ALI'I KAI is a 1984 passenger vessel (inspected). The Coast Guard has recorded 87 inspections since 1985, most recently in January 2022, along with 110 deficiencies, 1 operational control and 1 casualty investigation in 2011.

Records from 1985 to 2022. Most recent: inspection, 4 January 2022.

Built
1984
Last inspected
4 January 2022
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCE3985
248115
Flag
UNITED STATES
366923350 (licence lapsed)
Maury page id
psix-248115

Inspections, by type

…with no type recorded5
Years with a record 33 calendar years (1985–2022)
The 87 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)151.0 ft × 46.5 ft × 4.0 ft
Registered tonnagegross 96 / net 77
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderR K MARINE INC · HONOLULU, HI, UNITED STATES · built 1984
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHONOLULU, HI
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 19 June 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
77 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCE3985MMSI 366923350 · expired · voluntarily equipped · granted 9 January 2014, cancelled 11 May 2024 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 87

4 January 2022 Attraction Vessel Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7375671
30 October 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7087403
24 February 2020 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6914937
9 November 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6304524
18 November 2015 Administrative Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867802
30 October 2015 Plan Review (Other than "T")
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5867781
18 September 2015 Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5835728
1 May 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4851361
16 February 2012 DAPI Audit · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4245571
10 August 2011 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4113031
3 February 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3938166
5 January 2011 Internal Structural Exam · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3921506
9 February 2010 Deficiency Check · COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3677101
21 July 2009 Plan Review (Other than "T") · Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3541885
1 April 2009 Drydock Extension
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3444632
4 March 2009 DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3427668
11 February 2009 Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3415880
12 March 2008 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3163299
13 February 2008 Annual Inspection · MTSA Verification
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3147464
8 May 2007 Hull Examination · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2926070
21 February 2007 MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2843872
6 April 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2618512
8 March 2006 MTSA Verification · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2599646
8 March 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2622670
7 June 2005 Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2378565
15 February 2005 COI Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2293231
10 February 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1980555
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1981680
3 July 2003 Administrative Inspection
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1834215
6 May 2003 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1758424
11 February 2003 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1734098
20 March 2002 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1475673
31 August 2001 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1362456
21 May 2001 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1382261
7 February 2001 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1401408
2 February 2001 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1055620
9 March 2000 Deadweight Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 817473
8 February 2000 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1463552
19 January 2000 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 54685
13 September 1999 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1120253
10 May 1999 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1361056
4 May 1999 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393153
3 February 1999 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1393072
16 June 1998 Excursion Permit
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 792569
5 February 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1436037
19 May 1997 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374991
11 February 1997 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1388210
1 June 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 886255
15 March 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1404100
29 February 1996 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359058
16 February 1996 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1380403
6 November 1995 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1434317
15 February 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1371014
12 April 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1358360
22 February 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1455135
17 February 1994 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354570
6 December 1993 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1428289
27 August 1993 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1155672
22 March 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 836234
19 February 1993 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 839346
25 February 1992 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1471071
18 February 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254791
19 November 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 941212
25 February 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 919636
11 June 1990 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1222265
11 June 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235869
11 June 1990 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1236205
5 March 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1225453
5 March 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1227228
27 February 1990 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1236039
21 September 1989 Plan Review "T" Boat
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1207279
31 March 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1198407
3 March 1989 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1201646
10 January 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 887245
14 December 1988 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 887244
9 March 1988 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1032159
3 March 1988 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1302596
11 December 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1310245
28 May 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1339062
9 March 1987 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1319287
4 June 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 988941
25 April 1986 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1001055
18 April 1986 Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1307013
17 March 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 993787
3 December 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 990737
3 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 988116
19 March 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1289744

Deficiency record · 110

Construction/Loadline › Hull › Transverse Frame
Issued 18 September 2015 Resolved
Provide new repair proposals for FWD and AFT crossdeck wing voids.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 8 November 2017
Resolution: Vessel's COI deactivated on 8NOV2017.
Construction/Loadline › Hull › Bottom Plating
Issued 18 September 2015 Resolved
Complete all items on CG-835 issued on 02 July 2015
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2015
Resolved 8 November 2017
Resolution: Vessel's COI deactivated on 8NOV2017.
Construction/Loadline › Hull › Weld
Issued 18 September 2015 Resolved
Ensure all cut-outs, fit-ups, root pass/back gouge inspections for all repair inserts are inspected and approved by USCG inspector prior to commencing work.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 20 October 2015
Resolution: Conducted final weld inspections for repairs conducted from 9/18 thru 10/20, by visual and dye penetrant testing. All sat.
