← All vessels
LADY STUART I
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named LADY STUART I
LADY STUART I is a 1984 passenger vessel (inspected). The Coast Guard has recorded 80 inspections since 1985, most recently in May 2026, along with 263 deficiencies, 1 operational control and 1 casualty investigation in 2024.
Records from 1985 to 2026. Most recent: inspection, 18 May 2026.
- Built
- 1984
- Last inspected
- 18 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 263 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2024
Identity
675558
WDD5301
248129
Flag
UNITED STATES
367156360
Maury page id
psix-248129
Inspections, by type
…with no type recorded10
Years with a record
38 calendar years (1985–2026)
The 80 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)56.0 ft × 16.0 ft × 9.7 ft
Registered tonnagegross 60 / net 48
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDMR YACHTS · ARUNDEL, ME, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSTUART, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 10 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Simplified, Gross Ton
48 - Simplified, Net Ton
48 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ5315MMSI 367156360 · active · compulsorily equipped · granted 4 May 2017, expires 4 May 2027
WDD5301MMSI 367156360 · expired · compulsorily equipped · granted 21 December 2006, cancelled 25 February 2017
WCZ9654MMSI not assigned · expired · voluntarily equipped · granted 31 July 2000, cancelled 2 October 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 80
18 May 2026
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8381917
7 April 2025
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8100196
17 March 2025
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8095005
12 October 2024
Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam · Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8034301
10 October 2024
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8022436
10 June 2024
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7932463
7 November 2023
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7821829
15 May 2023
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7689314
16 May 2022
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7455109
10 December 2021
Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7387858
10 May 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7194537
6 October 2020
Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7107632
9 April 2020
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6952555
4 June 2019
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6702517
9 October 2018
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6557454
4 June 2018
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6433733
8 May 2017
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6141860
24 October 2016
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6028743
29 June 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5930086
27 October 2014
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5012618
2 June 2014
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4878051
22 May 2012
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4318638
2 December 2011
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4200302
21 July 2011
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4093475
29 September 2010
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3858660
6 November 2008
Internal Structural Exam · In-Service Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3357162
11 June 2008
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3233831
5 May 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3197480
19 April 2006
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2634025
7 April 2005
COI Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2331009
25 March 2005
Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2321566
15 April 2004
Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2125098
22 July 2003
Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1859336
18 May 2003
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1799006
20 April 2003
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1798930
19 April 2003
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1798885
26 March 2003
Internal Structural Exam · Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1764485
25 June 2002
Deficiency Check · Re-Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1636891
11 July 2001
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1068201
19 June 2001
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1456004
28 March 2001
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1397659
20 April 2000
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1373012
15 November 1999
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 807266
3 August 1999
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 775259
8 July 1999
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 155909
29 June 1999
Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1413562
6 April 1999
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1131413
11 June 1998
Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1130154
24 April 1997
COI Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1093098
3 April 1997
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1110106
10 May 1996
MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1082377
24 April 1996
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1078359
6 March 1996
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1081404
11 July 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1079140
25 May 1995
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1183745
16 May 1995
Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1234719
13 April 1995
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 848283
2 August 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1177050
28 April 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 860203
7 June 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1158155
6 May 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 660363
30 April 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1149954
30 April 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1153519
6 April 1993
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1146816
3 June 1992
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 949028
1 June 1992
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 961458
30 April 1992
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 959548
25 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 999145
20 March 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1242767
26 April 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 913403
28 September 1989
Damage Survey
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1310249
27 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1344104
14 April 1989
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1032189
5 April 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1339622
22 April 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1038374
1 July 1987
Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1009879
8 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023697
5 May 1987
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1326829
11 April 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1306429
12 April 1985
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1289224
Deficiency record · 263
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 April 2025
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill shall include the following information, (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. No documented evidence of drills being conducted. Second offense, previous annual inspection resulted in same violation.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel with terms of its COI giving consideration to provision for a seaworthy hull and protection against fire. STBD side outboard E/R compartment under deck wood framing is severely angel haring and breaking down creating a serious combustible hazard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 March 2025
Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck so that no open space exists that is 12” high except: (1) on a vessel on an excursion trip the following must be installed: (iii) Bars, slats, rail courses or an equivalent spaced at intervals of not more than 4”. Vessel is a charter fishing vessel but had also been operating as an excursion vessel and railings do not meet requirements above. Vessel is prohibited from carrying passengers in an excursion vessel capacity until rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 November 2024
