MAURY USCG vessel records Sign in
← All vessels

SEACOR FORCE

SEACOR FORCE is a 1985 offshore supply vessel. The Coast Guard has recorded 60 inspections since 1985, most recently in November 2007, along with 39 deficiencies.

Records from 1985 to 2007. Most recent: inspection, 14 November 2007.

Built
1985
Last inspected
14 November 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8216423 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WAS2425
248142
Flag
UNITED STATES
367691000 (licence lapsed)
Maury page id
psix-248142

Inspections, by type

…with no type recorded10
Years with a record 21 calendar years (1985–2007)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it999 - Convention (Subpart B), Gross Ton
483 - Regulatory (Subpart C or D), Gross Ton
299 - Convention (Subpart B), Net Ton
329 - Regulatory (Subpart C or D), Net Ton
1155 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WAS2425MMSI 367691000 · cancelled · compulsorily equipped · granted 15 February 2006, cancelled 1 April 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

GOLDEN ANCHOR Towing Vessel · MISLE 200777 · 1 June 1998 · activity 149422

Inspection history · 60

14 November 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3098097
17 April 2007 Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2909255
27 September 2006 Re-Inspection · Ballast Water Examination · Damage Survey · MARPOL Annex I Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2788011
17 April 2006 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2626499
23 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2571570
13 June 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2389474
4 March 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2303726
14 February 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293062
14 February 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2293630
10 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2290205
2 February 2005 Examination of Repairs · Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2285531
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232676
23 June 2004 MTSA/ISPS Verification
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2066450
26 May 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079229
14 March 2004 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2017172
28 October 2003 Deficiency Check · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1928669
18 August 2003 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1879552
12 July 2003 Periodic Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1833210
1 May 2002 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1611620
13 September 2001 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1443246
21 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066967
25 April 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1062198
2 March 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1059899
2 March 2001 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1065306
3 March 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 815504
3 March 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403209
10 December 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453692
19 July 1999 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102707
5 July 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 44279
24 November 1998 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 806289
1 June 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 149422
19 November 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416597
9 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786625
26 November 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467948
29 August 1996 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1437141
5 January 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1404060
15 December 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163829
30 November 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459133
6 January 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 850582
12 December 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 850638
1 December 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425376
19 November 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415920
21 September 1993 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1157646
24 June 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401723
30 December 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462320
6 March 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1260849
21 March 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929626
23 January 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899853
17 January 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241367
22 December 1989 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239714
18 February 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043474
26 January 1989 MARPOL Annex II Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036136
27 June 1988 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1206364
13 April 1988 Re-Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1037758
27 February 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010484
10 February 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013834
26 January 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318224
20 June 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297363
25 April 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 998761
15 March 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1289588