Construction/Loadline › Hull › Bottom Plating
Issued 18 September 2015 Resolved
Provide repair proposal for port E/R bottom plate repair aft of last block. Plate was damaged during dry docking.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 23 September 2015
Resolution: Received repair proposal from shipyard to crop and renew approx 8 square feet of bottom plate under the port engine room.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 September 2015 Resolved
Prove proper alignment of both port and STBD struts, shaft tubes and engines.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 8 November 2017
Resolution: Vessel's COI deactivated on 8NOV2017.
Construction/Loadline › Structures › Deck Plating
Issued 18 September 2015 Resolved
Submit plan and list of materials for leveling the main passenger deck.
Action required: 705 - Other - as specified
Due 18 October 2015
Resolved 5 October 2015
Resolution: Received proposal to apply Polyspec Lite Latex to level the deck. Materials were approved by OCMI via special consideration IAW 46CFR 114.550.
Documentation › Markings/Placards › Capacity Marking
Issued 3 February 2011 Resolved
Need maximum passenger markings on Port and Starboard accesses to upper deck. (Max 60 passengers IAW COI)
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 3 February 2011
Resolution: Added capacity markings on upper deck accesses.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 3 February 2011 Resolved
Provide adequate retroflective material for identified life jackets. Reduced passenger count until lifejackets are fit for service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2011
Resolved 3 February 2011
Resolution: Added required retroflective tape to lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 9 February 2010 Resolved
Renew retroreflective material for identified lifejackets and ring life buoys IAW 46CFR122.604(h).
Due 9 March 2010
Resolved 4 March 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 9 February 2010 Resolved
Renew life jacket storage closets located on main deck. Port side labeling to be renewed, found peeled off. Starboard side to be re-labeled to indicate 291 ADULT LIFE PRESERVERS. Stowage of life jackets are governed by 46CFR117.78.
Due 9 March 2010
Resolved 4 March 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Engineering › Bilge Water Management System › Pump
Issued 9 February 2010 Resolved
Prove operation of port side engine room bilge pump. Prior to operation of said pump, remove oily residue from bilge lines in effort to minimize marine pollution. Testing of all bilge pumps is required IAW 46CFR115.804(h).
Due 9 March 2010
Resolved 24 February 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2010 Resolved
Renew wire splicing located under bridge operating station IAW (OLD T) 46CFR183.05-50(b).
Due 9 March 2010
Resolved 24 February 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 February 2010 Resolved
Remove dead end wires for both MDE Code Indicator junction boxes IAW (OLD T) 46CFR183.05-50(b).
Due 9 March 2010
Resolved 24 February 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 February 2010 Resolved
Provide alternator guard for SSDG in port engine room IAW (OLD T) 46CFR176.25-50.
Due 9 March 2010
Resolved 24 February 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 9 February 2010 Resolved
Provide exhaust lagging for both MDE turbo charger piping IAW (OLD T) 46CFR176.25-50.
Due 9 March 2010
Resolved 24 February 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 9 February 2010 Resolved
Provide supervisors at (1) hour EAP training annually.
Due 12 March 2010
Resolved 24 February 2010
Resolution: Completed satisfactory.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 February 2010 Resolved
Provide hotline number to crewmembers IAW 46CFR16.401.
Due 12 March 2010
Resolved 12 February 2010
Resolution: Completed to the satisfaction of attending marine inspector.
Construction/Loadline › Hull › Keel
Issued 21 July 2009 Resolved
Determine source of hull leak in #4 void, starboard side and submit repair proposal to USCG Marine Inspector prior to conducting repairs. Permanent repairs must be made prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 July 2009
Resolution: Source of hull leak was determined to be three holes in the keel bottom, approximately 10 feet forward of the aft watertight bulkhead for void #4. Owner submitted temporary repair plan. CID approved plan.
Construction/Loadline › Hull › Keel
Issued 21 July 2009 Resolved
Allow USCG Marine Inspector to inspect void #4 starboard side prior to conducting repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 21 July 2009
Resolution: Coast Guard Marine Inspector inspected void after leak was stopped using "Splash Zone".