Resolved
Except as provided by par. (e) of this section, each vessel certificated to operate on a limited coastwise route in warm water must be provided with life floats of an aggregate capacity that will accommodate 50% of the total number of persons permitted onboard. Vessel only has a 12 man lifefloat, passenger count restricted to 22 ans 2 crew for 24 persons total onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 October 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Vessel must be dry docked for a damage survey by the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 12 October 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] or alterations that affect the safety of the vessel include, but are not limited to, refastening of deck or hull planking, plating and structural members: damage repair or replacement; other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers, steering, propulsion and power supply systems; alterations affecting stability; and repair or alterations affecting life saving, fire detection or fire fighting equipment. All repairs must be to the satisfaction of the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 October 2024
Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Due to the extensive damage, the vessel must undergo a full inspection prior to passengers. New FCC safety radiotelephone inspection must also be completed with a new certificate issued, prior to inspection by the attending marine inspector.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 June 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill shall include the following information, (1) Date of the drill and training; and (2) General description of the drill scenario and training topics. Drills must be documented accordingly.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 10 June 2024
Resolved
The master of the vessel shall ensure that the EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. EPIRB test were not being logged.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 June 2024
Resolved
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space, a space with a through hull fitting, a space with a non-water tight closure. Tank high water level indicator is not working but wired into the engine room high water indicator.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2023
Resolved
A pre-engineered fixed gas fire extinguishing system must: automatically shut down all engines from within the protected space: and at the operating station, have a means to reset devices used to automatically shut down the engines as required by paragraph (a)(3) of this section. Vessel rep unable to produce 3rd party records or demonstrate proper operation of the system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 May 2023
Resolved
The shutoff valve at the tank must be manually operated from outside the compartment in which the valve is located, during a manual test of the port side fuel tank shutoff valve, valve could be turned 360 degrees and appeared non-functional. Replace with new.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 May 2023
Resolved
The discharge ends of the fuel tank vent pipes must terminate on the hull of the exterior as high above the waterline and remote from any hull openings. The discharge ends of the fuel tank vent must also be fitted with removable flame screens. Diesel tank vent hoses terminated in fuel tank compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2023
Resolved
When the flexible section (of the fuel fill) is a non-conductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of static charge, install bond wire.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 15 May 2023
Resolved
An existing vessel must comply with subdivision, damage stability, and watertight integrity regulations which were applicable to the vessel on March 10, 1996. Vessel found to have an installed drain on the aft deck by the restroom allowing water from the weather deck to drain into the fuel tank compartment bilge. Make weather deck water tight.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2023
Resolved
A vessel not required to have a power driven fire pump, must have at least 03, 9.5 liter buckets, with an attached lanyard. Missing 01 fire buckets
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 May 2023
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris or other matter that might create a fire hazard. Port M/E had excessive oil on exhaust lagging, engine and bilge below. Clean out residual oil from area.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 15 May 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard or rail.STBD M/E PTO dewatering pump and alternator do not have protections in place.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 May 2023
Resolved
A fishery endorsement entitles a vessel to employment in the fisheries as defined in 67.3, subject to federal and state laws regulating the fisheries and in any other employment in which a registry endorsement is not required. Vessel is engaged in federally permitted fisheries and does not posses a fisheries endorsement.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 15 May 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date: U.S. Coast Pilot or similar publication, Coast Guard light list. Vessel is missing both.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 December 2021
Resolved
The deck around the engine room manhole was found soft and rotted; Remove the soft deck area back to good wood and make repairs in kind to the satisfaction of attending marine inspector prior to credit dry-dock. 46 CFR 176.610.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 10 December 2021
Resolved
Permanent repairs to the upper deck port side are authorized to be completed in the water after drydock but passengers are restricted from that area until repairs have been made. Remove the soft deck area back to good wood and make repairs in kind to the satisfaction of attending marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2021
Resolved
The cutlass bearings on the Port and the STBD side were found outside of allowable tolerances and required to be replaced; replace in kind.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021
Resolved
183.200(b)
Electrical equipment on a vessel must be installed and maintained to:
Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock
Found dead end wires and heavily corroded amplifer wires behind the operation station; and a junction box light fixture hanging in the galley hold.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 May 2021
Resolved
183.350(b)
(b) Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.
Battery box covers were found off and the batteries had substantial amount of angel hair covering the terminals.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2021
Resolved
180.70(c)
c) At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:
(1) Be buoyant;
(2) Be of at least 18.3 meters (60 feet) in length;
(3) Be non-kinking;
(4) Have a diameter of at least 7.9 millimeters ( 5/16 inch);
(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
(3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy.
The lifeline was found attached to the floating waterlight.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2021
Resolved
182.455(b)
A suitable metal marine type strainer, meeting the requirements of the engine manufacturer, must be fitted in the fuel supply line in the engine compartment. Strainers must be leak free. Strainers must be the type of opening on top for cleaning screens. A drip pan fitted with flame screen must be installed under gasoline strainers. Fuel filter and strainer bowls must be highly resistant to shattering due to mechanical impact and resistant to failure due to thermal shock. Fuel filters fitted with bowls of other than steel construction must be approved by the Commandant and be protected from mechanical damage. Approval of bowls of other than steel construction will specify if a flame shield is required.
The fuel filter bowls were found with plastic drain plugs installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 May 2021
Resolved
179.360(b)
A hatch cover must:
(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss
The fwd peak lanyard was found broken.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 May 2021
Resolved
A bilge suction must be fitted with a suitable strainer having an open area not less than three times the area of the bilge pipe.
