Records from 1985 to 2007. Most recent: inspection, 14 November 2007.
Inspection history · 60
14 November 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3098097
17 April 2007
Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2909255
27 September 2006
Re-Inspection · Ballast Water Examination · Damage Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2788011
17 April 2006
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2626499
23 January 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571570
13 June 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2389474
4 March 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303726
14 February 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293062
14 February 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293630
10 February 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290205
2 February 2005
Examination of Repairs · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2285531
1 November 2004
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232676
23 June 2004
MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066450
26 May 2004
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079229
14 March 2004
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2017172
28 October 2003
Deficiency Check · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1928669
18 August 2003
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1879552
12 July 2003
Periodic Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1833210
1 May 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1611620
13 September 2001
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1443246
21 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066967
25 April 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062198
2 March 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059899
2 March 2001
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1065306
3 March 2000
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815504
3 March 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403209
10 December 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453692
19 July 1999
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102707
5 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 44279
24 November 1998
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 806289
1 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 149422
19 November 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416597
9 September 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786625
26 November 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467948
29 August 1996
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1437141
5 January 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404060
15 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163829
30 November 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459133
6 January 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 850582
12 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 850638
1 December 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425376
19 November 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415920
21 September 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157646
24 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401723
30 December 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462320
6 March 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260849
21 March 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929626
23 January 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899853
17 January 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241367
22 December 1989
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239714
18 February 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043474
26 January 1989
MARPOL Annex II Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036136
27 June 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206364
13 April 1988
Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037758
27 February 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010484
10 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013834
26 January 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318224
20 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297363
25 April 1986
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 998761
15 March 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1289588
Engineering › Shafting/Propeller Arrangements
Issued 3 March 2004
Resolved
Prove proper operation of the Port Shaft Tachometer LEGACY COMPONENT DESC: shaft tackometer
Condition: Unknown
Due 17 April 2004
Resolved 27 April 2004
Resolution: Received letter of confirmation that the shaft Tachometer was working properly.
Lifesaving › Line-Throwing Appliances
Issued 3 March 2004
Resolved
Provide 20 new line throwing gun shells. LEGACY COMPONENT DESC: Projectiles
Due 17 April 2004
Resolved 27 April 2004
Resolution: Received confirmation that 20 new line throwinggun shell were onboard.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 3 March 2004
Resolved
Prior to next Coast Guard inspection provide approved Fire Extingishers to replace the current extinguishers approved by foreign equivilant. LEGACY COMPONENT DESC: Marking
Condition: Placed in Improper Service
Due 3 March 2005
Resolved 2 February 2005
Resolution: All fire extinguishers on board vessel are approved.
Engineering
Issued 3 March 2004
Resolved
Prove proper operation of vital system automation using approved test procedures. LEGACY COMPONENT DESC: Automation
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 3 March 2004
Resolved
Prove proper operation of installed marine sanitation system to include at least 3 working toilets.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: System was functional at end of inspection but should be monitored during future inspections.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2004
Resolved
Remove non-approved bilge discharge piping in way of shaft gland cofferdams and permanently blank off direct overboard discharge.
Condition: Improper Installation
Due 17 March 2004
Resolved 17 March 2004
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 March 2004
Resolved
Adjust packing glands on propulsion shafts excessive leakage.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Lifesaving › Embarkation Appliances/Stations
Issued 3 March 2004
Resolved
Install new embarkation ladders of proper length.
Condition: Improper Installation
Due 17 March 2004
Resolved 17 March 2004
Resolution: New ladders installed
Electrical
Issued 3 March 2004
Resolved
Propery install electrical runs and remove all dead end wires. Numerous examples of improper wiring. LEGACY COMPONENT DESC: Electrical wire runs
Condition: Improper Installation
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected wiring installations.
Stability › Weathertight Integrity
Issued 3 March 2004
Resolved
Renew leaking seals associated with the Shark Jaws. LEGACY COMPONENT DESC: Shark Jaw Seals
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Renewed seals.
Engineering
Issued 3 March 2004
Resolved
Identify all remote emergency stop switches and prove proper operation. LEGACY COMPONENT DESC: Emergency stop switches
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Lifesaving › Inflatable Liferafts
Issued 12 July 2003
Resolved
Provide 2ea. Coast Guard approved liferafts with current year Coast Guard decals.
Due 26 July 2003
Resolved 28 July 2003
Navigation › Piloting/Steering
Issued 12 July 2003
Resolved
Prove proper operation of follow-up steering (servo's/limkage adjustment).