Construction/Loadline › Hull › Keel
Issued 21 July 2009 Resolved
Conduct temporary repairs to 3 small holes in #4 void (starboard hull) in accordance with approved repair proposal dated July 21, 2009. Allow Marine Inspector to inspect temporary repairs prior to getting underway with passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 July 2009
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 21 July 2009 Resolved
As per repair proposal, while underway, inspect the temporary repairs in #4 void (starboard hull) every 15 minutes and log inspections.
Action required: 705 - Other - as specified
Resolved 29 July 2009
Construction/Loadline › Hull › Keel Plate
Issued 21 July 2009 Resolved
Conduct permanent repairs and submit repair plan for USCG Marine Inspector approval prior to completing repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2009
Construction/Loadline › Hull › Keel Plate
Issued 21 July 2009 Resolved
Conduct bottom gauging of #4 void (starboard hull) and provide gauging report to USCG Marine Inspector prior to conducting repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 29 July 2009
Lifesaving › Lifebuoys › Serviceable
Issued 11 February 2009 Resolved
Repair 1 ring buoy and all identified PFD's with approved [name withheld] repair kit.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 4 March 2009
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 11 February 2009 Resolved
Renew retroreflective material on all identified PFD's.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 4 March 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 11 February 2009 Resolved
Replace twist connectors on VHF radio wiring with properly sized crimp connectors.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 11 February 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 11 February 2009 Resolved
Post radio emergency broadcast placard.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 11 February 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 11 February 2009 Resolved
Post all pages of COI on vessel visible to passengers.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 4 March 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 11 February 2009 Resolved
Renew all waterlight batteries or provide proof of expiration date.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 4 March 2009
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 11 February 2009 Resolved
Conduct satisfactory Drug and Alcohol Program Audit.
Action required: 705 - Other - as specified
Due 13 March 2009
Resolved 4 March 2009
Engineering › Diesel Engine (propulsion-reduction gear) › Crankshaft
Issued 13 February 2008 Resolved
Install guard over rotating machinery on port generator
Due 29 February 2008
Resolved 29 February 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 13 February 2008 Resolved
Hard wire all fixed electrical applianced in costume room and water cooler.
Due 29 February 2008
Resolved 13 February 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 February 2008 Resolved
reinstall conduit on the fresh water pump in office space.
Due 29 February 2008
Resolved 29 February 2008
Construction/Loadline › Structures › Manhole
Issued 13 February 2008 Resolved
crop and renew stbd #5 void walk stanchions
Due 29 February 2008
Resolved 29 February 2008
Engineering › Fuel Oil Service System › Suction Strainer
Issued 8 May 2007 Resolved
Install flame impingement bowl on fuel filter on the #2 generator.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 20 August 2007
Resolution: Sighted installed impingement bowl.
Construction/Loadline › Structures › Superstructure
Issued 8 May 2007 Resolved
Replace rotten roof overhang above and aft of the galley.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 20 August 2007
Resolution: Sighted completed repairs.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 May 2007 Resolved
Replace galley light fixture in way of the refrigerator.
Action required: 705 - Other - as specified
Due 13 June 2007
Resolved 20 August 2007
Resolution: Sighted newly installed light fixture.
Personnel › Manning/Qualifications › CPR Certified Personnel
Issued 15 February 2005 Resolved
Provide atleast 4 CPR cards.
Condition: Unknown
Due 28 February 2005
Resolved 28 February 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 15 February 2005 Resolved
Repair exhaust leak in stbd engine room.
Condition: Improper/Lack of Maintenance
Due 28 February 2005
Resolved 28 February 2005
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 15 February 2005 Resolved
In the men's head, repair cracked MSD vent prior to the completion of drydock.
Due 31 May 2005
Resolved 14 June 2005
Stability › Watertight Integrity › General
Issued 15 February 2005 Resolved
In the men's head, replace wasted scuttle prior to the completion of drydock.
Due 31 May 2005
Resolved 14 June 2005
Construction/Loadline › Structures › Deck Plating
Issued 15 February 2005 Resolved
In the fwd and aft centerline voids, replace all wasted deck plating prior to the completion of drydock.
Due 31 May 2005
Resolved 14 June 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 15 February 2005 Resolved
In the forward and aft centerline voids, ensure all pipe runs are IAW 46 CFR 182.710, prior to the completion of drydock.
Condition: Improper/Lack of Maintenance
Due 31 May 2005
Resolved 14 June 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 February 2004 Resolved
Properly wire the following equipment: cash register - second deck forward bar, second deck band stage, aft dumbwaiter hoist and aft starboard refrigerator.