The strainer was missing from the bilge suction in the galley hold.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 10 May 2021
Resolved
The MMSI # was not programmed into the radio IAW 47CFR80.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2020
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Remove all wood rot, back to good wood, in the galley void in way of (IWO) the STBD fwd overhead longitudinal and the port aft OVHD longitudinal at the transverse blkds. Replace/ repair in kind or submit a repair proposal for alternative repairs.Repair prior to drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2020
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Deck and deck beams around vents on both sides of engine room have excessive rot/angel hair. All rotten wood should be removed to allow for a thorough examination of remaining wood.Repair prior to drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2020
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Repair wood rot IWO second deck where the rail stanchion is mounted (above steps to second deck).Repair prior to drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2020
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Repair Port side deck seating aft section is cracked and delaminated where attached to bulkhead.Repair prior to drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2020
Resolved
An internal structural examination consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Make the soft deck areas on fantail ready for a closer inspection.Repair prior to drydock credit.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 October 2020
Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Attach all loose railings on the 2nd deck.Repair prior to drydock credit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2020
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Replace Stbd engine r/w hose at discharge side of impeller.Repair prior to drydock credit.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 October 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to:
(a) Provide services necessary for safety under normal and emergency conditions;
(b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock;
(c) Minimize accidental personnel contact with energized parts; and
(d) Prevent electrical ignition of flammable vapors.
Port engine wiring connection terminal (aft section, under filter near exhaust pipe without lagging) has wire not connected and is coated with oil that has leaked on it. Clean and repair wire and oil leak. Repair prior to drydock credit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2020
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.
(c) Batteries must be accessible for maintenance and removal.
(d) Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited.
Battery cables loose and not covered. Angel hair/rotted wood covering terminal connections. Clean and tighten all connections and attach the battery box covers. Repair prior to drydock credit.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 6 October 2020
Resolved
The design of all exhaust systems must ensure minimum risk of injury to personnel. Protection must be provided in compliance with §177.970 of this chapter at such locations where persons or equipment might come in contact with an exhaust pipe.
Port engine missing exhaust lagging on outboard exhaust piping. repair/ replace as discussed.Repair prior to drydock credit.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 October 2020
Resolved
A hatch exposed to the weather must be watertight. A hatch cover must:
(1) Have securing devices; and
(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Replace gasket on FWD Peak scuttle and attach the lanyard.Repair prior to drydock credit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2020
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Replace all wasted steering and anchor hydraulic hoses and pipes. (SAEJ 1942 compliant)Repair prior to drydock credit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 6 October 2020
Resolved
On a vessel of not more than 19.8 meters (65 feet) in length carrying more than 49 passengers, and on a vessel of more than 19.8 meters (65 feet) in length, the minimum capacity of the fire pump must be 189 liters (50 gallons) per minute at a pressure of not less than 414 kPa (60 psi) at the pump outlet. Repair prior to drydock credit.
Clean out fire pump pick up at the thru hull.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2020
Resolved
A drydock examination conducted in compliance with §176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination.
Replace all cutless bearings. Repair prior to drydock credit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2020
Resolved
A drydock examination conducted in compliance with §176.600 must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, including the hull plating and planking, appendages, propellers, shafts, bearings, rudders, sea chests, sea valves, and sea strainers shall be made available for examination.
Rebed port intermediate strut and replace fasteners. Repair prior to drydock credit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 June 2018
Resolved
Demonstrate operation of fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2018
Resolved
Demonstrate operation of all installed bilge pumps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2018
Resolved
Demonstrate operation of starboard MDE.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 June 2018
Resolved
Remove oily waste from bilges prior to operating bilge pumps.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2018
Resolved
Renew grab line around ring lifebuoy and shorten light lanyard to 3-6 feet.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 June 2018
Resolved
Demonstrate operation of rudder angle indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2018
Resolved
Ensure each bilge pick-up has a screen installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2018
Resolved
Demonstrate operation of masthead light.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 4 June 2018
Resolved
Re-hang steering hydraulic hoses in lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2018
Resolved
Ensure electric bilge pump in tank compartment is installed.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 4 June 2018
Resolved
Mount fuel shut off valves ensuring they are easily operable with one hand.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 4 June 2018
Resolved
Install light covers on flourescent fixtures in engineroom or remove.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 4 June 2018
Resolved
Re-install protective covering on fire pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2018
Resolved
Clean port MDE blower intake filter apparatus.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2018
Resolved
Install metal hanging supports for all wiring especially to include shore-tie or identify a means to re-run or remove.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 June 2018
Resolved
Re-hang/support flexible hose in engineroom
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2018
Resolved
Remove yellow household (non-marine) wiring found hanging in forward compartment.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2018
Resolved
Re-hang wiringin forward compartment running port to starboard.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 4 June 2018
Resolved
Re-splice anchor thimble with good anchor line.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 June 2018
Resolved
re-seat gasket in hatch to forepeak.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2018
Resolved
Re-install wiring in junction box starboard side main deck.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 June 2018
Resolved
Demonstrate operation of all speakers or remove if found not necessary.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 4 June 2018
Resolved
Demonstrate operation of all installed deck light or remove if not needed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2018
Resolved
Re-label stowage location for childs PFDs.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 4 June 2018
Resolved
Ensure all required portable fire extinguishers are installed in brackets.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 June 2018
Resolved
Adjust fire hydrant ensuring connection of hose is easily accomplished during an emergency.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2018
Resolved
Renew all expired first aid kit contents.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2018
Resolved
Ensure vessel is equipped with 67 PFDs (Type I). Until then, passenger capacity is reduced to 61 plus 3 crew - pending pax redux request.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2018
Resolved
Identify source of salt build-up at MSD discharge and prove sound - at dry-dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 4 June 2018
Resolved
Demonstrate operation of GENSET or remove - by dry-dock.