Due 26 July 2003
Resolved 28 July 2003
Navigation › Piloting/Steering
Issued 12 July 2003
Resolved
Prove proper operation of port shaft tach.
Due 12 August 2003
Resolved 30 July 2003
Lifesaving › Embarkation Appliances/Stations
Issued 12 July 2003
Resolved
Prove proper operation of port embarkation light.
Due 26 July 2003
Resolved 28 July 2003
Fire Fighting › Fire Main
Issued 12 July 2003
Resolved
Prove proper operation of bridge firemain pressure guage.
Due 12 August 2003
Resolved 11 August 2003
Construction/Loadline › Hull
Issued 1 May 2002
Resolved
Crop and properly renew wasted hull plating, starboard side, below starboard main engine shaft. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 02.
Construction/Loadline › Structures
Issued 1 May 2002
Resolved
Crop and properly renew wasted no. 5 starboard tank forward bulkhead. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002
Resolved
Crop and properly renew wasted no. 2 port tank forward bulkhead. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002
Resolved
Crop and properly renew after pilot house window framing. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Hull
Issued 1 May 2002
Resolved
Crop and properly renew damage to port side exhaust trunk. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002
Resolved
Marine Inspector must inspect repair and witness air-test of no. 2 starboard ballast tank. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Engineering › Lubricating Oil Storage/Transfer System
Issued 1 May 2002
Resolved
Remove soft patching from main engine lube oil tank, port side. Provide inspection of repair to the satisfaction of a Marine Inspector. LEGACY COMPONENT DESC: Tank
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Accommodation/Occupational Safety › Ventilation
Issued 1 May 2002
Resolved
Install proper metal vent material in clothes dryer exhaust. LEGACY COMPONENT DESC: Clothes Dryer vent
Condition: Improper Installation
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002
Resolved
Crop and renew wasted areas in port side of pilot house IWO emergency battery boxes. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 May 2002
Resolved
Repair/renew bent main deck railing throughout vessel. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Hull
Issued 1 May 2002
Resolved
Crop and renew damaged rub railing along port side of vessel. LEGACY COMPONENT DESC: Collision Strap
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Operations/Management › Drills/Instruction
Issued 1 May 2002
Resolved
Provide new liferaft embarkation instructions on both port and starboard side. LEGACY COMPONENT DESC: Abandon Ship
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Deck/Cargo › Cargo Stowage
Issued 1 May 2002
Resolved
Replace main deck cargo tie-downs as necessary. LEGACY COMPONENT DESC: Cargo tie-downs
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey reported dated 02 May 2002.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 May 2002
Resolved
Repair damaged ladder starboard side main deck. LEGACY COMPONENT DESC: ladder
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Lifesaving
Issued 2 March 2001
Resolved
Replace proper line on all ring buoys.
Condition: Unknown
Due 7 March 2001
Resolved 16 March 2001
Electrical
Issued 2 March 2001
Resolved
Replace wasted 225V wire runs atop pilothouse and properly fasten in metal clips provided.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Navigation
Issued 2 March 2001
Resolved
Repair GMDSS and demonstrate test and and use to USCG inspector.
Condition: Unknown
Due 7 March 2001
Resolved 16 March 2001
Electrical
Issued 2 March 2001
Resolved
Provide additional 110V AC circuits on bridge as required by 46 CFR 111.60.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 10 December 1999
Resolved
PROVIDE PROOF OF COMPLIANCE WITH D8 RESCUE BOAT REQUIREMENT DATED 12NOV98 NO LATER THAN 24NOV00.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 30 November 1994
Resolved
FIXED FF HALON BOTTLES NOT HYDRO TESTED AS REQUIRED. SYSTEM NOT REQUIRED ONVESSEL.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Documentation
Issued 17 January 1991
Resolved
PROVIDE CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY WITH CURRENT OWNER/OPERATOR AND CURRENT NAME AS REQUIRED BY FEDERAL WATER POLLUTION CONTROL_x001C_ ACT SECTION 311(P)
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Unknown
Issued 26 January 1989
Resolved
REPAIR OILY WATER SEPERATOR IN ACCORDANCE WITH INTERNATIONAL OIL POLLUTION PREVENTION REGULATIONS ENSURING MAX. PPM ALARM AND PPM DISPLAY ARE OPERATING PROPERLY.
Condition: Unknown
Due 26 January 1989
Resolved 26 January 1989
Unknown
Issued 26 January 1987
Resolved
PRIOR TO SERVICE DUE DATE, 27FEB87, HAVE BOTH OF VESSEL'S LIFERAFTS SERVICED.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987