Action required: 705 - Other - as specified
Due 10 March 2004
Resolved 13 February 2004
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2004 Resolved
Provide ultrasonic gauging in centerline forward void of all plating, with gauging to concentrate in way of holes in plating.
Action required: 705 - Other - as specified
Due 13 February 2004
Resolved 13 February 2004
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2004 Resolved
Upon completion of gauging, provide copy of gauging report to OCMI with repair proposal.
Action required: 705 - Other - as specified
Due 13 February 2004
Resolved 13 February 2004
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 10 February 2004 Resolved
Provide proper employee assistance program.
Action required: 705 - Other - as specified
Due 13 February 2004
Resolved 13 February 2004
Construction/Loadline › Hull
Issued 6 May 2003 Resolved
Descale underside of hull between port and starboard pontoons. LEGACY COMPONENT DESC: Hull Plating
Due 15 May 2003
Resolved 15 May 2003
Construction/Loadline › Hull
Issued 6 May 2003 Resolved
Crop and renew all knife edged stiffeners on the underside of maindeck.
Due 15 May 2003
Resolved 15 May 2003
Construction/Loadline › Hull › Hull Plating
Issued 6 May 2003 Resolved
Provide a complete gauging report for forward and after center voids bottom deck plating.
Due 15 May 2003
Resolved 15 May 2003
Construction/Loadline › Hull
Issued 6 May 2003 Resolved
Gas free the after center void and make ready for inspection.
Due 15 May 2003
Resolved 15 May 2003
Electrical › Electrical Distribution System (service)
Issued 11 February 2003 Resolved
Repair electrical connector on Starboard Fire Pump Motor IAW 46CFR120.340. LEGACY COMPONENT DESC: Wiring
Condition: Damaged By Earlier Event
Due 1 March 2003
Resolved 15 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 February 2003 Resolved
Mark upper decks for maximum number of passengers as per stability letter and COI IAW 46CFR122.602 and remove temporary marking. LEGACY COMPONENT DESC: Marking
Due 1 March 2003
Resolved 15 May 2003
Construction/Loadline › Structures
Issued 11 February 2003 Resolved
Repair wood rot on aft superstructure IAW 46CFR115.610 prior to completion of next scheduled dry dock examination. LEGACY COMPONENT DESC: Superstructure
Condition: Damaged By Earlier Event
Due 15 May 2003
Resolved 15 May 2003
Documentation
Issued 10 May 1999 Resolved
Prove vessel stability as required by 46CFR 170.175 and MSC letter dated August 03, 1999.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Fire Fighting
Issued 16 February 1996 Resolved
Repair A-60 bulkhead between holding kitchen and main dining area starboardside maindeck. Currently has a 1/2" gap at the overhead.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Navigation
Issued 16 February 1996 Resolved
Provide anchor dayshape.
Condition: Unknown
Due 13 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 16 February 1996 Resolved
Provide spanner wrench for fire station #1.
Condition: Unknown
Due 13 March 1996
Resolved 18 March 1996
Deck/Cargo
Issued 16 February 1996 Resolved
Replace electrical control unit for dumwaiter in the upperdeck galley.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 16 February 1996 Resolved
Provide proper support hanger for port generator exhaust cooling water pipe.
Condition: Unknown
Due 13 March 1996
Resolved 18 March 1996
Lifesaving
Issued 16 February 1996 Resolved
Provide divider for stowage of adult and child sized PFD's on upper deck.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 16 February 1996 Resolved
Until operation of starboard bilge pump can be proven, provide (2) 110 voltelectric submersible pumps and (1) manual bilge pump.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Electrical
Issued 16 February 1996 Resolved
Make splices for 110 volt wiring on pilothouse deck and upperdeck galley inproper junction boxes.
Condition: Unknown
Due 13 March 1996
Resolved 18 March 1996
Lifesaving
Issued 16 February 1996 Resolved
Provide rescue boat or suitable rescue platform IAW 46CFR180.10-35.
Condition: Unknown
Due 13 March 1996
Resolved 18 March 1996
Fire Fighting
Issued 16 February 1996 Resolved
Prove proper operation of starboard fire main pump. Until operable, transfer and connect firehoses from starboard fire stations to the port stations.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 16 February 1996 Resolved
At next drydock provide maximum load mark amidships.