Engineering › Bilge Water Management System › Piping
Issued 8 May 2017
Resolved
Demonstrate operation of fixed and electric bilge pumping capability in each compartment prior to carrying passengers.
Stability › Watertight Integrity › General
Issued 8 May 2017
Resolved
Make engineroom hatch watertight.
Stability › Watertight Integrity › General
Issued 8 May 2017
Resolved
Re-attach captive wires to each hatch and secure within vessel.
Lifesaving › Lifefloat › Serviceable
Issued 8 May 2017
Resolved
Either renew or refurbish lifefloats to ensure color is safety orange and grablines/webbing is securely attached.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 8 May 2017
Resolved
Ensure operation of stern light prior to operation after sunset or before sunrise.
Documentation › Markings/Placards › Capacity Marking
Issued 8 May 2017
Resolved
Label upper deck for maximum passengers.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 8 May 2017
Resolved
Remove oily water from bilge area of engineroom.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017
Resolved
Install proper connection for wires on forward engineroom bulkhead, currently secured with bolt/nut assembly
Deck/Cargo › Mooring/Anchoring › Winch
Issued 8 May 2017
Resolved
Re-run hydraulilc hose at fwd port MDE removing it from weaving w/in coolanthose. Secure it in hangers.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 8 May 2017
Resolved
Develop and implement a means to record/log crew training, drillsw & EPIRB testing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017
Resolved
Remove all wiring currently installed on vessel that is not providing electricity to installed equipment or is "dead-ended".
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2016
Resolved
Identify electrical junction in way of forward engineroom, install within an approved typ[e enclosure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 October 2016
Resolved
Remove wiring found melted to stbd outboard exhaust manifold.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 June 2016
Resolved
Prior to operation, ensure current/valid certificate of documentation is on board vessel.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 29 June 2016
Resolved
Noted 63 adult PFDs on board vessel. Until additional adult PFDs are provided, passenger count is reduced to 60 adults.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 29 June 2016
Resolved
Ensure all PFD stowage locations are marked with adult/child and number within.
Lifesaving › Lifebuoys › Serviceable
Issued 29 June 2016
Resolved
Ensure ring lifebuoy has waterlight, retro tape and 60 feet of line attached.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 June 2016
Resolved
Repair starboard battery tray to prevent shifting/movement of batteries.
Engineering › Diesel Engine (auxiliary) › Silencer (exhaust)
Issued 29 June 2016
Resolved
Securely mount generator exhaust muffler.
Stability › Watertight Integrity › General
Issued 29 June 2016
Resolved
Make hatch to the steering compartment watertight.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 29 June 2016
Resolved
Install proper bracket for portable fire extinguisher located above access to engine room.
Documentation › Markings/Placards › Capacity Marking
Issued 29 June 2016
Resolved
Mark upper deck for maximum number of persons.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 29 June 2016
Resolved
Provide a means to secure overboard discharge from MSD
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2014
Resolved
Seal two penetrations in aft engine room bulkhead.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 October 2014
Resolved
Seal two holes in collision bulkhead.
Stability › Unintentional Flooding › General
Issued 27 October 2014
Resolved
Replace the two bomar hatch gaskets.
Construction/Loadline › Structures › Deck Plating
Issued 27 October 2014
Resolved
Remove angel hair from engine room overhead deckbeams and make ready inspection.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 27 October 2014
Resolved
Remove portable fuel tank from engine room.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 October 2014
Resolved
Double hose clamp all exhaust piping.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 October 2014
Resolved
Renew exhaust hose on generator.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2014
Resolved
Secure all loose wiring and remove deadend wiring as discussed with the CGMI.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 27 October 2014
Resolved
Repair leak on L/O cooler.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 October 2014
Resolved
Install bonding wire for fuel tank fill.
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 27 October 2014
Resolved
Tighten all handrails and re-weld broken handrail on upper deck aft stantion.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 October 2014
Resolved
Submit plans for two new fuel tanks that were installed May 2014 without CG oversight.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 June 2014
Resolved
Show proof of current FCC Safety Radio Certificate, vessel is restricted to operating nmt 1000 feet from shore.
Lifesaving › Lifefloat › Float Free
Issued 22 May 2012
Resolved
Properly install spacers between life-floats.
Engineering › Fuel Oil Service System › Valve
Issued 22 May 2012
Resolved
Properly label fuel shut-off valve.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 May 2012
Resolved
Remove all dead end wires or properly terminate.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 May 2012
Resolved
Properly install machinery belt guards on both MDE's and aux generator.
Fire Fighting › Fire Hoses › Condition
Issued 22 May 2012
Resolved
Replace fire hose with approved type.
Lifesaving › Hand Flares › Quantity
Issued 22 May 2012
Resolved
Provide two additional red flares.
Stability › Watertight Integrity › General
Issued 6 November 2008
Resolved
Renew gaskets on all scuttles and hatches.
Construction/Loadline › Hull › Bottom Plating
Issued 6 November 2008
Resolved
Grind to good material all areas indicated by marine inspector and call for follow up inspection.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 5 May 2008
Resolved
Prove proper operation of engine shutdowns upon fixed F/F system activation.
Fire Fighting › Fire Hydrants › Condition
Issued 5 May 2008
Resolved
Provide fire extinguisher service report for all portable extinguisher.