Deficiency record · 39

Engineering › Shafting/Propeller Arrangements
Issued 3 March 2004 Resolved
Prove proper operation of the Port Shaft Tachometer LEGACY COMPONENT DESC: shaft tackometer
Condition: Unknown
Due 17 April 2004
Resolved 27 April 2004
Resolution: Received letter of confirmation that the shaft Tachometer was working properly.
Lifesaving › Line-Throwing Appliances
Issued 3 March 2004 Resolved
Provide 20 new line throwing gun shells. LEGACY COMPONENT DESC: Projectiles
Due 17 April 2004
Resolved 27 April 2004
Resolution: Received confirmation that 20 new line throwinggun shell were onboard.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 3 March 2004 Resolved
Prior to next Coast Guard inspection provide approved Fire Extingishers to replace the current extinguishers approved by foreign equivilant. LEGACY COMPONENT DESC: Marking
Condition: Placed in Improper Service
Due 3 March 2005
Resolved 2 February 2005
Resolution: All fire extinguishers on board vessel are approved.
Engineering
Issued 3 March 2004 Resolved
Prove proper operation of vital system automation using approved test procedures. LEGACY COMPONENT DESC: Automation
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 3 March 2004 Resolved
Prove proper operation of installed marine sanitation system to include at least 3 working toilets.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: System was functional at end of inspection but should be monitored during future inspections.
Engineering › Bilge Water Management System › Piping
Issued 3 March 2004 Resolved
Remove non-approved bilge discharge piping in way of shaft gland cofferdams and permanently blank off direct overboard discharge.
Condition: Improper Installation
Due 17 March 2004
Resolved 17 March 2004
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 3 March 2004 Resolved
Adjust packing glands on propulsion shafts excessive leakage.
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Lifesaving › Embarkation Appliances/Stations
Issued 3 March 2004 Resolved
Install new embarkation ladders of proper length.
Condition: Improper Installation
Due 17 March 2004
Resolved 17 March 2004
Resolution: New ladders installed
Electrical
Issued 3 March 2004 Resolved
Propery install electrical runs and remove all dead end wires. Numerous examples of improper wiring. LEGACY COMPONENT DESC: Electrical wire runs
Condition: Improper Installation
Due 17 March 2004
Resolved 17 March 2004
Resolution: Corrected wiring installations.
Stability › Weathertight Integrity
Issued 3 March 2004 Resolved
Renew leaking seals associated with the Shark Jaws. LEGACY COMPONENT DESC: Shark Jaw Seals
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Resolution: Renewed seals.
Engineering
Issued 3 March 2004 Resolved
Identify all remote emergency stop switches and prove proper operation. LEGACY COMPONENT DESC: Emergency stop switches
Condition: Improper/Lack of Maintenance
Due 17 March 2004
Resolved 17 March 2004
Lifesaving › Inflatable Liferafts
Issued 12 July 2003 Resolved
Provide 2ea. Coast Guard approved liferafts with current year Coast Guard decals.
Due 26 July 2003
Resolved 28 July 2003
Navigation › Piloting/Steering
Issued 12 July 2003 Resolved
Prove proper operation of follow-up steering (servo's/limkage adjustment).
Due 26 July 2003
Resolved 28 July 2003
Navigation › Piloting/Steering
Issued 12 July 2003 Resolved
Prove proper operation of port shaft tach.
Due 12 August 2003
Resolved 30 July 2003
Lifesaving › Embarkation Appliances/Stations
Issued 12 July 2003 Resolved
Prove proper operation of port embarkation light.
Due 26 July 2003
Resolved 28 July 2003
Fire Fighting › Fire Main
Issued 12 July 2003 Resolved
Prove proper operation of bridge firemain pressure guage.
Due 12 August 2003
Resolved 11 August 2003
Construction/Loadline › Hull
Issued 1 May 2002 Resolved
Crop and properly renew wasted hull plating, starboard side, below starboard main engine shaft. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 02.
Construction/Loadline › Structures
Issued 1 May 2002 Resolved
Crop and properly renew wasted no. 5 starboard tank forward bulkhead. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002 Resolved
Crop and properly renew wasted no. 2 port tank forward bulkhead. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002 Resolved
Crop and properly renew after pilot house window framing. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Hull
Issued 1 May 2002 Resolved
Crop and properly renew damage to port side exhaust trunk. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002 Resolved
Marine Inspector must inspect repair and witness air-test of no. 2 starboard ballast tank. LEGACY COMPONENT DESC: End Bulkhead
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Engineering › Lubricating Oil Storage/Transfer System
Issued 1 May 2002 Resolved
Remove soft patching from main engine lube oil tank, port side. Provide inspection of repair to the satisfaction of a Marine Inspector. LEGACY COMPONENT DESC: Tank
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Accommodation/Occupational Safety › Ventilation
Issued 1 May 2002 Resolved
Install proper metal vent material in clothes dryer exhaust. LEGACY COMPONENT DESC: Clothes Dryer vent
Condition: Improper Installation
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Structures
Issued 1 May 2002 Resolved
Crop and renew wasted areas in port side of pilot house IWO emergency battery boxes. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 May 2002 Resolved
Repair/renew bent main deck railing throughout vessel. LEGACY COMPONENT DESC: Deck Rail
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Construction/Loadline › Hull
Issued 1 May 2002 Resolved
Crop and renew damaged rub railing along port side of vessel. LEGACY COMPONENT DESC: Collision Strap
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Operations/Management › Drills/Instruction
Issued 1 May 2002 Resolved
Provide new liferaft embarkation instructions on both port and starboard side. LEGACY COMPONENT DESC: Abandon Ship
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Deck/Cargo › Cargo Stowage
Issued 1 May 2002 Resolved
Replace main deck cargo tie-downs as necessary. LEGACY COMPONENT DESC: Cargo tie-downs
Condition: Improper/Lack of Maintenance
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey reported dated 02 May 2002.
Accommodation/Occupational Safety › Occupational Safety
Issued 1 May 2002 Resolved
Repair damaged ladder starboard side main deck. LEGACY COMPONENT DESC: ladder
Condition: Damaged By Earlier Event
Due 15 May 2002
Resolved 15 May 2002
Resolution: Item cleared via ABS (Del Carmen, MX office) survey report dated 02 May 2002.
Lifesaving
Issued 2 March 2001 Resolved
Replace proper line on all ring buoys.
Condition: Unknown
Due 7 March 2001
Resolved 16 March 2001
Electrical
Issued 2 March 2001 Resolved
Replace wasted 225V wire runs atop pilothouse and properly fasten in metal clips provided.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Navigation
Issued 2 March 2001 Resolved
Repair GMDSS and demonstrate test and and use to USCG inspector.
Condition: Unknown
Due 7 March 2001
Resolved 16 March 2001
Electrical
Issued 2 March 2001 Resolved
Provide additional 110V AC circuits on bridge as required by 46 CFR 111.60.
Condition: Unknown
Due 2 March 2001
Resolved 2 March 2001
Lifesaving
Issued 10 December 1999 Resolved
PROVIDE PROOF OF COMPLIANCE WITH D8 RESCUE BOAT REQUIREMENT DATED 12NOV98 NO LATER THAN 24NOV00.
Condition: Unknown
Due 15 March 2000
Resolved 15 March 2000
Fire Fighting
Issued 30 November 1994 Resolved
FIXED FF HALON BOTTLES NOT HYDRO TESTED AS REQUIRED. SYSTEM NOT REQUIRED ONVESSEL.
Condition: Unknown
Due 5 December 1994
Resolved 5 December 1994
Documentation
Issued 17 January 1991 Resolved
PROVIDE CURRENT CERTIFICATE OF FINANCIAL RESPONSIBILITY WITH CURRENT OWNER/OPERATOR AND CURRENT NAME AS REQUIRED BY FEDERAL WATER POLLUTION CONTROL_x001C_ ACT SECTION 311(P)
Condition: Unknown
Due 17 January 1991
Resolved 17 January 1991
Unknown
Issued 26 January 1989 Resolved
REPAIR OILY WATER SEPERATOR IN ACCORDANCE WITH INTERNATIONAL OIL POLLUTION PREVENTION REGULATIONS ENSURING MAX. PPM ALARM AND PPM DISPLAY ARE OPERATING PROPERLY.
Condition: Unknown
Due 26 January 1989
Resolved 26 January 1989
Unknown
Issued 26 January 1987 Resolved
PRIOR TO SERVICE DUE DATE, 27FEB87, HAVE BOTH OF VESSEL'S LIFERAFTS SERVICED.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.