Condition: Unknown
Due 16 February 1996
Resolved 16 February 1996
Lifesaving
Issued 16 February 1996 Resolved
Attach line for ring buoy around the body of the ring.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 17 February 1994 Resolved
RENEW STRAINER TO BILGE SUCTION IN #3 STARBOARD VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Construction/Loadline
Issued 17 February 1994 Resolved
RENEW STRAINER TO BILGE SUCTION IN #5 STARBOARD VOID._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Electrical
Issued 17 February 1994 Resolved
INSTALL PROTECTIVE COVER ON FLUORESCENT FIXTURE IN PORT ENGINE ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Lifesaving
Issued 17 February 1994 Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS IN THE PRESENCE OF A USCG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Engineering
Issued 17 February 1994 Resolved
PROPERLY INSTALL OPERATING HARDWARE AND PROVE OPERATION OF ALL PORT AND STARBOARD ENGINEROOM SEA VALVES, FROM THE WEATHERDECK. REF:46CFR171.119(d)_x001C__x001C_ _x001C_
Condition: Unknown
Due 17 February 1994
Resolved 17 February 1994
Lifesaving
Issued 17 February 1994 Resolved
RENEW MARKINGS ON UPPER DECK FOR ADULT AND CHILD PFD STOWAGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Engineering
Issued 17 February 1994 Resolved
RENEW FLAME SCREENS TO FUEL TANK VENTS WITH 30x30 MESH BRONZE, STAINLESS STEEL, OR SIMILAR METALLIC SCREEN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Electrical
Issued 17 February 1994 Resolved
PROPERLY INSTALL METALLIC SECURING HARDWARE FOR SOUND SYSTEM WIRING, UPPER DECK, AFT OF STAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1994
Resolved 22 February 1994
Accommodation/Occupational Safety
Issued 6 December 1993 Resolved
RENEW AFT UPPERDECK HANDRAIL IN ACCORDANCE WITH 46 CFR 177.35. TO THE SATISFACTION OF THE COGNIZANT MARINE INSPECTOR NO LATER THAN THE COMPLETIONOF THE 01 DECK MODIFICATIONS.
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Navigation
Issued 27 August 1993 Resolved
INSTALL NAVIGATION SIDELIGHTS IN ACCORDANCE WITH 33 CFR PART 81 APPENDIX A ANNEX I 3.(b) REGARDING HORIZONTAL POSITIONING AND SPACING OF LIGHTS.
Condition: Unknown
Due 27 August 1993
Resolved 27 August 1993
Engineering
Issued 19 February 1993 Resolved
INSTALL MISSING EXHAUST INSULATION ON BOTH MAIN ENGINES AND ON #1 & #2 GENERATORS._x001C_
Condition: Unknown
Due 19 March 1993
Resolved 18 March 1993
Documentation
Issued 19 February 1993 Resolved
PROVIDE COPY OF RANDOM DRUG AND ALCOHOL TESTING._x001C_ _x001C_
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Construction/Loadline
Issued 19 February 1993 Resolved
INSTALL STIFFENERS ON FOUR BULKHEADS WHICH SUPPORT THE FUEL TANKS._x001C_
Condition: Unknown
Due 19 February 1993
Resolved 19 February 1993
Electrical
Issued 18 February 1992 Resolved
PROVE PROPER OPERATION OF THE OVERSPEED TRIP, HIGH WATER TEMPERATURE ALARM AND LOW LUBE OIL SAFETY TRIP ON ALL 3 OF THE VESSELS' SHIPS SERVICE GENERATORS.
Condition: Unknown
Due 18 February 1992
Resolved 18 February 1992
Fire Fighting
Issued 18 February 1992 Resolved
HYDROSTATICALLY TEST ALL PORTABLE FIRE EXTINGUISHERS WITH OVER 5 YEARS SINCE THE LAST HYDROSTATIC TEST DATE. PROVIDE REPLACEMENT EXTINGUISHERS FOR THE ONES REMOVED FOR TESTING.
Condition: Unknown
Due 18 February 1992
Resolved 18 February 1992
Lifesaving
Issued 25 February 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Engineering
Issued 25 February 1991 Resolved
PROVE THE OPERATION OF THE STBD ENGINE REMOTE SHUTDOWN SWITCH ON BRIDGE.