Electrical › Electric Supply System (service) › Cable
Issued 5 May 2008
Resolved
Install metallic cable hangers with rubber insert at 24 inch support intervals.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 May 2008
Resolved
Install guards around rotating machinery in engine room (3 engines).
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 5 May 2008
Resolved
Renew generator exhaust line near the manifold, T connection wasted.
Engineering › Reduction Gearing/Clutches › Bolt
Issued 5 May 2008
Resolved
Renew STBD engine/reduction gear - shift cable.
Engineering › Fuel Oil Service System › Filter
Issued 5 May 2008
Resolved
Install ball valve at the racor fuel filter.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 May 2008
Resolved
Install ladder in fuel tank space for access. The ladder shall be 7" minimum from the bulkhead.
Engineering › Bilge Water Management System › Piping
Issued 5 May 2008
Resolved
Install check valves at all bilge strainers.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 5 May 2008
Resolved
Renew anchor hydraulic hoses with approved hose.
Engineering › Bilge Water Management System › Pump
Issued 5 May 2008
Resolved
Renew electrical submersible pumps with UL approved pumps.
Engineering › Bilge Water Management System › Not Operational
Issued 5 May 2008
Resolved
Prove proper operation of installed bilge system.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2008
Resolved
Provide complete first aid kit IAW 184.710.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 May 2008
Resolved
Provide non-corrosive clip attaching water-light to the ring buoy.
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 May 2008
Resolved
Prove proper operation of high water bilge alarms.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 5 May 2008
Resolved
Provide FCC Radio Safety Certificate.
Lifesaving › Lifefloat › Float-free Link
Issued 5 May 2008
Resolved
Provide proper size weak link for 22 person L/F.
Lifesaving › Lifefloat › Paddle
Issued 5 May 2008
Resolved
Provide 2 4' paddles for each L/F IAW 46CFR180.175.
Communications › Radio Communications › EPIRB
Issued 19 April 2006
Resolved
Renew hydro release.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 April 2006
Resolved
Found navigation lights inoperative. Vessel restricted to daylight operations only, unlimited visibility.
Lifesaving › Lifejacket/PFD (General)
Issued 25 June 2002
Resolved
REPLACE RETROREFLECTIVE TAPE ON 10 ADULT LIFEJACKETS AND 03 CHILD LIFE JACKETS LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Lifebuoys
Issued 25 June 2002
Resolved
MARK LIFE RING BUOY (SHIP NAME/PORT) LEGACY COMPONENT DESC: Markings (ship name/port)
Engineering › Sea-water System (primary cooling)
Issued 25 June 2002
Resolved
REPLACE DAMAGED PORT EXHAUST TUBE LEGACY COMPONENT DESC: Piping
Engineering › Bilge Water Management System
Issued 25 June 2002
Resolved
CLEAN AND FLUSH ALL OIL RESIDUE IN THE BILGE MANIFOLD SYSTEM. LEGACY COMPONENT DESC: Manifold
Deck/Cargo › Holds/Tanks
Issued 25 June 2002
Resolved
CLEAN TANK ROOM OF ALL RESIDUAL FUEL
Engineering › Feedwater/Condensate Water System
Issued 25 June 2002
Resolved
DOUBLE CLAMP TOILET AND AND WASHDOWN HOSES FROM THROUGH HULL TO PUMP. LEGACY COMPONENT DESC: SEAWATER SUPPLY TOILET/WASHDOWN SYSTEM
Engineering › Bilge Water Management System
Issued 25 June 2002
Resolved
PROPERLY MOUNT ELECTRIC BILGE PUMP IN ENGINE ROOM LEGACY COMPONENT DESC: Pump
Engineering › Fuel Oil Service System
Issued 25 June 2002
Resolved
PREVENT CHAFING OF FUEL SHUT OFF VALVE PORT SIDE LEGACY COMPONENT DESC: EMERGENCY SHUT OFF VALVE
Engineering › Bilge Water Management System
Issued 25 June 2002
Resolved
REPAIR HIGH LEVEL ALARM WARNING LIGHT AT OPERATING STATION LEGACY COMPONENT DESC: BILGE HIGH LEVEL ALARM
Construction/Loadline › Hull
Issued 25 June 2002
Resolved
MAKE PERMENANT REPAIR TO RAILS LEGACY COMPONENT DESC: RAILS
Navigation
Issued 19 June 2001
Resolved
MAKE PERMANENT REPAIRS TO STEERING SYSTEM'S RAM TO PREVENT CHAFFING.
Lifesaving
Issued 19 June 2001
Resolved
PROVIDE 2 PADDLES FOR EACH L/F
Lifesaving
Issued 19 June 2001
Resolved
MARK PADDLES
Construction/Loadline
Issued 19 June 2001
Resolved
PROVE PROPER OPERATION OF TANK ROOM BILGE HIGH LEVEL ALARM
Fire Fighting
Issued 19 June 2001
Resolved
PROVE PROPER OPERATION OF GENERATOR SHUT DOWN WITH FIXED FIRE FIGHITNG SYS.
