 2000
Resolved
Solas 74 amended, Chp. I Reg. II. Corrosion holes in containment on stern hydraulic winches.
Condition: Unknown
Due 5 September 2000
Resolved 5 September 2000
Lifesaving
Issued 24 August 1999
Resolved
Provide adequate food rations for lifeboats. (Rations for 30 persons each boat). SOLAS 74(A) III-41.8.12.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Accommodation/Occupational Safety
Issued 24 August 1999
Resolved
Make permanent repairs to fractured sewage pipe above MSD. MARPOL 73/78.
Condition: Unknown
Due 25 August 1999
Resolved 25 August 1999
Lifesaving
Issued 18 September 1998
Resolved
REPAIR SMALL HOLE IN STARBOARD LIFEBOAT (STARBOARD BOW) TO SATISFACTION OF CLASS. CLASS REPAIR REPORT RECEIVED._x001C_ _x001C_ SOLAS 74(A) REG III 19.2
Condition: Unknown
Due 20 September 1998
Resolved 22 September 1998
Navigation
Issued 28 February 1996
Resolved
VESSEL ARRIVED TO THE PORT OF NEW YORK WITH U.S. CHARTS #12327, 12333, AND 12337 NOT CORRECTED UP TO DATE AS REQUIRED BY 33 CFR 164.33(a)(1)(ii).
Condition: Unknown
Due 28 February 1996
Resolved 4 March 1996
Engineering
Issued 28 November 1995
Resolved
MAKE PERMANENT REPAIRS TO STEAM LEAKS IN PIPING SYSTEM FOR MAIN ENGINE_x001C_ LUBE OIL PURIFIER HEATER IN LOWER LEVEL ENGINE ROOM AFT IAW SOLAS CHAPTER_x001C_ II-1 PART C REGULATION 33 PARAGRAPH 1._x001C_ CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 28 February 1996
Resolved 28 February 1996
Accommodation/Occupational Safety
Issued 5 May 1994
Resolved
PRIOR TO NEXT U.S. PORT OF CALL MAKE REPAIRS TO PIN HOLE IN WAY OF MSD PIPING SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Fire Fighting
Issued 5 May 1994
Resolved
PRIOR TO ARRIVAL AT NEXT U.S. PORT OF CALL INSTALL GUARD IN WAY OF EMERGENCY FIRE PUMP BELT AND PULLEY.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Navigation
Issued 16 July 1991
Resolved
A VIO OF 33CFR164.30 IN THAT THE U.S. COAST PILOT (VOL 3) USED BY THE VSL WAS NOT CORRECTED THRU NTMS 17/91, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS RTE FROM SMITH PT VA TO BALTO HARBOR. NO FOREIGN EQUIVALENT O/B. _x001C_
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Navigation
Issued 16 July 1991
Resolved
A VIO OF 33CFR164.30 IN THAT THE USCG LIGHT LIST (VOL II) USED BY THE VSL WAS NOT CORRECTED THRU NTMS 17/91, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS RTE FROM SMITH PT VA TO BALTO HARBOR. NO FOREIGN EQUIVALENT O/B._x001C_
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994