Condition: Unknown
Due 25 February 1991
Resolved 25 February 1991
Electrical
Issued 5 March 1990 Resolved
PROPERLY INSTALL ELECTRICAL SUPPLY TO PORT ENGINEROOM VENTILATION FAN.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990 Resolved
PROPERLY INSTALL AND SUPPORT ALL "ROPE LIGHTS" OR REMOVE.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Documentation
Issued 5 March 1990 Resolved
POST REQUIRED EMERGENCY CHECK-OFF LIST AS PER 46CFR185.25.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Unknown
Issued 5 March 1990 Resolved
LABEL UPPER DECK PFD STORAGE BOXES WITH NUMBER AND TYPE OF PFD'S.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Navigation
Issued 5 March 1990 Resolved
DOUBLE NUT/PIN STEERING GEAR FITTINGS AS REQUIRED.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990 Resolved
SUPPLY CG APPROVED ELECTRICAL DIAGRAM OF VSL AS BUILT AND UPDATED WITH PRESENT SYSTEMS.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Lifesaving
Issued 5 March 1990 Resolved
VSL TO CARRY NO MORE THAN 980 ADULT/102 CHILDREN UNTIL SUFFICIENT NUMBER OFPFD'S ARE RENEWED/REPLACED AS PER COI.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Fire Fighting
Issued 3 March 1989 Resolved
PROVIDE SPANNER WRENCHES FOR FIRE HYDRANTS.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Navigation
Issued 3 March 1989 Resolved
REPLACE GOUGED FLEXIBLE LINE ON STBD STEERING RAM.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Fire Fighting
Issued 3 March 1989 Resolved
REPLACED HOLED NIPPLE ON PORT SIDE BILGE/FIRE PUMP DISCHARGE LINE.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
DRAIN WATER OUT OF PORT SIDE GENERATOR START BATTERY BOX.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Construction/Loadline
Issued 3 March 1989 Resolved
PROVIDE BILGE PIPING DIAGRAM OR LABEL MANIFOLDS TO IDENTIFY VALVES AND CORRESPONDING TANKS.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Construction/Loadline
Issued 3 March 1989 Resolved
PROVIDE VENTS FOR BALLAST TANKS #1P&S, #2P&S, AND #5P&S.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Fire Fighting
Issued 3 March 1989 Resolved
PROVIDE THREE 75 FOOT LENGTHS OF APPROVED FIRE HOSE TO REPLACE EXISTING 50 FOOT LENGTHS.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Electrical
Issued 3 March 1989 Resolved
PROVIDE NON CONDUCTIVE MAT UNDER SWITCHBOARDS.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Navigation
Issued 3 March 1989 Resolved
REPAIR/REPLACE DAMAGED COMPASS.
Condition: Unknown
Due 3 March 1989
Resolved 3 March 1989
Construction/Loadline
Issued 14 December 1988 Resolved
INSTALL VENTS IN ALL BALLAST TANKS.
Condition: Unknown
Due 14 December 1988
Resolved 14 December 1988
Fire Fighting
Issued 3 March 1988 Resolved
REPLACE TWO 1 1/4 INCH DIAMETER FIREHOSES.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Electrical
Issued 3 March 1988 Resolved
REPAIR ELECTRIC CONNECTION BOX ON STARBOARD BILGE/FIRE PUMP.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Lifesaving
Issued 3 March 1988 Resolved
PROVIDE 48 ADDITIONAL COAST GUARD APPROVED TYPE I LIFE JACKETS. UNTIL THISITEM IS COMPLETED, TOTAL PASSENGERS ALLOWED IS LIMITED TO 952.
Condition: Unknown
Due 3 March 1988
Resolved 3 March 1988
Unknown
Issued 25 April 1986 Resolved
FAIR OUT OR REPAIR BOTTOM PLATE ON STARBOARD HULL AT APPROXIMATELY FRAME 180.
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Unknown
Issued 18 April 1986 Resolved
REPAIR STARBOARD SHAFT AND PROPELLER DURING THE DRYDOCKING OF THE VESSEL SCHEDULED ON 24APR86. UNTIL REPAIRS ARE SATISFACTORILY COMPLETED, OPERA- TION OF VESSEL SHALL BE LIMITED TO MAMALA BAY ONLY.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Unknown
Issued 17 March 1986 Resolved
REPAIR OR REPLACE PORT FIRE PUMP PRESSURE GAUGE.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Accommodation/Occupational Safety
Issued 19 March 1985 Resolved
PROVE ELECTRICAL MODIFICATIONS TO THE DUMB WAITER PER CG APPROVED PLANS NO LATER THAN 19APR85.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985 Resolved
REPAIR LEAKING DRAIN LINE TO L.O. SUMP ON #1 GENERATOR NO LATER THAN 22MAR85.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985

Casualty record · 1

10 August 2011Routine · role: Involved in a Marine Casualty · activity 4113031
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.