Lifesaving
Issued 19 June 2001
Resolved
MARK UPPER DECK WITH MAX PASSENGERS
Lifesaving
Issued 19 June 2001
Resolved
MARK LIFE FLOATS
Lifesaving
Issued 19 June 2001
Resolved
REMOVE OIL IN BILGES
Construction/Loadline
Issued 19 June 2001
Resolved
PROVE PROPER OPERATION OF FIXED BILGE PIPING SYSTEM.
Lifesaving
Issued 20 April 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 20 April 2000
Resolved
TIGHTEN STBD RUDDER POST PACKING COUPLING
Lifesaving
Issued 20 April 2000
Resolved
PROVIDE FLAME IMPINGEMENT BOWL FOR RACOR FILTERS
Navigation
Issued 20 April 2000
Resolved
POST DEVIATION TABLE
Lifesaving
Issued 20 April 2000
Resolved
CORRECTLY MARK PFD LOCKER FOR ADULTS
Lifesaving
Issued 20 April 2000
Resolved
MARK CHILD'S PFD LOCKER
Navigation
Issued 20 April 2000
Resolved
PROVIDE NAV PUBS
Lifesaving
Issued 20 April 2000
Resolved
REMOVE OIL FROM ENGINE ROOM
Navigation
Issued 20 April 2000
Resolved
MAKE OPERATIONAL NAV LIGHTS
Documentation
Issued 20 April 2000
Resolved
PROVIDE VALID RADIO TELEPHONY CERT
Unknown
Issued 29 June 1999
Resolved
PAY USER FEE
Fire Fighting
Issued 29 June 1999
Resolved
PROVE PROPER OPERATION OF GENERATOR SHUT DOWN WITH FIXED FIRE FIGHTING SYSTEM
Unknown
Issued 29 June 1999
Resolved
ENSURE 50PCT OF CREW IS SUBJECT TO RANDOM SCREENING PROCESS
Unknown
Issued 29 June 1999
Resolved
PROVIDE PROOF THAT SUPERVISOR HAS RCVD T50MINUTE TRAINING.
Unknown
Issued 29 June 1999
Resolved
POST EMPLOYEE ASSIST PROGRAM POLICY AND TOLL FREE NUMBER
Unknown
Issued 29 June 1999
Resolved
FILE MIS REPORT ANNUALLY
Lifesaving
Issued 29 June 1999
Resolved
MAKE PERM REPAIRS TO STBD HAND RAIL AMIDSHIP (BROKEN)
Unknown
Issued 29 June 1999
Resolved
PROVIDE UPDATED CREW LIST
Construction/Loadline
Issued 29 June 1999
Resolved
PROVE PROPER OPERATION OF BILGE PUMP IN AFT TANK COMPARTMENT
Unknown
Issued 29 June 1999
Resolved
PROVIDE DAPI CONTRACT OR DEVELOP A DRUG SCREENING PROGRAM
Fire Fighting
Issued 11 June 1998
Resolved
PROVIDE PROOF OF ANNUAL SERVICING FOR PORTABLE FIRE EXTINGUISHERS.
Electrical
Issued 11 June 1998
Resolved
PROVIDE ACCEPTABLE CABLE RUNS AND INSTALL ADEQUATE METAL FASTENERS FOR WIRERUNS THROUGHOUT THE MACHINERY SPACE.
Documentation
Issued 11 June 1998
Resolved
PROVIDE COPY OF VALID RADIO OPERATOR'S PERMIT.
Fire Fighting
Issued 24 April 1997
Resolved
REPLACE 2 B-II FIRE EXTINGUISHERS WITH NEW
Navigation
Issued 24 April 1997
Resolved
RENEW CHAFFED STEERING GEAR HOSE
Lifesaving
Issued 24 April 1997
Resolved
INSTALL NEW RETRO-REFLECTIVE TAPE ON ALL 4 BAs
Lifesaving
Issued 24 April 1997
Resolved
RENEW DETERIORATED LINES ON BAs
Lifesaving
Issued 24 April 1997
Resolved
MOUNT EPIRB
Documentation
Issued 24 April 1997
Resolved
ADD EPIRB TO FCC STATION LICENSE
Electrical
Issued 24 April 1997
Resolved
REPAIR BATTERY CUTOUT SWITCHES
Lifesaving
Issued 24 April 1997
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON RING BUOY ON 4 EQUALLY SPACED AREAS
Documentation
Issued 24 April 1997
Resolved
POST EMERGENCY BROADCAST PLACARD
Lifesaving
Issued 24 April 1997
Resolved
RENEW DETERIORATED LINE ON RING BUOY- 60 FOOT
Documentation
Issued 24 April 1997
Resolved
PROVIDE DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 CFR PART 16
Lifesaving
Issued 10 May 1996
Resolved
RENEW B/A REFLECTIVE TAPE
Lifesaving
Issued 10 May 1996
Resolved
PROVIDE BRIGHTLY COLORED FLARE CONTAINER
Lifesaving
Issued 10 May 1996
Resolved
RENEW RING BUOY WATERLIGHT
Lifesaving
Issued 10 May 1996
Resolved
RENEW ALL WATERLIGHT BATTERIES
Construction/Loadline
Issued 10 May 1996
Resolved
LABEL BILGE MANIFOLD
Fire Fighting
Issued 10 May 1996
Resolved
RENEW ONE FIRE EXTINGUISHER
Lifesaving
Issued 10 May 1996
Resolved
RELABEL B/A WITH VESSEL NAME
Construction/Loadline
Issued 10 May 1996
Resolved
PROVIDE CHECK VALVES IN ALL BILGE SUCTIONS
Construction/Loadline
Issued 10 May 1996
Resolved
PROVIDE STRAINERS IN ALL BILGE SUCTION LINES
Construction/Loadline
Issued 10 May 1996
Resolved
REPAIR TANK ROOM BILGE SUCTION PIPING
Construction/Loadline
Issued 10 May 1996
Resolved
RENEW ENGINEROOM BILGE SUCTION PIPING
Documentation
Issued 16 May 1995
Resolved
PROVIDE MASTERS LICENSE _x001C_ TO BE PROVIDED PRIOR TO CARRAGE OF PASSENGERS
Construction/Loadline
Issued 16 May 1995
Resolved
RENEW ROTTED DECK FORWARD AND AFT
Documentation
Issued 16 May 1995
Resolved
PROVIDE FCC STATION LICENSE
Lifesaving
Issued 16 May 1995
Resolved
RENEW REFLECTIVE TAPE ON ALL FOUR BA's
Fire Fighting
Issued 16 May 1995
Resolved
PROVIDE HAND FIRE AND BILGE PUMP_x001C_ _x001C_ TO BE CORRECTED PRIOR TO THE CARRAGE OF PASSENGERS
Electrical
Issued 16 May 1995
Resolved
REPAIR UPPER DECK FLOOD LIGHTS
Accommodation/Occupational Safety
Issued 16 May 1995
Resolved
REPAIR WATER TANK FILL AND VENT
Documentation
Issued 16 May 1995
Resolved
PROVIDE DRUG TESTING PROGRAM IN ACCORDANCE WITH 46 AND 49 CFR.
Construction/Loadline
Issued 16 May 1995
Resolved
INSTALL VALVE HANDLE ON BILGE SUCTION VALVE FOR ENGINEROOM_x001C_ _x001C_ TO BE CORRECTED PRIOR TO CARRAGE OF PASSENGERS
Navigation
Issued 16 May 1995
Resolved
REPAIR STERN LIGHT
Fire Fighting
Issued 28 April 1994
Resolved
PROVIDE MARINE BRACKET FOR PILOT HOUSE B-I FIRE EXTINGUISHER
Lifesaving
Issued 28 April 1994
Resolved
RENEW LIGHT FOR ONE BUOYANT APPARATUS _x001C_ _x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 72 PERSONS ONBOARD UNTIL CORRECTED
Lifesaving
Issued 28 April 1994
Resolved
RENEW GRAB LINE FOR ONE BUOYANT APPARATUS
Lifesaving
Issued 28 April 1994
Resolved
INSTALL REFLECTIVE TAPE ON ALL BUOYANT APPARATUS_x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 28 April 1994
Resolved
LABEL PFD STOWAGE IN MAIN CABIN
Electrical
Issued 28 April 1994
Resolved
INSTALL BULBS AND LENS IN LIGHTS IN BOTH HEADS
Engineering
Issued 28 April 1994
Resolved
INSTALL REMOTE FUEL SHUT OFF VALVE FOR GENERATOR
Accommodation/Occupational Safety
Issued 28 April 1994
Resolved
REFASTEN LOOSE SEAT IN MAIN CABIN_x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 28 April 1994
Resolved
PLUG FUEL FILTER DRAINS
Engineering
Issued 28 April 1994
Resolved
RENEW PORT AND STARBOARD ENGINE REVERSE GEAR FLEX HOSES
Engineering
Issued 28 April 1994
Resolved
RENEW CONNECTION ASSEMBLY FOR SHIFT LEVERS BOTH REVERSE GEARS
Fire Fighting
Issued 28 April 1994
Resolved
RENEW FIRE PUMP SUCTION AND DISCHARGE HOSES
Navigation
Issued 28 April 1994
Resolved
RENEW STEERING GEAR FLEX HOSE (ROD END)
Engineering
Issued 28 April 1994
Resolved
INSTALL GROUND WIRE BETWEEN FUEL TANK AND FILL CONNECTION
Engineering
Issued 28 April 1994
Resolved
INSTALL 30 MESH FLAME SCREEN IN FUEL TANK VENT
Lifesaving
Issued 28 April 1994
Resolved
RENEW ONE BUOYANT APPARATUS OR REPAIR IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS_x001C_ _x001C_ VESSEL RESTRICTED TO NOT MORE THAN 72 PERSONS ON BOARD UNTIL CORRECTED
Engineering
Issued 30 April 1993
Resolved
MOVE VENT SCREENING FROM THE BOTTOM TO THE TOP OF THE AIR INTAKE VENTS ON BOTH THE PORT AND STARBOARD SIDES.
Deck/Cargo
Issued 30 April 1993
Resolved
REPAIR LEAK IN HYDRAULIC LINE TO ANCHOR WINDLASS PASSING THROUGH THE MAIN STORAGE SPACE FORWARD OF THE E/R.
Lifesaving
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE TWO ADDITIONAL ADULT PFD'S. UNTIL SUCH TIME, TOTAL PERSONS ALLOWED IS REDUCED TO 87.
Lifesaving
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, INSTALL A FLOAT FREE LINK IN ACCORDANCE WITH 46 CFR 180.20-1.
Construction/Loadline
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, REPAIR/REPLACE FORE PEAK HATCH AND PROVE WATERTIGHT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving
Issued 30 April 1993
Resolved
RESTENCIL LIFEJACKET STORAGE LOCKERS ON 2ND DECK TO REFLECT 32 ADULT PFD'S.
Construction/Loadline
Issued 30 April 1993
Resolved
SECURE ELECTRICAL BILGE WIRING IN THE TANK SPACE SUCH THAT ALL SPLICES REMAIN OUT OF THE BILGES.
Lifesaving
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED CREWMEMBERS.
Lifesaving
Issued 30 April 1993
Resolved
THE MASTER SHALL CONDUCT EMERGENCY DRILLS INCLUDING MAN OVERBOARD, FIRE, FLOODING, LOSS OF PROPULSION AND ABANDON SHIP WITH ALL NORMALLY ASSIGNED CREWMEMBERS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Lifesaving
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, RESTOW RING BUOY AND SHOW PROPER OPERATION OFTHE WATERLIGHT.
Fire Fighting
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, PROVE OPERATION OF THE VESSELS FIRE PUMP.
Documentation
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE A VALID LICENSE FOR THE TRADE IN WHICH ENGAGED.
Electrical
Issued 30 April 1993
Resolved
PRIOR TO CARRYING PASSENGERS, CLEAN AND SECURE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR ALL WIRING LEADING TO BOTH PORT AND STARBOARD SERIES PARALLEL SWITCHES.
Engineering
Issued 30 April 1993
Resolved
INSTALL EXHAUST LAGGING AROUND EXPOSED EXHAUST ELBOWS AND RUNS ON BOTH PORTAND STARBOARD INBOARD AND OUTBOARD EXHAUST PIPES ON THE MDE'S.
Documentation
Issued 30 April 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 6 April 1993
Resolved
PRIOR TO PLACING VESSEL IN SERVICE WITH PASSENGERS CONDUCT OPERATIONAL TESTAND PROVE PROPER OPERATION OF NEWLY INSTALLED STEERING SYSTEM IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR .
Documentation
Issued 30 April 1992
Resolved
STABILITY LETTER NOT POSTED. POST STABILITY IN PILOT HOUSE UNDER GLASS OR OTHER SUITABLE MATERIAL.
Accommodation/Occupational Safety
Issued 30 April 1992
Resolved
LIFERAIL STARBOARD SIDE MAIN DECK MISSING NUMEROUS SCREWS. PROPERLY SECURESTARBOARD LIFERAIL.
Lifesaving
Issued 30 April 1992
Resolved
MARKING ON BUOYANT APPARATUS FADED. REMARK NUMBER OF PERSONS AND VESSEL NAME ON BUOYANT APPARATUS
Lifesaving
Issued 30 April 1992
Resolved
LIFE PRESERVER STORAGE LOCKERS NOT PROPERLY MARKED. MARK LIFE PRESERVER STORAGE LOCKERS.
Electrical
Issued 30 April 1992
Resolved
EXTERIOR LIGHT FIXTURE WIRES EXPOSED FIXTURE MISSING. PROPERLY STOP WIRES OR RESECURE FIXTURE.
Accommodation/Occupational Safety
Issued 28 September 1989
Resolved
PROVE PROPER OPERATION OF TOILETS.
Construction/Loadline
Issued 28 September 1989
Resolved
PROVE FORE PEAK WATERTIGHT.
Engineering
Issued 28 September 1989
Resolved
REPAIR LEAKS IN EXHAUST RISERS.
Deck/Cargo
Issued 28 September 1989
Resolved
REPAIR AFTER STEERING SPACE BILGE STRAINER.
Engineering
Issued 28 September 1989
Resolved
INSTALL PROPER FUEL OIL HOSE ON FUEL TANK FILL PIPES WITH BONDING WIR.
Fire Fighting
Issued 28 September 1989
Resolved
PROVE PROPER OPERATION OF FIRE/BILGE PUMP.
Lifesaving
Issued 28 September 1989
Resolved
PROVE PROPER OPERATION OF FLOAT LIGHT.
Construction/Loadline
Issued 28 September 1989
Resolved
CLEAN OIL FROM BILGES.
Construction/Loadline
Issued 28 September 1989
Resolved
ATTACH AFTER STEERING DECK HATCH SAFETY WIRE PROPERLY. * ALL DEFICIENCIES (#1-#13) TO BE CORRECTED PRIOR TO CARRYING PASSENGERS.
Engineering
Issued 28 September 1989
Resolved
INSTALL PROPER RUBBER HOSE IN MAIN ENGINE EXHAUSTS WITH SUFFICIENT SUPPORT.
Accommodation/Occupational Safety
Issued 28 September 1989
Resolved
INSTALL TWO (02) HOSE CLAMPS ON SANITARY SALT WATER PUMP THRU HULL.
Engineering
Issued 28 September 1989
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE THROTTLE & GEAR CONTROLS.
Navigation
Issued 28 September 1989
Resolved
PROVE STEERING GEAR FREE OF HYDRAULIC LEAKS.
Casualty record · 1
10 October 2024Routine · role: Involved in a Marine Casualty · at STAURT CAUSEWAY BRIDGE · activity 8022436
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.